首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hua MY  Chen HC  Tsai RY  Lai CS 《Talanta》2011,85(1):631-637
The imine of polybenzimidazole (PBI) is chemically oxidized by hydrogen peroxide (H2O2) in the presence of acetic acid (AcOH). Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopies (XPS) showed that when the AcOH concentration remained constant, the degree of oxidation increased with increasing H2O2 levels. Moreover, the imine also exhibited electrochemical redox behavior. Based on these properties, a PBI-modified Au (PBI/Au) electrode was developed as an enzyme-free H2O2 sensor. At an applied potential of −0.5 V vs. Ag/AgCl, the current response of the PBI/Au electrode was linear with H2O2 concentration over a range from 0.075 to 1.5 mM, with a sensitivity of 55.0 μA mM−1 cm−2. The probe had excellent stability, with <5% variation from its initial response current after storage at 50 °C for 10 days. Potentially interfering species such as ascorbic or uric acid had no effect on sensitivity. Sensitivity improved dramatically when multiwalled carbon nanotubes (MWCNT) were incorporated in the probe. Under optimal conditions, the detection of H2O2 using a MWCNT-PBI/Au electrode was linear from 1.56 μM to 2.5 mM, with a sensitivity of 928.6 μA mM−1 cm−2. Analysis of H2O2 concentrations in urine samples using a MWCNT-PBI/Au electrode produced accurate real-time results comparable to those of traditional HPLC methods.  相似文献   

2.
Chen H  Lin L  Lin Z  Lu C  Guo G  Lin JM 《The Analyst》2011,136(9):1957-1964
A flow-injection chemiluminescence (CL) system with high sensitivity, selectivity, rapidity, and reproducibility is proposed for the determination of hydrogen peroxide (H(2)O(2)) in water samples. The system is based on the reaction of hydrogen peroxide and hydrogen carbonate solution. Carbon nanospheres (CNSs) prepared from aqueous glucose solution are used to enhance the weak CL. The CL intensity was found to be directly proportional to the concentration of H(2)O(2) present in the sample solutions. The effects upon the CL of several physicochemical parameters, including the concentration of the reagents, the mixing order of the reagents, flow rate, pH, particle size of CNSs and other relevant variables, were studied and optimized. The proposed method exhibited advantages in a larger linear range of 5.0 × 10(-8) to 3.0 × 10(-6) mol L(-1) and a lower limit of detection of 1.0 × 10(-9) mol L(-1) (S/N = 3). This method has been successfully applied to the evaluation of H(2)O(2) in tap water and snow water with recoveries from 80 to 110%. The relative standard deviation (RSD) was less than 8% for intra- and inter-assay precision. Based on the kinetic curve, the CL spectrum, fluorescence spectrum, UV-visible spectrum, and electron spin resonance (ESR) spectrum of NaHCO(3)-H(2)O(2)-CNSs system, a possible CL mechanism was proposed. Superoxide ion radical (˙O(2)(-)) and hydroxide radical (˙OH) were generated during the reaction of NaHCO(3) and H(2)O(2). They were the key intermediates for the production of hole-injected and electron-injected CNSs in the CL process.  相似文献   

3.
Abstract

This paper presents a novel technique for measuring soluble inorganic monophosphate in water based on high performance liquid chromatography and flow injection detection (IC-FI). The IC-FI technology was applied to irrigation water from the Macalister Research Farm in South Eastern Australia. Overland flow was measured exiting two irrigation bays. Inorganic monophosphate constituted over 97% of the DRP component and between 86–93% of the total phosphorus. Similar results were obtained from a channel that drained the excess irrigation water from the farm. This work supports the findings of others that show DRP contributes a large portion of the P in runoff from grazing systems. Additionally, it confirms this fraction is dominated by immediately bioavailable inorganic monophosphate, something that previously could only be inferred due to the limitations of the chemistry applied.  相似文献   

4.
An overview of literature on the procedures for the chemiluminescence determination of hydrogen peroxide is presented.  相似文献   

