首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A highly selective immunoaffinity column was obtained by coupling anti-papaverine polyclonal antibodies to CNBr-activated Sepharose 4B. It was found that the coupling efficiency and performance of the immunoaffinity column were greatly improved by prolonging the coupling reaction time from 3 h at 20 degrees C with shaking to incubation overnight at 4 degrees C after the 3 h shaking reaction. The pH and ionic strength were observed to be the most important factors that influence the binding of papaverine to the immunoaffinity column. Using 0.01 mol/L phosphate buffered saline (PBS, pH 8.3) and methanol-water (80:20, v/v) as the loading and eluting solutions, respectively, papaverine was first retained on the column and then quantitatively eluted out with a mean recovery of 86% at a loading concentration of 1 microg/mL. When applied to real samples of pericarpium papaveris and food products, the established immunoaffinity column showed high efficiency in removing the matrix interferences in the samples and satisfactory recovery results were obtained. The method was useful for extraction and purification of papaverine from related samples.  相似文献   

2.
An immunoaffinity column for the selective extraction and concentration of the herbicide triclopyr from water samples and quantification on line by HPLC has been developed. The immunoaffinity device was prepared by immobilising triclopyr antibodies to hydrazide derivatized azlactona beds. Efficient desorption of bound triclopyr was achieved with 70% ethanol/water solution. The column was evaluated regarding selectivity, recovery, capacity, saturation volume and reusability. Obtained results show that immunoaffinity chromatography (IAC) can be used for quantitative extraction, concentration and determination of triclopyr from water samples.  相似文献   

3.
An immunoaffinity chromatographic (IAC) method for isolating sulfamethazine (SMZ) from incurred urine samples was developed. This was achieved by (i) generating polyclonal antibodies that recognize equally well SMZ and its major urinary metabolites, (ii) evaluating in an ELISA procedure the influence of methanol, salt and pH on the antigen-antibody interaction in order to determine the optimum conditions for IAC and (iii) covalent coupling of the IgG fractions of anti-SMZ to CNBr activated Sepharose for the preparation of re-usable immunoaffinity columns, having a high capacity for SMZ (1900 ng SMZ mL-1 gel). For desorbing SMZ from the immunoaffinity column, different elution modes were evaluated, with 40% MeOH-0.1 mol L-1 HOAc-0.5 mol L-1 NaCl being the most efficient combination. Using the IAC column for processing SMZ spiked urine samples resulted in high recoveries, ranging from 92 to 100%. Because of the high cross-reactivity with the major metabolites of SMZ present in urine of treated animals, the antibodies show excellent properties for use in both IAC and ELISA. For the isolation and concentration of the parent drug and its major metabolites, the urine could be applied directly to the IAC column, without the time-consuming step of deconjugation. Moreover, the use of IAC prior to ELISA for the analysis of incurred urine samples showed good efficiency for the elimination of matrix interferences. Owing to the urine-tissue relationship, the urine concentrations can be used to predict the presence of the parent drug in tissues and so possible violations of the maximum residue limit (MRL) can be controlled.  相似文献   

4.
An automated two-dimensional chromatographic method has been developed for the isolation and concentration of recombinant fusion proteins with beta-galactosidase. The system consists of an immunoaffinity column with anti-beta-galactosidase antibodies as ligand, followed by an anion-exchange column. It was used for the purification and concentration of recombinant fusion proteins from Mycobacterium tuberculosis and M. leprae. Small amounts of crude lysates of Escherichia coli were loaded stepwise onto the immunoaffinity column with intermittent washing, elution and re-equilibration. After several cycles the eluate was passed through the anion-exchanger. Using an immunoaffinity gel of 5-ml volume and the anion-exchanger Mono Q HR 5/5, from 10 ml of crude E. coli lysate (containing up to 50 mg of protein) up to 100 micrograms of recombinant protein in a 2-ml volume could be isolated overnight.  相似文献   

