1.
The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods the data agreed very well with the true values of the samples.  相似文献   

2.
建立了快速测定猪肝脏中恩拉霉素残留量的液相色谱-串联质谱(LC-MS/MS)分析方法。猪肝脏样品用0.1 mol/L盐酸-乙腈(3∶7,体积比)提取2次,离心收集上清液后,加入乙酸乙酯和正己烷液液萃取净化提取液,离心分层后吸取下层提取液经0.1%甲酸稀释定容后进行LC-MS/MS分析。采用Acquity BEH C18柱(100 mm×2.1 mm,1.7μm)进行色谱分离,以0.1%甲酸溶液-甲醇为流动相梯度洗脱;质谱采用电喷雾正离子(ESI+)模式电离,多反应监测(MRM)模式采集数据,基质校准外标法定量。恩拉霉素A和恩拉霉素B基质标准溶液在2.0~500μg/L质量浓度范围内与定量离子对峰面积呈良好的线性关系,方法检出限分别为3.0、4.0μg/kg,定量下限分别为10、12μg/kg,空白猪肝脏的加标回收率为80.8%~90.3%,批内相对标准偏差(RSD)为0.90%~4.5%,批间RSD为3.0%~4.3%。与已建立的方法比较,该方法简单快速,准确度和精密度均较好,能满足动物组织中恩拉霉素残留量分析的需要。  相似文献   

3.
软骨藻酸(domoic acid,DA)是一种由海洋硅藻产生的生物毒素,具有强烈的神经毒性,近海水环境中的DA严重威胁海洋渔业生物和人类健康,因此对近海水环境中的DA进行有效监测至关重要.该文基于固相萃取-液相色谱-串联质谱联用技术(SPE-LC-MS/MS),建立了适用于海水中痕量、超痕量DA的检测方法.针对近海水生...  相似文献   

4.
A miniaturized method based on matrix solid-phase dispersion coupled to solid phase extraction and high performance liquid chromatography with diode array detection (MSPD-SPE-HPLC/DAD) was developed for the trace simultaneous determination of the following organophosphorus pesticides (OPPs) in bovine tissue: parathion-methyl, fenitrothion, parathion, chlorfenvinphos, diazinon, ethion, fenchlorphos, chlorpyrifos and carbophenothion. To perform the coupling between MSPD and SPE, 0.05 g of sample was dispersed with 0.2 g of C(18) silica sorbent and packed into a stainless steel cartridge containing 0.05 g of silica gel in the bottom. After a clean-up of high and medium polarity interferences with water and an acetonitrile:water mixture, the OPPs were desorbed from the MSPD cartridge with pure acetonitrile and directly transferred to a dynamic mixing chamber for dilution with water and preconcentration into an SPE 20 mm × 2.0 mm I.D. C(18) silica column. Subsequently, the OPPs were eluted on-line with the chromatographic mobile phase to the analytical column and the diode array detector for their separation and detection, respectively. The method was validated and yielded recovery values between 91% and 101% and precision values, expressed as relative standard deviations (RSD), which were less than or equal to 12%. Linearity was good and ranged from 0.5 to 10 μg g(-1), and the limits of detection of the OPPs were in the range of 0.04-0.25 μg g(-1). The method was satisfactorily applied to the analysis of real samples and is recommended for food control, research efforts when sample amounts are limited, and laboratories that have ordinary chromatographic instrumentation.  相似文献   

5.
A simple, fast and sensitive liquid chromatography-mass spectrometry (LC-MS) method with automated on-line extraction using turbulent flow chromatography (TFC) for the determination of five catechins in human plasma was developed. In this method, after on-line extraction by its injection onto an extractor column at turbulent flow, five catechins were backwashed onto a reversed phase column via on-line column switching and separated chromatographically at a laminar flow of 1 ml min(-1). Using this tandem LC-LC-MS system, the extraction, the separation and the quantitation of five catechins in human plasma could be achieved with satisfactory selectivity and sensitivity. The limit of detection (S/N = 3) ranged from 0.6 to 2 ng ml(-1). The described procedure was very simple and rapid since no off-line sample preparation was required, total analysis time being 18.5 min.  相似文献   

