首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Microfluidic adhesion-based cell separation systems are of interest in clinical and biological applications where small sample volumes must be processed efficiently and rapidly. While the ability to capture rare cells from complex suspensions such as blood using microfluidic systems has been demonstrated, few methods exist for rapid and nondestructive release of the bound cells. Such detachment is critical for applications in tissue engineering and cell-based therapeutics in contrast with diagnostics wherein immunohistochemical, proteomic, and genomic analyses can be carried out by simply lysing captured cells. This paper demonstrates how the incorporation of four-arm amine-terminated poly(ethylene glycol) (PEG) molecules along with antibodies within alginate hydrogels can enhance the ability of the hydrogels to capture endothelial progenitor cells (EPCs) from whole human blood. The hydrogel coatings are applied conformally onto pillar structures within microfluidic channels and their dissolution with a chelator allows for effective recovery of EPCs following capture.  相似文献   

2.
沈宏  方群 《化学进展》2008,20(12):2053-2060
微流控分析芯片的微米级结构不仅显著增大内部流体的比界面积,同时缩短微通道内不同溶液间的传质距离,使传质效率相比于宏观体系有显著提高,从而可实现试样分析检测前的高效扩散分离和萃取富集等。本文综述了微流控分析芯片中两种液相传质模式——互溶液相间扩散分离分析、不互溶液相间萃取分离分析的研究进展,讨论了上述传质模式在微芯片装置和功能的集成化方面的应用;并讨论了相关研究的难点和发展趋势。  相似文献   

3.
Microfluidic particle focusing has been a vital prerequisite step in sample preparation for downstream particle separation, counting, detection, or analysis, and has attracted broad applications in biomedical and chemical areas. Besides all the active and passive focusing methods in Newtonian fluids, particle focusing in viscoelastic fluids has been attracting increasing interest because of its advantages induced by intrinsic fluid property. However, to achieve a well-defined focusing position, there is a need to extend channel lengths when focusing micrometer-sized or sub-microsized particles, which would result in the size increase of the microfluidic devices. This work investigated the sheathless viscoelastic focusing of particles and cells in a zigzag microfluidic channel. Benefit from the zigzag structure of the channel, the channel length and the footprint of the device can be reduced without sacrificing the focusing performance. In this work, the viscoelastic focusing, including the focusing of 10 μm polystyrene particles, 5 μm polystyrene particles, 5 μm magnetic particles, white blood cells (WBCs), red blood cells (RBCs), and cancer cells, were all demonstrated. Moreover, magnetophoretic separation of magnetic and nonmagnetic particles after viscoelastic pre-focusing was shown. This focusing technique has the potential to be used in a range of biomedical applications.  相似文献   

4.
Yang M  Yang J  Li CW  Zhao J 《Lab on a chip》2002,2(3):158-163
We have developed a simple method to generate a concentration gradient in a microfluidic device. This method is based on the combination of controlled fluid distribution at each intersection of a microfluidic network by liquid pressure and subsequent diffusion between laminas in the downstream microchannel. A fluid dynamic model taking into account the diffusion coefficient was established to simulate the on-chip flow distribution and diffusion. Concentration gradients along a distance of a few hundred micrometers were generated in a series of microchannels. The gradients could be varied by carefully regulating the liquid pressure applied to the sample injection vials. The observed concentration gradients of fluorescent dyes generated on the microfluidic channel are consistent with the theoretically predicted results. The microfluidic design described in this study may provide a new tool for applications based on concentration gradients, including many biological and chemical analyses such as cellular reaction monitoring and drug screening.  相似文献   

5.
Microfluidics technology for manipulation and analysis of biological cells   总被引:1,自引:0,他引:1  
Analysis of the profiles and dynamics of molecular components and sub-cellular structures in living cells using microfluidic devices has become a major branch of bioanalytical chemistry during the past decades. Microfluidic systems have shown unique advantages in performing analytical functions such as controlled transportation, immobilization, and manipulation of biological molecules and cells, as well as separation, mixing, and dilution of chemical reagents, which enables the analysis of intracellular parameters and detection of cell metabolites, even on a single-cell level. This article provides an in-depth review on the applications of microfluidic devices for cell-based assays in recent years (2002–2005). Various cell manipulation methods for microfluidic applications, based on magnetic, optical, mechanical, and electrical principles, are described with selected examples of microfluidic devices for cell-based analysis. Microfluidic devices for cell treatment, including cell lysis, cell culture, and cell electroporation, are surveyed and their unique features are introduced. Special attention is devoted to a number of microfluidic devices for cell-based assays, including micro cytometer, microfluidic chemical cytometry, biochemical sensing chip, and whole cell sensing chip.  相似文献   

