首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(5):767-778
Abstract

A specific and sensitive high‐performance liquid chromatographic method was developed for the determination of metoclopramide in canine plasma. The procedure involves fast liquid–liquid extraction and analysis on an octadecyl silane (ODS) column. A preliminary pharmacokinetic study was performed by applying the developed method to a single oral administration of metoclopramide (MCP) to a dog. The validation method yielded good results regarding linearity, precision, accuracy, and specificity. The procedure is suitable for separation and quantification of MCP in canine plasma, enough to quantify 0.2 ng/ml when 0.5 ml of plasma is used. This assay procedure might be useful for the pharmacokinetic study of MCP in dogs.  相似文献   

2.
An assay for the selective quantification of pseudoephedrine in human plasma and urine was developed using high-performance liquid chromatography with UV detection at 205 nm. Analyte and internal standard were extracted from alkaline plasma or urine into a mixture of n-hexane and diethyl ether, and the organic phase was back-extracted into dilute acid. The chromatographic system comprises microparticulate cyanopropyl-silica as stationary phase and a ternary solvent mixture with ion-pair reagents as mobile phase. Using 0.25 ml plasma, the lower limit of quantification was 25 ng/ml with excellent linearity up to 1000 ng/ml. In urine, the calibration ranged from 2.5 to 100 micrograms/ml. The selectivity of the method was demonstrated for several pharmaceuticals with similar structures. The validated method was applied to a pharmacokinetic study with a single oral dose of 100 mg of pseudoephedrine in two galenic formulations. Precision and accuracy data of the assay and calculated pharmacokinetic parameters are presented.  相似文献   

3.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

4.
A sensitive gas chromatographic method was developed for the determination of Trelibet, 1-benzyl-4-(2'-pyridinecarbonyl)piperazine, and of its major metabolites in biological fluids. The compounds were extracted as bases into dichloromethane, and the extracts were analysed by a dimethylsilicone capillary column with a nitrogen-phosphorus flame-ionization detector. The lower limit of detection was 1 ng/ml for Trelibet and 5 ng/ml for the metabolites. Peak-area ratios of the compounds and internal standard were linearly correlated to their plasma concentrations between 1 and 1000 ng/ml. The method was used for quantification of Trelibet and two of its metabolites in depressed patients after oral administration of a single dose of 200 mg of Trelibet. Concentration data measured in plasma and urine showed that the method is sensitive enough to monitor concentrations both for pharmacokinetic studies and for plasma steady-state levels daily.  相似文献   

5.
A sensitive and specific bioanalytical method for quantitation of a novel antiemetic (ADR-851) in plasma and urine has been developed and validated. The drug and internal standard (metoclopramide) are extracted from the plasma matrix by solid-phase extraction on cyanopropyl bonded-phase columns. After extraction, samples are separated by isocratic reversed-phase high-performance liquid chromatography. The parent drug, internal standard and a yet unidentified metabolite are detected by fluorescence. The method requires 1.0 ml of plasma or 0.1 ml of urine and has a lower limit of quantitation of 2 ng/ml with 10.9% relative standard deviation (R.S.D.). Method linearity has been established over a 2-800 ng/ml range when 1.0 ml of plasma is used. The intra- and inter-day imprecisions for the method are typically better than 6% and 11% R.S.D., respectively, in both plasma and urine over the entire dynamic range. The pooled estimate of bias is less than 5% and attests to the excellent accuracy.  相似文献   

6.
A sensitive hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry method was developed and validated for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine. The method is highly sensitive and specific with good precision and accuracy. In plasma the limit of detection and limit of quantification are 0.03 and 0.1 ng/mL, respectively, for both analytes. In urine the limit of detection and limit of quantification are 0.3 and 1 ng/mL, respectively, for both analytes. The suitability of the method for doping control analysis in equine species is demonstrated by analyzing postadministration samples collected after a single intravenous administration of 50 mg etilefrine to a standardbred mare. Etilefrine was detected up to 120 h in urine and up to 48 h in plasma. Etilefrine is highly conjugated in equine urine whereas it exists in the free form in equine plasma. Therefore, enzyme hydrolysis prior to sample preparation is recommended for the detection and quantification of etilefrine and oxilofrine in equine urine.  相似文献   