6.
On-line coupling of SPE and CE-MS for peptide analysis   总被引:1,自引:0,他引:1  
An on-line SPE-CE-MS system has been developed for the analysis of peptides. Analytes are preconcentrated using a C(18) microcolumn (5 x 0.5 mm id), and then introduced into the CE system via a valve interface. The CE system with a Polybrene-poly(vinylsulfonate) bilayer coated capillary is combined with an ion-trap mass spectrometer via ESI using a coaxial sheath-liquid sprayer. The on-line coupling of the SPE and CE step by the valve interface is advantageous because it allows an independent functioning of the system parts. Optimization of the SPE-CE system was performed using UV detection. Subsequently, the SPE-CE system has been coupled to the ion-trap mass spectrometer. Test solutions with enkephalin peptides (50 ng/mL) were used for evaluation of system performance. Repeatability of effective mobility and peak area ratio of the two enkephalins were within 1.2% and 9% RSD, respectively. The analysis of 1:1 v/v diluted cerebrospinal fluid samples spiked with enkephalin peptides showed detection limits (S/N = 3) in the range of 1.5-3 ng/mL (around 5 nM), which were similar to those obtained for enkephalin test solutions. Moreover, the potential of the on-line SPE-CE-MS system was demonstrated by the analysis of a cytochrome C digest. Some hydrophilic peptides did not show sufficient retention on the SPE column, and were lost during preconcentration. Nonetheless, positive identification of the protein was achieved, indicating the feasibility of the system for proteomics.  相似文献   

7.
In this study, methodology was developed for on-line and miniaturized enzymatic digestion with liquid chromatographic (LC) separation and mass spectrometric (MS) detection. A packed capillary LC-MS system was combined with on-line trypsin cleavage of a model protein, lactate dehydrogenase, to provide an efficient system for peptide mapping. The protein was injected onto an enzymatic capillary reactor and the resulting peptides were efficiently trapped on a capillary trapping column. Different trapping columns were evaluated to achieve a high binding capacity for the peptides generated in the enzyme reactor. The peptides were further eluted from the pre-column and separated on an analytical capillary column by a buffer more suitable for the following an electrospray ionisation (ESI) MS process. An important aspect of the on-line approach was the desalting of peptides performed in the trapping column to avoid detrimental signal suppression in the ESI process. The developed on-line system was finally compared to a classical digestion in solution, with reference to peptide sequence coverage and sensitivity. It was shown that the on-line system gave more than 100% higher peptide sequence coverage than traditional digestion methods.  相似文献   

8.
A novel method was developed for the simultaneous determination of glucocorticoid residues such as triamcinolone (TR), prednisolone (PR), hydrocortisone (HC), cortisone (CO), methylprednisolone (MP), dexamethasone (DE) and triamcinolone acetonide (TA) by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection. The procedure was based on the enhancement effect of glucocorticoids on the chemiluminescence reaction between luminol and the complex of trivalent copper and periodate ([Cu(HIO6)2]5-), which was on-line electrogenerated by constant current electrolysis. The HPLC separation used a Nucleosil RP-C18 column (250 mmx4.6 mm i.d., 5 microm, pore size, 100 A) with a mobile phase consisting of acetonitrile and 1.0 mmol L(-1) ammonium acetate (pH 6.8, 40:60,v/v) at a flow rate of 0.8 mL min(-1). The effects of several parameters on the HPLC resolution and CL emission were studied systematically. Liver samples were hydrolyzed with Helix pomatia juice followed by a solid-phase extraction procedure. Under optimum conditions, the limits of detection (LOD) at a signal-to-noise of 3 ranged from 0.08 to 1.0 ng g(-1) and the limits of quantification (LOQ) at a signal-to-noise of 10 ranged from 0.27 to 3.33 ng g(-1) for seven glucocorticoids. The relative standard deviations (RSD) of intra- and inter-day precision were below 6.8%. The average recoveries for glucocorticoids (spiked at the levels of 5-50 ng g(-1)) in pig liver ranged from 88 to 106%, and the relative standard deviations of the quantitative results were from 2.0 to 6.9%. The proposed method had been successfully applied to the determination of glucocorticoid residues in pig liver.  相似文献   

9.
Bones J  Macka M  Paull B 《The Analyst》2007,132(3):208-217
A study comparing recently available 100 x 3 mm id, 200 x 3 mm id monolithic reversed-phase columns with a 50 x 2.1 mm id, 1.8 microm particle packed reversed-phase columns was carried out to determine the most efficient approach (using traditional van Deemter analysis and a modern kinetic plot approach) for the rapid screening of samples for 16 illicit drugs and associated metabolites. A plot of column backpressure versus plate number (N) showed a significant advantage of using the monolithic phases, with the 20 cm monolithic column exhibiting a maximum 15,000 plates at a column backpressure of approximately 70 bar, compared to approximately 7000 plates at 150 bar for the 5 cm 1.8 microm particle packed column. Optimum linear velocities were found to be 0.40 mm s(-1), 0.52 mm s(-1) and 0.98 mm s(-1) for the three above columns, respectively. The 20 cm monolithic column was subsequently applied to the separation and determination of illicit drug contamination on Irish euro banknotes, using methanol extraction followed by LC-MS/MS. Method performance data showed that the new LC-MS/MS method was significantly more sensitive than previous GC-MS/MS based methods for this application, with detection limits in the pg note(-1) region, based upon a 20 microL standard injection. All of the notes examined tested positive for trace quantities of cocaine, with benzoylecgonine detected on 12 of the 45 notes sampled. Traces of heroin were also detected on three of the 45 notes.  相似文献   

