The influence of various factors such as solubility, the oxidation of the membrane, and the contamination of the solution, on the experimental values of the selectivity coefficients of solid state sulphide ion selective electrodes is discussed. A new method for the evaluation of very small selectivity coefficients, based on the addition of reagents forming complexes or insoluble salts with the main ion, is proposed. By means of this method, selectivity coefficients for silver, copper, cadmium and lead ion selective electrodes have been determined, which are in far better agreement with thermodynamic values than those described in the literature.  相似文献   

2.
Among the various analytical techniques available, the use of ion-selective electrodes is a wellestablished routine analytical technique. Good ion-selective electrodes (ISEs) possess many advantages over traditional methods for analysis and provide accurate, reproducible, fast, and regular selective determination of various ionic species. Modification of ISEs with nanoparticles has shown interesting ability toward various ions and biological molecules. In this article we review some of developments about applications of nanoparticles in the construction of ISEs in recent years.  相似文献   

3.
4.
The detection limit and the potentiometric selectivity coefficients of ion-selective electrodes are determined automatically with a microcomputer-controlled potentiometric system. Measurements of these parameters for three commercially available electrodes of the liquid membrane type (chloride, nitrate and calcium electrodes) gave results in good agreement with those reported in the literature. The non-linear least-squares fit evaluation of data (potential activities) and the selection of the appropriate transfer functions are described. The reproducibility of the results is discussed.  相似文献   

5.
A new potentiometric titration method for the determination of tantalum in sulfuric acid and hydrofluoric acid media is described. EMF's were monitored with a double-junction reference electrode and a flurortantalate ion selective indicator electrode made in this laboratory previously. Five titrants have been evaluated for the precipitation titration. CPC, BDTAC and TPA yield the highest precision and largest potentiometric breaks, then rank CETAB and Hyamine 1622 in turn. CPC is considered to be the most satisfactory owing to the most sharp end-point break yielded when 10^-^4M of Ta is titrated with it. The concentration of H2SO4 suitable for the titration is 0.18 to 1.8M and that of HF is 0.23 to 1.7M. The method is suitable for Ta content in the range of 0.5 to 150 mg with a coefficient of variation of 0.15% (9 results) for 20 mg of Ta. HCl, H3PO4, tartaric acid and (NH4)2C2O4 as wellas a large amount of Fe^3^+, Ni^2^+, Cr^3^+, WO2^-^4, Zr^4^+, La^3^+, Al^3^+, MoO2^-^4 and Nb^5^+ do not interfere, while ClO^-^4, H2O2 and BF^-^4 must be avoided. The method has been found to be very useful for the determination of Ta in steels and crystalline lithium tantalate. The results obtained are in good agreement with those of comparable methods. This method is very simple and provides a fast determination process.  相似文献   

6.
Properties of six derivatives of 1-trifluoroacetylbenzene: [4-(n-butyl)- (1), 4-(n-hexadecyl)- (2), 4-dodecyloxy- (3), 4-(n-dodecylsulfonyl)- (4), N,N-dioctyl-4-trifluoroacetylbenzamide (5), octyl-p-trifluoroacetylbenzoate (6)] as neutral carriers for carbonate ion were examined and compared. The sensitivity towards carbonate ion was for (3) pH dependent. This eliminates (3) from practical applications in clinical analysis. When measuring CO(3)(2-) within the physiological range of human blood using as carriers compounds 1 and 2 the interference of chloride must be taken into account. In the case of carriers 4, 5, 6 this effect is negligible. Electrodes with membranes containing as carriers 2, 4, 5 and 6 were tested in an automatic potentiometric clinical analyser Microlyte 6, KONE. To avoid contamination by atmospheric CO(2) of three aqueous standards (TES, NaCl, NaHCO(3)), pH was adjusted by coulomeric generation of H(+) or OH(-) in a system devoid of carbon dioxide. Recovery of HCO(3)(-) calculated from measured CO(3)(2-) and pH, was investigated in a series of aqueous solutions and spiked bovine serum samples. The correlation between added and recovered concentration of HCO(3)(-) was linear with the intercept close to 0 and slope equal to 1 in aqueous solutions for all ligands and in bovine serum samples only in the case of ligand (2).  相似文献   

