首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The structure of nanoparticles typically differs from its bulk counterpart. Predominantly, the structures of gold nanoparticles have been under exceedingly intense discussion since the discovery of their high catalytic activity. We found an increasing bond length contraction with decreasing particle size for citrate-stabilized gold nanoparticles in aqueous solution as determined by in situ extended X-ray absorption fine structure (EXAFS) spectroscopy. Particle sizes and size distributions were determined by small-angle X-ray scattering. The analysis of the obtained EXAFS spectra employing ab initio calculations reveals that the Au–Au bond length undergoes a contraction of 2 pm for nanoparticles with a radius of 2.9 nm. NIST reference material RM 8011 gold nanoparticles with a radius of 4.4 nm exhibit a smaller contraction of approximately 1 pm. Finally, gold atoms in RM 8013 particles with a radius of 25.7 nm show distances of 288 pm—identical to the distance in gold foil—and exhibits bulk-like properties. The observed bond length contraction of gold nanoparticles in solution is significantly smaller than previously reported for gold nanoparticle deposited on surfaces, which is up to 15 pm. This indicates that the bond length contraction effect of “free” and “surface-immobilized” nanoparticles differ fundamentally. Such difference could be essential for the understanding of nanoparticle-supported catalysis.  相似文献   

2.
Microwave digestion and isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-SFMS) has been applied to the determination of Pb in rice flour. In order to achieve highly precise determination of low concentrations of Pb, the digestion blank for Pb was reduced to 0.21 ng g−1 after optimization of the digestion conditions, in which 20 mL analysis solution was obtained after digestion of 0.5 g rice flour. The observed value of Pb in a non-fat milk powder certified reference material (CRM), NIST SRM 1549, was 16.8 ± 0.8 ng g−1 (mean ± expanded uncertainty, k = 2; n = 5), which agreed with the certified value of 19 ± 3 ng g−1 and indicated the effectiveness of the method. Analytical results for Pb in three brown rice flour CRMs, NIST SRM 1568a, NIES CRM 10-a, and NIES CRM 10-b, were 7.32 ± 0.24 ng g−1 (n = 5), 1010 ± 10 ng g−1 (n = 5), and 1250 ± 20 ng g−1 (n = 5), respectively. The concentration of Pb in a candidate white rice flour reference material (RM) sample prepared by the National Metrology Institute of Japan (NMIJ) was observed to be 4.36 ± 0.28 ng g−1 (n = 10 bottles). Figure Digestion blank of Pb was carefully reduced to approximately 0.2 ng g-1 which permitted the highly precise determination of Pb at low ng g-1 level in foodstuff samples by ID-SFMS  相似文献   

3.
In this work, we used a model assay system (polyclonal human IgG–goat antihuman IgG) to elucidate some of the key factors that influence the analytical performance of bioassays that employ metal-enhanced fluorescence (MEF) using silver nanoparticles (NPs). Cy5 dye was used as the fluorescent label, and results were compared with a standard assay performed in the absence of NPs. Two sizes of silver NPs were prepared with respective diameters of 60 ± 10 and 149 ± 16 nm. The absorption spectra of the NPs in solution were fitted accurately using Mie theory, and the dipole resonance of the 149-nm NPs in solution was found to match well with the absorption spectrum of Cy5. Such spectral matching is a key factor in optimizing MEF. NPs were deposited uniformly and reproducibly on polyelectrolyte-coated polystyrene substrates. Compared to the standard assay performed without the aid of NPs, significant improvements in sensitivity and in limit of detection (LOD) were obtained for the assay with the 149-nm NPs. An important observation was that the relative enhancement of fluorescence increased as the concentration of antigen increased. The metal-assisted assay data were analyzed using standard statistical methods and yielded a LOD of 0.086 ng/mL for the spectrally matched NPs compared to a value of 5.67 ng/mL obtained for the same assay in the absence of NPs. This improvement of ∼66× in LOD demonstrates the potential of metal-enhanced fluorescence for improving the analytical performance of bioassays when care is taken to optimize the key determining parameters.   相似文献   

