首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method is described for the identification and relative quantification of proteomes using accurate mass tags (AMT) generated by nLC-dual ESI-FT-ICR-MS on a 7T instrument in conjunction with stable isotope labeling using 16O/18O ratios. AMTs were used for putative peptide identification, followed by confirmation of peptide identity by tandem mass spectrometry. For a combined set of 58 tryptic peptides from bovine serum albumin (BSA) and human transferrin, a mean mass measurement accuracy of 1.9 ppm +/-0.94 ppm (CIM99%) was obtained. This subset of tryptic peptides was used to measure 16O/18O ratios of 0.36 +/- 0.09 (CIM99%) for BSA (micro = 0.33) and 1.48 +/- 0.47 (CIM99%) for transferrin (micro = 1.0) using a method for calculating 16O/18O ratios from overlapping isotopic multiplets arising from mixtures of 16O, 18O1, and 18O2 labeled C-termini. The model amino acid averagine was used to calculate a representative molecular formula for estimating and subtracting the contributions of naturally occurring isotopes solely as a function of peptide molecular weight. The method was tested against simulated composite 16O/18O spectra where peptide molecular weight, 16O/18O ratio, 18O1/18O2 ratios, and number of sulfur atoms were varied. Relative errors of 20% or less were incurred when the 16O/18O ratios were less than three, even for peptides where the number of sulfur atoms was over- or under-estimated. These data demonstrate that for biomarker discovery, it is advantageous to label the proteome representing the disease state with 18O; and the method is not sensitive to variations in 18O1/18O2 ratio. This approach allows a comprehensive differentiation of expression levels and tentative identification via AMTs, followed by targeted analysis of over- and under-expressed peptides using tandem mass spectrometry, for applications such as the discovery of disease biomarkers.  相似文献   

2.
High mass measurement accuracy of peptides in enzymatic digests is critical for confident protein identification and characterization in proteomics research. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) can provide low or sub-ppm mass accuracy and ultrahigh resolving power. While for ESI-FT-ICR-MS, the mass accuracy is generally 1 ppm or better, with matrix-assisted laser desorption/ionization (MALDI)-FT-ICR-MS, the mass errors can vary from sub-ppm with internal calibration to over 100 ppm with conventional external calibration. A novel calibration method for (15)N-metabolically labeled peptides from a batch digest of a proteome is described which corrects for space charge induced frequency shifts in FT-ICR spectra without using an internal calibrant. This strategy utilizes the information from the mass difference between the (14)N/(15)N peptide peak pairs to correct for space charge induced mass shifts after data collection. A procedure for performing the mass correction has been written into a computer program and has been successfully applied to high-performance liquid chromatography-MALDI-FT- ICR-MS measurement of (15)N-metabolic labeled proteomes. We have achieved an average measured mass error of 1.0 ppm and a standard deviation of 3.5 ppm for 900 peptides from 68 MALDI-FT-ICR mass spectra of the proteolytic digest of a proteome from Methanococcus maripaludis.  相似文献   

3.
米薇  王晶  应万涛  贾伟  蔡耘  钱小红 《色谱》2010,28(2):108-114
多维色谱分离、串联质谱分析技术已在蛋白质组研究中得到广泛应用。然而生物样品的蛋白质以及全酶切肽段具有高度的复杂性,这严重干扰了蛋白质高通量、规模化的分析。通过标签肽段富集进行样品预分离可以降低体系的复杂程度。本文建立了一种基于共价色谱技术选择性分离富集含半胱氨酸肽的方法,从而降低了样品体系的复杂程度。首先以牛血清白蛋白(BSA)的酶切肽段为模型,对富集条件进行了优化和考察,并在此基础上通过5种蛋白质酶切肽段混合物的富集对该方法进行了验证。结果证明此方法的重现性好,富集效率高,富集特异性好,能有效地富集鉴定含半胱氨酸肽段。所建立的方法在复杂体系的蛋白质组研究中具有广泛的应用前景,为复杂样品的蛋白质高通量、自动化、规模化鉴定和定量研究提供了实用技术。  相似文献   