6.
7.
Biomolecular gradients in cell culture systems   总被引:3,自引:0,他引:3  
Biomolecule gradients have been shown to play roles in a wide range of biological processes including development, inflammation, wound healing, and cancer metastasis. Elucidation of these phenomena requires the ability to expose cells to biomolecule gradients that are quantifiable, controllable, and mimic those that are present in vivo. Here we review the major biological phenomena in which biomolecule gradients are employed, traditional in vitro gradient-generating methods developed over the past 50 years, and new microfluidic devices for generating gradients. Microfluidic gradient generators offer greater levels of precision, quantitation, and spatiotemporal gradient control than traditional methods, and may greatly enhance our understanding of many biological phenomena. For each method, we outline the salient features, capabilities, and applications.  相似文献   

8.
Liu Y  Lim KM 《Lab on a chip》2011,11(18):3167-3173
We present a new method for separation of micro-sized constituents with positive acoustic contrast factors in a microfluidic channel using ultrasound. The ultrasound field is switched between the first and third resonant modes of the fluid channel, and the suspended constituents are separated onto the side and center pressure nodal lines according to their sizes or acoustic contrast factors. Initial hydrodynamic focusing of the constituents within a region of the channel near to the side nodal line is a crucial step in this separation method. This new method is shown to provide a novel "parallel-stream" separation of two species of particles with good robustness. Prior numerical simulations provide essential information on this operating region and also the voltage cycle to be applied to the ultrasonic actuators for optimal separation. Experiments were conducted using a prototype of the design with polystyrene microspheres of different sizes to demonstrate the efficiency and robustness of the separation process.  相似文献   

9.
Concentration gradient and fluid shear stress(FSS) for cell microenvironment were investigated through microfluidic technology. The Darcy–Weisbach equation combined with computational fluid dynamics modeling was exploited to design the microfluidic chip, and the FSS distribution on the cell model with varying micro-channels(triangular, conical, and elliptical). The diffusion with the incompressible laminar flow model by solving the time-dependent diffusion–convection equation was applied to simu...  相似文献   

10.
Microfluidic technologies are emerging as an enabling tool for various applications in tissue engineering and cell biology. One emerging use of microfluidic systems is the generation of shape-controlled hydrogels (i.e., microfibers, microparticles, and hydrogel building blocks) for various biological applications. Furthermore, the microfluidic fabrication of cell-laden hydrogels is of great benefit for creating artificial scaffolds. In this paper, we review the current development of microfluidic-based fabrication techniques for the creation of fibers, particles, and cell-laden hydrogels. We also highlight their emerging applications in tissue engineering and regenerative medicine.  相似文献   

11.
Microfluidic device for capillary electrochromatography-mass spectrometry   总被引:2,自引:0,他引:2  
Lazar IM  Li L  Yang Y  Karger BL 《Electrophoresis》2003,24(21):3655-3662
A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.  相似文献   

12.
Summary An interface described in the literature was modified to accommodate small sample quantities. The simple and inexpensive method can be used to obtain rapid qualitative sample information of complex matrices by extraction in sub- or supercritical conditions (SFE) with a concurrent separation by capillary supercritical fluid chromatography (CSFC). Compared to traditional solvent extraction methods the potential for analyte degradation and contamination is minimized resulting in reduced sample amount necessary for extraction and separation, and also in faster extractions. Complex matrices of a plastic material, a natural product and a soil spiked with a substituted hydrocarbon test mixture were analyzed to show the usefulness of the interface.  相似文献   

13.
李海芳  张倩云  林金明 《色谱》2011,29(4):284-292
微流控芯片具有液流可控、样品消耗量小、反应速度快、易于集成化等特点,在临床诊断和疾病筛查领域具有广阔的发展前景。本文针对近年来微流控芯片技术在疾病诊断方面的最新研究进展,从疾病标志物检测、细胞筛选和药物代谢研究及疾病诊断微流控芯片装置的发展现状等方面概述其在疾病诊断方面的应用和发展。  相似文献   

14.
Microfluidic chip electrophoresis has been widely employed for separation of various biochemical species owing to its advantages of low sample consumption, low cost, fast analysis, high throughput, and integration capability. In this article, we reviewed the development of four different modes of microfluidics‐based electrophoresis technologies including capillary electrophoresis, gel electrophoresis, dielectrophoresis, and field (electric) flow fractionation. Coupling detection schemes on microfluidic electrophoresis platform were also reviewed such as optical, electrochemical, and mass spectrometry method. We further discussed the innovative applications of microfluidic electrophoresis for biomacromolecules (nucleic acids and proteins), biochemical small molecules (amino acids, metabolites, ions, etc.), and bioparticles (cells and pathogens) analysis. The future direction of microfluidic chip electrophoresis was predicted.  相似文献   