5.
Pyraclostrobin belongs to a new generation of fungicides widely used to preserve high valuable crops. In the present study, three monoclonal antibodies with different affinities to this modern strobilurin have been evaluated for their usefulness in the production of immunoaffinity columns suitable for the solid-phase extraction, concentration, and clean-up of residues from food commodities. Different immunosorbents were produced and characterized in terms of antibody immobilization efficiency, immunosorbent binding capacity, optimum elution conditions, and reusability. Covalent coupling of the antibodies to Sepharose-CNBr gel took place with high yield (over 90%), whereas the immunosorbent efficacy to retain the analyte (from 28 to 68%) was shown to depend on the amount and type of antibody immobilized on the support. As a matter of fact, columns prepared with the monoclonal antibody PYs5#14 were able to selectively bound up to 53 μg of pyraclostrobin per gram of beads. Acetonitrile solutions were preferred over methanolic ones for analyte elution, and some immunosorbents could be reused at least 4-6 times provided that the amount of pyraclostrobin and the volume of sample did not overload the column. Effectiveness of the selected immunoaffinity column was evidenced by the development of an extraction procedure for pyraclostrobin residues from fruit juices and further determination by high-performance liquid chromatography with UV detection. A concentration factor of 50 times was achieved with the developed immunoaffinity column, which eventually resulted in a limit of quantification of 0.01 mg L(-1). Finally, quantitative recoveries were obtained on apple juice and red grape must samples spiked with pyraclostrobin from 0.01 to 1 mg L(-1).  相似文献   

6.
A new affinity method for the direct quantitative analysis of monospecific anti-peptide immunoglobulins (antibodies) and, simultaneously, their semi-preparative isolation from blood serum of the immunized animals has been developed. Immunoaffinity discs based on macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) were used as the supporting stationary phase. The specifically prepared synthetic peptides with biological activity imitating that of the immunoglobulin binding sites of various proteins were used as the selective ligands instead of native proteins. These ligands were immobilized by a single-step reaction that involves epoxy groups located on the pore surface of the porous polymer disc with amine groups of the peptide molecules. A spacer between biospecific ligands and the linking site was not required to achieve good separation. These novel immunosorbents characterized by large binding capacity are well suited for high throughput screening. Dissociation constants of the peptide-antibody complexes calculated from the experimental adsorption isotherms confirm the excellent selectivity of the proposed separation method. The discs were used in a single step enrichment of antibodies both from precipitated blood fraction and crude blood serum of immunized animals. The quantitative data of the immunoaffinity disc chromatography were compared to those obtained by an enzyme-linked immunosorbent assay. Gel electrophoresis was also used to demonstrate the high degree of purity of the final product. In contrast to typical techniques that involve proteins, this immunoaffinity approach allows for the first time direct determination of concentration of specific antibodies using the immunosorbent prepared from the short peptide molecules immobilized on the internal surface of reactive porous polymer discs.  相似文献   

7.
In this work, a novel monoclonal antibody specific for naringin was prepared and characterized. Subsequently, an indirect competitive enzyme‐linked immunosorbent assay for naringin was developed, with an effective range from 4.8 to 156 ng/mL naringin. Next, an immunoaffinity column was obtained by coupling anti‐naringin monoclonal antibodies to CNBr‐activated Sepharose 4B and a rapid immunoaffinity chromatography assay for naringin was developed. The immunoaffinity column was used to separate naringin from Citrus aurantium. The results showed that 1 g of the dry Sepharose 4B can couple 10 mg of immunoglobulin G. And the immunoaffinity column can efficiently and specifically capture approximately 250 μg of naringin without cross reacting with its structurally similar compounds. Moreover, our results indicate that the application of immunoaffinity chromatography can simplify the pretreatment and the isolation process greatly compared to conventional methods, providing a potential method for extracting the target component from structurally similar compounds in natural products.  相似文献   

8.
The application of immunoaffinity chromatography for the purification of Taxus plant and cell extracts prior to the HPLC analysis is described. Polyclonal antibodies raised against 10-deacetylbaccatin III (10-DAB III), paclitaxel's main precursor in plant, were characterised by enzymed-linked immunosorbent assay. Immunoglobulins from selected antisera were immobilised on CNBr-activated Sepharose 4B. The immunoaffinity column was used for the purification of plant and plant cell culture extracts prior to their analysis by HPLC. Immunoaffinity chromatography enabled the selective concentration of taxoids and enhanced sample clean-up.  相似文献   