4.
A multianalyte lateral-flow immunochromatographic technique using colloidal gold-labeled polyclonal antibodies was developed for the rapid simultaneous detection of clenbuterol and ractopamine. The assay procedure could be accomplished within 5 min, and the results of this qualitative one-step assay were evaluated visually according to whether test lines appeared or not. When applied to the swine urines, the detection limit and the half maximal inhibitory concentration (IC50) of the test strip under an optical density scanner were calculated to be 0.1 ± 0.01 ng mL−1 and 0.1 ± 0.01 ng mL−1, 0.56 ± 0.08 ng mL−1, and 0.71 ± 0.06 ng mL−1, respectively, the cut-off levels with the naked eye of 1 ng mL−1 and 1 ng mL−1 for clenbuterol and ractopamine were observed. Parallel analysis of swine urine samples with clenbuterol and ractopamine showed comparable results obtained from the multianalyte lateral-flow test strip and GC-MS. Therefore, the described multianalyte lateral-flow test strip can be used as a reliable, rapid, and cost-effective on-site screening technique for the simultaneous determination of clenbuterol and ractopamine residues in swine urine.   相似文献   

5.
6.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection for the quantification of vancomycin in human plasma was developed and validated. The method includes an extraction of vancomycin by deproteinization with acetonitrile. The analyses were carried out at 258 nm as the emission wavelength while exciting at 225 nm on a reversed-phase column (30 cm × 4 mm i.d. × 10 μm Waters Associates μBondapak C18) using a mobile phase composed of methanol and phosphate buffer at pH 6.3. Vancomycin was quantitatively recovered from human plasma samples (>96%) with high values of precision. The separation was completed within 27 min. The calibration curve was linear over the range from 5 to 1,000 ng/mL with the detection and quantification limits of 2 ng/mL and 5 ng/mL, respectively. This method is suitable for the routine assay of plasma samples. Figure The effect of the deproteinization solvent on the signal of the interference peak at retention time of 15.0 min. The peak which interferes with the peaks of Erythromycin and Vancomycin has been disappeared by using 2 mL acetonitrile as the deproteinization solvent.  相似文献   

7.
A method for determining the size of silver nanoparticles and their quantification by asymmetric flow field-flow fractionation coupled with inductively coupled plasma mass spectrometry (ICP-MS) is proposed and was tested in consumer products. Experimental conditions were studied in detail to avoid aggregation processes or alteration of the original size distributions. Additionally, losses from sorption processes onto the channel membrane were minimized for correct quantification of the nanoparticles. Mobile phase composition, injection/focusing, and fractionation conditions were evaluated in terms of their influence on both separation resolution and recovery. The ionic strength, pH, and the presence of ionic and nonionic surfactants had a strong influence on both separation and recovery of the nanoparticles. In general, better results were obtained under those conditions that favored charge repulsions with the membrane. Recovery values of 83 ± 8% and 93 ± 4% with respect to the content of silver nanoparticles were achieved for the consumer products studied. Silver nanoparticle standards were used for size calibration of the channel. The results were compared with those obtained by photon correlation spectroscopy and images taken by transmission electron microscopy. The quantification of silver nanoparticles was performed by direct injection of ionic silver standard solutions into the ICP-MS system, integration of the corresponding peaks, and interpolation of the fractogram area. A limit of detection of 5.6 μg L-1 silver, which corresponds to a number concentration of 1×1012 L-1 for nanoparticles of 10 nm, was achieved for an injection volume of 20 μL.  相似文献   