5.
在碱性介质中,以四羧基铁酞菁为过氧化物酶模拟催化H2O2氧化邻苯二胺,生成2,3-二氨基吩嗪,该产物在577 nm处产生荧光,其荧光强度随H2O2浓度的增大而增加,在1.6×10-7~9.7×10-6mol/L范围内呈良好的线性关系,相关系数r为0.9941,据此建立了一种测定痕量H2O2的新方法。方法的检出限为1.1×10-7mol/L,用于雨水中H2O2的测定,结果令人满意。  相似文献   

6.
A chemiluminescence one-shot sensor for hydrogen peroxide is described. It is prepared by immobilization of cobalt chloride and sodium lauryl sulphate in hydroxyethyl cellulose matrix cast on a microscope cover glass. Luminol, sodium phosphate and the sample are mixed before use and applied on the membrane by a micropipette. The calibration graph is linear in the range 20-1600 μg/L, and the detection limit of the method (3σ) is 9 μg/L. A relative standard deviation of 4.5% was obtained for 100 μg/L H2O2 (n = 11). The sensor has been applied successfully to the determination of hydrogen peroxide in rainwater.  相似文献   

7.
Eight N -alkyl-N-V-sulphopropylaniline derivatives have been synthesized and assessed as water-soluble hydrogen donors for the spectrophotometric determination of hydrogen peroxide in the presence of peroxidase. The sodium salts of N-ethyl-N-sulphopropylaniline (ALPS), N-ethyl-N-sulphopropyl-m-toluidine (TOPS) and N -ethyl-N-sulphopropyl-m-anisidine (ADPS) are recommended. They have excellent water solubilities, and the optimum pH range for oxidative condensation with 4-aminoantipyrine in the presence of hydrogen peroxide and peroxidase is 5.5–9.5. The absorbances of the resulting chromogens are 2–3 times higher than that achieved with phenol. The molar absorptivities of the chromogens with 4-aminoantipyrine are 41300 (ALPS, λmax 561 nm), 37400 (TOPS, λmax 550 nm) and 27900 (ADPS, λmax 540 nm). Calibration graphs for the determination of hydrogen peroxide in the presence of a control serum are linear for 7–40 × 10-6 mol H2O2 l-1.  相似文献   

8.
A novel NMR method that allowed the rapid and direct quantitative analysis of hydrogen peroxide in protic solvents was developed. The method was based on the highly deshielded 1H NMR signal of the H2O2 protons (δ?~?11.15 ppm at 298 K) in H2O and the combined use of cryoprotective (antifreeze) mixtures of H2O?DMSO-d6, low temperatures (~260 K), and pH effects in order to achieve minimum proton exchange rate and, thus, sharp 1H line widths. Extremely broad resonances with line widths above 550 Hz at room temperature in H2O were observed in a wide range of pH values, which were reduced below 2 Hz with the use of the above method which resulted in a detection limit of 20.0 μmol L?1 (in tube) even when using very short total experimental time of 10 min. The method was applied in aqueous extract of Greek oregano and in aqueous instant coffee. Line widths below 10 Hz for oregano samples and 17 Hz for instant coffee samples were obtained which resulted (i) in the unequivocal assignment of H2O2 with spiking experiments precluding any confusion with interferences from intrinsic phenolics in the extracts and (ii) in the quantitative investigation of the evolution of H2O2 in real time with parameters easily accessible experimentally.
Figure
?  相似文献   

9.
An optimized and scalable synthesis of a novel analytical reagent for the determination of the number of active sites available for conjugation on a catalytic aldolase monoclonal antibody (mAb) is described. The original conditions suffered from lack of reproducibility, incomplete reactions, and required several chromatographies and lyophilizations that afforded material of low purity. A redesigned route and optimized protocols have been developed that eliminate the use of toxic and unsafe reagents such as HMPA and HATU. In addition, the number of chromatographies has been reduced to only one and time-consuming and energy-intensive lyophilizations are no longer required. The overall yield has been considerably improved from the original 4% to 20% after telescoping the last two steps of the synthesis and this new approach allowed for the preparation of material with higher chemical purity (?99% vs the initial 90%) to meet specifications.  相似文献   