4.
Zhou H  Dai J  Sheng QH  Li RX  Shieh CH  Guttman A  Zeng R 《Electrophoresis》2007,28(23):4311-4319
The conventional 2-D LC-MS/MS setup for global proteome analysis was based on online and offline salt gradients (step and continuous) using strong-cation-exchange chromatography in conjunction with RP chromatography and MS. The use of the online system with step salt elution had the possibility of resulting in peptide overlapping across fractions. The offline mode had the option to operate with continuous salt gradient to decrease peak overlap, but exhibited decreased robustness, lower reproducibility, and sample loss during the process. Due to the extensive washing requirement between the chromatography steps, online continuous gradient was not an option for salt elution. In this report, a fully automated, online, and continuous gradient (pH continuous online gradient, pCOG) 2-D LC-MS/MS system is introduced that provided excellent separation and identification power. The pH gradient-based elution provided more basic peptides than that of salt-based elution. Fraction overlap was significantly minimized by combining pH and continuous gradient elutions. This latter approach also increased sequence coverage and the concomitant confidence level in protein identification. The salt and pH elution-based 2-D LC-MS/MS approaches were compared by analyzing the mouse liver proteome.  相似文献   

5.
We describe the application of capillary liquid chromatography (LC) time-of-flight (TOF) mass spectrometric instrumentation for the rapid characterization of microbial proteomes. Previously (Lipton et al., Proc. Natl. Acad. Sci. U.S.A. 2002, 99, 11049) the peptides from a series of growth conditions of Deinococcus radiodurans have been characterized using capillary LC MS/MS and accurate mass measurements which are captured as an accurate mass and time (AMT) tag database. Using this AMT tag database, detected peptides can be assigned using measurements obtained on a TOF due to the additional use of elution time data as a constraint. When peptide matches are obtained using AMT tags (i.e., using both constraints) unique matches of a mass spectral peak occurs 88% of the time. Not only are AMT tag matches unique in most cases, the coverage of the proteome is high; approximately 3500 unique peptide AMT tags are found on average per capillary LC run. From the results of the AMT tag database search, approximately 900 ORFs detected using LC-TOFMS, with approximately 500 ORFs covered by at least two AMT tags. These results indicate that AMT database searches with modest mass and elution time criteria can provide proteomic information for approximately one thousand proteins in a single run of <3 h. The advantage of this method over using MS/MS based techniques is the large number of identifications that occur in a single experiment as well as the basis for improved quantitation. For MS/MS experiments, the number of peptide identifications is severely restricted because of the time required to dissociate the peptides individually. These results demonstrate the utility of the AMT tag approach using capillary LC-TOF MS instruments, and also show that AMT tags developed using other instrumentation can be effectively utilized.  相似文献   

6.
Accurate mass values as obtainable by Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) were employed in a theoretical study to differentiate between nonmodified and phosphorylated peptides. It was found that for peptide masses up to 1,000 u more than 98% of all theoretical monophosphorylated peptides (all possible combinations of proteinogenic amino acids having one phosphorylation on S, T, or Y) can be distinguished from nonphosphorylated peptides directly by their mass, if mass values are determined with an accuracy of better than +/-0.1 ppm. At a peptide mass of 1,500 u still 70% of all possible monophosphorylated peptides are distinguishable from nonmodified peptides by their accurate mass alone. In contrast to established techniques of data-dependent multidimensional mass spectrometry, only the mass of the precursor ion is necessary to decide upon subsequent fragment ion analysis of a peptide for sequence analysis in an LC-MS/MS investigation of a complex sample, when using a precalculated mass distribution table of theoretical peptides. A mass distribution table of nonphosphorylated and monophosphorylated peptides with a bin width of 0.1 mu was made available via the open web site www.peptidecomposer.com.  相似文献   

7.
Protein identifications by peptide mass fingerprint analyses with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) were performed using microelectrospray ionization coupled to nano liquid chromatography (NanoLC), as well as using matrix-assisted laser desorption/ionization (MALDI). Tryptic digests of bovine serum albumin (BSA), diluted down to femtomole quantities, have been desalted by fast NanoLC under isocratic elution conditions as the high resolving power of FT-ICR MS enables peptides to be separated during the mass analysis stage of the experiment. The high mass accuracy achieved with FT-ICR MS (a few ppm with external calibration) facilitated unambiguous protein identification from protein database searches, even when only a few tryptic peptides of a protein were detected. Statistical confidence in the database search results was further improved by internal calibration due to increased mass accuracy. Matrix-assisted laser desorption/ionization and micro electrospray ionization (ESI) FT-ICR showed good mass accuracies in the low femtomole range, yet a better sensitivity was observed with MALDI. However, in higher femtomole ranges slightly lower mass accuracies were observed with MALDI FT-ICR than with microESI FT-ICR due to scan-to-scan variations of the ion population in the ICR cell. Database search results and protein sequence coverage results from NanoLC FT-ICR MS and MALDI FT-ICR MS, as well as the effect of mass accuracy on protein identification for the peptide mass fingerprint analysis are evaluated.  相似文献   