8.
Radix Scrophulariae (Xuanshen) is one of the famous Chinese herbal medicines widely used to treat rheumatism, tussis, pharyngalgia, arthritis, constipation, and conjunctival congestion. Harpagoside and cinnamic acid are the main bioactive components of Xuanshen. The purpose of this study was to develop an HPLC–UV method for simultaneous determination of harpagoside and cinnamic acid in rat plasma and investigate pharmacokinetic parameters of harpagoside and cinnamic acid after oral administration of Xuanshen extract (760 mg kg−1). After addition of syringin as internal standard, the analytes were isolated from plasma by liquid–liquid extraction. Separation was achieved on a Kromasil C18 column, and detection was by UV absorption at 272 nm. The described assay was validated in terms of linearity, accuracy, precision, recovery, and limit of quantification according to the FDA validation guidelines. Calibration curves for both analytes were linear with the coefficient of variation (r) for both was greater than 0.999. Accuracy for harpagoside and cinnamic acid ranged from 100.7–103.5% and 96.9–102.9%, respectively, and precision for both analytes were less than 8.5%. The main pharmacokinetic parameters found for harpagoside and cinnamic acid after oral infusion of Xuanshen extract were as follows: C max 1488.7 ± 205.9 and 556.8 ± 94.2 ng mL−1, T max 2.09 ± 0.31 and (1.48 ± 0.14 h, AUC0–24 10336.4 ± 1426.8 and 3653.1 ± 456.4 ng h mL−1, 11276.8 ± 1321.4 and 3704.5 ± 398.8 ng h mL−1, and t 1/2 4.9 ± 1.3 and 2.5 ± 0.9 h, respectively. These results indicated that the proposed method is simple, selective, and feasible for pharmacokinetic study of Radix Scrophulariae extract in rats. Figure Radix Scrophulariae  相似文献   

9.
Polychloromethylstyrene nanoparticles of sizes from 12.0 ± 2.3 to 229.6 ± 65 nm were prepared by the emulsion and miniemulsion polymerization of chloromethylstyrene in an aqueous continuous phase in the presence of potassium persulfate as initiator, sodium octylbenzenesulfonate as surfactant, and hexadecane as costabilizer for the miniemulsion polymerization process only. The influence of various polymerization parameters (e.g., concentration of the monomer, initiator, the crosslinker monomer, and the surfactant) on the properties of the particles (e.g., size, size distribution, and yield) has been elucidated. The polychloromethylstyrene nanoparticles formed via the emulsion polymerization mechanism possess smaller diameter and size distribution than those formed under similar conditions via the miniemulsion polymerization mechanism. Other differences between these two polymerization mechanisms have also been elucidated. For future study, we wish to use these nanoparticles for the covalent immobilization of bioactive reagents such as proteins to the surface of these nanoparticles for various biomedical applications.  相似文献   

10.
Two kinds of Ca2+-regulated photoprotein obelin with altered color of bioluminescence were obtained by active-center amino acid substitution. The mutant W92F-H22E emits violet light (λmax = 390 nm) and the mutant Y139F emits greenish light (λ max = 498 nm), with small spectral overlap, both display high activity and stability and thus may be used as reporters. For demonstration, the mutants were applied in dual-color simultaneous immunoassay of two gonadotropic hormones—follicle-stimulating hormone and luteinizing hormone. Bioluminescence of the reporters was simultaneously triggered by single injection of Ca2+ solution, divided using band-pass optical filters and measured with a two-channel photometer. The sensitivity of simultaneous bioluminescence assay was close to that of a separate radioimmunoassay. Figure Two kinds of Ca2+-regulated photoprotein obelin with altered color of bioluminescence were obtained and applied in dual-color simultaneous immunoassay of two gonadotropic hormones.  相似文献   

11.
Malachite green oxalate (MG oxalate) and leucomalachite green (LMG) have been prepared and certified as pure reference materials. The purities of MG oxalate and LMG were assessed by high-performance liquid chromatography–diode array detection (HPLC–DAD), nuclear magnetic resonance (NMR) spectroscopy, differential scanning calorimetry (DSC), Karl Fischer titration, ashing and thermogravimetric analysis (TGA). MG oxalate was purified by supercritical fluid extraction (SFE). Prior to purification, commercial MG oxalate purity was estimated to be about 90%. The main impurities present in SFE-purified MG oxalate were identified and quantified using HPLC–DAD. The main impurities were found to be monode-MG (monodemethylated MG oxalate synthesis impurity), 4-(dimethylamino)benzophenone (4-DMABP), MG-carbinol and LMG. The homogeneity of both reference materials was also determined. Issues associated with the stability of LMG and MG oxalate in solution forced an extensive study investigating different parameters i.e. solvent, acid, analyte concentration and temperature. MG oxalate (100 μg/mL) was found to be stable in acetonitrile containing 1% v/v glacial acetic acid for at least 155 days and LMG (100 μg/mL) was stable in acetonitrile for at least 133 days. The final purity value for MG oxalate was 94.3 ± 1.4% m/m at the 95% confidence interval (or 67% m/m if MG cation is reported). For LMG, the certified purity was found to be 98.8 ± 0.8% m/m at the 95% confidence interval. Figure Calibration reference materials for malachite green and leucomalachite green, certified for purity, are essential in characterising these key analytes in a fish matrix reference material  相似文献   

