Capillary electrophoresis-electrospray ionization-mass spectrometry has the potential to become a preferred tool for the analysis of biological mixtures and other complex samples. The development of improved interfaces in the past twenty years has been critical in demonstrating the feasibility of this technique. However, a compromise still exists between interfaces that give optimal performance and those that are practical for commercial applications. The first section of this review focuses on the technological advances in CE-ESI-MS as they relate to the key interface features for both sheath-flow and sheathless systems: delivery of the sheath liquid, shaping of the emitter tip, formation of electrical contact, and practicality in terms of ease of use and lifetime. In the second section, we review the fundamental processes that affect interface performance. Because of the complex natures of both capillary electrophoresis and electrospray ionization, flow rate, arrangement of the electrical circuit, electrochemistry, tip geometry and location of electrical contact must all be carefully managed in the design of a successful interface.  相似文献   

2.
The combination of capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) via a triaxial interface was studied as a potential means for the characterization of intact proteins. To evaluate the possibility to use a nonvolatile electrolyte for CE, the effect of sodium phosphate and ammonium borate on the MS signal of the proteins insulin, myoglobin, and bovine serum albumin (BSA) was investigated by employing infusion experiments, and compared to the effect of ammonium formate and formic acid. The study shows that with formic acid (50 mM, pH 2.4) the most intense protein signals were obtained, while the use of sodium phosphate buffer (5 and 10 mM, pH 7.5) almost completely diminished the MS response. Ammonium formate and ammonium borate (up to 100 mM, pH 8.5) also caused protein ion suppression, but especially with the borate buffer significant MS intensity remained. MS analysis of myoglobin revealed the loss of the heme group when an acidic CE electrolyte was used. Using a background electrolyte containing 25 mM ammonium borate (pH 8.5), it is demonstrated that a CE separation of a protein test mixture can be monitored with ESI-MS without degrading the MS performance allowing molecular weight determinations of the separated compounds. In the presence of borate, detection limits were estimated to be 5-10 microM (ca. 100 fmol injected). The usefulness of the CE-MS system employing a borate buffer is indicated by the analysis of a stored sample of BSA revealing several degradation products. A sample of placental alkaline phosphatase (PLAP), a potential therapeutic agent, was also analyzed by CE-MS indicating the presence of a protein impurity. Probably due to insufficient ionization of the PLAP (a complex glycoprotein), no MS signals of the intact protein were observed.  相似文献   

3.
In this work, a new capillary electrophoresis-mass spectrometry (CE-MS) procedure is developed to analyze proteins in Spirulina platensis microalgae. It is demonstrated that a fine optimization of several separation parameters is essential in order to achieve suitable CE-MS analysis of these proteins in natural extracts from microalgae. Namely, optimization of the composition of the separation buffer, electrospray conditions, and washing routine between runs are required in order to obtain reliable and reproducible CE-MS analyses of the main proteins found in this microalga (namely, allophycocyanin-alpha chain, allophycocyanin-beta, c-phycocyanin-alpha, and c-phycocyanin-beta). The relative molecular mass of these biopolymers is determined using two different MS instruments coupled to CE, i.e., CE-ion trap-MS and CE-time of flight-MS (CE-TOF-MS). A comparison between the results obtained with both instruments is carried out. The high resolution of the TOF-MS enables the distinction of small modifications in proteins and, thus, a more accurate mass determination. Interestingly, molecular mass values obtained by both CE-MS procedures agree very well while these experimental values are only in partial agreement with those theoretically expected (i.e., genetically derived masses). Some protein modifications due to amino acids exchange induced by nucleotide codon mutations are proposed to explain this difference.  相似文献   

4.
A sturdy home-built sheathless CE/ESI-QTOF-MS system was developed and optimized for carbohydrate analysis. The interface and employed methodology provided a simple analytical solution to laborious CE/MS interfacing methods and to problems in characterization of complex carbohydrate mixtures that require high-resolution separation of the components. The CE/ESI interface, feasible in any MS laboratory, consists of a one-piece CE column having the CE terminus in-laboratory shaped as a microsprayer and coated with copper. The CE microsprayer was inserted into an in-house made stainless steel clenching device and the whole assembly was mounted onto a quadrupole TOF mass spectrometer. The analytical potential of the interface in terms of suitability, microsprayer performance, copper coat durability, ionization efficiency, spray stability, and sensitivity was tested first on a simple mixture of standard saccharides, which were separated, resolved, and detected with high separation efficiency. The approach was next assessed for the screening of a biological sample, a complex mixture of O-glycosylated sialylated amino acids from urine of a patient suffering from Schindler disease. Preliminary data allow this method to be considered as one of general applicability in structural glycobiology and glycomics and easy to be implemented for proteomic surveys as well.  相似文献   

