首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
Transient states maintained by energy dissipation are an essential feature of dynamic systems where structures and functions are regulated by fluxes of energy and matter through chemical reaction networks. Perfected in biology, chemically fueled dissipative networks incorporating nanoscale components allow the unique properties of nanomaterials to be bestowed with spatiotemporal adaptability and chemical responsiveness. We report the transient dispersion of gold nanoparticles in water, powered by dissipation of a chemical fuel. A dispersed state that is generated under non-equilibrium conditions permits fully reversible solid–liquid or liquid–liquid phase transfer. The molecular basis of the out-of-equilibrium process is reversible covalent modification of nanoparticle-bound ligands by a simple inorganic activator. Activator consumption by a coupled dissipative reaction network leads to autonomous cycling between phases. The out-of-equilibrium lifetime is tunable by adjusting the pH value, and reversible phase cycling is reproducible over several cycles.  相似文献   

2.

Rapid, inexpensive, and efficient sample-preparation by dispersive liquid–liquid microextraction (DLLME) then gas chromatography with flame ionization detection (GC–FID) have been used for extraction and analysis of BTEX compounds (benzene, toluene, ethylbenzene, and xylenes) in water samples. In this extraction method, a mixture of 25.0 μL carbon disulfide (extraction solvent) and 1.00 mL acetonitrile (disperser solvent) is rapidly injected, by means of a syringe, into a 5.00-mL water sample in a conical test tube. A cloudy solution is formed by dispersion of fine droplets of carbon disulfide in the sample solution. During subsequent centrifugation (5,000 rpm for 2.0 min) the fine droplets of carbon disulfide settle at the bottom of the tube. The effect of several conditions (type and volume of disperser solvent, type of extraction solvent, extraction time, etc.) on the performance of the sample-preparation step was carefully evaluated. Under the optimum conditions the enrichment factors and extraction recoveries were high, and ranged from 122–311 to 24.5–66.7%, respectively. A good linear range (0.2–100 μg L−1, i.e., three orders of magnitude; r 2 = 0.9991–0.9999) and good limits of detection (0.1–0.2 μg L−1) were obtained for most of the analytes. Relative standard deviations (RSD, %) for analysis of 5.0 μg L−1 BTEX compounds in water were in the range 0.9–6.4% (n = 5). Relative recovery from well and wastewater at spiked levels of 5.0 μg L−1 was 89–101% and 76–98%, respectively. Finally, the method was successfully used for preconcentration and analysis of BTEX compounds in different real water samples.

  相似文献   

3.
Here is reported a novel analytical approach for the extractive separation and determination of enantiomeric ratios of aristocularine in bovine serum albumin. The results demonstrate suitable analytical performances. The separation was performed by chiral high-performance liquid chromatography with a 5-µm column using a mobile phase of 1:1 n-hexane:ethanol at a flow rate of 0.7?mL?min?1 with ultraviolet–visible absorption, circular dichroism, and polarimetric detection. The enantiomers were eluted at 13.2 and 15.6?min for (+) and (?)-aristocularine, with a resolution of 1.58 and a separation factor of 1.27. The analytical parameters for the dispersive liquid–liquid microextraction were optimized; under these conditions, the extraction recoveries were from 88.6% to 93.9% for a two-step extraction. The precision, reported as the percent relative standard deviation, had values from 2.9% to 3.2% for 0.5?µg?mL?1 of analyte for five replicate measurements using ultraviolet–visible absorption and circular dichroism detection. The limits of detection were between 0.05 and 0.08?µg?mL?1 with enrichment ratios up to a value of 12.  相似文献   

4.
A novel method, dispersive liquid–liquid microextraction coupled with liquid chromatography-variable wavelength detector (LC-VWD), has been developed for the determination of chloramphenicol (CAP) in honey. A mixture of extraction solvent (30 μL 1,1,2,2-tetrachloroethane) and dispersive solvent (1.00 mL acetonitrile) were rapidly injected by syringe into a 5.0 mL real sample for the formation of cloudy solution, the analyte in the sample was extracted into the fine droplets of C2H2Cl4. After extraction, phase separation was performed by centrifugation and the enriched analyte in the sedimented phase was determined by LC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2,000 μg kg?1 for target analyte. The enrichment factor for CAP was 68.2, and the limit of detection (S/N = 3) were 0.6 μg kg?1. The relative standard deviation (RSD) for the extraction of 10 μg kg?1 of CAP was 4.3% (= 6). The main advantages of method are high speed, high enrichment factor, high recovery, good repeatability and extraction solvent volume at μL level. Honey samples were successfully analyzed using the proposed method.  相似文献   