12.
We have developed a circular-dichroism thermal lens microscope for UV wavelengths (UV-CD-TLM), for the first time, to realize sensitive chiral analysis on a microchip. Quasi-continuous-wave phase modulation of a pulsed UV laser was used to generate left-circularly polarized light and right-circularly polarized light and to detect the generated TL signal amplitude and phase with a lock-in amplifier. The amplitude and phase were used to determine the concentration and chirality, respectively, of a sample. The basic principle of UV-CD-TLM for chiral analysis on a microchip was verified by measuring aqueous solutions of optically active camphorsulfonic acids (CSA). Lower limits of detection (LOD) were calculated at S/= 2 and were 8.7 × 10−4 mol L−1A = 5.2 × 10−6 Abs.) for (+)-CSA and 8.4 × 10−4 mol L−1A = 5.0 × 10−6 Abs.) for (−)-CSA. In terms of number of molecules, LODs for UV-CD-TLM were calculated to be 8.7 fmol and 8.4 fmol, respectively. This is at least three orders of magnitude lower than previously obtained. The applicability of UV-CD-TLM for chiral analysis on a microchip was verified. Figure Sensitive chiral analysis by thermal lens microscope (TLM)  相似文献   

13.
This paper describes a method for polypyrrole (PPy) coating of metallic Cu nanoparticles in aqueous solution in atmosphere. Colloid solution of Cu nanoparticles was prepared by reducing Cu ions with the use of hydrazine in an aqueous solution dissolving citric acid and cetyltrimethylammonium bromide as stabilizers. The PPy coating was performed by polymerizing pyrrole with the use of hydrogen peroxide as an initiator in an aqueous colloid solution of the Cu nanoparticles. Ultraviolet–visible extinction measurements, transmission electron microscopy observation, and X-ray diffraction measurements revealed that the metallic Cu nanoparticles with a size of 27.6 ± 11.1 nm were coated with PPy. The obtained PPy-coated Cu particles were chemically stable even in atmosphere.  相似文献   

14.
In the present study, a new fluorescence microplate screening assay for evaluating scavenging activity against singlet oxygen (1O2) was implemented. The chemical generation of 1O2 was promoted using the thermodissociable endoperoxide of disodium 3,3′-(1,4-naphthalene)bispropionate (NDPO2). The detection of 1O2 was achieved using dihydrorhodamine 123 (DHR), a nonfluorescent molecule that is oxidizable to the fluorescent form rhodamine 123 (RH). The combined use of a 1O2-selective generator and a highly sensitive probe (DHR) was then successfully applied to perform a screening assay of the 1O2 scavenging activities of ascorbic acid, penicillamine, cysteine, N-acetylcysteine (NAC), methionine, reduced glutathione (GSH), dihydrolipoic acid, lipoic acid, and sodium azide. All of these antioxidants exhibited concentration-dependent 1O2 scavenging capacities. They could be ranked according to observed activity: ascorbic acid> cysteine> penicillamine> dihydrolipoic acid > GSH> NAC> sodium azide> lipoic acid (IC50 values of 3.0 ± 0.2, 8.0 ± 0.7, 10.9 ± 0.8, 25.2 ± 4.5, 57.4 ± 5.9, 138 ± 13, 1124 ± 128, 2775 ± 359 μM, mean±SEM, respectively) > methionine (35% of scavenging effect at 10 mM). In conclusion, the use of NDPO2 as a selective generator for 1O2 and its fluorescence detection by the highly sensitive probe DHR is shown to be a reliable and resourceful analytical alternative means to implement a microplate screening assay for scavenging activity against 1O2. Generation and detection of singlet oxygen  相似文献   