5.
After a presence of highly hepatotoxic and potentially carcinogenic N-nitrosodimethylamine was detected in certain lots of sartan, ranitidine, metformin, and other pharmaceuticals, local regulatory authorities issued recalls of suspected products, and concerns of the pharmacotherapy safety were widely discussed. Since then, testing of a representative sample of each produced lot of these pharmaceuticals is required as a part of quality control processes. Hence, an interface-free CE-nanoESI system coupled with MS detection was employed for the development of a simple and economical method for quantitative detection of this contaminant in the valsartan drug substances and finished formulations used as model matrices. In this arrangement, a fused-silica capillary was used as both a separation column and a nanoESI emitter providing high ionization efficiency and sensitivity. The optimized procedure was found to have sufficient selectivity, linearity, accuracy, and precision. The established LOD and LOQ values were 0.3 and 1.0 ng/mL, respectively. The practical applicability of the method was tested by analyses of commercially available Valsacor® tablets. The results obtained prove that the developed procedure represents a promising alternative to currently available GC- and LC-based methods. Furthermore, after an adjustment of the separation conditions, the CE-nanoESI/MS system can be conceptually used for the determination of NDMA in other suspected pharmaceuticals.  相似文献   

6.
We describe an analytical method involving solid-phase extraction (SPE) and capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) for determining some pharmaceutical compounds - naproxen, clofibric acid and bezafibrate - in real water samples. The electrospray parameters were optimized to maximize sensitivity. When a mixed aqueous-organic solvent and CZE-ESI-MS were used to analyze these drugs in water samples, the capillary was coated with hexadimethrin bromide (HDB) to permanently reverse the EOF. The method was developed from off-line SPE-CZE-MS and was validated with surface water. The detection limits were 100 ng.L(-1) for all analytes. The method was applied to analyze water samples from the influent and effluent of a sewage treatment plant. A liquid-liquid extraction step was required before SPE, and the compounds studied were found, some of them between detection and quantification limits.  相似文献   

7.
CZE-ESI-MS联用测定小肽混合物的研究   总被引:3,自引:0,他引:3  
研究肽的分离行为、测定方法及测定条件对蛋白质组学研究具有重要意义 .毛细管电泳 ( CE)作为一种高效、快速的分离方法 ,样品用量少 ,已被广泛应用于生物领域中 ,尤其是小肽和蛋白质的分离分析 .质谱 ( MS)能够进行微量鉴定 ,并提供精确的分子量和结构信息 ,使其成为小肽和蛋白质检测和序列测定的强有力的支撑技术之一 [1~ 3] .其中 ,电喷雾 ( ESI)质谱作为一种软电离技术 ,易与常规的高分辨率分离方法如高效液相色谱、毛细管电泳等实现在线联用 ,具有分离效率高、检测灵敏度高和样品定性方便等特点 ,因而在小肽和蛋白质的测定中得到广…  相似文献   

8.
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two‐dimensional separation. To improve the performance of hyphenated CE‐IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 μL/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5–250 μg/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 μg/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE‐ESI‐IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra‐violet transparent compounds or none fluorescent compounds.  相似文献   

9.
In this work, the usefulness of CE-MS to monitor and optimize the pressurized liquid extraction (PLE) of proteins from Spirulina platensis microalga is demonstrated. Crude and purified PLE extracts from microalga were analyzed by CE-MS. It was observed that the use of purification protocols of phycobiliproteins (namely, ultrafiltration or precipitation-dialysis-freeze drying) resulted in better CE resolution and MS signals, demonstrating that sample matrix plays an important role in CE-MS of proteins in real samples. Ultrafiltration was found less laborious and much faster than precipitation-dialysis-freeze drying (1 vs. 48 h). Direct analysis of crude extracts was demonstrated to be also possible by CE-MS, providing less-quality information but enough to characterize PLE extracts in a much faster way. Therefore, the latter protocol was selected to monitor and optimize the extraction process of phycobiliproteins from S. platensis. To do that, different extraction conditions were tested, including time, temperature and pressure of extraction, nature of pressurized liquid, distribution of microalga inside the extraction cell, type of packing, etc. It is demonstrated that the combined use of PLE and CE-MS allows the attainment of extracts rich in phycobiliproteins in short extraction times (namely, yields of 20% can be obtained in less than 2 h under the optimum PLE process in an automatic way). To our knowledge, this work shows for the first time the usefulness of CE-MS for monitoring and optimizing a PLE process.  相似文献   

