首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 335 毫秒
1.
A copper(II) ion-selective PVC membrane sensor based on 2-(1'-(4'-(1'-hydroxy-2'-naphthyl)methyleneamino)butyl iminomethyl)-1-naphthol (BHNB) as a novel Schiff base containing a sensing material has been successfully developed. The sensor exhibits a good linear response of 29 mV per decade within the concentration range of 10(-1)-10(-6) M of Cu2+. The sensor shows good selectivity for copper(II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. The BHNB-based sensor is suitable for use with aqueous solutions of pH 3.5-7.0 and displays minimal interference by Sr(II), Cd(II), Hg(II), Zn(II) and Pb(II), which are known to interfere with other previously suggested electrodes. The proposed membrane electrode was used as a sensor for determining the Cu(II) content in black tea samples. It was also applied as an indicator electrode in the potentiometric titration of Cu2+ ions with EDTA.  相似文献   

2.
A mercury(II) ion selective poly(aniline) solid contact electrode based on 2-mercaptobenzimidazol (2MBI) ionophore as a sulfur containing sensing material was successfully developed. The electrode exhibits a good linear response of 29.1 mV/decade (at 20 ± 0.2°C, r 2 = 0.997) within the concentration range of 1 × 10?2?1 × 10?7 M Hg(II). The composition of this electrode was: ionophore 0.100, polyvinylchloride (PVC) 0.330, dibutylphthalate (DBP) 0.470, potassiumtetrakis(4-chlorophenyl)borate (KTpCIPB) 0.090, and oleic acid (OA) 0.010. A poly(aniline) solid contact electrode based on 2MBI with DBP and OA plasticizers exhibited the best response characteristics of the results obtained for similarly coated wire type electrodes and solid contact electrodes based on only one DBP plasticizer. The electrode shows good selectivity for mercury(II) ions in comparison with alkali, alkaline earth, transition and heavy metal ions. This electrode is suitable for use with aqueous solutions of pH 3.3?C8.0 and the standard deviation in the measured EMF difference was ±0.5 mV in a mercury nitrate sample solution of 1.0 × 10?2 M and ±1.1 mV in a mercury nitrate sample solution of 1.0 × 10?3 M. The stabilization time was less than 15 min and the response time was less than 33 s. The electrode was applied as a sensor for the determination of Hg(II) content in a sea water sample and some amalgam alloys. The results show good correlation with data obtained by atomic absorption spectrometry.  相似文献   

3.
《Analytical letters》2012,45(4):659-673
Abstract

A mercury (II) ion‐selective polyvinyl chloride (PVC) membrane sensor based on ethylenediamine bisthiophenecarboxaldehyde (EDBT) as a novel nitrogen‐ and sulfur‐containing sensing material was successfully developed. The ionophore was produced through Schiff's base formation between ethylenediamine and 2‐thiophenecarboxaldehyde. These two reagents have the advantages of low cost and simple chemical compounds. Ortho‐nitro phenyl pentyl ether (o‐NPPE) as solvent and sodium tetraphenyl borate (NaTPB) as a lipophilic salt were chosen. The sensor exhibited a good linear response of 30.0±0.4 mV per decade within the concentration range of 10?7–10?2 and a detection limit of 7.0×10?8 mol L?1 Hg(II). The sensor showed good selectivity and fast response for the mercury (II) ion with respect to some alkali, alkaline earth, transition, and heavy metal ions. The EDBT–based sensor was suitable for aqueous solutions of pH range from 2.0 to 4.5. It can be used for about 3 months without any considerable divergence in potential. The formation constant of ionophore complex with Hg(II) ion was calculated by using the segmented sandwich membrane method. The structure of both the ionophore and its Hg(II) complex were examined using infrared spectra and elemental analysis. The proposed sensor was applied for the determination of Hg(II) content in some dental amulgum alloys and as an indicator electrode for potentiometric titration of Hg(II) ion with EDTA solution, as well as with I?, OH?, and IO3 ? ions. In addition, the solubility products of the previous ions were determined by using this sensor.  相似文献   

