Shi G  Liu M  Zhu M  Zhou T  Chen J  Jin L  Jin JY 《The Analyst》2002,127(3):396-400
A novel hypoxanthine (Hx) microsensor was constructed. In this work, Nafion xanthine oxidase (XOD) and Au colloid were immobilized onto the surface of a Pt microelectrode. The enzyme biosensor displayed a quick and sensitive response to Hx. Under physiological conditions, a low detection limit, with high selectivity and sensitivity for Hx determination were obtained. The oxidation current [investigated using current-time (I-t) plots] was linear with Hx concentration ranging from 2.0 x 10(-7) to 2.0 x 10(-5) mol L(-1) with a calculated detection limit of 1.0 x 10(-7) mol L(-1) (S/N of 3). The biosensor should be promising for in vivo measurement of Hx without interferences and fouling. The change of Hx concentration in cardiac myocytes stimulated by L-arginine (L-Arg) and acetylcholine (Ach) was also studied.  相似文献   

2.
The use of an amperometric biosensor for the salicylate determination in blood serum is described. The biosensor is based on salicylate hydroxylase (EC 1.14.13.1) electropolymerized onto a glassy carbon-working electrode with polypyrrole and glutaraldehyde, to improve the biosensor lifetime. The hexacyanoferrate (II) was also incorporated to work as a redox mediator to minimize possible interferences. The salicylate is enzymatically converted to catechol, which is monitored amperometrically by its electrooxidation at+0.170 V versus SCE (saturated calomel electrode). Salicylate determination was carried out maintaining the ratio between beta-NADH and salicylate at 4:1 (30 degrees C). The amperometric response of the biosensor was linearly proportional to the salicylate concentration between 2.3x10(-6) and 1.4x10(-5) mol l(-1), in 0.1 mol l(-1) phosphate buffer (pH 7.8), containing 0.1 mol l(-1) KCl and 5.0x10(-4) mol l(-1) Na(2)H(2)EDTA, as supporting electrolyte. The recovery studies, in the presence of several interfering compounds, showed recoveries between 96.4 and 104.8%. The useful lifetime of the biosensor in the concentration range evaluated was at least 40 days, in continuous use. Blood serum samples analyzed by this biosensor showed a good correlation compared to the spectrophotometric method (Trinder) used as reference, presenting relative deviations lower than 7.0%.  相似文献   

3.
A novel strategy for fabricating horseradish peroxidase (HRP)-based H(2)O(2) sensor has been developed by combining the merits of carbon sol-gel supporting matrix and nano-scaled particulate gold (nano-Au) mediator. The thiol functional group-derived carbon ceramic electrode (CCE) was first constructed using (3-mercaptopropyl) trimethoxy silane as sol-gel monomer. Then, the stable nano-Au monolayer was obtained through covalent linkage between nano-Au and thiol group on the surface of CCE. The experimental results showed that nano-Au monolayer formed not only could steadily immobilize HRP but also efficiently retain its bioactivity. Hydrogen peroxide was detected with the aid of hydroquinone mediator to transfer electrons between the electrode and HRP. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as the operating potential, mediator concentration and pH of background electrolyte were explored for optimum analytical performance of the enzyme electrode. The biosensor had a fast response of less than 8 s with linear range of 1.22 x 10(-5) to 1.10 x 10(-3)mol l(-1) and a detection limit of 6.1 x 10(-6)mol l(-1). The sensitivity of the sensor for H(2)O(2) was 0.29 A l mol(-1) cm(-2). The activation energy for enzyme reaction was calculated to be 10.1 kJ mol(-1). The enzyme electrode retained 75% of its initial activity after 5 weeks storage in phosphate buffer at pH 7.  相似文献   