10.
《Electrophoresis》2018,39(11):1382-1389
A sheath‐flow interface is the most common ionization technique in CE‐ESI‐MS. However, this interface dilutes the analytes with the sheath liquid and decreases the sensitivity. In this study, we developed a sheathless CE‐MS interface to improve sensitivity. The interface was fabricated by making a small crack approximately 2 cm from the end of a capillary column fixed on a plastic plate, and then covering the crack with a dialysis membrane to prevent metabolite loss during separation. A voltage for CE separation was applied between the capillary inlet and the buffer reservoir. Under optimum conditions, 52 cationic metabolite standards were separated and selectively detected using MS. With a pressure injection of 5 kPa for 15 s (ca. 1.4 nL), the detection limits for the tested compounds were between 0.06 and 1.7 μmol/L (S/N = 3). The method was applied to analysis of cationic metabolites extracted from a small number (12 000) of cancer cells, and the number of peaks detected was about 2.5 times higher than when using conventional sheath‐flow CE‐MS. Because the interface is easy to construct, it is cost‐effective and can be adapted to any commercially available capillaries. This method is a powerful new tool for highly sensitive CE‐MS‐based metabolomic analysis.  相似文献   

11.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.  相似文献   

12.
张含智  李凤  康经武 《色谱》2023,41(2):160-167
毛细管电泳-质谱联用技术具有分离效率高、检测灵敏度高、样品消耗量少,可同时提供样品的结构信息等优点,成为复杂样品分离分析的强有力工具。但是,毛细管电泳与质谱联用的接口技术依然未能很好的解决。为了拓展我们发展的金箔包裹的毛细管电泳分离柱尖端直接作为喷雾电极和无鞘流质谱接口的应用,本文报道了用无鞘流接口毛细管电泳-电喷雾质谱联用(CE-ESI-MS)分析5种酪氨酸激酶抑制剂(舒尼替尼、甲磺酸伊马替尼、吉非替尼、达沙替尼、埃罗替尼)的研究结果。这种接口集分离与电喷雾离子化于一根毛细管中,制作简单,成本低廉,且可批量制作。实验发现采用非水毛细管电泳分离模式不仅可以对5种酪氨酸激酶抑制剂实现基线分离,而且可以获得稳定的质谱信号。考察了电解质溶液组成对分离效果的影响,得到优化的背景电解质组成,即含2%(v/v)乙酸及5 mmol/L乙酸铵的乙腈-甲醇(80∶20, v/v)混合溶剂。在优化的条件下,5种激酶抑制剂可以得到基线分离,无鞘接口也可以长时间保持稳定的电喷雾,分析物的保留时间日内、日间重复性(RSD值)分别小于0.5%和0.8%,接口批次间的RSD值小于2.6%。与水相分离条件下的CE-MS对比,非水相条件下的5种酪氨酸激酶抑制剂的分离柱效更高,检测灵敏度更高,绝对检出限达到amol级。此外,采用无鞘流CE-MS分析了各类有机酸(千层纸素A、丹酚酸C和迷迭香酸)和脂溶性的大环内酯类抗生素(阿奇霉素、红霉素和环孢素A),均可以获得良好的分离效果和质谱检测结果。  相似文献   

13.
A simple and cost-effective capillary electrophoresis/mass spectrometric (CE/MS) method for the analysis of small carboxylic acids including succinate, malate, tartarate, maleinate and citrate, is described. All CE/MS experiments were performed with uncoated fused-silica capillaries and with alkaline volatile buffer solution (ammonium formate buffer, pH 10). Since sheath liquids have significant effects on the sensitivity in typical CE/MS applications, the effects of type and flow rate of the sheath liquids on the sensitivity of carboxylic acids were investigated. As the result, the best sensitivity was obtained with the alkaline sheath liquid (5 mM ammonium hydroxide in water/methanol (50/50, v/v) solution) at 6 μl min−1. With the alkaline volatile buffer solution, sufficient electroosmotic flow (EOF) to carry all small carboxylic acids toward the cathode (MS side) was obtained, although all analytes had different electrophoretic mobilities toward the anode (the CE inlet). Taking advantage of the relatively higher EOF velocity, several carboxylic acids could be detected by MS in ESI-negative mode with a short analysis time. The R.S.D. values (n=5) for the migration time and the peak area of the carboxylic acids tested were less than 0.6 and 4.2%, respectively. The method was applied to the CE/MS analysis of carboxylic acids in apple juice to demonstrate the applicability to real samples.  相似文献   

