首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 527 毫秒
1.
The fast chemiluminescence (CL) arising from the reaction of bis(2,4,6-trichlorophenyl)oxalate (TCPO) with hydrogen peroxide in the presence of 1-(dansylamidopropyl)-1-aza-4,7,10-trithiacyclododecane (L) as a novel fluorophore, and imidazole as catalyst, has been studied in ethyl acetate solution. The relationships between the chemiluminescence intensity and concentrations of TCPO, imidazole, hydrogen peroxide and L are reported. In the presence of imidazole as catalyst, the entire CL signal was completed in less than 3 s. The quenching effect of Cu2+, Pb2+, Cd2+, Hg2+ and Ag+ ions on the chemiluminescent system was investigated, the resulting Stern–Volmer plots were obtained and the KQ values were calculated. It was found that the quenching effect of metal ions on the chemiluminescence of L decreases in the order Cu2+ > Pb2+ > Cd2+ > Hg2+ > Ag+.  相似文献   

2.
Anthroneamine derivatives 13 (H2O:DMSO; 9:1, HEPES buffer, pH 7.0 ± 0.1) undergo highly selective fluorescence quenching with Hg2+. The observed linear fluorescence intensity change allows the quantitative detection of Hg2+ between 200 nM/40 ppb—12 μM/2.4 ppm even in the presence of interfering metal ions viz. Na+, K+, Mg2+, Ca2+, Ba2+, Cr3+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Ag+, Cd2+, Pb2+. Probes 13 and their Hg2+ complexes also show the broad pH resistance for their practical applicability.  相似文献   

3.
Bishnu Prasad Joshi 《Talanta》2009,78(3):903-1129
A novel fluorescent peptide sensor containing tryptophan (donor) and dansyl fluorophore (acceptor) was synthesized for monitoring heavy and transition metal (HTM) ions on the basis of metal ion binding motif (Cys-X-X-X-Cys). The peptide probe successfully exhibited a turn on and ratiometric response for several heavy metal ions such as Hg2+, Cd2+, Pb2+, Zn2+, and Ag+ in aqueous solution. The enhancements of emission intensity were achieved in the presence of the HTM ions by fluorescent resonance energy transfer (FRET) and chelation enhanced fluorescence (CHEF) effects. The detection limits of the sensor for Cd2+, Pb2+, Zn2+, and Ag+ were lower than the EPA's drinking water maximum contaminant levels (MCL). We described the fluorescent enhancement, binding affinity, and detection limit of the peptide probe for HTM ions.  相似文献   

4.
A simple Hg2+-selective chemodosimetric system based on thiosemicarbazone was investigated. The transformation of thiosemicarbazone into semicarbazone selectively exerted by Hg2+ ions and the dimerization of semicarbazone resulted in a pronounced OFF–ON-type fluorescent signaling behavior. The coexistent metal ions, such as Fe3+, Ca2+, Cu2+, Co2+, Ni2+, Cd2+, Pb2+, Zn2+, Cr3+, Mg2+, Na+, K+, and Fe2+, had no obvious interference with the detection of Hg2+. In addition, S12–Hg2+ plays a high sensitivity for basic anions to form an ‘OFF–ON–OFF’ type signaling behavior, with the Hg2+-induced emission spectra can be quenched. Moreover, test strips based on S12 exhibited a good selectivity to Hg2+. We believe the test strips could act as a convenient and efficient Hg2+ test kit.  相似文献   

5.
Two new indole derivatives have been synthesized by a one-pot procedure and their potential as fluorescence probes for metal ions was investigated. The sensor capability of 1 and 2 toward cations such as Ag+, Cu2+, Zn2+, Cd2+, Pb2+, and Hg2− was studied in dichloromethane solution by absorption, fluorescence emission, and 1H NMR titrations. Both probes showed selectivity for Ag+ and Hg2+ ions. The results suggest that these compounds may serve as promising models for future design of novel and more potent sensors.  相似文献   