4.
A biosensor based on vaseline/graphite modified with avocado tissue (Persea americana) as the source of polyphenol oxidase was developed and used for the chronoamperometric determination of paracetamol in pharmaceutical formulations. This enzyme catalyses the oxidation of paracetamol to N-acetyl-p-benzoquinoneimine whose electrochemical reduction back to paracetamol was obtained at a potential of -0.12 V. After addition of paracetamol reference solutions in glass cell and stirring for 60 s for the accumulation of N-acetyl-p-benzoquinoneimine at the electrode surface under open-circuit conditions, the current response was monitored by 120 s without stirring. The currents obtained at 70 s were proportional to the paracetamol concentration from 1.2x10(-4) to 5.8x10(-3) mol l(-1) (r=0.9927) with a detection limit of 8.8x10(-5) mol l(-1). The recovery of paracetamol from two samples ranged from 97.9 to 100.7% and a relative standard deviation lower than 0.5% for a solution containing 5.0x10(-3) mol l(-1) paracetamol in 0.10 mol l(-1) phosphate buffer solution (pH 7.0; n=10) was obtained. The results obtained for paracetamol in pharmaceutical formulations using the proposed biosensor and those obtained using a pharmacopoeial procedure are in agreement at the 95% confidence level.  相似文献   

5.
本文介绍了一种新型的酶传感器, 首次以具有一定规整结构的β沸石固定酶, 以7, 7', 8, 8'-四氰基醌二甲烷作为电子传递媒介体,研制成葡萄糖传感器, 运用傅利叶变换红外光谱研究了β沸石与葡萄糖氧化酶之间的相互作用, 通过载体孔径分布和等电点的测定, 研究了载体的孔结构及表面酸性质对酶吸附的影响规律, 并对电极的制备条件和响应性能进行了优化。  相似文献   

6.
Zhang W  Zha H  Yao B  Zhang C  Zhou X  Zhong S 《Talanta》1998,46(4):711-716
The electrochemical redox mechanism of I(-) ion under different concentrations on gold electrodes was studied in detail using the EQCM technique (a combination of the QCM technique and cyclic voltammetry). The redox behavior of the I(-) ion on a gold microelectrode when no supporting electrolyte was added was compared with a conventional gold microelectrode. Due to the small current and the very low solution iR drop of the microelectrode, the actual oxidation potential of I(-) on the microelectrode was much more negative than that of the conventional electrode and its anodic peak was better defined. Therefore the gold microelectode was employed for the determination of I(-). A linear range of 1.0x10(-5)-0.1 mol l(-1) with a detection limit of 1.0x10(-6) mol l(-1) was obtained on the microelectrode in pure KI aqueous solution. Two samples were measured using this method and the results were in good agreement with those indicated or calculated..  相似文献   

7.
Mano N  Kuhn A 《Talanta》2005,66(1):21-27
We propose a procedure to assemble monolayers of redox mediator, coenzyme, enzyme and stabilizing polyelectrolyte on an electrode surface using essentially electrostatic and complexing interactions. In a first step a monolayer of redox mediator, substituted nitrofluorenones, is adsorbed. In a second step, a layer of calcium cations is immobilized at the interface. It establishes a bridge between the redox mediator and the subsequently adsorbed coenzyme NAD+. In the next step we use the intrinsic affinity of the NAD+ monolayer for dehydrogenases to build up a multilayer composed of mediator/Ca2+/NAD+/dehydrogenase. The so obtained modified electrode can be used as a biosensor. Quartz crystal microbalance measurements allowed us to better understand the different parameters responsible for the adsorption. A more detailed investigation of the system made it possible to finally stabilize the assembly sufficiently by the adsorption of a polyelectrolyte layer in order to perform rotating disk electrode measurements with the whole supramolecular architecture on the electrode surface.  相似文献   

8.
A spectrophotometric enzymatic flow injection (FI) system for the determination of diethyl-p-nitrophenylphosphate (paraoxon) is proposed. The method was based on the determination of the acetic acid formed by the enzymatic reaction of the acetylcholinesterase, immobilized on glass beads, with the substrate acetylcholine. The acetic acid formed permeates through a PTFE membrane and is received by a solution (pH 7.0) containing the acid-base indicator Bromocresol Purple (B.C.P.), leading to a pH change and therefore to a color change. The variation of the absorbance of the solution is detected spectrophotometrically at 400 nm. The determination of paraoxon is related to its inhibitory action on the enzyme. Therefore the analytical signal is the difference between the signal that corresponds to the free and the one that corresponds to the inhibited enzyme, considering a fixed acetylcholine concentration. The correlation between the peak height and paraoxon concentration at a given acetylcholine concentration is linear in the range from 5.0 x 10(-7) mol L-1 to 5.0 x 10(-5) mol L-1 (r = 0.998) of paraoxon, with a relative estimated standard deviation (R.S.D.) of +/- 1.7% (n = 10) considering a solution containing 5.0 x 10(-6) mol L-1 of paraoxon and a solution containing 5.0 x 10(-3) mol L-1 of acetylcholine. Therefore, the quantitative limit detection is about 2.5 x 10(-7) of paraoxon (3 sigma). A 1,1'-trimethylene-bis(4-formylpyridinium bromide)dioxime (TMB-4) solution was used to reactivate the enzyme.  相似文献   