4.
Chen Q  Wu X  Wang D  Tang W  Li N  Liu F 《The Analyst》2011,136(12):2572-2577
A quartz crystal microbalance with dissipation monitoring (QCM-D) sensor was developed for highly sensitive and specific detection of mercury(II) ions (Hg(2+)) with a tunable dynamic range, using oligonucleotide-functionalized gold nanoparticles (GNPs) for both frequency and dissipation amplification. The fabrication of the sensor employed a 'sandwich-type' strategy, and formation of T-Hg(2+)-T structures in linker DNA reduced the hybridization of the GNPs-tagged DNA on the gold electrode, which could be used as the molecular switch for Hg(2+) sensing. This QCM-D mercury sensor showed a linear response of 10-200 nM, with detection limits of 4 nM and 7 nM for frequency and dissipation measurements, respectively. Moreover, the dynamic range of the sensor could be tuned by simply altering the concentration of linker DNA without designing new sensors in the cases where detection of Hg(2+) at different levels is required. This sensor afforded excellent selectivity toward Hg(2+) compared with other potential coexisting metal ions. The feasibility of the sensor was demonstrated by analyzing Hg(2+)-spiked tap- and lake-water samples with satisfactory recoveries. The proposed approach extended the application of the QCM-D system in metal ions sensing, and could be adopted for the detection of other analytes when complemented with the use of functional DNA structures.  相似文献   

5.
Preparation, characterization, and applications of a 1,10-phenanthrolinium cation (phenH(+))-sensitive potentiometric sensor are described. The sensor incorporates a liquid polymeric membrane consisting of phenH-tetraphenylborate, nitrophenyloctyl ether, and poly(vinyl chloride) as ion exchanger, plasticizer, and polymeric support, respectively. The sensor exhibits a fast and Nernstian response to phenH(+) over the concentration range of 6 x 10(-6)-2 x 10(-4) M with a monovalent cationic slope of 58.0+/-0.5 mV/log[phenH(+)] in acetate buffer of pH 4.2. The sensor is successfully applied to the monitoring of the potentiometric titration of Hg(II) and Cu(II) ions with phen solution in the presence of citrate and acetate buffers of pH 4.2, respectively. Sharp inflection breaks (90-180 mV) at 1:1 (metal:phen reaction) are obtained in the presence of chloride and thiocyanate background. This stoichiometry is explained by the formation of insoluble [HgCl(2)(phen)], [Hg(SCN)(2)(phen)], and [Cu(SCN)(2)(phen)] complexes. Optimization of each titration and the effect of foreign ions are evaluated. The method offers the advantages of adequate sensitivity, accuracy, and selectivity for the determination of mercury and copper in pharmaceutical, rock, and tea samples. The results are in good agreement with those obtained using the standard atomic absorption spectrometric and United States Pharmacopeial methods.  相似文献   

6.
Balaji T  Sasidharan M  Matsunaga H 《The Analyst》2005,130(8):1162-1167
A low cost, solid optical sensor for the rapid detection of low concentrations of Hg2+ in aqueous media was prepared by the monolayer functionalization of mesoporous silica with 5,10,15,20-tetraphenylporphinetetrasulfonic acid (TPPS), anchored by N-trimethoxysilylpropyl-N,N,N-trimethylammonium chloride (TMAC). The detection is based on the color change of TPPS from orange to green as a result of the formation of a charge-transfer complex with Hg2+. The intensity of the charge-transfer band varies linearly with Hg2+ in the concentration range from zero to 2.5 x 10(-7) mol dm(-3). The lower detection limit observed for Hg2+ concentration is 1.75 x 10(-8) mol dm(-3). The material exhibits good chemical and mechanical stability, and did not show any degradation of TPPS for a period of eight months. The sensor was applied for the analysis of various environmental samples. The effects of pH, sample volume, reaction time, amount of material, and the presence of foreign ions on the detection method are discussed.  相似文献   

7.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x 10(-7) M. The response time for the electrode is less than 30 s and the electrode can be used for more than 2 months with less than a 2 mV observed divergence in a potentials. The proposed electrode exhibits very good selectivity for mercury(II) ions over many cations in a wide pH range (pH 1 - 4). The electrode was also applied to the determination of a mercury(II) ion in vegetables and in Azolla filiculoides.  相似文献   