5.
6.
The adsorption characteristics of Span 80 at liquid/liquid interfaces were investigated. The equilibrium interfacial tension values were successfully fitted with a Langmuir isotherm resulting in the determination of a mean molecular area from 25 to 35 Å2/mol. The measured interfacial tension values and deduced adsorption parameters depend on the experimental technique used to obtain them, either Du Noüy ring or profile analysis tensiometry. Two possible explanations to such phenomenon are provided. Adsorption kinetics of Span 80 at liquid/liquid interfaces were studied, and it was concluded that the diffusion of Span 80 molecules from the bulk is the rate determining step of the adsorption. Finally the interfacial rheology properties were investigated and compared to the Lucassen–van den Tempel model. A good match was obtained when the isotherm parameters determined by profile analysis tensiometry were used.   相似文献   

7.
《Analytical letters》2012,45(17):2754-2772
A simple, rapid, efficient, and environmentally friendly method was developed for the preconcentration of atrazine, simazine, diuron, bentazone, tebuconazole, and fipronil from water. Dispersive liquid–liquid microextraction was employed with determination by liquid chromatography–tandem mass spectrometry. The volumes of extraction and disperser solvents, the concentration of sodium chloride, and the pH were optimized by response surface methodology. The optimum conditions involved the use of 150 µL of 1:1 (v/v) monochlorobenzene:dichlorobenzene as the extraction solvent, 2 mL acetonitrile as the disperser solvent, and 10 mL of sample at pH 3.0. The accuracy was evaluated in terms of recovery values that were from 54 to 112%. The relative standard deviations ranged from 4 to 27%. The limits of quantification were between 0.005 and 0.05 µg L?1. The optimized method had low matrix effects for the analytes and the results demonstrated application for the determination of pesticides in water.  相似文献   

8.
A simple method for determination of rare earth elements (REEs) by liquid–liquid–liquid microextraction (LLLME) coupled with capillary electrophoresis and ultraviolet technique was developed. In the LLLME system, 40 mmol L?1 4-benzoyl-3-methy-1-phenyl-5-pyrazolinone (PMBP) acted as extractant and 4% (v/v) formic acid was used as back-extraction solution. The parameters influencing the LLLME, including the type of the organic solvent, sample pH, formic acid concentration, PMBP concentration, extraction time, volume of organic solvent, stirring rate and phase volume ratio, were investigated. Under the optimized conditions, the detection limits (S/N = 3) of REEs were in the range of 0.19–0.70 ng mL?1. The developed method was successfully applied to the determination of trace amounts of REEs in water samples.  相似文献   

9.
Russian Journal of Applied Chemistry - Lithium–lead alloys are of main interest in the liquid state. They were subjects of numerous studies, in particular, of those dealing with structural...  相似文献   

10.
Summary A sensitive and selective liquid chromatographic method coupled with electrospray ionization tandem mass spectrometry (LC–ESI–MS–MS) has been developed for quantification of felodipine in human and dog plasma. Compounds were separated on a 2.0 mm × 150 mm, 5.0 m particle, C8 column with 1 m m ammonium acetate–acetonitrile, 20:80, pH 6.0, as mobile phase at a flow rate of 200 L min–1. Nifedipine was used as internal standard. Plasma samples were extracted with diethyl ether, the centrifuged upper layer was evaporated, the residue was reconstituted with mobile phase, and the reconstituted samples were injected. The analytical column lasted for at least 1000 injections. By use of multiple reaction monitoring (MRM) mode in MS–MS felodipine and nifedipine were detected without severe interference from the human or dog plasma matrix. Felodipine produced a protonated precursor ion ([M + H]+) at m/z 384 and a corresponding product ion at m/z 338. And internal standard (nifedipine) produced a protonated precursor ion ([M + H]+) at m/z 347 and a corresponding product ion at m/z 315. Detection of felodipine in human and dog plasma was accurate and precise, with a limit of quantification of 0.05 ng mL–1. The method has been successfully applied to preliminary pharmacokinetic study of felodipine in human and dog plasma.  相似文献   