6.
A simple (R)-(−)-2-phenylglycinol functionalized Schiff base L1 and its characterization as a fluorescent–colorimetric sensor for Hg2+ ion are described. The UV–vis and fluorescence analysis in methanol and aqueous solution show complex formation between L1 and Hg2+ ion with a micromolar association constant. Competition experiments performed for the acetate salts of Hg2+, Zn2+, Co2+, Pb2+, Cd2+, Mn2+, Cu2+, Ni2+, and Ba2+ revealed that compound L1 exhibits high selectivity toward Hg2+ displaying a color change easily detectable by naked-eye and a turn-off fluorescent effect due to a chelation-enhanced quenching (CHEQ) mechanism. Moreover, addition of EDTA to L1–Hg2+ recovers the fluorescence and color offering receptor L1 as a reversible sensor for real-time applications.  相似文献   

7.
Gao J  Chen H  Dai H  Lv D  Ren J  Wang L  Yang W 《Analytica chimica acta》2006,571(1):150-155
A highly sensitive method for the determination of trace amounts of transition metal ions by use of sulfide in the Belousov-Zhabotinskii (B-Z) oscillating chemical reaction is proposed. The use of sulfide increased strongly the sensitivity of the B-Z reaction for transition metal ions, such as Ag+, Pb2+, Hg2+, Cd2+, Cu2+,and Bi3+. Results showed that the variational ratio of oscillating period (PR) is linearly proportional to the negative logarithm of concentration of metal ions. The detection limit is down to 10−12 mol L−1. Various influencing factors on the determination were also examined.  相似文献   

8.
Fluorescent chemosensor 3 can sense Cu2+ ions (1-8 μM) even in the presence of elevated levels of Ni2+, Cd2+, Zn2+, Hg2+, Ag+ and Pb2+ (5000 μM). 3 can also analyze for Ag+ ions (50-500 μM) in the presence of Ni2+, Cd2+, Zn2+, Hg2+ and Pb2+ (5000 μM) but Cu2+ strongly interferes.  相似文献   

9.
Lin YW  Liu CW  Chang HT 《Talanta》2011,84(2):324-329
We have developed a fluorescence technique for the detection of Hg2+ and Pb2+ ions using polythymine (T33)/benzothiazolium-4-quinolinium dimer derivative (TOTO-3) and polyguanine (G33)/terbium ions (Tb3+) conjugates, respectively. Hg2+ ions induce T33 to form folded structures, leading to increased fluorescence of the T33/TOTO-3 conjugates. Because Pb2+ ions compete with Tb3+ ions to form complexes with G33, the extent of formation of the G33-Tb3+ complexes decreases upon increasing the Pb2+ concentration, leading to decreased fluorescence at 545 nm when excited at 290 nm. To minimize interference from Hg2+ ions during the detection of Pb2+ ions, we conducted two-step fluorescence measurements; prior to addition of the G33/Tb3+ probe, we recorded the fluorescence of a mixture of the T33/TOTO-3 conjugates and Hg2+ ions. The fluorescence signal obtained was linear with respect to the Hg2+ concentration over the range 25.0-500 nM (R2 = 0.99); for Pb2+ ions, it was linear over the range 3.0-50 nM (R2 = 0.98). The limits of detection (at a signal-to-noise ratio of 3) for Hg2+ and Pb2+ ions were 10.0 and 1.0 nM, respectively. Relative to other techniques for the detection of Hg2+ and Pb2+ ions in soil and water samples, our present approach is simpler, faster, and more cost-effective.  相似文献   

10.
By applying an indirect strategy, a new copper (Ⅱ) complex of a thiosemicarbazone L has been successfully developed as a colorimetric chemosensor for the sensitive detection of mercury (Ⅱ) ions. In the presence of copper (Ⅱ) ions, the colorless solution of L became yellow; however, upon the addition of traces of mercury (Ⅱ) ions, the yellow color faded to colorless immediately. Other ions, including Fe3+ , Ag+ , Ca2+ , Zn2+ , Pb2+ , Cd2+ , Ni2+ , Co2+ , Cr3+ and Mg2+ had a negligible influence on the probe behavior. The detection limits were 5.0×10 -6 M and 3.0×10 -7 M of Hg2+ using the visual color changes and UV-vis changes respectively. Test strips based on Cu-L were fabricated, which could act as a convenient and efficient Hg2+ test kits.  相似文献   

