首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this paper, cellular automata are used to detect the nuclear tracks in the track images captured from the surface of CR-39 detectors. Parameters of the automaton as the states, neighborhood, rules and quality parameters are defined optimally for the track image data set under analysis. The presented method is a supervised computational algorithm which comprises a rule definition phase as the learning procedure. Parameter optimization is also performed to adapt the algorithm to the data set used.  相似文献   

2.
The effect of additives and cure cyle parameters on pre and post irradiation annealing characteristics of CR-39 detectors has been investigated. Effect of pre and post irradiation annealing on bulk etch rate, sensitivity, track diameter and etching behaviour of various CR-39 detectors has been investigated.  相似文献   

3.
Solid-state nuclear track detectors (SSNTDs) have found wide use in various domains of science and technology, e.g. in environmental experiments. Measurement of α activity on sources in an environment, such as air, is not easy because of the short penetration range of the α particles. Furthermore, the measurement of α activity by most gas ionization detectors suffers from the high background induced by the accompanying gamma radiation. SSNTDs have been used successfully as detecting devices as passive system to detect the α contamination of different surfaces. This work presents the response of CR-39 (for two types) to α particles from two sources, 238Pu with energy 5 MeV and 241Am with energy 5.4 MeV. The methods of etching and counting are investigated, along with the achievable linearity, efficiency and reproducibility. The sensitivity to low activity and energy resolution are studied.  相似文献   

4.
The bulk etch rate for two types of CR-39 detector was measured as a function of temperature and the activation energies of bulk etching was determined. Experimental values of track etch rate were derived directly from the function of the succesive measured track length vrs. etching time for 209Bi, 129Xe and 20Ne ions.

The maximum etchable length of 13 MeV/u 209Bi and 13.04 MeV/u 129Xe ions have been measured at and below these energies. A comparison of the measured and calculated track length data is presented.  相似文献   


5.
《Radiation measurements》1999,31(1-6):141-144
The possibility of using CR-39 to measure the depth profile of 10B in Si is analysed. The measuring technique exploits the 10B(n, )7Li nuclear reaction. For this reason the track parameters (size, optical properties) of low energy alpha-particles (<1.47 MeV) were studied. The results showed that an energy resolution of about 100 keV could be obtained by an appropriate selection of etching conditions. The profile of 10B in Si at a depth as small as 1 μm can be measured.  相似文献   

6.
As a frame work of the study for the latent track size measurement using atomic force microscope, we have measured the minute etch pits and the extremely small amount of bulk etch of CR-39 at the beginning of chemical etching, and obtained its growth curves in nanometer dimensions. The pieces of CR-39 were exposed to 6 MeV/nC and Fe ions with normal incidence angle and were etched in 70°C 7 N NaOH solution for 0.5,1,2,3,5 min. The diameters of latent track were estimated to be 17 nm for Fe ions and 8 nm for C ions, respectively. These values are comparable to the experimental data on the average ‘track core diameters’ that have been obtained by various experimental techniques.  相似文献   

7.
At the beginning of the etching process a constant track etch rate can be assumed. In deeper detector layers, however, the etch rate varies drastically along the particle trajectories. Consequently, the indirect determination of the track etch rate by measuring the etch pit diameters on the detector surface does not yield correct results. Therefore, a method for the direct measurement of the track etch rate as a function of the depth within the detector was developed. Applying this method, the relationship between the track etch rate and the energy loss in CR-39/PATRAS could be derived.  相似文献   

8.
The effect of post-irradiation treatment of CR-39 track detector in carbon dioxide atmosphere on the alpha particle registration sensitivity was investigated. Significant increase in etch rate ratio for 6.1 MeV 252Cf alpha particle was observed. The sensitization increasedboth as a function of trating time and as a function of carbon dioxide pressure in the treating vessel. Energy dependence of the sensitization was found to be small in the 2–9 MeV alpha particle energy interval. Fading of latent tracks after the sensitization process was slow in a one day period. Pre-irradiation treatment in carbon dioxide showed also some sensitization, though to a lesser extent than post-irradiation treatment. However, exposing CR-39 alpha particles in pure carbon dioxide atmosphere resulted in dramatic decrease in sensitivity. The role of dissolved oxygen and carbon dioxide in the primary latent track formation and in post-irradiation latent track transformation is discussed. Potential influence of the application of sensitization of CR-39 in radon, neutron and cosmic ray charged particle dosimetry is also discussed.  相似文献   

9.
In this work, new empirical equation describing the charged particles radiation track development against etching time and track longitudinal depth are presented. The equation involves four free fitting parameters. It is shown that this equation can reproduce tracks depth formed on the CR-39 by alpha particles at different energies and etching times. Parameters values obtained from experimental data can be used to predict etched track lengths at different energies and etching times. The empirical equation suggested is self consistent as far as reproducing all features of track depth development as a function of etching time and energy are concerned.  相似文献   

10.
In this paper, the previous modeling of protons and alpha particles tracks depth in CR-39 nuclear track detectors was extensively extended to describe tracks of heavier ions. These ions include deuteron, lithium, boron, carbon, nitrogen and oxygen. Based on a compilation of published experimental results related to these ions, a set of empirical fitted model parameters is obtained for each type of ion. The A dependence of these model parameters is obtained.  相似文献   

11.
The neutron response of electrochemically etched (ECE) CR-39 detectors is determined by the energy and angular dependence of the response to neutron-induced charged particles. This response has been measured for the example of protons with various initial energies and angles of incidence. Besides, some studies were made for modeling the mechanism of ECE of the proton trajectories with the aim of deriving the critical angle of incidence.  相似文献   

