首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Prussian Blue deposited on the electrode surface under certain conditions is known to be a selective electrocatalyst of hydrogen peroxide (H2O2) reduction in the presence of O2. The electrocatalyst was stabilized at cathodic potentials preventing its loss from the electrode surface. Hydrodynamic voltammograms of H2O2 reduction indicated the transfer of two electrons per catalytic cycle. The operational stability of Prussian Blue in H2O2 reduction was highly dependent on the buffer capacity of the supporting electrolyte. Since Prussian Blue is known to be dissolved in alkaline solution, it was confirmed that in neutral aqueous solutions the product of H2O2 electrocatalytic reduction is OH.  相似文献   

2.
Simple and sensitive DNA sensors have been developed on a base on graphite screen-printed electrodes modified with DNA and enzymes. Cholinesterase and peroxidase immobilized by treatment with glutaraldehyde were used for the detection of human DNA antibodies of systemic lupus erythematosus and bronchial asthma patients. The amperometric signal was measured at +680 mV versus Ag/AgCl for DNA-cholinesterase sensor and −150 mV for DNA-peroxidase sensor 5 min after the injection of acethylthiocholine and hydroquinone, respectively. The addition of serum samples results in the sharp decrease of the signal due to the formation of DNA-antibody adducts followed by the suppression of the access of substrate to the enzyme active site. Sulfonamide medicines suppress the DNA-antibody interaction due to the competitive binding along DNA minor grooves. DNA sensor labeled with peroxidase showed the linear calibration range of 5×10−9 to 7×10−5 mol l−1 of sulfamethoxazole and of 5×10−8 to 1×10−4 mol l−1 of sulfathiazole.  相似文献   

3.
A new method consisted of a dual-channel screen-printed electrode (DSPE) efficient modified with Prussian blue and acetylcholinesterase was developed for the rapid detection of organophosphorus pesticide residues.  相似文献   

4.
An interesting mode of reactivity of MnO2 nanoparticles modified electrode in the presence of H2O2 is reported. The MnO2 nanoparticles modified electrodes show a bi-direction electrocatalytic ability toward the reduction/oxidation of H2O2. Based on this property, a choline biosensor was fabricated via a direct and facile electrochemical deposition of a biocomposite that was made of chitosan hydrogel, choline oxidase (ChOx) and MnO2 nanoparticles onto a glassy carbon (GC) electrode. The biocomposite is homogeneous and easily prepared and provides a shelter for the enzyme to retain its bioactivity. The results of square wave voltammetry showed that the electrocatalytic reduction currents increased linearly with the increase of choline chloride concentration in the range of 1.0 × 10−5 –2.1 × 10−3 M and no obvious interference from ascorbic acid and uric acid was observed. Good reproducibility and stability were obtained. A possible reaction mechanism was proposed.  相似文献   

5.
Screen-printed carbon electrodes have been modified with tetrathiafulvalene and sulfite oxidase enzyme for the sensitive and selective detection of sulfite. Amperometric experimental conditions were optimized taking into account the importance of quantifying sulfite in wine samples and the inherent complexity of these samples, particularly red wine. The biosensor responds to sulfite giving a cathodic current (at +200 mV vs screen-printed Ag/AgCl electrode and pH 6) in a wide concentration range, with a capability of detection of 6 μM (α = β = 0.05) at 60 °C. The method has been applied to the determination of sulfite in white and red samples, with averages recoveries of 101.5% to 101.8%, respectively.  相似文献   

6.
通过一步电沉积技术制备了普鲁士蓝/氧化锆修饰玻碳电极。采用电化学阻抗技术表征修饰电极。采用循环伏安法研究了pH值和扫描速率对该修饰电极的电化学行为的影响。结果表明:普鲁士蓝的峰电流与其扫描速率的一次方在一定范围内呈良好的线性关系。此外,该修饰电极在含有KCl(1.0mol/L)的磷酸盐缓冲溶液(0.1mol/L,pH=7.0)中,对H2O2具有明显的电催化作用,在无酶检测H2O2领域具有潜在的应用价值。  相似文献   