9.
A simple, rapid and specific sample preparation method based on antibody-mediated clean-up for the determination of chloramphenicol (CAP) in milk and eggs was developed. Skimmed milk and centrifuged egg homogenates were filtered and directly applied to immunoaffinity columns which were prepared by coupling monoclonal antibodies against CAP to a carbonyldiimidazole-activated support. Using a 0.2 M glycine, 0.5 M NaCl (pH 2.8) solution as an eluent, the immunoaffinity columns can be used more than 30 times without a decrease in column capacity. In subsequent high-performance liquid chromatographic analysis, no matrix interferences were observed. Good recoveries were obtained at spiking levels of 1-100 micrograms kg-1. Due to the high specificity of the clean-up procedure, the limit of detection can be lowered by increasing the test portion. Concerning milk, the limit of detection was successfully lowered to 20 ng kg-1 by increasing the test portion to 11 (recovery 99%). The method was applied to eggs produced by hens treated with CAP. The results are compared with those obtained by solid-phase extraction using silica gel.  相似文献   

10.
An automated, on-line immunoaffinity extraction method was developed for the analysis of 4 fluoroquinolones in milk: ciprofloxacin, difloxacin, enrofloxacin, and sarafloxacin. This method involves analyte extraction using an immunoaffinity capture column containing anti-fluoroquinolone antibodies coupled on-line with reversed-phase column chromatography. Liquid chromatographic analyses were performed by isocratic elution using a mobile phase of 2% acetic acid-acetonitrile (85 + 15) and an Inertsil phenyl column with fluorescence detection at excitation and emission wavelengths of 278 and 444 nm, respectively. No significant interferences from the sample matrix were observed, indicating good selectivity with the immunoaffinity column. Recoveries from fortified raw milk samples (5-50 ppb of each fluoroquinolone) ranged from 72 to 90%, with standard deviations of < or = 8%.  相似文献   

11.
The paper demonstrates the possibility to use sol-gel-generated immunoaffinity columns as selective sample preparation step in on-line combination with HPLC. In the past sol-gel-generated immunoaffinity columns have only been included in off-line sample preparation schemes. Compared with conventional RP-materials on-line coupling of sol-gel-generated silica matrices with a pore structure designed to retain antibodies poses additional problems caused by their lower pressure tolerance and by the necessity to match the mobile phases not only to take into account the chromatographic properties but also the conformational stability of the antibodies. These problems have been overcome by an on-line system which can be regarded as a prototype for similar systems which exploit the selectivity of sol-gel immunoaffinity columns. The system consists of a sol-gel-generated immunoaffinity column coupled to an RP enrichment column and an analytical column. The practicality of such systems is demonstrated using the example of anti-pyrene immunoaffinity columns applied for the determination of pyrene in aqueous solutions.  相似文献   

12.
《Analytical letters》2012,45(2):243-254
Abstract

An immunoaffinity column (IAC), which can bind diazinon primely, was developed to treat the water and soil samples. The IAC, having an appropriate binding capacity for diazinon (200 ng per mg gel), was prepared by entrapping the anti-diazinon antibody into sol-gel, which was made from hydrolyzed Tetramethoxysilane (TMOS). In comparison with the IACs entrapped with others non-special antibodies, the IAC entrapped with anti-diazinon antibody has a special binding capacity to diazinon. Two different elution modes, 40% and 20% MeCN water solution, were evaluated for desorbing diazinon from the IAC. Efficient desorption of bound diazinon was achieved with the 40% MeCN water elution. The water and soil samples spiked with diazinon were treated by the IAC. The reliable recoveries, which ranged from 50% and 100% with RSD from 4.54% to 16.79%, were achieved.  相似文献   

