首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
Pyrolysis gas chromatography–mass spectrometry (PyGC-MS) was used as a rapid method for the characterization of permanent marker ink. Twenty-four samples of various colours purchased from different manufacturers were characterised. Four main typologies of polymer-binding medium could be distinguished on the basis of the pyrolysis products, and differentiation between permanent markers of different manufacturers could be accomplished. For some permanent marker samples, PyGC-MS analysis allowed pigment identification as well.  相似文献   

2.
Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography–ESI-mass spectrometry (LC–ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20–6 ng injected), quantitation (excellent linearity; <2% relative standard deviation), and recovery (99–103%). The major and minor capsaicinoids in a commercial plant extract and in chili pepper fruits were quantified.Electronic Supplementary Material Supplementary material is available for this article at  相似文献   

3.
The characterization of unknown impurities present in tobramycin by liquid chromatography (LC) coupled with mass spectrometry (MS) is described. A reversed-phase (RP)-LC method using a volatile mobile phase containing a perfluorinated ion-pair reagent was developed and coupled with an ion trap mass spectrometer. The structures of the unknown impurities were deduced by comparison of their fragmentation patterns with those of the available reference substances obtained by LC–MSn experiments.  相似文献   

4.
During the European Union project Quantification of Aerosol Nucleation in the European Boundary Layer (QUEST), which began in spring 2003, atmospheric aerosol particles were collected in a Finnish Scots pine forest using a high-volume sampler. The organic compounds in the filter samples were then analysed by on-line coupled supercritical fluid extraction–liquid chromatography–gas chromatography–mass spectrometry (SFE–LC–GC–MS). The sample was first extracted by SFE. During LC the extracts were fractionated into three fractions according to polarity. The final separation was carried out by GC–MS. A fraction volume as high as 840 L was transferred to the GC, using the partial concurrent eluent evaporation technique. The same instrumentation, with an in-situ SFE derivatisation method, was used to analyse organic acids. Major compounds such as n-alkanes and PAH were analysed quantitatively. Their concentrations were lower than those usually observed in urban areas or in other forest areas in Europe. The wind direction was one of the most important factors affecting changes in the daily concentrations of these compounds. Scots pine needles were analysed with the same system to obtain reference data for identification of biogenic compounds in aerosol particles. Other organic compounds found in this study included hopanes, steranes, n-alkanals, n-alkan-2-ones, oxy-PAH, and alkyl-PAH; some biogenic products, including oxidation products of monoterpenes, were also identified.  相似文献   

5.
We present a fast liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the analysis of the coccidiostat amprolium in food samples. Tandem mass spectrometry in a triple quadrupole was used for quantitative purposes, and the information from multiple-stage mass spectrometry in an ion-trap mass analyzer contributed to fragmentation studies. Hydrophilic interaction liquid chromatography (HILIC) in a Fused-Core™ column using isocratic elution (acetonitrile:formic acid/ammonium formate buffer pH 4, 50 mM (60:40)) successfully analyzed this compound in less than 3 min. The HILIC system was coupled to heated electrospray-MS/MS using highly selective-selected reaction monitoring (H-SRM) to improve sensitivity and selectivity for the analysis of amprolium, after a simple sample treatment based on an “extract and shoot” strategy. Accurate mass measurements were performed to identify the interfering compound responsible for causing matrix ion enhancement in the signal of amprolium. The addition of l-carnitine (the interfering compound) (1 μg L−1) to standards and sample extracts allowed the use of the external calibration method for quantitative purposes. The LC–MS/MS (H-SRM) method showed good precision (relative standard deviation, RSD, lower than 13%), accuracy and linearity and allowed the determination of amprolium down to the ppb level (LODs between 0.1 and 0.6 μg kg−1).  相似文献   

6.
Structural analysis of complex mixtures of oligosaccharides using tandem mass spectrometry is regularly complicated by the presence of a multitude of structural isomers. Detailed structural analysis is, therefore, often achieved by combining oligosaccharide separation by HPLC with online electrospray ionization and mass spectrometric detection. A very popular and promising method for analysis of oligosaccharides, which is covered by this review, is graphitized carbon HPLC–ESI-MS. The oligosaccharides may be applied in native or reduced form, after labeling with a fluorescent tag, or in the permethylated form. Elution can be accomplished by aqueous organic solvent mixtures containing low concentrations of acids or volatile buffers; this enables online ESI-MS analysis in positive-ion or negative-ion mode. Importantly, graphitized carbon HPLC is often able to resolve many glycan isomers, which may then be analyzed individually by tandem mass spectrometry for structure elucidation. While graphitized carbon HPLC–MS for glycan analysis is still only applied by a limited number of groups, more users are expected to apply this method when databases which support structural assignment become available.
Manfred WuhrerEmail:
  相似文献   