11.
Herein, a simple electrochemical sensor was fabricated for sensing Hg2+ ions by using electrochemically reduced p‐nitrobenzoic acid molecules modified (ERpNBA) glassy carbon electrode (GCE). The modified electrode was applied for the determination of Hg2+ ions by using differential pulse anodic stripping voltammetry (DPASV). Experimental parameters such as concentration of p‐nitrobenzoic acid used for electrode modification, pH, accumulation time and deposition potential used for the determination of Hg2+ ions were optimized. The strong interaction between the Hg2+ ions and the lone pair of electrons on the nitrogen atoms of ERpNBA molecules leads to highly selective adsorption of Hg2+ ions on the modified electrode. Under the optimum experimental conditions, the sensor showed higher sensitivity and very low detection limit for Hg2+ ions than other metal ions such as Cd2+, Pb2+ and Zn2+ ions. The LOD for Hg2+ ions was 240 pM which is below the guideline value given by the World Health Organization and the earlier reports.  相似文献   

12.
In this work, we have used a polyaniline and cupric oxide-based nanocomposite material (PANI-CuO) for the adsorption of Pb2+, Cd2+, and Cr6+ ions from contaminated water. FTIR, FESEM, EDX and XRD methods were used in the characterisation of PANI-CuO. The maximum percentage removal of Pb2+, Cd2+, and Cr6+ ions was found to be 79.9%, 78.9% and 82.1% at 1 g of PANI-CuO for 100 mL of contaminated water. The suitability order of the isotherm model was observed as Langmuir > Freundlich > Elovich, whereas the pseudo first order model was best fitted as compared to the pseudo second order model. The rate constants were evaluated as 1.441, 1.801 and 1.661 g mg?1 min ?1, respectively. The values of ΔG0 were calculated to be ?287.4, ?849.6, and ?728.9 kJ mol?1 for Pb2+, Cd2+ and Cr6+ ions, respectively.  相似文献   

13.
14.
Stable ultra‐thin Langmuir monolayers of calix[4]resorcinarene derivatives, namely: C‐dec‐9‐enylcalix[4]resorcinarene‐O‐(R+)‐α‐methylbenzylamine (Ionophore I ), and C‐dec‐9‐enylcalix[4]resorcinarene‐O‐(S‐)‐α‐methylbenzylamine (Ionophore II ), were prepared at the air‐water interface. Their interactions with a series of heavy metals (HM) ions (Cu2+, Pb2+, Hg2+ and Cd2+) present in the aqueous subphase were investigated by measuring surface pressure‐area isotherms, at different concentrations. The surface pressure‐area (Π‐A) isotherms were stable and demonstrated the HM amounts influence on the limiting area (Alim) values, therefore confirming the examined macrocycles capability to host the metallic toxicants. Additionally, a HM concentration dependence was realized and interpreted by a selective tendency of both ionophores towards Cu2+ and Cd2+ ions over Pb2+ and Hg2+, especially at high concentrations. The HM ions interactions with the applied calix[4]resorcinarene Langmuir ultra‐thin monolayers were interpreted based on the Gibbs‐Shishkovsky adsorption equation. Moreover, quartz crystal microbalance with impedance measurement (QCM‐I), was applied for the detection of HM ions in solutions. The QCM‐I results showed the effectiveness of the coated QCM‐I crystals in detecting the ions at different concentrations. The detection limit values were in the order of 0.16, 0.3, 0.65, 1.1 ppm (Ionophore I), as well 0.11, 0.45, 0.2, 0.89 (Ionophore II) for the Cu2+, Pb2+, Hg2+ and Cd2+ cations, respectively. Additionally, a selective tendency of both ionophores towards copper ions was shown.  相似文献   