10.
液相色谱-串联质谱法测定食品中合成色素   总被引:1,自引:0,他引:1  
提出了液相色谱-串联质谱法测定食品中8种合成色素柠檬黄、苋菜红、胭脂红、日落黄、诱惑红、亮蓝、赤藓红和偶氮玉红的含量。固体(半固体)样品经乙醇-氨水-水(70+1+29)溶液溶解,所得滤液烘干后用水溶解,经Waters Atlantis dC18色谱柱(2.1 mm×150 mm,5μm)分离,用甲醇和10 mmol.L-1乙酸铵溶液以不同体积比混合进行梯度洗脱,采用电喷雾正离子模式串联质谱检测。8种合成色素的质量浓度均在50μg.L-1以内与其峰面积呈线性关系,检出限(3S/N)在0.003~0.020 mg.kg-1之间。方法应用于食品样品中8种合成色素的测定,回收率在83.0%~112.0%之间,测定值的相对标准偏差(n=6)均小于5%。  相似文献   

11.
The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 1 samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (>2 1 for all test analytes), reproducibility (R.S.D. of recoveries, 4–8%, n=3) and smapling speed (100 ml/min); detection limits in drinking water were 0.05–0.16 μg/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10×2.0 mm I.D. precolumn, were tested, and 50–200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1–0.3 min and R.S.D. of peak heights 4–14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05–1 μg/l in surface water.  相似文献   

12.
A methacrylate-based monolithic capillary column has been evaluated for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. For this purpose, the monolyte was in situ synthesized in a 6cm×0.32mm id fused-silica capillary. The microextraction unit was fitted to a micro-HPLC pump to pass 10mL of sample. The isolated pollutants were eluted by means of 10μL of methanol, the organic phase being directly collected in a specific interface that can be fitted to the injection port of the gas chromatograph without modification. The interface allows the on-line thermal desorption of the PAHs, avoiding the dilution and providing enough sensitivity to reach the legal limits established for these pollutants in the matrices selected. The limits of detection achieved for 10mL of water ranged between 2.8ng/L (indeno(1,2,3-cd)pyrene) and 11.5ng/L (acenaphthene) with acceptable precision (between 4.5 and 18.2% RSD). The method was applied to the determination of the selected PAHs in tap, river waters and sewage, being fluoranthene and pyrene detected in all of them at concentrations lower than the legal limits established for these compounds in the matrices assayed.  相似文献   

13.
A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor of 16.5 with on-line standard addition, and (103)Rh was used as internal standard to compensate for signal fluctuation. The procedure was validated by the analysis of two standard reference materials SRM 2670 (NIST) and Seronormtrade mark Trace Elements in Urine. Recovery experiments were performed by spiking the reference materials as well as artificial urine. The detection limits (mug l(-1)) were 0.12,0.96,0.30,0.09,0.45,0.08,0.09, and the precisions (RSD,%) were 2.6,2.3,3.0,3.7,3.7,4.9,2.8 for Cu, Zn, As, Pb, Se, Ni and Mo, respectively. The procedure was applied to the analysis of 41 human urine samples. No correlations between the concentrations of the elements were observed.  相似文献   

14.
A confirmatory method based on isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the low-level determination of residues of four nitrofuran veterinary drugs in meat, e.g., furazolidone, furaltadone, nitrofurantoin, and nitrofurazone. The procedure entails an acid-catalysed release of protein-bound metabolites, followed by their in situ conversion into the 2-nitrobenzaldehyde (NBA) imine-type derivatives. Liquid-liquid extraction and clean-up on a polymeric solid phase extraction cartridge are then performed before LC-MS/MS analysis by positive electrospray ionisation (ESI) applying multiple reaction monitoring of three transition reactions for each compound. Reliable quantitation is obtained by using one deuterated analogue per analyte (d4-NBA derivative) as internal standard (IS). Validation of the method in chicken meat was conducted following the European Union (EU) criteria for the analysis of veterinary drug residues in foods. The decision limits (CCalpha) were 0.11-0.21 microg/kg, and the detection capabilities (CCbeta) 0.19-0.36 microg/kg, thus below the minimum required performance limit (MRPL) set at 1 microg/kg by the EU. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.  相似文献   