15.
The worldwide contamination of winery by-products by mycotoxins may present a serious hazard to human and animal health. Mycotoxins are secondary metabolites of fungi with possible adverse effects on humans, animals, and crops that result in illnesses and economic losses. Mycotoxins are under continuous survey in Europe, but the regulatory aspects still need to be set up for winery by-products, which may be used in animal feed. The aim of this study was to implement a simple but reliable analytical methodology for ochratoxin A (OTA) quantification in grape pomaces in order to perform a survey of samples from the Douro Demarcated Region, Portugal. The method involved a unique preparation step, solvent extraction, followed by high-performance liquid chromatography (HPLC) with fluorescence (FL) detection. A comparative study was performed with two extraction solvents (ethyl acetate and methanol) as well as using extraction on an immunoaffinity column. The linearity range for OTA analysis was 0.05–23.5 μg L−1 with a detection limit of 0.05 μg L−1 and a precision (expressed by the coefficient of variation under repeatability conditions) of 0.4–14.7%. The percentage of recovery was on average 23.5 ± 3.6% (extraction with ethyl acetate) or 70.1 ± 2.5% (extraction with 70% methanol). Accounting for the recovery factor and the chromatographic detection limit, as well as the preconcentration factor, the limit of detection in grape pomaces is 0.04 μg kg−1 (ethyl acetate extraction) and 0.33 μg kg−1 (methanol extraction). Samples from 12 out of 13 sites in the Douro Demarcated Region showed OTA presence with concentrations not exceeding 0.4 μg kg−1. Both developed methods for evaluation of OTA in grape pomace are simple but efficient. Figure Extraction of ochratoxin A (OTA) from grape pomaces allows simple but efficient quantification of OTA in winery by-products by HPLC-FL  相似文献   

16.
A novel electrochemical sensor for methyl parathion based on silicate– cetyltrimethylammonium bromide nanocomposite film has been fabricated by electro-assisted deposition onto glassy carbon electrode in one-step via an electrochemical modulation of pH at the electrode/solution interface to promote controlled gelification of tetraethylorthosilicate sol, and was characterized with scanning electron microscopy, X-ray diffraction, and electrochemical impedance spectroscopy. The electrochemical sensing of methyl parathion on the film-modified electrode was investigated applying cyclic voltammetry and square wave voltammetry. Compared to the unmodified electrode, the shapes of the redox peaks were improved and the peak currents significantly increased. Experimental parameters such as deposition time, pH value, and accumulation conditions have been optimized. A linear relationship between the peak current and methyl parathion concentration was obtained in the range from 1.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.04 × 10 −8 mol L−1 (S/N = 3) after accumulation at 0 V for 120 s. The film electrode shows great promise for determination of methyl parathion in real samples.   相似文献   

17.
Isotope ratio measurements characterizing 202Hg/200Hg in NIST SRM 3133 Mercury Standard Solution were undertaken by multicollector inductively coupled plasma mass spectrometry employing NIST SRM 997 Tl for mass bias correction by use of the slope and the intercept obtained from a natural logarithmic plot of each session of measurements of 202Hg/200Hg against 205Tl/203Tl. The calculated value of 1.285333 ± 0.000192 (mean and one standard deviation, n = 40) for the mass bias corrected 202Hg/200Hg was then used for mass bias correction of other Hg isotope pairs. Ratios of 0.015337 ± 0.000011, 1.68770 ± 0.00054, 2.3056 ± 0.0015, 1.3129 ± 0.0013, 2.9634 ± 0.0038, and 0.67937 ± 0.0013 (expanded uncertainty, k = 2) were obtained for 196Hg/198Hg, 199Hg/198Hg, 200Hg/198Hg, 201Hg/198Hg, 202Hg/198Hg, and 204Hg/198Hg, respectively. Reduction of Hg(II) to Hg0 in solutions of SRM 3133 was then undertaken using SnCl2, NaBH4, UV photolysis in the presence of formic acid, and ethylation of Hg(II) using NaBEt4. These reactions induced significant isotope fractionation with maximum values of 1.17 ± 0.07, 1.08 ± 0.09, 1.34 ± 0.07, and 3.59 ± 0.09‰ (one standard deviation, 1SD, n = 5) for δ 202/198Hg relative to the initial isotopic composition in the solution following 85–90% reduction of the Hg by SnCl2, NaBH4, UV photolysis, and ethylation with NaBEt4, respectively. Mass-dependent fractionation was found to be dominant for all reduction processes. Figure Mass dependence of fractionation for all samples from Hg fractionation experiments using NaBEt4. Solid lines are the theoretically predicted MDF based on δ202/198 Hg using equation 7. Error bars displayed are one standard deviation of the mean of 5 measurements of each sample  相似文献   

