Summary Flexibility, strength and adsorption inertness of fused-silica capillaries permits their extensive application for the preparation of micro-packed columns in gas chromatography. Decreasing the column diameter (from 0.5 to 0.15 mm) and the diameter of the sorbent particles (from 100 to 5 μm) results in a marked reduction of the height equivalent to a theoretical plate (HETP), as well as in diminishing the dependence of the HETP on the carrier gas flow rate. The chromatographic characteristics of fused-silica capillary micro-packed columns and open-tubular columns are compared. The fused-silica capillary micro-packed column can be used to advantage for performing rapid and trace analyses and have been shown to be adapted for application in gas-solid chromatography. Separation of organic and inorganic compounds on fused-silica capillary micro-packed columns is illustrated by practical examples. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

4.
In this work, an investigation of new organosilicon hydride reagents with phenyl functional groups for deactivation and surface modification of fused silica capillary columns is described. Different reagents were tested for their ability to deactivate the fused silica surface, and actual critical surface tension measurements were made using the capillary rise method. The deactivation procedure required lower optimum temperatures than conventional methods. Deactivated capillaries and coated capillary columns were prepared and tested for reproducibility, efficiency, and surface inertness towards basic and acidic compounds at the low nanogram level.  相似文献   

5.
6.
A method is described for surface deactivation and modification of fused silica capillary columns with a cyanopropyl-containing reagent. The deactivation procedure involved a dehydrocondensation reaction between a bis(cyanopropyl)methylhydropolysiloxane reagent and surface silanol groups at an optimum temperature of only 250°C. Actual critical surface tension measurements were made using the capillary rise method. Excellent deactivation for acidic and basic compounds at the low ng level, and wettability for nonpolar and polar polysiloxane stationary phases were obtained. A procedure was developed to remove acidic impurities that are present in polar stationary phases.  相似文献   

7.
8.
The introduction of selected fractions from a liquid chromatograph into a gas chromatograph has been described; however, analyses were performed by off-line experiments requiring collection and reinjection of the separate fractions or by on-line procedures where disadvantageously, only a fraction of the separated peak or a well resolved component in a mixture could be introduced into a gas chromatograph. This disadvantage is overcome by the apparatus and method described in this paper, which utilizes a multidimensional chromatography system employing a high efficiency, packed capillary LC column coupled on-line to a capillary gas chromatograph. The liquid chromatograph (so designed) can act as a highly efficient clean-up or chemical class fractionation step prior to introduction into the gas chromatograph, significantly reducing sample preparation times in many applications. Thus minor components in a complex matrix can be determined without prior sample clean-up, an example of which is the determination of polychlorinated biphenyls in a complex hydrocarbon matrix.  相似文献   

9.
The activity of fused silica capillary tubing has been shown to vary considerably, which severely influences the reproducibility of column deactivation and inertness. Methods for producing a reproducible, high activity surface with maximum hydroxylation by various hydrothermal treatments were evaluated. Columns pretreated with 20% nitric acid at 200°C for 10 hours, deactivated with D4, coated with OV-73, and crosslinked with azo-tert-butane were found to possess excellent inertness for sensitive analytes such as alcohols, amines, and alkaloid drugs.  相似文献   

10.
The life expectancy and resistance to flow, pressure shocks, solvent gradients, and bending of packed fused silica capillary columns (Micro-LC) are discussed.  相似文献   

11.
12.
The effect of deactivating a fused silica surface by silylation with 1,1,3,3-tetraphenyl-1,3-dimethylilazane (TPDMDS), triphenylsilylamine (TPSA), and octamethylcyclotetrasiloxane (D4) and by polydimethylsiloxane degradation (PSD) is studied. Rehydrated, dried, and deactivated Cab-O-Sil M5 samples are used as model materials for 29Si CP-MAS NMR analysis. At about 350 °C, TPDMDS yelds mainly diphenylmethylsiloxysilane, dimethyldisiloxysilane, and triphenylsiloxysilane groups. TPSA yields phenyltrisiloxysilane, diphenyldisiloxysilane, and triphenylsiloxysilane groups. At 400°C, the products formed initially are eventually replaced by methyltrisiloxysilane or phenyltrisiloxysilane groups, while a substantial number of silanol groups still remains. The possible consequences for wettability are discussed. D4 reacts with Cab-O-Sil even at 200°C, but a large number of silanol groups remains. This number decreases gradually at higher temperatures and becomes negligible above 400°C. The formation of methyltrisiloxysilane groups, which starts at 425°C, is predominant at 490°C.  相似文献   

13.
14.
15.
16.
17.
18.
In this study, application of a fused silica capillary column for analysis of toxic anthraquinones and related compounds found in plants was investigated.  相似文献   

19.
A miniaturized continuous gradient elution system was designed for work with packed capillary columns. The retention reproducibility achieved is adequate for many practical applications.  相似文献   