8.
李艳  柴雅琴  袁若  张丽娜  梁文斌  叶光荣 《分析化学》2007,35(10):1525-1528
研制了基于双氨基三唑硫醚为中性载体的阳离子选择性电极。实验表明,该电极对Hg2 具有良好的电位响应特性,在pH 2.0硝酸盐缓冲液中,电极电位呈近能斯特响应,线性响应范围为4.0 mg/L~20 g/L,斜率为33.4 mV/dec.(25℃),检出限为1.7 mg/L。该电极响应时间短(<10 s),pH范围较宽(1.3~3.3)。将该电极用于实际水样和二元混合溶液中Hg2 的检测,其结果令人满意。  相似文献   

9.
A simple, highly sensitive and selective carbon nanocomposite electrode has been developed for the electrochemical trace determination of mercury. This mercury nanocomposite sensor was designed by incorporation of thiolated amino acids capped AuNps into the carbon ionic liquid electrode (CILE) which provides remarkably improved sensitivity and selectivity for the electrochemical stripping assay of Hg(II). Mercury ions are expected to interact with amino acids through cooperative metal–ligand interaction to form a stable complex which provides a sensitive approach for electrochemical detection of Hg(II) in the presence of other metal ions. The detection limit was found to be 2.3 nM (S/N = 3) that is lower than the permitted value of Hg(II) reported by the Environmental Protection Agency (EPA) limit of Hg(II) for drinkable water. The proposed nanocomposite electrode exhibits good applicability for monitoring Hg(II) in tap and waste water.  相似文献   

10.
《中国化学快报》2020,31(10):2752-2756
Electrochemical analysis is a promising technique for detecting biotoxic and non-biodegradable heavy metals. This article proposes a novel composite electrode based on a polyaniline (PANi) framework doped with bismuth nanoparticle@graphene oxide multi-walled carbon nanotubes (Bi NPs@GO-MWCNTs) for the simultaneous detection of multiple heavy metal ions. Composite electrodes are prepared on screen-printed electrodes (SPCEs) using an efficient dispensing technique. We used a SM200SX-3A dispenser to load a laboratory-specific ink with optimized viscosity and adhesion to draw a pattern on the work area. The SPCE was used as substrate to facilitate cost-effective and more convenient real-time detection technology. Electrochemical techniques, such as cyclic voltammetry and differential pulse voltammetry, were used to demonstrate the sensing capabilities of the proposed sensor. The sensitivity, limit of detection, and linear range of the PANi-Bi NPs@GO-MWCNT electrode are 2.57 × 102 μA L μmol−1 cm−2, 0.01 nmol/L, and 0.01 nmol/L–5 mmol/L and 0.15 × 10−1 μA L μmol−1 cm−2, 0.5 nmol/L, and 0.5 nmol/L–5 mmol/L for mercury ion (Hg(II)) and copper ion (Cu(II)) detection, respectively. In addition, the electrode exhibits a good selectivity and repeatability for Hg(II) and Cu(II) sensing when tested in a complex heavy metal ion solution. The constructed electrode system exhibits a detection performance superior to similar methods and also increases the types of heavy metal ions that can be detected. Therefore, the proposed device can be used as an efficient sensor for the detection of multiple heavy metal ions in complex environments.  相似文献   

11.
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Hg(II) ions was prepared by using bis[5-((4-nitrophenyl)azo salicylaldehyde)] (BNAS) as a suitable neutral carrier. The sensor exhibits a Nernstian response for mercury ions over a wide concentration range (5.0×10−2-7.0×10−7 M) with a slope of 30±1 mV per decade. It has a response time of <10 s and can be used for at least 3 months without any measurable divergence in potential. The electrode can be used in the pH range from 1.0 to 3.5. The proposed sensor shows fairly good discriminating ability towards Hg2+ ion in comparison with some hard and soft metals. The electrode was used in the direct determination of Hg2+ in aqueous solution and as an indicator electrode in potentiometric titration of mercury ions.  相似文献   

12.
A highly La(III) ion-selective PVC membrane sensor based on N'-(1-pyridin-2-ylmethylene)-2-furohydrazide (NPYFH) as an excellent sensing material was successfully developed. The electrode shows a good selectivity for La(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor exhibits a wide linear response with slope of 19.2 +/- 0.6 mV per decade over the concentration range of 1.0 x 10(-6) - 1.0 x 10(-1) M, and a detection limit of 7.0 x 10(-7) M of La(III) ions. The sensor response is independent of pH in the range of 3.5-10.0. The proposed electrode was applied as an indicator electrode in potentiometric titration of La(III) ion with EDTA.  相似文献   