14.
The microheterogeneous peptaibol alamethicin F30 isolated from the culture broth of Trichoderma viride was analyzed by nonaqueous CE-electrospray-MS using an IT and a TOF mass analyzer. Compared to aqueous buffers, higher separation selectivity was observed for methanolic BGE allowing the detection of more minor components. The low electrophoretic mobility observed for neutral analytes under nonaqueous conditions may be explained by ion-dipole interactions between the peptide analytes and electrolyte ions. The amino acid sequences of the individual components were derived from MS(n) using the doubly or triply charged pseudomolecular ions as well as characteristic fragments as precursor ions. The exchange of Ala by alpha-aminoisobutyric acid (Aib) which is frequently observed for peptaibols was detected for several components. Additional variations included the exchange of Gln to Glu, and the loss of the C-terminal amino alcohol or of the first six amino acids from the N-terminus with concomitant formation of pyroglutamyl residues. In most cases comigration of the Aib peptaibols with the respective Ala component was observed as the mass difference of 14 Da as the result of the amino acid exchange was not sufficient to translate into an electrophoretic separation under the conditions applied. However, proper selection of the precursor ions allowed the unequivocal analysis of the components. Additional TOF-MS measurements were performed in order to resolve the ammonium adducts from comigrating compounds (i.e., Aib-Ala exchange) and to confirm the amino acid composition of the individual components. Except for neutral compounds migrating close to the EOF the mass accuracy was better than 4 ppm for the doubly charged pseudomolecular ions and better than 2 ppm for triply charged ions.  相似文献   

15.
A general equation established in a previous study was used to model the electrophoretic mobility of a series of opioid peptides as a function of pH of the separation electrolyte. The concordance between the predicted and the experimental electrophoretic mobilities was excellent and the optimum pH for the separation of the modelled compounds could be predicted from a limited amount of experimental data. The equations were also useful for the accurate determination of the ionization constants of the polyprotic analytes. It was also demonstrated that if ionization constant values are known, the CE separations of the studied peptides can easily be predicted taking into account the classical semiempirical relationships between electrophoretic mobility and charge-to-mass ratio (me versus q/Mα). The separations simulated considering the accurate charge-to-mass ratios of each peptide at a certain pH value were in good agreement with the experimental results.Once an optimum separation pH value and a running buffer compatible with electrospray mass spectrometry (ESI) detection were selected, a method for the separation and characterization of this series of analytes by capillary electrophoresis-electrospray ionization mass spectrometry (CE-ESI-MS) was established using a commercial sheath-flow interface. Method validation was performed in order to prove the suitability of the proposed method for quantitative analysis. Thus, quality parameters, such as repeatability, reproducibility, limits of detection and linearity were determined.  相似文献   

16.
The presented study deals with the off-line coupling of preparative isotachophoresis (pITP) with on-line combination of capillary zone electrophoresis with electrospray mass spectrometric detection (CZE-ESI-MS) used for the analysis of therapeutic peptides (anserine, carnosine, and buserelin) in complex matrix (urine). Preparative capillary isotachophoresis, operating in a discontinuous fractionation mode in column-coupling configuration, served as a sample pretreatment technique to separation, and fractionation of mixture of therapeutic peptides present in urine at low concentration level. The fractions isolated by pITP procedure were subsequently analyzed by capillary zone electrophoresis with electrospray mass spectrometric detection. Acetic acid at 200 mmol L(-1) concentration served as background electrolyte in CZE stage and it is compatible with MS detection in positive ionization mode. In pITP fractionation procedure, sodium cation (10 mmol L(-1) concentration) as leading ion and beta-alanine as terminating ion (20 mmol L(-1) concentration) were used. While using CZE-ESI-MS, the limits of detection were 0.18 μg mL(-1) for carnosine, 0.17 μg mL(-1) for anserine and 0.64 μg mL(-1) for buserelin in water and 0.19 μg mL(-1) for carnosine, 0.50 μg mL(-1) for anserine and 0.74 μg mL(-1) for buserelin in 10 times diluted urine, respectively. The cleaning power of pITP sample pretreatment was proved as the peptides provided the higher MS signals at lower concentration levels resulting from the minimized matrix effects. The quality of obtained MS/MS spectra was very good so that they can provide information about the structure of analytes, and they were used for verification of the analytes identities. The pITP pretreatment improved the detection limits of the analyzed therapeutic peptides at least 25 times compared to the CZE-ESI-MS itself.  相似文献   