9.
Rapid determination of lactulose in milk by microdialysis and biosensors   总被引:1,自引:0,他引:1  
A simple and rapid flow system for the determination of lactulose in milk samples was developed. It is based on the hydrolysis of lactulose to galactose and fructose by the enzyme beta-galactosidase immobilised in a reactor. The amount of fructose produced was measured with an electrochemical biosensor based on the fructose dehydrogenase enzyme, K3[Fe(CN)6] as mediator and a platinum based electrochemical transducer. Parameters such as the enzyme immobilisation in the reactor and under the electrode surface, the lifetime of the beta-galactosidase reactor and of the dehydrogenase biosensor and the flow parameters were studied and optimised. Fructose was determined in the range 1 x 10(-6)-5 x 10(-3) mol l-1 with an RSD of about 2% and a detection limit of 5 x 10(-7) mol l-1. The use of a microdialysis probe as the sampling system permitted the direct measurement of lactulose in milk samples without pre-treatment in the range 1 x 10(-5)-5 x 10(-3) mol l-1. The sensitivity of the procedure allowed pasteurised, UHT and in-container sterilised milk to be distinguished.  相似文献   

10.
付萍  袁若  柴雅琴  殷冰  曹淑瑞  陈时洪  李宛洋 《化学学报》2008,66(15):1796-1802
在金电极表面修饰一层L-半胱氨酸,再利用静电吸附作用固定纳米普鲁士蓝(nano-PB),然后利用壳聚糖-纳米金复合膜将葡萄糖氧化酶(GOD)固定于修饰电极表面,制成新型的葡萄糖传感器.通过交流阻抗技术,循环伏安法和计时电流法考察了电极的电化学特性.在优化的实验条件下,该传感器在葡萄糖浓度为3.0×10-6~1.0×10-3 mol/L范围内有线性响应,检测下限为1.6×10-6 mol/L.此外该传感器具有响应快、稳定性好和选择性良好的特点,能有效排除常见干扰物质如抗坏血酸、尿酸等对测定的影响.  相似文献   

11.
将辣根过氧化物酶(HRP)通过纳米技术和自组装技术固定于电极表面,制得了酶修饰电极.纳米金与HRP形成了静电复合物并高效地保持了HRP的生物活性,以对苯二酚作为电子媒介体,差示脉冲伏安法(DPV)研究生物酶电极测定H2O2的线性范围为5.0×10-6~1.0×10-3 mol/L,检测限为2.5×10-6 mol/L,线性方程为△I=0.34765+4.05553CH2O2(mM).酶电极的表观米氏常数(K(app))为0.0675 mmol/L.实验同时证明该生物酶电极具有良好的稳定性和使用寿命.  相似文献   

12.
过氧化氢作为一种重要的化工产品在纺织行业、化工行业、造纸工业、环保行业、电子行业、食品卫生行业及其他领域得到广泛的应用~([1]).  相似文献   

13.
《Analytical letters》2012,45(8):1430-1442
Abstract

A novel fiber optic biosensor for the determination of adrenaline based on immobilized laccase catalysis and fluorescence quenching was designed and fabricated. The immobilized laccase formed by the immobilization of laccase on the CuTAPc-Fe3O4 nanoparticles composite were used to catalyze the oxidation of adrenaline and the fluorescent oxygen-sensing membrane was used to detect the consumption of oxygen. The effects of pH and temperature on laccase activity using adrenaline as the substrate were studied. The optimal pH and temperature for the activity of immobilized laccase are 5.0 and 55°C, respectively. The immobilized laccase has good thermal, storage and operation stability. The lock-in technology was used to detect the change of the life time of the oxygen-sensing membrane. By using ABTS as the electron mediator, the biosensor showed a response time of 30 sec. The biosensor has good performance in the adrenaline concentration ranges of 2.0 × 10?7 to 9.0 × 10?7 mol/l and 1.0 × 10?8 to 9.0 × 10?8 mol/l, and it also shows good stability.  相似文献   