10.
Spectrophotometric determination of hydrogen peroxide in rainwater   总被引:6,自引:0,他引:6  
Hydrogen peroxide in rainwater has been determined from the measurement of absorption at 432 nm after the formation of the stable oxo-peroxo-pyridine-2,6-dicarboxylatovanadate(V) complex (OPDV) in acid media. Determinations were in good agreement with those using a modified p-hydroxyphenylacetic acid (PHPA) emission method. The linear range for the OPDV method is from 0.05 to 50 ppm H2O2, and the limit of detection under the analytical conditions employed was 5.8 nmol H2O2 for a 20 cm3 rainwater sample. The volume weighted mean H2O2 concentration in rainwater collected at roof-top level in central Kowloon was 15.9 μM (N=10), and the ratio of non-sea salt sulphate and H2O2 concentrations was significantly correlated with pH. The OPDV absorption method was also employed for the determination of ambient gaseous H2O2, and liquid-nitrogen cold-trap collection gave results about 30% lower than impinger sampling, where artifact H2O2 formation occurred.  相似文献   

11.
Summary A method for the determination of gaseous hydrogen peroxide in ambient air is described. The cryogenic sampling technique (–45 ° C) employed represents an improvement compared with the impinger technique by diminishing artifacts which are bound to liquid phase production and decomposition, respectively. Results are given of H2O2 measurements from October 1984 to July 1985 in Dortmund (FRG), with mean concentrations of about 30 ppt (v/v). Preliminary results obtained with a coated denuder as a sampling device are also presented.
Methodik zur Bestimmung von gasförmigem Wasserstoffperoxid in Umgebungsluft
Zusammenfassung Ein Verfahren zur Bestimmung von gasförmigem Wasserstoffperoxid in Umgebungsluft wird beschrieben. Die vorgeschlagene Verwendung eines Kryo-Sammlers (–45 °C) stellt insofern eine Verbesserung gegenüber der bisher üblichen Waschflaschen-Probenahme dar, als damit die bei Absorption in flüssiger Phase beobachteten Artefakte — Bildung und auch Zersetzung von Wasserstoffperoxid — deutlich vermindert werden. Feldmessungen, die zwischen Oktober 1984 und Juli 1985 auf dem Gelände der Universität Dortmund durchgeführt wurden, ergaben mittlere H2O2-Gasphasenkonzentrationen um 30 pptv. Darüber hinaus werden die Ergebnisse erster Versuche mit beschichteten Diffusionsabscheidern als Sammler für gasförmiges Wasserstoffperoxid vorgestellt.


Dedicated to Prof. Dr. H. Monien on the occasion of his 60th birthday  相似文献   

12.
13.
The use of grape tissue as a source of catalase for the determination of hydrogen peroxide is reported. A slice of grape tissue attached to the membrane of a Clark-type oxgen sensor was used to monitor the oxidation of hydrogen peroxide by catalase. At the steady state, the sensor responds linearly to hydrogen peroxide in the concentration range 1 × 10?5–5 × 10?4 M. The response time (T90) was of the order of 1 min for this sensor. No interference was observed from ethanol, amino acids, glucose and lactic acid. The long-term stability of the grape tissue sensor was much better than previously reported immobilized enzyme and liver tissue-based hydrogen peroxide sensors.  相似文献   

14.
A new flow-injection procedure has been developed for the determination of salicylic acid based on the enhancement of the chemiluminescence from the cerium(IV)-Tween 20 reaction by salicylic acid in acidic medium. The method is simple, selective and sensitive with a detection limit of 2.5x10(-9) g mL(-1). It is applicable to the determination of salicylic acid in the concentration range of 4.0x10(-9)-1.1x10(-6) g mL(-1). The relative standard deviation (RSD) is 0.85% for 4.0x10(-7) g mL(-1) salicylic acid (n=11). The method has been successfully applied to the determination of salicylic acid in bactericidal solutions. Furthermore, it is suggested that light emission from cerium(IV)-Tween 20 reaction is probably because of the formation of singlet oxygen 1O2* and the emitter is excited oxygen molecular pairs O2(1delta(g))O2(1sigma(g)-).  相似文献   