17.
Kim J  Zand R  Lubman DM 《Electrophoresis》2003,24(5):782-793
Several semiempirical models for peptide electrophoretic mobility have been tested for capillary electrophoresis (CE) separation with a positively charged capillary using on-line CE combined with electrospray ionization-mass spectrometry (ESI-MS). In the current system with pH 2.7, the expression q/M(0.56) provided the best correlation with the electrophoretic mobility in the analysis of a set of 18 standard samples, where q is the calculated net charge and M is the molecular weight. The peptides resulting from various digests of horse heart myoglobin or bovine hemoglobin were used to demonstrate the validity of this correlation. Post-translationally modified peptides from tryptic digest of human myelin basic protein were also investigated and were found to provide excellent correlation with the linear plot when the total charge of the peptide was correctly calculated. If the total charge was not properly calculated then the post-translationally modified peptides fell off the linear plot. Using this method five arginine residues (residues 5, 49, 54, 97 and 130) were found to be partially citrullinated, four glutamine residues (residues 8, 103, 121 and 147) were found to be partially deamidated and both methionines at residues 21 and 167 were found to be partially oxidized. Three peptides were found with phosphorylation; TPPPSQGK (residue 98 to 105), FSWGAEGQR (residue 114 to 122), and SGSPMAR (residue 163 to 169) and Arginine at 107 was found to be partially monomethylated or dimethylated. The method may provide an excellent means of identifying the presence of peptides with post-translational modifications in conjunction with MS.  相似文献   

18.
Zhao SS  Zhong X  Chen DD 《Electrophoresis》2012,33(8):1322-1330
An atmospheric ion lens incorporated into an electrospray ion source for capillary electrophoresis-mass spectrometry (CE-MS) is found to extend the stable operational regions for both flow rates and electrospray ionization (ESI) voltages. The stable operating conditions for the ESI source with and without the ion lens were characterized. The results showed that the stable operation region was widest when the voltage difference between the sprayer and the ion lens ranges from 2.6 to 2.8 kV, and under these condition, the CE-MS interface can be adapted to a broader range of electroosmotic and modifier flow rates. Modeling of the electric field in the electrospray ion source with the ion lens suggests that the extension of the stable region is attributed to the flatter equipotential surfaces around the sprayer tip and higher electric field strengths in the rest of the interface region.  相似文献   

19.
We describe a novel electrospray tip design for MS which is fabricated completely out of SU-8 photoepoxy. A three-layer SU-8 fabrication process provides fully enclosed channels and tips. The tip shape and alignment of all SU-8 layers is done lithographically and is therefore very accurate. Fabrication process enables easy integration of additional fluidic functions on the same chip. Separation channels can be made with exactly the same process. Fluidic inlets are made in SU-8 during the fabrication process and no drilling or other postprocessing is needed. Channels have been fabricated and tested in the size range of 10 microm x 10 microm-50 microm x 200 microm. Mass spectrometric performance of the tips has been demonstrated with both pressure-driven flow and EOF. SU-8 microtips have been shown to produce stable electrospray with EOF in a timescale of tens of minutes. With pressure driven flow stable spray is maintained for hours. Taylor cone was shown to be small in volume and well defined even with the largest channel cross section. The spray was also shown to be well directed with our tip design.  相似文献   

20.
Pelzing M  Neusüss C 《Electrophoresis》2005,26(14):2717-2728
Liquid chromatography (LC) nanoelectrospray-tandem mass spectrometry (MS/MS) is a key technology for the study of proteomics, with the main benefit to the characterization of sensitive peptides from complex mixtures. Capillary electrophoresis coupled to mass spectrometry (MS) has been taken into consideration sporadically due to the highly efficient separation and ability to handle low sample amount, yet classified as being less sensitive with respect to analyte concentration. The limitation in capillary zone electrophoresis (CZE) injection volumes can be overcome by on-line solid-phase extraction (SPE). Such an on-line SPE-CZE system was explored in combination with an ion trap (IT) mass spectrometer. Thus, it was possible to inject more than 100 microL sample solution on to the CZE capillary. Concentration limits of detection as low as 100 amol/microL were demonstrated for a peptide standard. This SPE-CZE-microelectrospray ionization (ESI)-MS/MS setup was compared directly to nanoLC/nanoESI using the same sample of a tryptic digest of bovine serum albumin (BSA) as a reference standard. Measurements were made on one IT mass spectrometer with identical acquisition parameters. Both chromatography systems enabled the separation and detection of low levels of peptides from a mixture of moderate complexity, with most peptides identified using both techniques; however, specific differences were obvious. The nanoLC-MS is about five times more sensitive than the CZE-MS, yet the difference was less pronounced than expected. The CZE-MS technique showed reduced loss of peptides, especially for larger peptides (missed cleavages) and is about four times faster than the nanoLC-MS approach.  相似文献   