7.
Investigation of acetylspiramycin (ASPM) and its related substances was carried out using a reversed-phase liquid chromatography/tandem mass spectrometry method. The identification of impurities in the ASPM complex was performed with a quadrupole ion trap mass spectrometer, with an electrospray ionization (ESI) source in the positive ion mode which provides MSn capability. A total of 83 compounds were characterized in commercial samples, among which 31 impurities that had never been reported and 31 partially characterized impurities were deduced using the collision-induced dissociation (CID) spectra of major ASPM components as templates. Most of the major impurities arise from the starting materials and the synthesis process. This work provides very useful information for quality control of ASPM and evaluation of its synthesis process.  相似文献   

8.
Presumable structures of polyethanolamines, synthesized by the catalytic β-hydroxyethylation of ammonia with an excess of ethylene oxide are determined by gas chromatography–electron ionization mass spectrometry and tandem mass spectrometry qualitatively, following fragmentation ways and also taking into account retention data. The preferable paths of consecutive reactions of the synthesis of polyethanolamines in a homologous series of isomers are found.  相似文献   

9.
A novel, specific and sensitive non-immunological liquid chromatography–mass spectrometry (LC–MS) based assay has been developed to detect and quantify trace levels of wheat gluten in food and consumer products. Detection and quantification of dietary gluten is important, because gluten is a principle trigger of a variety of immune diseases including food allergies and intolerances. One such disease, celiac sprue, can cause intestinal inflammation and enteropathy in patients who are exposed to dietary gluten. At present, immunochemistry is the leading analytical method for gluten detection in food. Consequently, enzyme-linked immunosorbent assays (ELISAs), such as the sandwich or competitive type assays, are the only commercially available methods to ensure that food and consumer products are accurately labeled as gluten-free. The availability of a comprehensive, fast and economic alternative to the immunological ELISA may also facilitate research towards the development of new drugs, therapies and food processing technologies to aid patients with gluten intolerances and for gluten-free labeling and certification purposes. LC–MS is an effective and efficient analytical technique for the study of cereal grain proteins and to quantify trace levels of targeted dietary gluten peptides in complex matrices. Initial efforts in this area afforded the unambiguous identification and structural characterization of six unique physiologically relevant wheat gluten peptides. This paper describes the development and optimization of an LC–MS/MS method that attempts to provide the best possible accuracy and sensitivity for the quantitative detection of trace levels of these six peptides in various food and consumer products. The overall performance of this method was evaluated using native cereal grains. Experimental results demonstrated that this method is capable of detecting and quantifying select target peptides in food over a range from 10 pg/mg to 100 ng/mg (corresponding to approximately 0.01–100 ppm). Limits of detection (LOD) and quantification (LOQ) for the six target peptides were determined to range from 1 to 30 pg/mg and 10–100 pg/mg respectively. Reproducibility of the assay was demonstrated by evaluation of calibration data as well as data collected from the analysis of quality control standards over a period of four consecutive days. The average coefficient of determination (R2) for each peptide was consistently found to be >0.995 with residuals ranging from approximately 80% to 110%. Spike recovery data for each peptide in various matrices was evaluated at a concentration level near the approximate LOQ for each, as well as at higher concentration levels (30 and 60 ng/mg). The average range of accuracy of detection for all peptides at the lower concentration level was determined to be 90% (±11), while accuracy at the 30 and 60 ng/mg levels was 98% (±5%) and 98% (±3%), respectively. The usefulness and capabilities of this method are presented in a practical application to prospectively screen a variety of common commercially available (native and processed) gluten-containing and gluten-free foods and products.  相似文献   