11.
The object of this study was to measure the liquid–liquid equilibria (LLE) data of binary mixtures containing ionic liquids and citrus essential oil. We investigated linalool as the citrus essential oil, and 1-alkyl-3-methyl-imidazolium bis(trifluoromethanesulfonyl)imide ([C n MIM]+[TFSI]?) as the ionic liquid. Firstly, the experimental apparatus and procedure for the LLE measurement of mixtures containing ionic liquids were verified by measuring the LLE of the binary mixture 1-hexyl-3-methyl-imidazolium bis(trifluoromethanesulfonyl)imide ([C6MIM]+[TFSI]?) + 1-hexanol as a reference test system recommended by Marsh et al. (Pure Appl Chem 81:781–789, 2009). Next, the LLE data for IL + linalool were obtained, and the LLE data of two binary mixtures 1-butyl-3-methyl-imidazolium bis(trifluoromethanesulfonyl)imide ([C4MIM]+[TFSI]?) or [C6MIM]+[TFSI]? + linalool were determined. The experimental LLE data were satisfactorily represented by the non-random two-liquid model.  相似文献   

12.
Dispersive liquid–liquid microextraction using deep eutectic solvents, as novel extraction solvents, was developed for the separation, preconcentration, and determination of chlorophenol, 2,3-dihydroxybenzoic acid, p-cresol, 4-chlorophenol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol in vegetable oil. Seven deep eutectic solvents composed of choline chloride and different hydrogen bond donors (ethyl glycol, glycerol, 1,2-butanediol, 1,4-butanediol, 1,6-hexanediol, urea, and acetic acid) were characterized. The deep eutectic solvents formed by choline chloride-1,6-hexanediol in a 1:2 molar ratio provided the highest extraction efficiency. The sonication time, deep eutectic solvent volume, and disperser solvent were optimized. Under the optimal conditions of a sonication time of 11?min, a deep eutectic solvent volume of 90?µL, and acetone as the disperser solvent, extraction recoveries from 76.1 to 88.3% were obtained with 8.46 to 9.46 enrichment factors and the limits of detection exceeding 0.1?µg/mL with the relative standard deviations from 1.0 to 3.5%. This method using dispersive liquid–liquid microextraction with deep eutectic solvents is simple and provides high enrichment.  相似文献   

13.

An environmentally benign method of sample preparation based on dispersive liquid–liquid microextraction and solidification of floating organic droplets (DLLME-SFO) coupled with high-performance liquid chromatography with ultraviolet detection has been developed for analysis of non-steroidal anti-inflammatory drugs (NSAIDs) in biological fluids. A low-toxicity solvent was used to replace the chlorinated solvents commonly used in conventional DLLME. Seven conditions were investigated and optimized: type and volume of extraction solvent and dispersive solvent, extraction time, effect of addition of salt, and sample pH. Under the optimum conditions, good linearity was obtained in the range 0.01–10 µg mL−1, with coefficients of determination (r 2) >0.9949. Detection limits were in the range 0.0034–0.0052 µg mL−1 with good reproducibility (RSD) and satisfactory inter-day and intra-day recovery (95.7–115.6 %). The method was successfully used for analysis of diclofenac, mefenamic acid, and ketoprofen in human urine. Analysis of urine samples from a patient 2 and 4 h after administration of diclofenac revealed concentrations of 1.20 and 0.34 µg mL−1, respectively.

  相似文献   

14.
An efficient method for fast elucidation of the electrochemical reactions of polycyclic aromatic hydrocarbons (PAH) has been set up by applying post-column electrochemistry in liquid chromatography–mass spectrometry (LC–MS). With this set-up strong improvement of sensitivity in the LC–MS analysis of PAH is observed. Due to their low redox potentials, the non-polar PAH are converted into the respective radical cations, which may further react with constituents of the mobile phase and in additional electrochemical oxidation steps. Among other products, mono-, di-, and trioxygenated species are observed in aqueous solutions, alkoxylated compounds in alcohols, and solvent adducts in the presence of acetonitrile. While more different products are observed by using atmospheric pressure chemical ionization in the positive-ion mode (APCI(+)), the deprotonation of hydroxylated species results in very clear spectra in the negative-ion mode (APCI(–)). Deuterated PAH and deuterated solvents were used to gain additional information on the formation of the reaction products.  相似文献   

15.

Single-drop microextraction (SDME) and hollow-fiber membrane microextraction (HFME) belong to methods of the liquid-phase microextraction preconcentration of organic compounds. These methods are characterized by the low consumption of organic solvents, high preconcentration factors, simplicity, low cost, ease of combination with various chromatographic methods; processes of preconcentration and sample injection are combined in a single device. Since the emergence of SDME (1996) and HFME (1999), a large number of versions have been developed that differ in the preconcentration technique, nature of the extractants used, and combinations with methods for the subsequent determination of the preconcentrated substances. The popularity of these methods among the analysts is evidenced by many reviews that we have summarized in this publication.