13.
Hong-Xu Chen 《Talanta》2009,78(2):464-61
Testosterone is one of the most common doping drugs abused by athletes. Therefore, it is necessary to develop a sensitive and simple method to monitor testosterone and its epimer epitestosterone. An off-line immunoaffinity extraction followed by capillary electrophoresis for simultaneous determination of testosterone and epitestosterone has been described in this paper. Anti-epitestosterone monoclonal antibody which is specific to both testosterone and epitestosterone had been prepared and immobilized on a Sepharose 4B stationary phase. The immunoaffinity column was used for sample cleanup, extraction and preconcentration. After elution and reconstitution, testosterone and epitestosterone in the sample were separated and quantified by micellar electrokinetic chromatography(MEKC) using the borate buffer (200 mM borate, pH 8.7) containing 40 mM sodium cholate as a chiral selector. The immunoaffinity column was evaluated in different parameters such as the retention mechanism, selectivity, binding capacity, elution protocol, and reusability. The separation of these two compounds by MEKC was also optimized. Limit of detection for testosterone and epitestosterone were 5 and 23 ng mL−1, respectively. It was satisfactory to apply this method to analyze testosterone and epitestosterone in spiked urine sample with the recoveries from 78% to 109%.  相似文献   

14.
Antibodies are used in many applications, especially as diagnostic and therapeutic agents. Among the various techniques used for the purification of antibodies, immunoaffinity chromatography is by far the most common. For this purpose, oriented immobilization of antibodies is an important step for the efficiency of purification step. In this study, Fc fragment‐imprinted poly(hydroxyethyl methacrylate) cryogel (MIP) was prepared for the oriented immobilization of anti‐hIgG for IgG purification from human plasma. Non‐imprinted poly(hydroxyethyl methacrylate) cryogel (NIP) was also prepared for random immobilization of anti‐hIgG to compare the adsorption capacities of oriented (MIP/anti‐hIgG) and random (NIP/anti‐hIgG) cryogel columns. The amount of immobilized anti‐hIgG was 19.8 mg/g for the NIP column and 23.7 mg/g for the MIP column. Although the amount of immobilized anti‐hIgG was almost the same for the NIP and MIP columns, IgG adsorption capacity was found to be three times higher than the NIP/anti‐hIgG column (29.7 mg/g) for the MIP/anti‐hIgG column (86.9 mg/g). Higher IgG adsorption capacity was observed from human plasma (up to 106.4 mg/g) with the MIP/anti‐hIgG cryogel column. Adsorbed IgG was eluted using 1.0 m NaCl with a purity of 96.7%. The results obtained here are very encouraging and showed the usability of MIP/anti‐hIgG cryogel prepared via imprinting of Fc fragments as an alternative to conventional immunoaffinity techniques for IgG purification. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
A test method is developed for determining benzo[a]pyrene in natural water, based on the use of a polyethylene filter (frit) with adsorbed specific antibodies, placed within a transparent column. In passing a test solution, the analyte is adsorbed on the frit similarly to the process implemented in immunoaffinity preconcentration. The added conjugate of a labeled analyte takes the remained vacant binding sites of antibodies. Luminescent semiconductor nanoparticles (quantum dots) CdSe/ZnS, used as labels, enable visual determination under irradiation with UV light. The limit of detection for benzo[a]pyrene in water is ~0.5 ng/mL.  相似文献   

16.
An immunoaffinity extraction (IAE) column was prepared for extraction of adducts between human serum albumin (HSA) and hexahydrophthalic anhydride (HHPA). HHPA is a strong sensitizer inducing immunoglobulin E antibodies in vivo. Polyclonal antibodies from a rabbit immunized with keyhole limpet hemocyananin-HHPA conjugate were purified using a Protein A Sepharose gel. To obtain antibodies with optimal affinity towards HHPA-protein adducts, HHPA-specific antibodies were selected using an N-hydroxysuccinimide-Sepharose column coupled with albumin-HHPA conjugate. Antibodies eluted from this column at pH 2.2 were selected to prepare the IAE column. The column was evaluated using 2 mL plasma spiked with HSA-HHPA conjugate. The column was eluted with glycine buffer at pH 2.0. The conjugates in the eluate were hydrolyzed to the corresponding HHP acid and quantified by mass spectrometry. The average recovery of HHPA adducts in 11 experiments was 68% with a coefficient of variation (CV) of 7%. The column's capacity to bind protein-HHPA adducts was found to be linear in the range of 0.15-1.2 nmol conjugate. The evaluation showed that the IAE column had adequate affinity towards the HHPA adducts and that the adducts could be extracted with good recovery and precision from a large volume of plasma.  相似文献   