7.
The screen-printed three-electrode system was applied to fabricate a new type of disposable amperometric xanthine oxidase biosensor. Carbon-working, carbon-counter and Ag/AgCl reference electrodes were all manually printed on the polyethylene terephthalate substrate forming the screen-printed three-electrode system by the conventional screen-printing process. As a mediator, Prussian blue could not only catalyze the electrochemical reduction of hydrogen peroxide produced from the enzyme reaction, but also keep the favorable potential around 0 V. The optimum operational conditions, including pH, potential and temperature, were investigated. The sensitivities of xanthine and hypoxanthine detections were 13.83 mA/M and 25.56 mA/M, respectively. A linear relationship was obtained in the concentration range between 0.10 μM and 4.98 μM for xanthine and between 0.50 μM and 3.98 μM for hypoxanthine. The small Michaelis-menten constant value of the xanthine oxidase biosensor was calculated to be 3.90 μM. The results indicate that the fabricated xanthine oxidase biosensor is effective and sensitive for the detection of xanthine and hypoxanthine.  相似文献   

8.
9.
The present work reports the application of a new molybdenum disulphide (MoS2)-based electrochemical platform for highly sensitive quantitation of an iron-binding protein, bovine serum albumin (BSA). The gold screen-printed electrodes were modified with MoS2 nanoflakes, followed by bioconjugation with anti-BSA antibodies. Using the above bioelectrode, cyclic voltammetric analysis was carried out in the presence of a Fe3+/Fe2+ redox probe which exhibited a linear response of peak current with varying concentrations of BSA up to 10 ng/mL (with a detection limit of 0.006 ng/mL). This study is novel in that it shows a considerable enhancement of signal during electrochemical sensing of a protein.  相似文献   

10.
A new electrochemical method has been described and characterized for the determination of cocaine using screen-printed biosensors. The enzyme cytochrome P450 was covalently attached to screen-printed carbon electrodes. Experimental design methodology has been performed to optimize the pH and the applied potential, both variables that have an influence on the chronoamperometric determination of the drug. This method showed a reproducibility of 3.56% (n = 4) related to the slopes of the calibration curves performed in the range from 19 up to 166 nM. It has been probed the used of this kind of biosensors in the determination of cocaine in street samples, with an average capability of detection of 23.05 ± 3.53 nM (n = 3, α = β = 0.05).  相似文献   

11.
Electropolymerisation of nonconducting polymer, poly-(1,2-diaminobenzene) on the top of Prussian Blue (PB) modified electrode led to significant improvement of resulting hydrogen peroxide transducer selectivity and operational stability. The reported transducer retained 100% of response during 20 h under the continuous flow of 0.1 mM H(2)O(2), and thus improves the stability level in selective peroxide detection by one order of magnitude. The selectivity value of the PB-poly(1,2-DAB) based H(2)O(2) sensor in relation to ascorbate is approximately 600. No signals to acetaminophen and urate were investigated. PB-poly(1,2-diaminobenzene) modified electrode allows the detection of H(2)O(2) in the flow-injection mode down to 10(-7) M with the sensitivity 0.3 A M(-1) cm(-2), which is only two times lower compared to the uncovered PB based transducer.  相似文献   

12.
Gurban AM  Rotariu L  Baibarac M  Baltog I  Bala C 《Talanta》2011,85(4):2007-2013
Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF6]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF6] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of −0.2 V vs. Ag/AgCl, in linear range from 5.5 to 97.7 μM for 4-t-octylphenol and respectively, between 5.5 and 140 μM for 4-n-nonylphenol, with a response time of about 5 s. The detection limit was 1.1 μM for 4-t-octylphenol, and respectively 0.4 μM for 4-n-nonylphenol (S/N = 3).  相似文献   

13.
《Electroanalysis》2006,18(21):2092-2098
Gold‐bead electrodes were modified by covalent bonding or physical adsorption of several Starburst PAMAM dendrimers (generations 2.0, 3.0 and 4.0) followed by absorption of Prussian Blue (PB). The covalent dendrimer‐PB‐modified electrodes can be used as amperometric sensors of H2O2 in aqueous solution. They offer enhanced sensitivity with correspondingly lower detection and quantification limits compared to similar amperometric detectors.  相似文献   