7.
8.
The construction and performance characteristics of a novel chromate ion-selective membrane sensor are described and used for determining chromium(III) and chromium(VI) ions. The sensor is based on the use of a rhodamine-B chromate ion-associate complex as an electroactive material in a poly(vinyl chloride) membrane plasticized with o-nitrophenyloctyl ether as a solvent mediator. In a phosphate buffer solution of pH 6 - 7, the sensor displays a stable, reproducible and linear potential response over the concentration range of 1 x 10(-1) - 5 x 10(-6) mol l(-1) with an anionic Nernstian slope of 30.8 +/- 0.5 mV decade(-1) and a detection limit of 1 x 10(-6) mol l(-1) Cr(VI). High selectivity for Cr(VI) is offered over many common anions (e.g., I-, Br-, Cl-, IO4-, CN-, acetate, oxalate, citrate, sulfate, phosphate, thiosulfate, selenite, nitrate) and cations (e.g., Ag+, Ca2+, Sr2+, Co2+, Ni2+, Cu2+, Mn2+, Fe2+, Zn2+, Cd2+, Al3+, Cr3+). The sensor is used for determining Cr(VI) and/or Cr(III) ions in separate or mixed solutions after the oxidation of Cr(III) into Cr(VI) with H2O2. As low as 0.2 microg ml(-1) of chromium is determined with a precision of +/-1.2%. The chromium contents of some wastewater samples were accurately assessed, and the results agreed fairly well with data obtained by atomic absorption spectrometry.  相似文献   

9.
Zirconium(IV) phosphosulphosalicylate, a cation exchanger was synthesized by mixing zirconium oxychloride to a mixture of 5-sulphosalicylic acid and phosphoric acid. The material showed good efficiency for the preparation of an ion-selective membrane electrode. The membrane was characterized affinity for Pb(II) ions. Due to its Pb(II) selective nature, the ion-exchanger was used as an electroactive by XRD and SEM analysis. The electrode responds to Pb(II) ions in a linear range from 1 × 10−5 to 1 × 10−1 M with a slope of 43.8 mV per decade change in concentration with detection limit of 4.78 × 10−6 M. The life span of electrode was found to be 90 days. The proposed electrode showed satisfactory performance over a pH range of 4.0–6.5, with a fast response time of 15 s. The sensor has been applied to the determination of Pb(II) ions in water samples of different origins. It has also been used as indicator electrode in potentiometric titration of Pb(II) ion with EDTA.  相似文献   

10.
Mashhadizadeh MH  Shoaei IS  Monadi N 《Talanta》2004,64(4):1048-1052
A new PVC membrane potentiometric sensor that is highly selective to Fe(III) ions was prepared by using 2-[(2-hydroxy-1-propenyl-buta-1,3-dienylimino)-methyl]-4-p-tolylazo-phenol [HPDTP] as a suitable carrier. The electrode exhibits a linear response for iron(III) ions over a wide concentration range (3.5 × 10−6 to 4.0 × 10−2) with a super Nernstian slope of 28.5 (±0.5) per decade. The electrode can be used in the pH range from 4.5 to 6.5. The proposed sensor shows fairly a good discriminating ability towards Fe3+ ion in comparison to some hard and soft metals such as Fe2+, Cd2+, Cu2+, Al3+ and Ca2+. It has a response time of <15 s and can be used for at least 2 months without any measurable divergence in response characteristics. The electrode was used in the direct determination of Fe3+ in aqueous samples and as an indicator electrode in potentiometric titration of Fe(III) ions.  相似文献   

11.
A screen-printed electrode (SPE) was fabricated for the determination of 1-(ethoxycarbonyl)pentadecyltrimethylammonium bromide (Septonex) based on the use of Septonex-tetraphenylborate as the electroactive substance, and o-nitrophenyloctylether (o-NPOE) as the plasticizing agent. The electrode passes a near-Nernstian cationic slope of 59.33 ± 0.85 mV from activity between pH values of 2 to 9 with a lower detection limit of 9×10(-7) M and response time of about 5 s and exhibits an adequate shelf-life of 6 months. The method was applied for the determination of Septonex in pharmaceutical preparations. A percentage recovery of 99.88% was obtained with RSD=1.24%. The electrode was successfully applied in the determination of Septonex in laboratory-prepared samples by direct potentiometric, calibration curve and standard addition methods. Potentiometric titration of Septonex with sodium tetraphenylborate and phosphotungstic acid as a titrant was monitored with the modified screen-printed electrode as an end-point indicator electrode. Selectivity coefficients for Septonex relative to a number of potential interfering substances were determined. The sensor was highly selective for Septonex over a large number of compounds. Selectivity coefficient data for some common ions show negligible interference; however, cetyltrimethylammonium bromide and iodide ions interfere significantly. The analytical usefulness of the proposed electrode was evaluated by its application in the determination of Septonex in laboratory-prepared pharmaceutical samples with satisfactory results. The results obtained with the fabricated sensor are comparable with those obtained by the British Pharmacopeia method.  相似文献   