8.
It was the aim of this study to compare the performance of displacement chromatography with gradient elution chromatography both applied as the cation-exchange separation step for a proteome analysis in a bottom-up approach using multidimensional chromatography for the separation of tryptic peptides prior to their mass spectrometric analysis. The tryptic digest of the human Cohn fraction IV-4 served as a sample. For both chromatography modes commonly used operating parameters were chosen thus ensuring optimal separation results of equal sample amounts for each mode. All resulting fractions were analyzed with an HPLC-chip–LC–MS system. The eluate of the HPLC-chip column was ionized by electrospray ionization (ESI) and analyzed with an ion-trap mass spectrometer. For guaranteeing high confidence concerning the identity of the peptides, the mass spectrometric data were processed by different bioinformatic tools applying stringent criteria. By the displacement approach the total amount of identified proteins (78) was significantly higher than in the gradient mode (58). The results showed that displacement chromatography is a well suited alternative in comparison to gradient elution separation for analysis of proteomes via the bottom-up approach applying multidimensional chromatography, especially in those cases when larger quantities of proteins are available.  相似文献   

9.
燕蒙  赵洋  张养军  应万涛  钱小红 《色谱》2019,37(5):477-483
复杂生物系统蛋白质组的深度覆盖鉴定得益于近年来快速发展的高效色谱分离和串联质谱分析技术。二维高效液相色谱(2-D HPLC)是实现复杂肽混合物正交分离的有效手段,但其缺点是运行时间长,通常要求肽上样量在毫克级别,且收集时的组分体积大,后续合并流程复杂,而有望替代其的StageTip技术,则由于有限的色谱分离梯度,难以达到充分的正交分离。该文探索了超高效液相色谱(UPLC)和八端口转子阀联用,作为高效、便捷肽段预分离和收集系统的可行性。研究结果显示,将UPLC的高pH反相色谱分馏与在线LC-MS/MS相结合,可以实现高pH和低pH条件下基于肽段不同色谱保留行为的正交互补分离,在蛋白质鉴定方面表现出优越的性能。应用该方法对人肝癌细胞系HepG2进行3次技术重复试验,重复试验间具有非常高的定量重现性(决定系数R2>0.95)。与传统StageTip方法相比,肽段鉴定数提高了23.52%。该分级方法灵活、稳定,能够针对较少的样品开展蛋白质组深度覆盖分析。  相似文献   

10.
Mass accuracy is a key parameter in proteomic experiments, improving specificity, and success rates of peptide identification. Advances in instrumentation now make it possible to routinely obtain high resolution data in proteomic experiments. To compensate for drifts in instrument calibration, a compound of known mass is often employed. This ‘lock mass’ provides an internal mass standard in every spectrum. Here we take advantage of the complexity of typical peptide mixtures in proteomics to eliminate the requirement for a physical lock mass. We find that mass scale drift is primarily a function of the m/z and the elution time dimensions. Using a subset of high confidence peptide identifications from a first pass database search, which effectively substitute for the lock mass, we set up a global mathematical minimization problem. We perform a simultaneous fit in two dimensions using a function whose parameterization is automatically adjusted to the complexity of the analyzed peptide mixture. Mass deviation of the high confidence peptides from their calculated values is then minimized globally as a function of both m/z value and elution time. The resulting recalibration function performs equal or better than adding a lock mass from laboratory air to LTQ-Orbitrap spectra. This ‘software lock mass’ drastically improves mass accuracy compared with mass measurement without lock mass (up to 10-fold), with none of the experimental cost of a physical lock mass, and it integrated into the freely available MaxQuant analysis pipeline ().  相似文献   

11.
Advances in proteomics are continuing to expand the ability to analyze the serum proteome. In recent years, it has been realized that in addition to the circulating proteins, human serum also contains a large number of peptides. Many of these peptides are believed to be fragments of larger proteins that have been at least partially degraded by various enzymes such as metalloproteases. Identifying these peptides from a small amount of serum/plasma is difficult due to the complexity of the sample, the low levels of these peptides, and the difficulties in getting a protein identification from a single peptide. In this study, we modified previously published protocols for using centrifugal ultrafiltration, and unlike past studies did not digest the filtrate with trypsin with the intent of identifying endogenous peptides with this method. The filtrate fraction was concentrated and analyzed by a reversed phase-high performance liquid chromatography system connected to a nanospray ionization hybrid ion trap-Fourier transform mass spectrometer (LTQ-FTMS). The mass accuracy of this instrument allows confidence for identifying the protein precursors by a single peptide. The utility of this approach was demonstrated by the identification of over 300 unique peptides with 2 ppm or better mass accuracy per serum sample. With confident identifications, the origin and function of native serum peptides can be more seriously explored. Interestingly, over 34 peptide ladders were observed from over 17 serum proteins. This indicates that a cascade of proteolytic processes affects the serum peptidome. To examine whether this result was an artifact of serum, matched plasma and serum samples were analyzed with similar peptide ladders found in each.  相似文献   