13.
This work reports a surface ion imprinting strategy in electropolymerized microporous poly(2-mercaptobenzothiazole) (MPMBT) films at the surface of glassy carbon electrode (GCE) for the electrochemical detection of Hg(II). The Hg(II)-imprinted MPMBT/GCE exhibits larger binding to functionalized capacity, faster binding kinetics and higher selectivity to template Hg(II) due to their high ratio of surface-imprinted sites, larger surface-to-volume ratios, the complete removal of Hg(II) templates and larger affinity to Hg(II). The square wave anodic stripping voltammetry (SW ASV) response of the Hg(II)-imprinted MPMBT/GCE to Hg(II) is ca. 3.0 and 5.9 times larger than that at the direct imprinted poly(2-mercaptobenzothiazole) modified GCE and non-imprinted MPMBT/GCE sensor, respectively; and the detection limit for Hg(II) is 0.1 nM (which is well below the guideline value given by the World Health Organization). Excellent wide linear range (1.0–160.0 nM) and good repeatability (relative standard deviation of 2.5%) were obtained for Hg(II). The interference experiments showed that mercury signal was not interfered in the presence of Pb(II), Cd(II), Zn(II), Cu(II) and Ag(I), respectively. These values, particularly the high sensitivity and excellent selectivity compared favorably with previously reported methods in the area of electrochemical Hg(II) detection, demonstrate the feasibility of using the prepared Hg(II)-imprinted MPMBT/GCE for efficient determination of Hg(II) in aqueous environmental samples.  相似文献   

14.
A novel microsphere-based fluorescent sensor 1 for determination of Hg(II) in food samples has been successfully synthesized and its fluorescent sensing properties were investigated in detail. Polystyrene microsphere was innovatively surface modified by a rhodamine derivative; therefore sensor 1 was a fluorescent sensor with high polymer material properties of polystyrene and the optical properties of a fluorescent probe. Sensor 1 displayed high selectivity, good anti-interference performance, and instantaneous response to Hg(II). The fluorescence intensity of sensor 1 showed a linear response to Hg(II) in the concentration range of 0?µM to 8?µM with a detection limit of 0.439?µM. The most valuable advantage was that sensor 1 was recyclable and environmentally-friendly. This proposed sensor 1 was applied to monitor the content of Hg(II) in real food samples, such as tap water, rice, and anglerfish. The recovery range of tap water was from 92.60 to 105.80%, the recovery range of rice was from 90.45 to 106.10%, and the recovery range of anglerfish was from 91.30 to 105.84%. The relative error was below 10% in spiked recovery studies, suggesting that fluorescent sensor 1 provides a simple, efficient, and promising method for determination of Hg(II) in complex matrices.  相似文献   

15.
A sulfate ion-selective PVC membrane sensor based on 4-(4-bromophenyl)-2,6-diphenylpyrilium perchlorate (BDPP) as a novel sensing material is successfully developed. The electrode shows a good selectivity for sulfate ion with respect to common organic and inorganic anions. The sensor exhibits a good linear response with slope of -28.9+/-0.5 mV per decade over the concentration range of 1.0x10(-6)-1.0x10(-2) M, and a detection limit of 8.0x10(-7) M of SO(4)(2-) ions. The electrode response is independent of pH in the range of 4.0-9.0. The proposed sensor was applied as an indicator electrode in potentiometric titration of sulfate and barium ions, and to the determination of zinc in zinc sulfate tablets.  相似文献   

16.
Liangqia Guo 《Talanta》2009,79(3):775-311
A novel and simple oligodeoxyribonucleotide-based sensor with single fluorophore-labeled for mercury ion sensing was reported. An oligodeoxyribonucleotide poly(dT) was labeled with fluorescein as donor. Based on the specific binding of Hg(II) to T-T mismatch base pairs, the formation of π-stacked [T-Hg(II)-T] with “sandwich” structure on the addition of Hg(II) ions facilitates the electron transfer via photoinduced charge transfer (PCT), which creates an additional nonradiative decay channel for excited fluorophore and triggers the fluorescence to be quenched. The π-stacked [T-Hg(II)-T] functioned not only as mercury ion recognition but also as an electron acceptor to quench the donor. A linear relationship was observed over the range of 0-1.0 μM with the detection limit of 20 nM for mercury ions. The fluorescence quenching phenomenon and quenching mechanism, reliability and selectivity of the system were investigated in detail.  相似文献   