12.
Summary It has been shown that in the photochemical reduction method for the volumetric estimation of iron, there is no interference by chromium, titanium, tungsten, molybdenum, manganese, cobalt, nickel and fluoride. This method is therefore recommended for a rapid determination of iron in alloys and ores without the elimination of these interfering ions. Vanadium, however, was found to give slightly higher values for iron.Our thanks are due to Prof. G.Gopala Rao for his kind interest in the work.  相似文献   

13.
14.
Egorov VV  Bolotin AA 《Talanta》2006,70(5):1107-1116
The influence of the ISE membrane composition on the selectivity for primary, secondary, tertiary, and quaternary alkylammonium cations, as well as for cations of physiologically active amines, has been investigated. Factors studied include the effect of plasticizer (2-nitrophenyl octyl ether, o-NPOE; dibutyl phthalate, DBP; dinonyl adipate, DNA; tris(2-ethylhexyl) phosphate, TEHP) and ion exchanger (potassium tetrakis(4-chlorophenyl)borate, K(TpClPB); potassium tris(nonyloxy)benzenesulfonate, K(TNOBS)), as well as that of the lipophilic cationic additive (tetradecylammonium nitrate, (TDA)NO(3)) and neutral carrier (dibenzo-18-crown-6) presence in membrane. It has been established that plasticizer nature affects K(i,j)(pot) values both when the target and/or foreign ions have non-ionic polar groups capable of specific interaction with plasticizer, and when the only difference consists in the substitution degree of their ionic groups. K(i,j)(pot) values for quaternary alkylammonium cations over primary-tertiary ones change in the following order: TEHP>DBP approximately DNA>o-NPOE. The highest K(i,j)(pot) value change is achieved for the primary-quaternary alkylammonium cation pair, amounting to 3 and 4.7 orders for membranes containing K(TNOBS) and K(TpClPB) as ion exchangers, respectively. In its turn, the ion exchanger influence on the selectivity depends on plasticizer nature, it being maximal for o-NPOE (about 2 orders) and practically non-existent for TEHP. On the whole, as compared to K(TpClPB)-based ISEs, those based on K(TNOBS) show higher selectivity for primary-tertiary alkylammonium cations over quaternary ones. Incorporation of (TDA)NO(3) into membrane causes further improvement of selectivity for primary-tertiary alkylammonium cations in the case of K(TNOBS) only. The maximal total effect of the ion exchanger and lipophilic ionic additive is observed for ISEs with DNA-plasticized membranes and is over 3 orders. The influence of crown ether on the selectivity also depends significantly upon ion exchanger and plasticizer nature. For ISEs with o-NPOE-plasticized membranes the K(i,j)(pot) value changes can be as great as 3 (ion exchanger K(TNOBS)) and even 4.5 (ion exchanger K(TpClPB)) orders. On the contrary, for ISEs with TEHP-plasticized membranes the crown ether effect on the selectivity is unessential. The results obtained are explained by peculiarities of organic ammonium cations solvating by plasticizer and association of cations with ion exchangers.  相似文献   

15.
16.
Detailed investigations have been reported on the application of a common procedure using bromate in nitric acid for the removal of the interference of sulfide in the direct potentiometric determination of chloride using silver-based ion selective electrodes in a flow injection system. It is shown that this procedure is not very efficient and carries a high risk of chloride underestimation. With increasing levels of sulfide the oxidation of chloride to elemental chlorine becomes progressively significant and under certain circumstances virtually no chloride is left irrespective of its initial concentration. Hydrogen peroxide in alkaline medium is proposed as a suitable alternative for the efficient removal of sulfide without any adverse effects on the potentiometric method.  相似文献   