10.
This work describes a liquid chromatography–electrospray tandem mass spectrometry method for detection of desmopressin in human plasma in the low femtomolar range. Desmopressin is a synthetic analogue of the antidiuretic hormone arginine vasopressin and it might be used by athletes as a masking agent in the framework of blood passport controls. Therefore, it was recently added by the World Anti-Doping Agency to the list of prohibited substances in sport as a masking agent. Mass spectrometry characterization of desmopressin was performed with a high-resolution Orbitrap-based mass spectrometer. Detection of the peptide in the biological matrix was achieved using a triple-quadrupole instrument with an electrospray ionization interface after protein precipitation, weak cation solid-phase extraction and high performance liquid chromatography separation with an octadecyl reverse-phase column. Identification of desmopressin was performed using three product ions, m/z 328.0, m/z 120.0, and m/z 214.0, from the parent ion, m/z 535.5. The extraction efficiency of the method at the limit of detection was estimated as 40% (n = 10), the ion suppression as 5% (n = 10), and the limit of detection was 50 pg/ml (signal-to-noise ratio greater than 3). The selectivity of the method was verified against several endogenous and synthetic desmopressin-related peptides. The performance and the applicability of the method were tested by analysis of clinical samples after administration of desmopressin via intravenous, oral, and intranasal routes. Only after intravenous administration could desmopressin be successfully detected.  相似文献   

11.
Reversed-phase liquid chromatography on the nanoscale coupled to electrospray tandem mass spectrometry was used to analyse a mixture of four commercial glycan standards, and the method was further adapted to N-glycans enzymatically released from alpha-1-acid glycoprotein and immunoglobulin gamma. Glycans were permethylated to enable their separation by reversed-phase chromatography and to facilitate interpretation of fragmentation data. Prior to derivatization of glycans by permethylation, they were reduced to cancel anomerism because, although feasible, it was not desired to separate α- and β-anomers. The effect of supplementing chromatographic solvent with sodium hydroxide to guide adduct formation was investigated. Raising the temperature in which the separation was performed improved chromatographic resolution and affected retention times as expected. It was shown by using the tetrasaccharides sialyl Lewis X and sialyl Lewis A that reversed-phase chromatography could achieve the separation of methylated isobaric glycan analytes. Isobaric glycans were detected among the N-glycans of immunoglobulin gamma and further analysed by tandem mass spectrometry.  相似文献   

12.
An archaeological artifact, representing a compound piece of the Bronze Age, the outer surface of which is encrusted with seeds, has been investigated. The chemical composition of the organic binder was determined by gas chromatography and mass spectrometry; X-ray fluorescence analysis was used to determine the nature of the inorganic base of the artifact.  相似文献   

13.
The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50–300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10–150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples.  相似文献   

14.
15.
A method for the identification and quantification of underivatised steryl sulphates in invertebrates by liquid chromatography (LC) coupled with tandem mass spectrometry (MS) involving a single cleanup step has been developed. Negative electrospray ionisation and positive and negative atmospheric-pressure chemical ionisation (APCI) spectra of steryl sulphate showed pseudomolecular ions ([M+H–H2SO4]+or [M–H]). Collision-induced dissociation (CID) was efficient only in positive APCI. LC-MS in negative APCI was least susceptible to interference and possible differences in response factors. The detection limits (signal-to-noise ratio of 3) based on cholest-5-enyl-3-sulphate in positive and negative APCI modes are 3.66 and 0.73 pmol μL−1, respectively. Calibration plots and response factors for cholest-5-enyl-3-sulphate relative to the internal standard, cholecalciferyl-3-sulphate, in both positive and negative polarities, were linear in the concentration range from 1.22 to 16.4 pmol μL−1 with good coefficients of determination (R 2>0.98). It is suggested that the structure elucidation of steryl sulphates is best achieved in CID positive APCI mode, whereas their quantification should be carried out using negative APCI.  相似文献   

16.
The time-honored convention of concentrating aqueous samples by solid-phase extraction (SPE) is being challenged by the increasingly widespread use of large-volume injection (LVI) liquid chromatography–mass spectrometry (LC–MS) for the determination of traces of polar organic contaminants in environmental samples. Although different LVI approaches have been proposed over the last 40 years, the simplest and most popular way of performing LVI is known as single-column LVI (SC-LVI), in which a large-volume of an aqueous sample is directly injected into an analytical column. For the purposes of this critical review, LVI is defined as an injected sample volume that is ≥10% of the void volume of the analytical column. Compared with other techniques, SC-LVI is easier to set up, because it requires only small hardware modifications to existing autosamplers and, thus, it will be the main focus of this review. Although not new, SC-LVI is gaining acceptance and the approach is emerging as a technique that will render SPE nearly obsolete for many environmental applications. In this review, we discuss: the history and development of various forms of LVI; the critical factors that must be considered when creating and optimizing SC-LVI methods; and typical applications that demonstrate the range of environmental matrices to which LVI is applicable, for example drinking water, groundwater, and surface water including seawater and wastewater. Furthermore, we indicate direction and areas that must be addressed to fully delineate the limits of SC-LVI.  相似文献   