14.
A disposable amperometric immunosensor was studied for the rapid detection of Vibrio cholerae (V. cholerae), the causative agent of cholera, employing an indirect sandwich enzyme linked immunosorbent assay (ELISA) principle. Screen-printed electrodes (SPEs) were fabricated (by using commercial and homemade carbon inks), electrochemically characterized and the assay conditions were optimized for capturing antibodies and antigen. Whole cell lysate (WCL) of V. cholerae was used to raise antibodies in rabbits and mice. The antibodies raised against WCL of V. cholerae were found to be specific, and no cross reactivity was observed with other enteric bacteria. 1-Naphthyl phosphate was used as a substrate with the amperometric detection of its enzymatic hydrolysis product 1-naphthol at a potential of +400 mV vs. Ag/AgCl reference electrode. A comparison between the amperometric detection technique and the standard ELISA was made in terms of the total assay time, the amount of biological materials used and the sensitivity of detection. The minimum detection limit of the amperometric immunosensor for V. cholerae was found to be 10(5) cells/ml in 55 min, while ELISA detected 10(6) cells/ml in 4 h.  相似文献   

15.
Screen-printed electrodes coated with the nafion layer have been investigated for cholinesterase biosensor design. The butyrylcholinesterase (ChE) from horse serum was immobilised onto the nafion layer by cross-linking with glutaraldehyde vapours. The biosensors obtained showed better long-term stability and lower working potential in comparison to those obtained with no nafion coating. The sensitivity of a biosensor toward organophosphate pesticides is not affected by the nafion coating. The detection limits were found to be 3.5x10(-7) M for trichlorfon and 1.5x10(-7) M for coumaphos.  相似文献   

16.
A novel screen-printed biosensor for protein and amino acid (AA) estimation is reported. A rhodinised carbon paste working electrode (WE) was used in the three-electrode configuration. Bromine was generated by the electrolysis of an acidic potassium bromide electrolyte on the working electrode when poised at an appropriate potential. The consumption of bromine by the protein and amino acid was then measured at a lower potential. This sensor was used to detect most of the amino acids and some common proteins. The method is highly sensitive and can even detect L- and D- proline which give no response with enzyme electrodes. This sensor has also been used to detect protein/amino acid in fruit juice, milk, and urine. The unique feature of the sensor is that it does not require any reagent/chemical other than buffer. No surface treatment or modification of the WE is necessary and hence the sensor is stable for the lifetime of the basic screen-printed electrode, which is about a year. A very small amount of analyte (10 μL) is required for direct detection. The sensor is inexpensive and disposable and may also be used for continuous-flow systems. This sensor may have useful application in process monitoring and control during the production of amino acids.  相似文献   

17.
18.
The modification of carbon-paste electrodes by incorporation of the enzyme glucose oxidase (GOD) is described. The resulting probes can be operated as amperometric glucose sensors in the presence or absence of a mediator (1,1'-dimethylferrocene) mixed into the paste. Extended linear calibration ranges have been obtained up to 90 and 5OmM glucose respectively. The electrode responses were rapid, reaching steady-state values within 30-40 sec. Advantages of using a GOD-paste formulation are suggested. Plasma glucose assays were correlated with spectrophotometric determinations based on glucose oxidase (y = 1.07x - 0.16, r = 0.973, n = 17).  相似文献   

19.
In this paper, self‐assembled Prussian blue nanoparticles (PBNPs) on carbon ceramic electrode (CCE) were developed as a high sensitive hydrogen peroxide (H2O2) electrochemical sensor. The PBNPs film was prepared by a simple dipping method. The morphology of the PBNPs‐modified CCE was characterized by scanning electron microscopy (SEM). The self‐assembled PB film exhibited sufficient mechanical, electrochemical stability and high sensitivity in compare with other PB based H2O2 sensors. The sensor showed a good linear response for H2O2 over the concentration range 1 μM–0.26 mM with a detection limit of ca. 0.7 μM (S/N=3), and sensitivity of 754.6 mA M?1 cm?2. This work demonstrates the feasibility of self‐assembled PBNPs‐modified CCE for practical sensing applications.  相似文献   

20.
Carboxylated multiwalled carbon nanotubes (MWCNT-COOH) were used to modify the working electrode surface of different screen-printed electrodes. The effect of this modification on the electrodic characteristics (double layer capacitance, electroactive area and heterogeneous rate constants for the electron transfer) was evaluated and optimized for the cyclic voltammetric determination of p-aminophenol. The enzymatic hydrolysis of p-aminophenylphosphate was employed for the quantification of alkaline phosphatase, one of the most important label enzymes in immunoassays. Finally, ELISA assays were carried out to quantify pneumolysin using this enzymatic system. Results obtained indicated that low superficial densities of MWCNT-COOH (0.03-0.06 μg mm−2) yielded the same electrodic improvements but with better analytical properties.  相似文献   