15.
In this study, we developed a fluorescence assay for the highly sensitive and selective detection of Hg2+ and Pb2+ ions using a gold nanoparticle (Au NP)-based probe. The Hg–Au and Pb–Au alloys that formed on the Au NP surfaces allowed the Au NPs to exhibit peroxidase-mimicking catalytic activity in the H2O2-mediated oxidation of Amplex UltraRed (AUR). The fluorescence of the AUR oxidation product increased upon increasing the concentration of either Hg2+ or Pb2+ ions. By controlling the pH values of 5 mM tris–acetate buffers at 7.0 and 9.0, this H2O2–AUR–Au NP probe detected Hg2+ and Pb2+ ions, respectively, both with limits of detection (signal-to-noise ratio: 3) of 4.0 nM. The fluorescence intensity of the AUR oxidation product was proportional to the concentrations of Hg2+ and Pb2+ ions over ranges 0.05–1 μM (R2 = 0.993) and 0.05–5 μM (R2 = 0.996), respectively. The H2O2–AUR–Au NP probe was highly selective for Hg2+ (>100-fold) and Pb2+ (>300-fold) ions in the presence of other tested metal ions. We validated the practicality of this simple, selective, and sensitive H2O2–AUR–Au NP probe through determination of the concentrations of Hg2+ and Pb2+ ions in a lake water sample and of Pb2+ ions in a blood sample. To the best of our knowledge, this system is the first example of Au NPs being used as enzyme-mimics for the fluorescence detection of Hg2+ and Pb2+ ions.  相似文献   

16.
Nanostructured magnesium silicate hollow spheres, one kind of non-conductive nanomaterials, were used in heavy metal ions (HMIs) detection with enhanced performance for the first time. The detailed study of the enhancing electrochemical response in stripping voltammetry for simultaneous detection of ultratrace Cd2+, Pb2+, Cu2+ and Hg2+ was described. Electrochemical properties of modified electrodes were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The operational parameters which have influence on the deposition and stripping of metal ions, such as supporting electrolytes, pH value, and deposition time were carefully studied. The anodic stripping voltammetric performance toward HMIs was evaluated using square wave anodic stripping voltammetry (SWASV) analysis. The detection limits achieved (0.186 nM, 0.247 nM, 0.169 nM and 0.375 nM for Cd2+, Pb2+, Cu2+ and Hg2+) are much lower than the guideline values in drinking water given by the World Health Organization (WHO). In addition, the interference and stability of the modified electrode were also investigated under the optimized conditions. An interesting phenomenon of mutual interference between different metal ions was observed. Most importantly, the sensitivity of Pb2+ increased in the presence of certain concentrations of other metal ions, such as Cd2+, Cu2+ and Hg2+ both individually and simultaneously. The proposed electrochemical sensing method is thus expected to open new opportunities to broaden the use of SWASV in analysis for detecting HMIs in the environment.  相似文献   

17.
In our study, the single‐use & eco‐friendly electrochemical sensor platform based on herbal silver nanoparticles (AgNPs) was developed for detection of mercury (II) ion (Hg2+). For this purpose, the surface of pencil graphite electrode (PGE) was modified with AgNPs and folic acid (FA), respectively. The concentrations of AgNPs and FA were firstly optimized by differential pulse voltammetry (DPV) to obtain an effective surface modification of PGE. Each step at the surface modification process was characterized by using cyclic voltammetry (CV) and electrochemical impedence spectroscopy (EIS). The limit of detection (LOD) for Hg2+ was estimated and found to be 8.43 μM by CV technique. The sensor presented an excellent selectivity for Hg2+ against to other heavy metal ions such as Ca2+, Cd2+, Cr3+, Cu2+, Mg2+, Ni2+, Pb2+, Zn2+, Co2+ and Mn2+. Moreover, a rapid, selective and sensitive detection of Hg2+ was successfully performed in the samples of tap water within 1 min.  相似文献   