17.
18.
A sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of 13 steroidal anti-inflammatory drugs in bovine milk is presented. Due to their weakly acid nature, analytes were separated by ion suppression reversed phase chromatography and detected in positive-ion mode by a high flow electrospray source. Dexamethasone-d4 was used as internal standard. The sample preparation was simple and reliable; it included acidic deproteinization of milk followed by sample enrichment and clean-up, utilizing a C18 solid phase extraction cartridge. Recoveries exceeded 70% with an intra-day precision not larger than 12%. The efficiency of the sample clean-up and internal standardization rendered negligible the matrix effect, estimated by comparing standard and matrix-matched calibration curves. A small-scale reconnaissance was carried out on several raw and whole fresh milk samples. A large number of analyzed samples showed a chromatographic peak, in the retention time window of cortisol, at levels included between its decision limit (CCα) and detection capability (CCβ). As a result of a heat-induced transformation, an isomeric product of triamcinolone was observed during the extract evaporation. Since this rearrangement might occur during the milk pasteurization process, LC-MS/MS and 1H-NMR investigations were performed out to conclusively differentiate the two isomers. One- and two-dimensional proton NMR spectra were able to identify the transformation product as 9a-fluoro-11b,16a-trihydroxy-17b-hydroxymethyl-D-homoandrosta-1,4-diene-3,17a-dione.  相似文献   

19.
Pteridines are a diverse family of endogenous metabolites that may serve as useful diagnostic biomarkers for disease. While many preparative and analytical techniques have been described for analysis of selected pteridines in biological fluids, broad intracellular pteridine detection remains a significant analytical challenge. In this study, a novel, specific and sensitive extraction and high performance liquid chromatography–quadrupole time-of-flight mass spectrometry (HPLC–QTOF MS) method was developed to simultaneously quantify seven intracellular pteridines and monitor 18 additional, naturally-occurring intracellular pteridines. The newly developed method was validated through evaluation of spiked recoveries (84.5–109.4%), reproducibility (2.1–5.4% RSD), method detection limits (0.1–3.0 μg L−1) and limits of quantitation (0.1–1 μg L−1), and finally application to non-small cell lung cancer A549 cells. Twenty-three pteridine derivatives were successfully detected from cell lysates with an average RSD of 12% among culture replicates. Quantified intracellular pteridine levels ranged from 1 to 1000 nM in good agreement with previous studies. Finally, this technique may be applied to cellular studies to generate new biological hypotheses concerning pteridine physiological and pathological functions as well as to discovery new pteridine-based biomarkers.  相似文献   

20.
A specific and sensitive multi-method based on liquid chromatography–tandem mass spectrometry using atmospheric pressure chemical ionization (LC–APCI–MS/MS) has been developed for the determination of 20 anabolic steroids in muscle tissue (diethylstilbestrol, β-estradiol, ethynylestradiol, α/β-boldenone, α/β-nortestosterone, methyltestosterone, β-trenbolone, triamcinolone acetonide, dexamethasone, flumethasone, α/β-zearalenol, α/β-zearalanol, zearalenone, melengestrol acetate, megestrol acetate and medroxyprogesterone acetate). The procedure involved hydrolysis, extraction with tert-butyl methyl ether, defattening and final clean-up with solid phase extraction (SPE) on Oasis HLB and Amino cartridges. The analytes were analyzed by reversed-phase LC–MS/MS, in positive and negative multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for the unambiguous confirmation of the hormones. The method was validated at the validation level of 0.5 ng/g. The accuracy and precision of the method were satisfactory. The decision limits CCα ranged from 0.03 to 0.14 ng/g while the detection capabilities CCβ ranged from 0.05 to 0.24 ng/g. The developed method is sensitive and useful for detection, quantification and confirmation of these anabolic steroids in muscle tissue and can be used for residue control programs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号