15.
Microfluidic systems promise solutions for high throughput and highly specific analysis for biology, medicine and chemistry while consuming only tiny amounts of reactants and space. On these lab‐on‐a‐chip platforms often multiple physical effects such as electrokinetic, acoustic or capillary phenomena from various disciplines are exploited to gain the optimal functionality. The fluidics on these small length scales differ significantly from our experience of the macroscopic world. In this Review we survey some of the approaches and techniques to handle minute amounts of fluid volumes in microfluidic systems with special focus on surface acoustic wave driven fluidics, a technique developed in our laboratory. Here, we outline the basics of this technique and demonstrate, for example, how acoustic mixing and fluid actuation is realized. Furthermore we discuss the interplay of different physical effects in microfluidic systems and illustrate their usefulness for several applications.  相似文献   

16.
Molecular simulation calculations are presented for two types of complex fluid mixtures, namely elastomer polymer mixtures and water–1-octanol binary and ternary mixtures. Elastomer polymers are used widely as membrane materials for gas separation. In this respect, the solubility and diffusion coefficient of gases need to be known accurately. Predictions for both properties are presented here. Water–1-octanol mixture is a widely used prototype system used to assess the partitioning of various chemical compounds with applications to chemical industry, biotechnology, etc. The microscopic structure of the water–1-octanol mixture is examined and the Gibbs free energy of solvation of four organic solutes is calculated. In all cases, detailed atomistic force fields are used to account for inter- and intra-molecular interactions. Simulation results are shown to be in excellent agreement with literature experimental data.  相似文献   

17.
We describe and characterize a pumping mechanism that leverages the momentum present in small droplets ejected from a micro-nozzle to drive flow in an open microfluidic device. This approach allows driving flow in a microfluidic device in a regime that offers unique features different to those achievable with typical passive pumping or syringe-pump driven flow. Two flow regimes with specific flow characteristics are described: inertia enhanced passive pumping, in which fluid exchange times in the channel are significantly reduced, and inertia actuated flow, in which it is possible to initiate flow in an empty channel or against natural pressure gradients. Momentum is leveraged to create rapid fluid exchanges, instantaneous flow reversal, filling and mixing inside the microfluidic device.  相似文献   

18.
Microfluidic devices have found a unique place in cellular studies due to the ease of fabrication, their ability to provide long-term culture, or the seamless integration of downstream measurements into the devices. The accurate and precise control of fluid flows also allows unique stimulant profiles to be applied to cells that have been difficult to perform with conventional devices. In this review, we describe and provide examples of microfluidic systems that have been used to generate temporal gradients of stimulants, such as waveforms or pulses, and how these profiles have been used to produce biological insights into mammalian cells that are not typically revealed under static concentration gradients. We also discuss the inherent analytical challenges associated with producing and maintaining temporal gradients in these devices.  相似文献   

19.
Xiangchun Xuan 《Electrophoresis》2019,40(18-19):2484-2513
Microfluidic devices have been extensively used to achieve precise transport and placement of a variety of particles for numerous applications. A range of force fields have thus far been demonstrated to control the motion of particles in microchannels. Among them, electric field‐driven particle manipulation may be the most popular and versatile technique because of its general applicability and adaptability as well as the ease of operation and integration into lab‐on‐a‐chip systems. This article is aimed to review the recent advances in direct current (DC) (and as well DC‐biased alternating current) electrokinetic manipulation of particles for microfluidic applications. The electric voltages are applied through electrodes that are positioned into the distant channel‐end reservoirs for a concurrent transport of the suspending fluid and manipulation of the suspended particles. The focus of this review is upon the cross‐stream nonlinear electrokinetic motions of particles in the linear electroosmotic flow of fluids, which enable the diverse control of particle transport in microchannels via the wall‐induced electrical lift and/or the insulating structure‐induced dielectrophoretic force.  相似文献   

20.
Microfluidic devices are currently being used in many types of biochemical microsystems for liquid phase analysis in the frame of medical applications. This paper presents a new technique for the realization of microfluidic channels using SU-8, a commonly used epoxy-based negative photo-resist. These microchannels were fabricated by a single stepper UV-photolithography process. By changing the process parameters, e.g. the optical focus depth and the UV exposure dose, well-defined, covered microchannels with various dimensions and aspect ratios were realized and proven to be effective for the fluid transport by capillarity. This technique can easily be used for the fabrication of microfluidic devices in the microanalysis and lab-on-chip applications realm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号