12.
Precision proteomics requires high-resolution and high mass accuracy peptide measurements. The Orbitrap instrument achieves excellent resolution on a chromatographic time scale and its design is favorable for very high mass accuracy. Here we describe how mass precision for each peptide increases successively by considering all associated measurements, starting from the MS peak and proceeding to its chromatographic elution profile, isotope envelope, and stable isotope pair in SILAC measurements. We extract peptide charge pairs to perform nonlinear recalibration of the Orbitrap mass scale through spline interpolation. The deviation of mass values determined from charge pairs is used to convert mass precision to mass accuracy for subsequent database search. The corrected mass precision is consistent with the mass accuracy independently determined by database identification. Individual mass deviations range from below 100 ppb for peptides with many associated mass measurements and good signal intensities to low ppm for peptides with few mass measurements and signals close to the noise level. This extremely high and individualized mass accuracy is equivalent to a substantial increase in database identification score.  相似文献   

13.
A primary challenge in proteome measurements is to be able to detect, identify, and quantify the extremely complex mixtures of proteins. The relative abundances of interest span at least six orders of magnitude for mammalian proteomes, and this constitutes an intractable challenge for high throughput proteome studies. We have recently described a new approach, Dynamic Range Enhancement Applied to Mass Spectrometry (DREAMS), which is based upon the selective ejection of the most abundant species to expand the dynamic range of Fourier transform ion cyclotron resonanace (FTICR) measurements. The basis of our approach is on-the-fly data-dependent selective ejection of highly abundant species, followed by prolonged accumulation of remaining low-abundance species in a quadrupole external to the FTICR ion trap. Here we report the initial implementation of this approach with high efficiency capillary reverse phase LC separations and high magnetic field electrospray ionization FTICR mass spectrometry for obtaining enhanced coverage in quantitative measurements for mammalian proteomes. We describe the analysis of a sample derived from a tryptic digest of proteins from mouse B16 cells cultured in both natural isotopic abundance and 15N-labeled media. The FTICR mass spectrometric analysis allows the assignment of peptide pairs (corresponding to the two distinctive versions of each peptide), and thus provides the basis for quantiative measurements when one of the two proteomes in the mixture is perturbed or altered in some fashion. We show that implementation of the DREAMS approach allows assignment of approximately 80% more peptide pairs, thus providing quantitative information for approximately 18,000 peptide pairs in a single analysis.  相似文献   

14.
色谱保留时间在蛋白质组研究中的应用   总被引:1,自引:0,他引:1  
邵晨  高友鹤 《色谱》2010,28(2):128-134
液相色谱与串联质谱联用(LC-MS/MS)技术是蛋白质组学研究中的常见方法。保留时间作为独立于质谱信息的参数已经被用于蛋白质的鉴定和定量工作中。在多肽鉴定领域,多肽的色谱保留时间预测与常规的二级串联质谱数据库搜索算法结合可以提高鉴定的可信度。鉴定的灵敏度也可以通过匹配多次LC-MS实验中具有相同精确质量数和保留时间的峰而提高。另一方面,由于色谱条件的微小改变即会引起保留时间的变化,因此对多次实验结果进行保留时间比对是进行非标记定量的不可或缺的步骤。另外,联合保留时间偏移和质量数信息还可以进行蛋白质翻译后修饰(post-translational modification, PTM)的鉴定。  相似文献   

15.
Remarkable advances in mass spectrometry sensitivity and resolution have been accomplished over the past two decades to enhance the depth and coverage of proteome analyses. As these technological developments expanded the detection capability of mass spectrometers, they also revealed an increasing complexity of low abundance peptides, solvent clusters and sample contaminants that can confound protein identification. Separation techniques that are complementary and can be used in combination with liquid chromatography are often sought to improve mass spectrometry sensitivity for proteomics applications. In this context, high‐field asymmetric waveform ion mobility spectrometry (FAIMS), a form of ion mobility that exploits ion separation at low and high electric fields, has shown significant advantages by focusing and separating multiply charged peptide ions from singly charged interferences. This paper examines the analytical benefits of FAIMS in proteomics to separate co‐eluting peptide isomers and to enhance peptide detection and quantitative measurements of protein digests via native peptides (label‐free) or isotopically labeled peptides from metabolic labeling or chemical tagging experiments. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
This paper describes a method--using a combination of LC-MS/MS of selected bacteria-specific peptides and database search--for determining the species of bacteria present in a mixture. We identified the proteotypic peptides that were associated with specific bacteria by searching protein databases for the LC-MS/MS data. The retention time windows for specific peptide markers were used as an extra constraint so that the peptide markers of many bacterial species could be analyzed in a single LC-selective proteotypic-peptide analysis (SPA). We performed LC-MS/MS analyses on the proteolytic digest of cell extracts and monitored only the selected marker peptide ions at given elution time windows. The corresponding bacterial species could be characterized when the selected peptides that eluted at expected elution windows were identified correctly from the database. We managed to identify up to eight bacterial species simultaneously during a single LC-MS/MS analysis, as well as bacteria mixed in various abundances. Two marker ions having similar values of m/z, but obtained from two different bacterial samples, which would otherwise be selected as precursors within mass tolerance and would complicate the MS/MS data, were time-resolved using LC and then used to correctly identify their bacterial sources. The coupling of selective MS/MS monitoring with separation methods, such as LC, provides a highly selective and accurate analytical method for characterizing complex mixtures of bacterial species.  相似文献   