7.
A single high-performance liquid chromatographic (HPLC) assay for the quantitative determination of dilevalol, the R,R isomer of labetalol, was developed for both plasma and urine. A significantly improved limit of detection for dilevalol in plasma was accomplished by extensive modification of an HPLC assay originally developed in our laboratory for labetalol. This simplified method is readily adaptable to urine and represents the first reported HPLC assay for the quantitative determination of dilevalol in this biofluid. Drug was recovered from plasma or urine by partition into diethyl ether under mildly alkaline conditions and back-extraction into dilute acid. Reversed-phase separation of dilevalol and the internal standard was accomplished on a 150 X 4.1 mm column commercially packed with a spherical (5 micron) macroporous copolymer (PRP-1). No interferences were observed in extracts obtained from drug-free plasma or urine. Selectivity for dilevalol in the presence of other beta-blockers was established. This method demonstrated a linear detector response to concentrations of unchanged drug typically observed in urine and plasma following once-a-day treatment with dilevalol hydrochloride (100-800 mg). The lowest limit of reliable quantitation was established at 1 ng/ml in plasma. The intra-assay precision (coefficient of variation) remained less than 6% at all concentrations evaluated from 1 to 800 ng/ml. In urine, the lowest limit of quantitation was validated to 20 ng/ml where the intra-assay precision (coefficient of variation) for unchanged drug was less than 4% at all concentrations evaluated up to 400 ng/ml. This method is suitable for routine quantitation of unchanged drug in human plasma and urine following the administration of therapeutically effective doses of dilevalol hydrochloride.  相似文献   

8.
A high-performance liquid chromatographic (HPLC) method with electrochemical detection for the determination of oxilofrine [1-(4-hydroxyphenyl)-2-methylaminopropanol] in human plasma and urine (before and after cleavage of the metabolic conjugates) is described. Isolation from biological fluids is performed batchwise by weak acid cation exchange. Separation of plasma and urine components is achieved on a reversed-phase C18 column as an ion pair with heptanesulphonic acid. For amperometric detection the potential of the electrode was set at 0.95 V versus an Ag/AgCl reference electrode. The detection limit for oxilofrine in plasma is 1 ng/ml and in urine 12.5 ng/ml at a signal-to-noise ratio of 2.0 using 1.0 ml of plasma and 0.02 ml of urine. The method was compared with a gas chromatographic-mass spectrometric method and showed a good concordance for plasma (r = 0.996) and urine (r = 0.994). With the HPLC method it is also possible to determine related sympathomimetic drugs, e.g., etilefrine, norefenefrine or octopamine, after a slight modification of the mobile phase.  相似文献   

9.
A sensitive and simplified high-performance liquid chromatographic procedure has been developed for quantification of amiloride in rabbit plasma, as well as human plasma and urine. Following protein precipitation with perchloric acid, the supernatant was directly injected into a C18 Nucleosil column. The mobile phase consisted of methanol-water (45:55) containing 0.1 M perchloric acid, and the compound was quantitated using a fluorescence detector at excitation and emission wavelengths of 286 and 418 nm, respectively. The average recovery was 97.6%. The calibration curve was linear over the range 2.0-20.0 ng/ml. The limit of detection was 0.5 ng/ml.  相似文献   

10.
Alentamol hydrobromide, (+)-2-(dipropylamino)-2,3-dihydro-1H-phenalen-5-ol monohydrobromide, is a selective dopamine agonist currently being investigated for the treatment of schizophrenia. This paper describes a reversed-phase high-performance liquid chromatographic-based method for the quantification of alentamol in blood plasma and urine. The method utilizes solid-phase extraction with carboxylic acid-derivatized silica columns. A limit of quantitation of 0.1 ng/ml in plasma was achieved by virtue of selective extraction and fluorescence detection. Example chromatograms of plasma and urine specimens from clinical trials demonstrate the utility of the method.  相似文献   

11.
Abstract

Metoclopramide concentrations in plasma and urine were determined by high performance liquid chromatography using a cyanopropylsilane column and UV detection. The mobile phase consisted of 0.03M sodium acetate (pH 7.4) and acetonitrile. The plasma samples were extracted with dichloromethane after pH adjustment. Urine proteins were precipitated with acetonitrile. The reproducibility and precision of the methods were demonstrated by the analysis of samples containing 5 – 200 ng/ml plasma and 0.25 – 200 ug/ml urine.