  相似文献   

16.

In this study, the extraction of lipophilic wood extractives from dissolving pulp samples using ionic liquid–liquid extraction and a two phase hollow fibre supported liquid membrane was investigated. Ionic liquids are capable of dissolving a range of organic and polymeric compounds and are biodegradable, with a negligible vapour pressure. Pulp samples were dissolved in a suitable amount of molten 1-butyl-3-methylimidazolium chloride to give 5 % cellulose solution. Pure cellulose was regenerated by adding water and filtered off. The ionic liquid-aqueous filtrate was first extracted for lipophilic extractives using liquid–liquid extraction. Then, a two phase hollow fibre supported liquid membrane extraction of lipophilic extractives was performed to extract the derivatized compounds prior to analysis by gas chromatography mass spectrometry. The operational parameters of this sample preparation approach were optimised using sterols and fatty acid methyl esters. The variation of enrichment factors and extraction efficiency with respect to liquid membrane, extraction time, stirring speed and sample pH were observed and used to get the optimal parameters. The approach was used in the analysis of oxygen bleached dissolving pulp samples in which main compounds identified were fatty acids, sterols, fatty alcohols, steroid hydrocarbons and ketones. These compounds were similar to those obtained using molecular solvent extraction method, which indicated the absence of chemical reaction between extractives and ionic liquid used.

  相似文献   

17.
Capillary electrophoresis coupled with electrochemiluminescence detection was developed for the separation and determination of dioxopromethazine hydrochloride (DPZ) enantiomers. Performance parameters of the proposed method were evaluated. An improved separation of DPZ enantiomers could be achieved after adding boric acid to buffer. The enantiomers were completely separated with running buffer of 16.5 mM β-CD in 25 mM tris-H3PO4–40 mM H3BO3 at pH 2.5. The proposed method was successfully applied to the separation and determination of DPZ enantiomers in human urine with a liquid–liquid extraction procedure.  相似文献   

18.
Dispersive liquid–liquid microextraction (DLLME) for extraction and preconcentration of phenoxyacetic acid herbicides in water samples is described. After adjusting the pH to 1.5, the sample was extracted in the presence of 10% w/v sodium chloride by injecting 1 mL acetone as disperser solvent containing 25 μL of chlorobenzene as extraction solvent. The effect of parameters, such as the nature and amount of extraction and disperser solvents, ionic strength of the sample, pH, temperature and extraction time were optimized. DLLME was followed by LC for the determination of 2,4-dichlorophenoxyacetic acid and 4-chloro-2-methyl phenoxyacetic acid. The method had good linearity and a wide linear dynamic range (0.5–750 μg L?1) with a detection limit of 0.16 μg L?1 for both the PAAs, making it suitable for their determination in water samples.  相似文献   

19.
This study describes an accurate, sensitive, and specific chromatographic method for the simultaneous quantitative determination of lamivudine and zidovudine in human blood plasma, using stavudine as an internal standard. The chromatographic separation was performed using a C8 column (150 × 4.6 mm, 5 μm), and ultraviolet absorbency detection at 270 nm with gradient elution. Two mobile phases were used. Phase A contained 10 mM potassium phosphate and 3% acetonitrile, whereas Phase B contained methanol. A linear gradient was used with a variability of A-B phase proportion from 98–2% to 72–28%, respectively. The drug extraction was performed with two 4 mL aliquots of ethyl acetate.  相似文献   

20.
Ultrasound-assisted dispersive liquid–liquid microextraction was coupled with gas chromatography—mass spectrometry for the determination of phthalate esters in milk. Dimethyl phthalate, diethyl phthalate, dibutyl phthalate, benzyl butyl phthalate, bis(2-ethylhexyl) phthalate, and dioctyl phthalate were analyzed in five brands of pasteurized Turkish milk. The efficiencies of the extraction procedure for the analytes were between 66 and 100%. The linear dynamic ranges of the calibration curves were from 0.025 to 1.000 µg/mL with correlation coefficients exceeding 0.99. The precision of the method is acceptable with relative standard deviation values below 5%. Dibutyl phthalate and bis(2-ethylhexyl) phthalate were commonly observed in milk.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号