17.
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethylcyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS.  相似文献   

18.
Phosphorylation of protein tyrosine residues regulates many cell functions and has also been proved to be involved in oncogenesis. Thus, the identification of the phosphotyrosine (pTyr) proteome of cells is a very important task. Since tyrosine phosphorylation represents only around 1% of the total human phosphoproteome, the study of pTyr proteins is rather challenging. Here we report the optimization study of the phosphotyrosine proteome using K562 cells as a model system. A substantial segment of the phosphotyrosine proteome of K562 cells was characterized by immunoaffinity enrichment with 4G10 and PYKD1 antibodies followed by LC-MS/MS analysis. 480 non-redundant pTyr peptides corresponding to 342 pTyr proteins were found. 141 pTyr peptides were not described elsewhere. The mass spectrometry approach involving high-resolving FTMS analysis of precursor ions and subsequent detection of CID fragments in a linear ion trap was considered as optimal. For detection of low abundant pTyr peptides pooling of individual immunoaffinity enrichments for one LC-MS/MS analysis was crucial. The enrichment properties of the monoclonal PYKD1 antibody were presented for the first time, also in comparison to the 4G10 antibody. PYKD1 was found to be more effective for protein enrichment (1.2 and 5% efficiency at peptide and protein level correspondingly), while 4G10 showed better results when peptide enrichment was performed (15% efficiency versus 3.6% at protein level). Substantially different subsets of the phosphoproteome were enriched by these antibodies. This finding together with previous studies demonstrates that comprehensive pTyr proteome characterization by immunoprecipitation requires multiple antibodies to be used for the affinity enrichment.  相似文献   

19.
This paper describes an algorithm to apply proteotypic peptide sequence libraries to protein identifications performed using tandem mass spectrometry (MS/MS). Proteotypic peptides are those peptides in a protein sequence that are most likely to be confidently observed by current MS-based proteomics methods. Libraries of proteotypic peptide sequences were compiled from the Global Proteome Machine Database for Homo sapiens and Saccharomyces cerevisiae model species proteomes. These libraries were used to scan through collections of tandem mass spectra to discover which proteins were represented by the data sets, followed by detailed analysis of the spectra with the full protein sequences corresponding to the discovered proteotypic peptides. This algorithm (Proteotypic Peptide Profiling, or P3) resulted in sequence-to-spectrum matches comparable to those obtained by conventional protein identification algorithms using only full protein sequences, with a 20-fold reduction in the time required to perform the identification calculations. The proteotypic peptide libraries, the open source code for the implementation of the search algorithm and a website for using the software have been made freely available. Approximately 4% of the residues in the H. sapiens proteome were required in the proteotypic peptide library to successfully identify proteins.  相似文献   

20.
Targeted tandem mass spectrometry (MS/MS) is an attractive proteomic approach that allows selective identification of peptides exhibiting abundance differences, e.g., between culture conditions and/or diseased states. Herein, we report on a targeted LC-MS/MS capability realized with a hybrid quadrupole-7 tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer that provides data-dependent ion selection, accumulation, and dissociation external to the ICR trap, and a control software that directs intelligent MS/MS target selection based on LC elution time and m/z ratio. We show that the continuous on-the-fly alignment of the LC elution time during the targeted LC-MS/MS experiment, combined with the high mass resolution of FTICR MS, is crucial for accurate selection of targets, whereas high mass measurement accuracy MS/MS data facilitate unambiguous peptide identifications. Identification of a subset of differentially abundant proteins from Shewanella oneidensis grown under suboxic versus aerobic conditions demonstrates the feasibility of such approach.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号