17.
Midgley D 《Talanta》1979,26(4):261-266
A number of solid-state ion-selective electrodes for the potentiometric determination of phosphate have been made and their properties investigated. The most successful of these electrodes, which had a membrane comprising silver sulphide, lead sulphide and lead hydrogen phosphate, had a theoretical Nernstian response to orthophosphate ion at concentrations down to 5 mug/ml total phosphate at pH 8.3. The electrode had a slow response and its standard potential changed with time. Anions such as sulphate, bicarbonate and nitrate did not interfere; chloride had a transient effect, but even at its worst the interference was less serious than with other phosphate electrodes. The electrode was used as an indicator in the potentiometric precipitation titration of phosphate and lanthanum.  相似文献   

18.
This paper describes the development of screen-printed (SPE) and carbon paste (CPE) sensors for the rapid and sensitive quantification of naphazoline hydrochloride (NPZ) in pharmaceutical formulations. This work compares the electroactivity of conventional carbon paste and screen-printed carbon paste electrodes towards potentiometric titration of NPZ. The repeatability and accuracy of measurements performed in the analysis of these pharmaceutical matrices using new screen printed sensors were evaluated. The influence of the electrode composition, conditioning time of the electrode and pH of the test solution, on the electrode performance were investigated. The drug electrode showed Nernstain responses in the concentration range from 1 × 10(-6) to 1 × 10(-2) mol L(-1) with slopes of 57.5 ± 1.3 and 55.9 ± 1.6 mV per decade for SPE and CPE, respectively, and was found to be very precise and usable within the pH range 3-8. These sensors exhibited a fast response time (about 3 s for both SPE and CPE, respectively), a low detection limit (3.5 × 10(-6) and 1.5 × 10(-6) M for SPE and CPE, respectively), a long lifetime (3 and 2 months for SPE and CPE, respectively) and good stability. The selectivity of the electrode toward a large number of inorganic cations, sugars and amino acids was tested. It was applied to potentiometric determination of NPZ in pure state and pharmaceutical preparation under batch conditions. The percentage recovery values for the assay of NPZ in tablets (relative standard deviations ≤0.3% for n = 4) were compared well with those obtained by the official method.  相似文献   

19.
Ion selectivity coefficients of ion-selective electrodes based on neutral carriers are described by means of a mixed potential model of ion transport reactions at the aqueous solution/ion-sensitive membrane interface. The decrease in ion selectivity can be explained by the deviations from the equilibrium conditions, which arise from the ionic partial current across the interface, but the proposed correspondence of the exchange current density of ion transfer reactions with the ion selectivity coefficients is rationalized only for certain conditions of the kinetic parameters. The ion selectivity for liquid membrane transport is discussed starting from three different rate-determining steps. It is shown that the potentiometric selectivities of ion-selective electrodes and the transport selectivities are correlated when the ionic transfer across the aqueous solution/ membrane interface is fast compared with the complex ion transport through the membrane. The significance of a kinetic approach for the design of neutral carriers for ion-selective electrodes is stressed.  相似文献   

20.
Potentiometric sensing utilizing textile-based micro-volume sampling was applied and evaluated for the determination of clinically (Na+, K+, Cl) and environmentally (Cd2+, Pb2+ and pH) relevant analytes. In this technological design, calibration solutions and samples were absorbed into textiles while the potentiometric cells (ion-selective electrodes and reference electrode) were pressed against the textile. Once the liquid, by wicking action, reached the place where the potentiometric cell was pressed onto the textile, hence closing the electric circuit, the potentiometric response was obtained. Cotton, polyamide, polyester and their blends with elastane were applied for micro-volume sampling. The textiles were found to influence the determination of pH in environmental samples with pH close to neutral and Pb2+ at low analyte concentrations. On the other hand, textile-based micro-volume sampling was successfully applied in measurements of Na+ using solid-contact sodium-selective electrodes utilizing all the investigated textiles for sampling. It was found that in order to extend the application of textile-based sampling toward environmental analysis of ions it will be necessary to tailor the physio-chemical properties of the textile materials. In general, textile-based sampling opens new possibilities for direct chemical analysis of small-volume samples and provide a simple and low-cost method to screen various textiles for their effects on samples to identify which textiles are the most suitable for on-body sensing.  相似文献   