18.
Conductive spherical polypyrrole nanoparticles were obtained by polymerization in oil-in-water (o/w) microemulsions using sodium dodecyl sulfate (SDS) as anionic surfactant, ethanol as co-surfactant, and potassium persulfate (KPS, 0.017 wt.%) as oxidizing agent. The average particle diameter (Dp) of the nanoparticles was between 38 and 45 nm with narrow particle size distributions (D w/D n < 1.2). Dp increases with the ethanol concentration due to the intercalation between the polar heads of SDS, promoting instability of the nanoparticles and some coagulation. In this work, low surfactant concentration was used, and the molar ratio of the oxidizing agent to monomer was 8.5 × 10−3, a value much lower compared with others reported in the literature. Increasing the ethanol concentration in the recipes enhanced the conductive properties of the polymers due to the high π-conjugation length obtained.  相似文献   

19.
We report the analytical and in vitro antibacterial activity of glucosamine-functionalized silver glyconanoparticles. Morphological characterization ensured the surface topography and particle size distribution of both silver and glucosamine–silver nanoparticles. Surface plasmon resonance of both types of nanoparticle was determined from UV–visible spectroscopy using four different sample concentrations (10–40 μL). The resulting functionalized glyconanoparticles show maximum absorbance with a red shift of 30 ± 5 nm (390–400 nm) from their initial absorbance (425–430 nm). FT-Raman and 1H-NMR spectroscopic measurement confirmed the surface functionalization of glucosamine on the silver surface through the carbonyl group of a secondary amide linkage (–NH–CO–), elucidated by the conjugation of N-hydroxysuccinimide (NHS)-terminated silver nanoparticles and the amino group of glucosamine. Antimicrobial experiments with well-characterized silver nanoparticles (AgNPs) and glucosamine-functionalized silver nanoparticles (GlcN-AgNPs) demonstrate that GlcN-AgNPs have similar and enhanced minimum inhibitory concentration (MIC) against eight gram-negative and eight gram-positive bacteria compared with AgNPs. MIC data shows that Klebsiella pneumoniae (ATCC 700603) and Bacillus cereus isolate express high levels of inhibition, with the quantity and magnitude of inhibition being higher in the presence of GlcN-AgNPs.  相似文献   

20.
The discrimination and classification of allergy-relevant pollen was studied for the first time by mid-infrared Fourier transform infrared (FT-IR) microspectroscopy together with unsupervised and supervised multivariate statistical methods. Pollen samples of 11 different taxa were collected, whose outdoor air concentration during the flowering time is typically measured by aerobiological monitoring networks. Unsupervised hierarchical cluster analysis provided valuable information about the reproducibility of FT-IR spectra of the same taxon acquired either from one pollen grain in a 25 × 25 μm2 area or from a group of grains inside a 100 × 100 μm2 area. As regards the supervised learning method, best results were achieved using a K nearest neighbors classifier and the leave-one-out cross-validation procedure on the dataset composed of single pollen grain spectra (overall accuracy 84%). FT-IR microspectroscopy is therefore a reliable method for discrimination and classification of allergenic pollen. The limits of its practical application to the monitoring performed in the aerobiological stations were also discussed. Figure Traditional and innovative methods for the identification of airborne pollen grains  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号