18.
The aim of this study was to investigate the performance of monoliths composed of hydroxyethyl methacrylate (HEMA) to which N-methacryloyl-(L)-cysteine methyl ester (MAC) was polymerized for removal of heavy metal ions. Poly(HEMA-MAC) monolith was produced by bulk polymerization. Poly(HEMA-MAC) monolith was characterized by FTIR and scanning electron microscopy (SEM). The poly(HEMA-MAC) monolith with a swelling ratio of 89%, and containing 69.4 μmol MAC/g were used in the adsorption studies. Adsorption capacity of the monolith for the metal ions, i.e., Cu2+, Cd2+, Zn2+, Hg2+, and Pb2+ were investigated in aqueous media containing different amounts of the ions (10–750 mg/L) and at different pH values (3.0–7.0). The maximum adsorption capacities of the poly(HEMA-MAC) monolith were 68.2 mg/g for Zn2+, 129.2 mg/g for Cu2+, 245.8 mg/g for Pb2+, 270.2 mg/g for Hg2+, and 284.0 mg/g for Cd2+. pH significantly affected the adsorption capacity of MAC incorporated monolith. The competitive adsorption capacities were 587 μmol/g for Zn2+, 1646 μmol/g for Cu2+, 687 μmol/g for Pb2+, 929 μmol/g for Hg2+, and 1993 μmol/g for Cd2+. The chelating monolith exhibited the following metal ion affinity sequence on molar basis: Cd2+ > Cu2+ > Hg2+ > Pb2+ > Zn2+. The formation constants of MAC–metal ion complexes have been investigated applying the method of Ruzic. The calculated values of stability constants were 5.28 × 104 L/mol for Cd2+, 4.16 × 104 L/mol for Cu2+, 2.27 × 104 L/mol for Hg2+, 1.98 × 104 L/mol for Pb2+, and 1.25 × 104 L/mol for Zn2+. Stability constants were increased with increasing binding affinity. The chelating monoliths can be easily regenerated by 0.1 M HNO3 with higher effectiveness. These features make poly(HEMA-MAC) monolith a potential adsorbent for heavy metal removal.  相似文献   

19.
The binding affinity for Pb2+, Cd2+ and Hg2+ of the sinapic acid–calix[4]arene hybrid 2, having four sinapyl pendants at the upper rim, has been investigated via an UV–Vis study. Compound 2 has better complexing ability than the monomeric p-phenetidine derivative 1. This highlights that the clustering of sinapyl units in a basket-like structure, dictated by the calixarene scaffold, greatly enhances the complexing properties. Ligand 2 forms complexes even with Hg2+, which is not complexed by 1 at all; the complexes formed by 2 with Pb2+ and Cd2+ are much stronger than the analogous complexes formed by 1. The UV–Vis investigation shows that the hybrid 2 markedly favors Pb2+ over Cd2+ and Hg2+. Information on the structural properties of the complex species was obtained by 1H NMR spectroscopy. NMR data show that all three metal ions are placed into the cavity consisting of the calixarene scaffold and the sinapyl pendants, though their binding affects the coordinating regions to a different extent.  相似文献   

20.
A new pyrene derivative (1) containing a diaminomaleonitrile moiety exhibits high selectivity for Cu2+ detection. Significant fluorescence enhancement was observed with chemosensor 1 in the presence of Cu2+. However, the metal ions Ag+, Ca2+, Cd2+, Co2+, Fe2+, Fe3+, Hg2+, Mg2+, Mn2+, Ni2+, Pb2+, and Zn2+ produced only minor changes in fluorescence values for the system. The apparent association constant (Ka) of Cu2+ binding in chemosensor 1 was found to be 5.55×103 M−1. The maximum fluorescence enhancement caused by Cu2+ binding in chemosensor 1 was observed over the pH range 5-7.5.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号