15.
A sensitive chemiluminescent probe that selectively reacts with singlet oxygen in the presence of superoxide and hydrogen peroxide has been used to quantify the production of singlet oxygen in the reaction of superoxide with hydrogen peroxide. The yield of singlet oxygen from this reaction was found to be low (0.2% relative to the initial superoxide concentration). No evidence for the formation of hydroxyl radical was observed in this reaction, ruling out the Haber-Weiss mechanism as a major singlet oxygen formation pathway. No singlet oxygen production was observed in the reaction of superoxide with 2-nitrobenzoic acid, which has a pKa similar to that of hydrogen peroxide, rendering the protonation of superoxide, followed by its disproportionation, an unlikely explanation for the formation of singlet oxygen in this system. The low yields of singlet oxygen and hydroxyl radical suggest that their formation in this reaction should be relatively unimportant in biological systems.  相似文献   

16.
A novel ultrasonic flow injection chemiluminescence (FI-CL) manifold for determining hydrogen peroxide (H2O2) has been designed and evaluated. Chemiluminescence obtained from the luminol-H2O2-cobalt(II) reaction was enhanced by applying 120 W of ultrasound for a period of 4 s to the reaction coil in the FI-CL system and this enhancement was verified by comparison with an identical manifold without ultrasound. The system was developed for determining ultra-trace levels of H2O2 and a calibration curve was obtained with a linear portion over the range of 10-200 nmol L(-1) H2O2 (correlation coefficient 0.9945). The detection limit (3sigma) and the quantification limit (LOQ) were found to be 1 x 10(-9) and 3.3 x 10(-9) mol L(-1) respectively and the relative standard deviation was 1.37% for 2 x 10(-7) mol L(-1) H2O2 (n = 10). The method was applied to the determination of trace amounts of H2O2 in purified water and natural water samples without any special pre-treatments.  相似文献   

17.
McCurdy WH  Bell HF 《Talanta》1966,13(7):925-928
Direct titration of hydrogen peroxide in alkaline bromide media has been accomplished with sodium hypochlorite. The relative standard deviation is 0.2%. A photometric end-point is recommended for the determination of 0.10-1.0 mequiv of peroxide. Larger samples are evaluated by use of Bordeaux Red as visual indicator. The hypochlorite procedure compares favourably with iodometry and permanganate in the analysis of commercial peroxides.  相似文献   

18.
The electrode is based on the decomposition of H2O2 by an inorganic polymer catalyst. The steady -state decomposition currents of H202 obtained with the catalyst electrode are independent of ionic strength (0.1–1.5) and pH (2.5–10.5). A linear relationship is obtained from 0.02 to 2 mM H202 in 0.1 M KCl at 25°C.  相似文献   

19.
20.
Spectrofluorimetric determination of hydrogen peroxide scavenging activity   总被引:1,自引:0,他引:1  
Homovanillic acid (HVA) is widely used for the detection and imaging of oxidative enzymes—peroxidase, glucose oxidase and xanthine oxidase, but antioxidant activity has not been determined so far with the use of HVA. We have developed a simple, sensitive and in-field spectrofluorimetric method for the determination of hydrogen peroxide (H2O2) scavenging activity. The assay is based on the oxidation of HVA to its fluorescent biphenyl dimer in the presence of H2O2 and peroxidase. The presence of substances with H2O2 scavenging activity prevents the oxidation of HVA by removing H2O2. The decrease in fluorescence intensity is proportional to the antioxidative (H2O2 scavenging) activity. The method was evaluated using Trolox (6-hydroxy-2,5,7,8-tetramethylchromane-2-carboxylic acid), BHA (3-t-butyl-4-hydroxyanisole) and ferulic, vanillic, caffeic, chlorogenic, protocatechuic and oxalic acids. Additionally, tea and herb infusions known for their antioxidant properties were evaluated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号