15.
徐磊  夏宁 《分析测试学报》2011,30(5):558-561
建立了一种在线固相萃取/高效液相色谱测定水样中4种痕量邻苯二甲酸酯(邻苯二甲酸甲酯、邻苯二甲酸乙酯、邻苯二甲酸丁酯和邻苯二甲酸(2-乙基)己酯)的新方法.样品由外加泵注入一根固相萃取小柱上进行富集,再将富集柱切换至高效液相色谱系统中,将富集在固相萃取小柱的邻苯二甲酸酯洗脱至分析柱进行分析.在线固相萃取柱为IonPac(...  相似文献   

16.
Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C(18) (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L(-1) HCl in 0.5% MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C(18) monolithic column (25 mm × 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01% aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 μg L(-1) for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112% was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.  相似文献   

17.
A HPLC method with automated column switching was developed and validated for the determination of Ro 63-1908 in rat and cynomolgus monkey plasma. Human plasma was used for calibration and was also included in the validation process. Ro 63-1908 belongs to a class of neuroprotective N-methyl-D-aspartate (NMDA) receptor blockers which were in development for the treatment of stroke and traumatic brain injury. The method involves deproteinisation of plasma samples with ethanol and direct injection of the supernatant (1.4 ml) into the HPLC column-switching system. To prevent a breakthrough of the analyte and the internal standard on the precolumn (Purospher RP-18, 75x4 mm) due to the high ethanol content, the injection solution was diluted, on-line, using an additional pump and a T-piece. 1% ammonium acetate-ethanol (100:2, v/v) was used as mobile phase for injection, as well as for on-line dilution, resulting in pre-concentration of the analyte and the internal standard on the precolumn. As Purospher RP-18 is a non-endcapped stationary phase with a special selectivity for amines, the analyte and the internal standard could then be selectively eluted with 30% acetonitrile (without any buffer in the mobile phase) and transferred to the analytical column [consisting of two coupled columns (125+250x4 mm) packed with Superspher 60 RP-select B], where they were separated by gradient elution and detected by fluorescence detection. Compared to the use of a 125 mm long precolumn and dilution of the supernatant with ammonium acetate prior to injection, the 75 mm precolumn and the on-line dilution procedure allowed about one third shorter run times (21 min) and, therefore, a higher sample throughput. The limit of quantification was 1 ng/ml using 0.4 ml plasma. The method was applied to more than 670 plasma samples from pharmacokinetic and toxicokinetic studies and is also suitable for other matrices and NMDA receptor blockers.  相似文献   

18.
建立了GC-MS/FID测定环境空气中57种臭氧前体物的分析方法.优化三级冷阱捕集温度、三级冷阱解析温度、初始柱温、毛细管色谱柱等实验条件.优化条件为:采用硅烷化的苏玛罐采集环境空气,目标组分经三级冷阱在-180℃低温浓缩富集,80℃解析,初始柱温为15℃,结合中心切割技术,将乙烷、乙烯、乙炔、丙烷、丙烯切割至TG-B...  相似文献   

19.
基于酸性条件下甲醛对尿酸-KMnO4发光反应的增敏作用,建立了在线稀释顺序注射化学发光联用技术测定人体液中尿酸的新方法。在选定的实验条件下的7个浓度梯度范围内,尿酸浓度在5.0×10-6mol/L~1.0×10-3mol/L范围内与发光强度呈良好线性关系,相关系数0.9942~0.9998,RSD在2.0%~3.5%之间,回收率为98.0%~103.0%。每小时可分析80个样品,在线稀释测定结果与手工稀释法一致。  相似文献   

20.
建立了牛奶中8类禁用药物的液相色谱-串联质谱( LC- MS/MS)检测方法.分析物包括5种硝基咪唑、7种β-受体激动剂、9种雄性激素、7种糖皮质激素、3种雌性激素、2种镇静剂、1种氯霉素以及6种二羟基苯甲酸内酯共40种禁用药物.样品以β葡萄糖苷醛酶/芳基硫酸酯酶在乙酸铵缓冲液中酶解,用氨化和酸化乙腈各提取一次.提取液经改良的分散固相萃取(QuEChERS)净化,浓缩后采用C18色谱柱分离(150 mm×2.1 mm i.d.,3.0 um).以甲醇和水(含0.1%甲酸)、乙腈和水分别作为正、负电喷雾离子化模式的色谱分离流动相进行梯度洗脱,多反应监测模式进行定性和定量分析.7种药物以内标法定量;33种药物以基质标准曲线外标法定量,氯霉素在0.02~0.4μg/kg; 39种药物在0.20~ 10.0 μg/kg范围内相关系数(r)均大于0.99;定量限(S/N=10)在0.07~0.93 μg/kg之间.分别以各个药物0.5,1和2倍MRPL( Minimum required performance limits)浓度水平加标验证实验,回收率范围60.3%~119.3%范围;相对标准偏差小于18.9%.  相似文献   