12.
用20—1020 keV单能质子刻度CR-39固体核径迹探测器   总被引:1,自引:0,他引:1       下载免费PDF全文
用北京师范大学2×1.7MV串列加速器和400 kV高压倍加器产生的20—1020 keV单能质子束对CR-39固体核径迹探测器进行了刻度.为了保证质子的单能性和固体核径迹探测器上径迹密度不能超过106/cm2的要求,对两台加速器分别采用了不同方法控制质子辐照数量.在串列加速器上采用了狭缝加转盘的方法,在高压倍加器上采用了100 ns单次高压脉冲扫描束流的方法,既保持了质子的单色性,又达到了质子注量小于106/cm2关键词: 单能质子 固体核径迹探测器 CR-39  相似文献   

13.
Samples of CR-39, PM-355, and PM-500 plastic detectors were irradiated with carbon ions of energy ranging from 0.9 MeV to 14.7 MeV. After the irradiation the detector samples were etched for a period from 2 hrs to 10 hrs. Dependence of track diameters on the ion energy values for different etching times, and dependence of VT/VB as a function of incident carbon-ion energy, are presented.  相似文献   

14.
A miniature diffusion chamber with a 25 × 4 × 0.5 mm CR-39 track etch detector (Pershore Moulding Ltd.), mounted on the 1.1 m long pole has been developed for radon gas measurements at 1 meter depth in the soil. For chemically etched CR-39 (7h, 70°C NaOH) and automatic track analysis the lowest detection limit of the chamber was found to be 0.5 MBq h m−3 and the useful exposure range from 2 to 20 MBq h m−3. The typical exposure time in the soil is between 2 to 14 days. The chamber was tested against the active AlphaGUARD PQ-2000 (Genitron Instruments GmbH) probe. The test yielded consistent results for soils with typical values of permeability and which are not miniature with water. The pilot measurements of radon gas in soil conducted with the miniature diffusion chambers around 48 buildings in Kraków and Silesia regions yielded an average radon concentration of 13 kBq m−3. The chambers are to be applied to measure radon concentration in soil before constructing new houses in order to avoid high radon risk areas.  相似文献   

15.
Solid State Nuclear Track Detectors (SSNTDs) have been used for corpuscular diagnostic in numerous high-temperature plasma experiments. This paper presents different applications of the detectors mentioned above, particularly in nuclear fusion investigations. Some new projects and proposals of the use of such detectors in large-scale plasma experiments, e.g. tokamaks, and laser-fusion facilities are demonstrated. To use the SSNTDs in the optimal way and to determine their detection characteristics, detailed calibration studies of the selected plastic detectors (CR-39, PM-355, PM-500, PM-600) have been performed at IPJ for several years. To carry out calibration measurements of these detectors, ion beams from different accelerators were applied. The paper presents detection characteristics, i.e. track dimensions as a function of ion energy, atomic number and etching time.  相似文献   

16.
Two techniques have been developed to investigate the characteristic of the sensitivity of CR-39 (polyallyldiglycol carbonate) track detector using Am---Be neutron source. The firstis to measure volume track density created by fast neutrons in CR-39 detectors. The second is to measure areal asymptotic track density on the surface of CR-39 sheets. Two types of CR-39—SY-2 CR-39 made in China and another made in USA were calibrated using the techniques. It shows that the two types of CR-39 detectors have nearly the same sensitivity to detect fast neutrons. The techniques developed in this work can be applied to calibration of other track detectors.  相似文献   

17.
A device to determine the detection efficiency of CR-39 for alpha particles is presented. A beehive collimator restricted the angle of incidence of alpha particles on a CR-39 sheet, such that the total number of alpha emitters could be determined. This makes it possible to obtain the critical angle of incidence, ΘC, and the maximum angle of incidence resulting in round (diameter ratio <1.100) etch pits, Θmax. In this work, these angles were determined for incidence energies around 7.5 MeV (more specifically 6.1 and 8.8 MeV).  相似文献   

18.
The CR-39 detectors are widely used as passive radon dosimeters, as well as in physics laboratories or for industrial applications. For what concerns radon monitoring, the calibration curve which is usually adopted corresponds to a linear relation between the actual etched track density and the track density counted by an automatic acquisition system. This linear calibration provides very accurate radon exposure assessments in a restricted range of etched track density, however it neglects the effect of the tracks overlapping that becomes as relevant as the track density increases. In the present work the mathematical expression of the area covered by a set of uniformly distributed tracks is deduced. This result allows then to infer the probability that the system acquires the right track density, providing a general calibration curve for a solid state radon track detector. The process of track production and reading routine is also simulated adopting a Monte Carlo approach, showing that the obtained results are in agreement with the function proposed as calibration curve. Moreover, a linear dependence between the track average area and the rate parameter of the calibration curve has been observed. Finally a semi-empirical correlation based on the previous results is proposed.  相似文献   

19.
Recently, space radiation dosimetry measurements were made by passive and active detectors inside the Spacelab [STS-47 (FMPT): 300km, 57°, STS-65 (IML-2 mission): 300km, 28.5°]. The LET distributions obtained by antioxidant doped CR-39 inside the Spacelab were compared with those measured by the tissue equivalent proportional counter (TEPC) and the real time radiation monitoring device (RRMD) consisting of eight silicon detectors. While both distributions by CR-39 are in good agreement with those obtained by active detectors over the region of LET of several tens to 200 keV/μm, a significant difference in the LET region of smaller than several tens keV/μm is seen. It is considered to be caused by the dip angle dependence of track formation sensitivity in CR-39. The track formation sensitivity for different dip angle were measured for several high heavy energy ions. Using these results, the correction for the dip angle was made for the LET distribution. The corrected result is consistent with the results obtained by active detectors.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号