The glucuronide and sulfate conjugates of metoclopramide were also quantitated after differential acid hydrolysis of urine samples. The conditions for acid hydrolysis were studied. The methods have been applied to the analysis of plasma and urine samples obtained from human volunteers.  相似文献   

12.
A high-performance liquid chromatographic method for the measurement of bumetanide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol-water-glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5-2000 ng/ml.  相似文献   

13.
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.  相似文献   

14.
A rapid, specific and direct method based on capillary column gas chromatography with electron-capture detection is described for the simultaneous determination of nicardipine, a new calcium antagonist, and its pyridine metabolite II in human plasma. In this method, the nicardipine, its pyridine metabolite II and internal standard are extracted from the plasma and then partially purified by acid-base partitioning prior to the final injection onto the capillary column gas chromatograph for quantification by means of an electron-capture detector. The quantification limit of the method is 1 ng/ml of plasma for both nicardipine and its pyridine metabolite II. The coefficients of variation for nicardipine and the pyridine metabolite II at concentrations of 1-50 ng/ml are less than 7% and less than 9% (n = 4), respectively. The method has been validated against a previously developed high-performance liquid chromatographic method (sensitivity 5 ng/ml).  相似文献   

15.
A novel pre-column derivatization reversed-phase high-performance liquid chromatography with fluorescence detection is described for the determination of bupropion in pharmaceutical preparation, human plasma and human urine using mexiletine as internal standard. The proposed method is based on the reaction of 4-chloro-7-nitrobenzofurazan (NBD-Cl) with bupropion to produce a fluorescent derivative. The derivative formed is monitored on a C18 (150 mm × 4.6 mm i.d., 5 μm) column using a mobile phase consisting of methanol-water 75:25 (v/v), at a flow-rate of 1.2 mL/min and detected fluorimetrically at λ(ex) = 458 and λ(em) = 533 nm. The assay was linear over the concentration ranges of 5-500 and 10-500 ng/mL for plasma and urine, respectively. The limits of detection and quantification were calculated to be 0.24 and 0.72 ng/mL for plasma and urine, respectively (inter-day results). The recoveries obtained for plasma and urine were 97.12% ± 0.45 and 96.00% ± 0.45, respectively. The method presents good performance in terms of precision, accuracy, specificity, linearity, detection and quantification limits and robustness. The proposed method is applied to determine bupropion in commercially available tablets. The results were compared with an ultraviolet spectrophotometry method using t- and F-tests.  相似文献   

16.
The dioxopiperazine metabolites of quinapril in plasma and urine were extracted with hexane-dichloroethane (1:1) under acidic conditions. Following derivatization with pentafluorobenzyl bromide and purification of the desired reaction products using a column packed with silica gel, the metabolites were analysed separately by capillary column gas chromatography-electron-impact mass spectrometry with selected-ion monitoring. The limits of quantitation for the metabolites were 0.2 ng/ml in plasma and 1 ng/ml in urine. The limits of detection were 0.1 ng/ml in plasma and 0.5 ng/ml in urine, at a single-to-noise ratio of greater than 3 and greater than 5, respectively. The proposed method is applicable to pharmacokinetic studies.  相似文献   

17.
A high-performance liquid chromatographic method with ultraviolet detection at 210 nm for quantitation of bupivacaine and two of its metabolites from plasma and urine is described. The compounds are extracted into n-hexane-isopropanol (5:1), evaporated and the reconstituted residue injected onto a reversed phase C18 column. Standard curves for all compounds were linear (r2 greater than 0.999) in the range 20-2000 ng/ml, with a limit of detection of 10 ng/ml. The inter-day coefficients of variation ranged between 2.7 and 12.2%. The method was applied to analyse bupivacaine and metabolite concentrations in patients on long-term epidural bupivacaine-fentanyl infusions.  相似文献   