14.
In this work, a renewable tyrosinase-based biosensor was developed for the detection of catechol, using a carbon black paste electrode, without any mediator. The effect of pH, type of electrolyte, and amount of tyrosinase enzyme were explored for optimum analytical performance. The best-performing biosensor in amperometric experiments at potential −0.2 V vs. Ag/AgCl (3 mol L−1 KCl) was obtained using a 0.1 mol L−1 phosphate buffer solution (pH 7.0) as electrolyte. Under optimized conditions, the proposed biosensor had two concentration linear ranges from 5.0×10−9 to 4.8×10−8 and from 4.8×10−8 to 8.5×10−6 mol L−1 and a limit of detection of 1.5×10−9 mol L−1. The apparent Michaelis-Menten constant ( ) was calculated by the amperometric method, and the obtained value was 1.2×10−5 mol L−1 whose result was similar when compared with other studies previously. The biosensor was applied in river water samples, and the results were very satisfactory, with recoveries near 100 %. In addition, the response of this biosensor for different compounds, taking into account their molecular structures was investigated and the results obtained showed no interference with the response potential of catechol. The electrochemical biosensor developed in this work can be considered highly advantageous because it does not require the use of a mediator (direct detection) for electrochemical response, and also because it is based on a low-cost materials that can be used with success to immobilise other enzymes and/or biomolecules.  相似文献   

15.
Diffusion coefficient measurements in microfluidic devices   总被引:2,自引:0,他引:2  
A glassy carbon electrode (GCE) modified with Pd/IrO(2) provides excellent electrocatalytic oxidation of hydrogen peroxide. Glucose oxidase (GOD) and xanthine oxidase (XOD) were co-immobilized on the modified electrode with a thin film Nafion coated on the enzyme layer to form a glucose (Glu)/hypoxanthine (Hx) sensor, without interference from electroactive species such as ascorbic acid (AA) and uric acid (UA). Its response was evaluated with respect to the enzyme amount on the electrode, pH and temperature of the electrolyte. The prepared bienzymic biosensor, used as the detector of HPLC gave a detection limit of 1.0x10(-6) mol l(-1) Glu and 2.0x10(-7) mol l(-1) Hx (Hx) with a linear concentration range of 5.0x10(-6)-2.5x10(-3) mol l(-1) and 1.0x10(-6)-5.0x10(-4) mol l(-1), respectively. Coupled with microdialysis, it was used to monitor the concentrations of Glu and Hx in rat brain.  相似文献   

16.
An enzymatic reactor was constructed by the immobilization of polyphenol oxidase (PPO) from avocado (Persea americana) crude extract in an inorganic support of controlled pore silica (CPS), after a previous step of silanization. This inorganic support has been used as an excellent carrier to immobilize this enzyme and the enzymatic reactor was used in a flow injection system for the determination of isoproterenol in pharmaceutical products. The procedure is based on the oxidation reaction of this drug with immobilized PPO and the product obtained was monitored at 492 nm. This system presented an analytical curve from 1.23x10(-4) to 7.38x10(-4) mol l(-1) isoproterenol with a detection limit of 6.25x10(-5) mol l(-1). Recoveries of isoproterenol between 98.5 and 103.1%, a relative standard deviation (R.S.D.) less than 1% (n=10) and 36 determinations per h were obtained.  相似文献   