17.
An immunoaffinity matrix was prepared using human polyclonal antibody (Intragam) attached to Sepharose 4B activated with CNBr. The immunoaffinity matrix was then assessed with regard to its capacity to remove viruses. The challenge virus, poliovirus type 1 was loaded in high titre in either PBS or a preparation derived from human plasma known as supernatant II + III. This fraction is depleted of IgG and is used to prepare human albumin. It was shown that an average greater than 5 logs of spiked virus were removed in one passage through the column. This type of approach may prove useful as a viral removal method in biopharmaceutical manufacturing.  相似文献   

18.
An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (<6% of relative standard deviation) at 50 ng/L concentration were also obtained. Due to the ability of the sol-gel immunoaffinity column to eliminate matrix effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.  相似文献   

19.
A simple and accurate method to quantify the mycotoxin deoxynivalenol (DON) in wheat is described. The method uses immunoaffinity chromatography for DON isolation and liquid chromatography (LC) for toxin detection and quantification. Wheat samples are extracted in water, filtered twice and applied to an immunoaffinity column. Following a water wash, DON is eluted from the column with methanol and injected onto an LC system with a UV detector for quantification. Test performance was evaluated in terms of antibody specificity, limit of detection, percentage recovery, precision, column capacity, assay linearity and comparison with the GC-electron-capture detection (ECD) method of Tacke and Casper. Specificity of the immunoaffinity column cleanup procedure was confirmed with only DON (>80%) and its 15-C derivatives (40-50%) being recognized by the antibody while 3-C DON derivatives, nivalenol, T-2 and fusarenon-X did not bind. The limit of detection is at least 0.10 microg/g. Percentage recovery for the entire assay range averages 90% with an average relative standard deviation of 8.3%. Naturally contaminated samples showed comparable precision. Column capacity was determined to be 3.3 microg. The assay showed a high degree of linearity (r2=0.999) and an optimum assay range of 0.10 to 10.0 microg/g. Comparative analysis of 28 naturally or artificially contaminated wheat samples using DONtest-HPLC and the GC-ECD method of Tacke and Casper showed that DONtest-HPLC is a statistically significant predictor of the GC-ECD method (r2=0.982).  相似文献   

20.
An interlaboratory study funded by the European Commission, Standards, Measurement and Testing Programme (4th Framework Programme) was performed to evaluate the effectiveness of an immunoaffinity column cleanup liquid chromatographic (LC) method for the determination of ochratoxin A in baby food at a possible future European regulatory limit (0.1 ng/g). The test portion is extracted in a blender with tert-butyl methyl ether (chosen to avoid use of chloroform but shown to give equivalent extraction efficiency) after addition of 0.5 mol/L phosphoric acid-2 mol/L sodium chloride solution. The extract is centrifuged and redissolved in a mixture of phosphate buffered saline solution and methanol. After removal of lypophilic substances with hexane, the extract is applied to an immunoaffinity column containing antibodies specific to ochratoxin A. The column is washed with water to remove the interfering compounds and the purified ochratoxin A is eluted with methanol. The separation and determination of ochratoxin A is performed by reversed-phase LC and detected by fluorescence after postcolumn derivatization (PCD) with ammonia. Test materials (baby food infant formulae), both spiked and naturally contaminated with ochratoxin A, were sent to 13 laboratories in 8 different European countries. Test portions were spiked at a level of 0.085 ng/g ochratoxin A. The average recovery for the spiked blank baby food was 108%. Based on results for spiked samples (blind pairs at 0.085 ng/g) as well as naturally contaminated samples (blind pairs at levels between 0.05 and 0.22 ng/g) the relative standard deviation for repeatability (RSDr) ranged from 18-36%. The relative standard deviation for reproducibility (RSDR) ranged from 29-63% and HORRAT values of between 0.4 and 0.9 were obtained.  相似文献   