18.
Determination of malotilate and its metabolites in plasma and urine   总被引:1,自引:0,他引:1  
A method for the determination of malotilate (I), the corresponding monocarboxylic acid (II) and its decarboxylated product (III) in plasma is described. Plasma was extracted with chloroform spiked with internal standard. The residue, dissolved in methanol, was chromatographed on a reversed-phase column with a mobile phase of 60% acetonitrile and 1% acetic acid in water. The sensitivity limit for I, II and III was 50, 25 and 100 ng/ml of plasma, respectively. Compound I in the same plasma extract was also analysed by gas chromatography--electron-impact mass spectrometry. The base peaks m/z 160 for I and m/z 162 for internal standard (IV) were monitored; the sensitivity limit for I was 2.5 ng/ml of plasma. The determination of the metabolites of I, II and its conjugate (V), and isopropyl-hydrogen malonate (VI) in urine by high-performance liquid chromatography is also described. The limit of quantification for VI was 2.0 micrograms/ml, and the overall coefficient of variation of VI was 4.7%. The limit of quantification for II in urine was 0.5 micrograms/ml and that for V was 1.0 micrograms/ml as total II (II + V). The overall precision of the method was satisfactory. The method was used to determine plasma and urine concentrations in four dogs orally dosed with 100, 200 or 400 mg of malotilate.  相似文献   

19.
An improved method for the determination of 4-amino-1-hydroxybutane-1,1-bisphosphonic acid (alendronate) in human urine and an assay in human plasma are described. The methods are based on co-precipitation of the bisphosphonate with calcium phosphates, automated pre-column derivatization of the primary amino group of the bisphosphonic acid with 2,3-naphthalene dicarboxyaldehyde (NDA)-N-acetyl-D-penicillamine (NAP) or cyanide (CN-) reagents, and high-performance liquid chromatography (HPLC) with electrochemical (ED) or fluorescence detection (FD). The feasibility of ED of the NDA-CN- derivative of aldendronate has been demonstrated, and a HPLC-ED assay in human urine has been validated in the concentration range 2.5-50.0 ng/ml. In order to eliminate the cyanide ion from the assay procedure, several other nucleophiles in the NDA derivatization reaction were evaluated. An NDA-NAP reagent was found to produce highly fluorescent derivatives of alendronate. The assay in urine based on NDA-NAP derivatization and HPLC-FD has been developed and fully validated in the concentration range 1-25 ng/ml. Based on the same NDA-NAP derivatization, an assay in human plasma with a limit of quantification of 5 ng/ml has also been developed. Both HPLC-FD assays were utilized to support various human pharmacokinetic studies with alendronate.  相似文献   

20.
A rapid and sensitive method for the screening and quantification of 35 benzodiazepines in human urine by gas chromatography/time-of-flight mass spectrometry was developed and validated. Target analytes were isolated from 1 ml urine by solid-phase extraction using Oasis MCX extraction columns (extraction recovery between 35 and 99%). With a supported liquid-liquid extraction method, a new modification of conventional liquid-liquid-extraction, a less time intensive alternative for benzodiazepine extraction is presented. The sample pretreatment entails the derivatization of the benzodiazepines with N,O-bis(trimethylsilyl)trifluoroacetamide plus 1% trimethylchlorosilane. Separation of all benzodiazepines was done within 9.5 min, and detection was based on full mass spectra for each analyte. A deconvolution algorithm was used for unresolved chromatographic peaks to identify coeluted substances. The subsequent quantification was done using significant masses. The limit of quantification is 10 ng/ml for most of the compounds. Linearity is in the range between 10 and 350 ng/ml. Reproducibility was observed with coefficients of variation below 2% at concentrations of 50 and 200 ng/ml. The accuracy is between 88 and 108% depending on the respective analyte and the concentration.  相似文献   