17.
对长45 mm、内径0.9 mm的医用毛细管进行γ-氨丙基三乙氧基硅烷氨基化和戊二醛醛基化后,再将乳酸脱氢酶(LDH)的氨基与戊二醛的醛基结合,使其固定在毛细管内壁,构成一种新型固定化酶乳酸荧光毛细生物传感器(IE-LFCBS),实现了对乳酸的微量、快速测定.IE-LFCBS吸入辅酶Ⅰ与乳酸的混合液,在固定化酶催化下使乳酸与辅酶Ⅰ反应,生成荧光物质还原型辅酶Ⅰ;激发波长353 nm、发射波长466 nm.适用于IE-LFCBS的优化条件为:辅酶Ⅰ浓度4 mmol/L、用于固定化的LDH浓度60 kU/L、反应时间15 min、反应温度38 ℃、测定范围为1.0~5.0 mmol/L、回收率95%~98%,IE-LFCBS的相对标准偏差为RSD<1.5%(n=11),检出限为0.45 mmol/L.IE-LFCBS的试液用量极少(18 μL),并能重复使用,可望用于发酵食品、药品、血液标本等各类样品中乳酸的快速检测.  相似文献   

18.
Hemoglobin (Hb) was entrapped in a phosphatidylcholine (PC) film and immobilized at a pyrolytic graphite (PG) electrode surface. Its electron-transfer reactivity and enzyme activity were characterized by employing electrochemical methods. It was observed that Hb exhibited direct electrochemistry as well as enzyme-like activity towards the electrocatalytic reduction of NO in PC film. An unmediated, reagentless nitrogen oxide (NO) biosensor was accordingly prepared. Experimental results revealed that the peak current related to NO was linearly proportional to its concentration in the range of 1.0 x 10(-7)-3.0 x 10(-4) mol/L. The detection limit was estimated to be 1.0 x 10(-7) mol/L. Considering its good stability, nice selectivity and easy construction, this biosensor shows great promise for the rapid determination of traces of NO.  相似文献   

19.
The development and characterization of a highly sensitive enzyme immobilized carbon based electrode for the determination of subnanomolar concentrations of hydrogen peroxide in aqueous samples is described. The biosensor consists of horseradish peroxidase (HRP) immobilized in solid carbon paste along with a suitable redox mediator. The latter allows the acceleration of the electroreduction of HRP in the presence of hydrogen peroxide. Several phenothiazines as mediators are investigated in a comparative manner and with respect to dimethylferrocene using cyclic voltammetry and amperometry. Insolubilization of the HRP in the solid carbon paste is achieved by cross-linking the enzyme with glutaraldehyde and bovine serum albumin. Several experimental parameters such as pH, mediator and enzyme content are considered. The hydrogen peroxide determination is better carried out in 0.1 M acetate buffer, pH 4.5, by amperometry at an applied potential of 0.0 V versus Ag/AgCl, 3 M NaCl concentration and by using the phenothiazine base as redox mediator. The biosensor response is linear over the concentration range 2 nM-10 microM with a detection limit of 1 nM. The linear range of the hydrogen peroxide response without a mediator in the biosensor is found between 2 and 40 microM. The biosensor can be used for more than 180 measurements. Additional modification of the electrode by incorporation of Nafion SAC-13 microparticles in the solid carbon paste allows detection of concentrations of hydrogen peroxide as low as 0.1 nM.  相似文献   

20.
The development of biosensors has been one of the key areas in biotechnology and biomedical studies. Often it is difficult to investigate the immobilized biomolecules on the surfaces for biosensor optimization. Atomic force microscopy (AFM) should provide an ideal means for the visualization of biosensor surface and for the investigation of biomolecule activities. Therefore, AFM has been employed to study the surface topography of immobilized glutamate dehydrogenase (GDH) on two-dimensional glutamate biosensor surfaces. Correlation between the surface topography and the activity of the biosensor was investigated. Surface analysis has revealed that the enzymatic activity of the immobilized GDH molecules on the biosensor surface is linked to surface roughness, as measured by the peak-to-valley distance. Fractal dimension of the immobilization sensor surface was found to be a good parameter for judging the quality of the immobilized biosensors. As enzyme immobilization time increases, the biosensor has its maximum activity with around 18 h of immobilization in 10(-6) M GDH solution. Various biosensors prepared under different experimental conditions have been studied by AFM. This technique is shown to be an effective tool to characterize biosensor surfaces.  相似文献   