17.
A derivative of thiazole(AAT) has been explored as a sensing material for preparation a selective Lu(III) PVC-based membrane sensor.The proposed sensor exhibits a Nernstian response over a wide concentration range from 1.0×10-6 to 1.0×10-1 mol/L of Lu(Ⅲ) and the detection limit is 5.7×10-7 mol/L.The sensor response is independent of pH of the solution in the range 3.2-8.8 and possesses the advantages of fast response time(~6) and in particular,good selectivity to the lutetium ions with regard to most common metal ions,and especially all lanthanide ions.  相似文献   

18.
Liu B  Zeng F  Wu G  Wu S 《The Analyst》2012,137(16):3717-3724
The quenching of quantum dots' emission by some analytes (Hg(2+), Pb(2+), etc.) has long been hindering the fabrication of QD-based 'turn-on' or ratiometric fluorescent sensors for these analytes. In this study, we demonstrate a facile solution for constructing a robust FRET-based ratiometric sensor for Hg(2+) detection in water with CdTe QDs as the donor. By using the reverse microemulsion approach, CdTe QDs were first embedded into nanosized silica particles, forming the QDs/silica cores, a positively charged ultrathin spacer layer was then deposited on each QDs/silica core, followed by the coating of a mercury ion probe on the particle surfaces. The resultant multilayered QDs/silica composite nanoparticles are dispersible in HEPES buffered water; and in the presence of mercury ions, the QDs inside the nanoparticles will not be quenched by mercury ions due to the existence of the positively charged spacer layer, but can transfer their excited energy to the acceptors (probe/Hg(2+) complex), thus achieving the FRET-based ratiometric sensing for mercury ions in totally aqueous media. With its detection limit of 260 nM, this QD-based sensor exhibits high selectivity toward mercury ion and can be used in a wide pH range. This strategy may be used to construct QDs-based ratiometric assays for other ions which quench the emission of QDs.  相似文献   

19.
The selective and sensitive detection methods for toxic transition-metal ions, which are rapid, facile, and applicable to the environmental and biological milieus, are of great importance. In this study, we designed a β-CD-based ratiometric sensor for detecting mercury ions in aqueous media, some biological fluids, and live cells. In this sensing platform, the thiocarbamido-containing probe dye was covalently linked onto the hydrophilic β-CD rim, which is conducive to complexing with metal ion, while the donor dye was anchored inside hydrophobic β-CD cavity via the adamantyl moiety, which is good for avoiding self-aggregation and enhancing the quantum yield of the donor dye. Upon associating with mercury ion, the probe dye undergoes ring-opening process and serves as the energy acceptor and constitutes the FRET system with the donor dye; by this way ratiometric detection of mercury ion in water can be realized with the detection limit of 10 nM. The cyclodextrin plays a crucial role for the sensing system; it not only accommodates both the donor dye and the probe dye which can form FRET system upon addition of Hg(2+) but also makes the sensor water-soluble and cell membrane permeable. This nontoxic sensing platform can be used for mercury ion detection in aqueous medium, biological fluids, and live cells (L929 and Hela). We also found that, upon being taken up by L929 cells, the sensor exhibited no cytotoxicity, and the cell proliferation was not affected.  相似文献   

20.
Chen L  Lou T  Yu C  Kang Q  Chen L 《The Analyst》2011,136(22):4770-4773
An approach for mercury ions (Hg(2+)) sensing based on the Hg(2+)-induced aggregation of thymine (T)-SH-functionalized gold nanoparticles (AuNPs) has been reported. The T-SH ligands that we synthesized can easily be coupled to the surface of AuNPs through the Au-S bond and can recognize Hg(2+) with high selectivity by forming a T-Hg-T complex with strong affinity. For the T-SH-functionalized AuNPs (T-S-AuNPs) sensor, upon addition of Hg(2+), the formation of the T-Hg-T complex induces aggregation of T-S-AuNPs and results in a significant change of color and UV-Vis absorption spectra. Thus, our method can be used for the rapid, easy and reliable screening of Hg(2+) in aqueous solution, with high sensitivity (2.8 nM) and selectivity over competing analytes. The developed method is successfully applied to the sensing of Hg(2+) in real environmental samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号