首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A new method of separation and identification of aromatic and nitrogen-containing acids is presented. Fifty-seven different acid standards were separated by reversed-phase high performance liquid chromatography (HPLC). Detection and identification of the acids by ultraviolet (UV) spectra using a photodiode array detector (DAD) is demonstrated. Peak height ratios are reported and complete UV spectra of these acids are displayed. Possible applications of this technique are demonstrated using patients' urines.  相似文献   

2.
A multiresidue HPLC method for identification and quantification of the synthetic acaricides fluvalinate, coumaphos, bromopropylate and its metabolite 4,4′-dibromobenzophenone in beeswax has been developed. Different techniques were tested and modified. The method consists of a sample preparation with isooctane followed by solid phase extraction using Florisil columns. Determination of the synthetic acaricides is achieved by HPLC with a photodiode array detector. Analytical performance of the proposed method, including sensitivity, accuracy and precision was satisfactory. The LOD for the analytes varied between 0.1 and 0.2 μg g−1 wax and the recoveries between 70 and 110%. Relative standard deviation of the repeatability of the method is <15% and reproducibility is <31%.  相似文献   

3.
4.
5.
Amoxicillin, amoxicilloates, amoxicillin oligomers and amoxicillin piperazine-2,5-dione are separated by reversed-phase (C8) high-performance liquid chromatography with gradient elution. Quantitative results are reported for a number of samples. Amoxicillin trihydrate samples mostly contain amoxicilloate as the main impurity. Samples of the sodium salt also contain the piperazine-2,5-dione and the dimer. Higher oligomers such as the trimer and tetramer were not present in significant amounts. Several samples were also analysed by a mercurimetric titration method.  相似文献   

6.
A high sensitivity, multichannel fluorescence detector with small volume has been developed for capillary column liquid chromatography. Using an intensified linear photodiode array to monitor fluorescence emission, several important mixtures exhibiting native fluorescence have been examined following high efficiency separation on a capillary column. By correlating mass spectral, fluorescence spectral, and retention time data, information of potential utility in the structural elucidation of aromatic molecules contained in complex mixtures can be obtained. Examples include the separation and spectral examination of the polyaromatic compounds in samples of both biological and environmental interest.  相似文献   

7.
For the determination of beta-aminoisobutyric acid (BAIBA) in urine samples in which the beta-alanine concentrations are higher than those of BAIBA, the resolution between these two amino acids, separated by reversed-phase liquid chromatography on an octadecylsilane column, was optimized. The chromatographic analysis included precolumn derivatization of amino acids with o-phthalaldehyde, followed by a 15-min isocratic elution and detection at 340 nm. Because of its simplicity, this method should be useful for monitoring urinary excretion of BAIBA.  相似文献   

8.
9.
10.
建立了护发产品中肌酸的高效液相色谱(HPLC)测定方法.样品经流动相溶解并提取,采用偏磷酸溶液为流动相,流速为1.0 mL/min,以C8色谱柱(250 mm×4.6 mm 5μm)进行分离,二极管阵列检测器进行检测,检测波长为210 nm.在上述条件下,目标物质与样品的杂质获得有效分离,在2~100 mg/L范围内,质量浓度与峰面积呈良好的线性关系.对护发产品进行添加回收,回收率为92.5%~101.6%,RSD为2.0%~3.7%.已用于护发产品中肌酸含量的分析.  相似文献   

11.
Ex vivo placental perfusion experiments are important in understanding the quantity and mechanisms of xenobiotic transport to the fetus during pregnancy. Our study demonstrates that paclitaxel and antipyrine concentrations in placental perfusion medium containing physiological concentrations of human serum albumin during pregnancy (30?mg/mL) can be quantified by RP-HPLC and UV detection. A liquid-liquid extraction method was developed for the quantification of paclitaxel and celecoxib (internal standard) from perfusion medium. Antipyrine, which is a necessary marker in placental perfusions for determining the validity of experiments and calculating the clearance index of xenobiotics, was also analyzed by HPLC and UV detection. Antipyrine concentrations were determined by HPLC after precipitating the perfusion medium in acetonitrile and separating the precipitated proteins by centrifugation. Concentrations were fitted to linear regressions with R2 values approaching 1. Lower limits of detection for paclitaxel and antipyrine were 100?ng/mL and 200?ng/mL, respectively. Both methods demonstrated high intra-day and inter-day precision and trueness. Additionally, the use of these methods was demonstrated in a placental perfusion experiment using Taxol® (paclitaxel dissolved in Cremophor-EL). The fetal transfer rate of Taxol was 6.6% after 1 hour.  相似文献   

12.
A method to identify and quantitate clofibric acid and clofibroyl coenzyme A (CoA) products in rat liver was developed using reversed-phase high-performance liquid chromatography. The system was developed with baseline separation of clofibroyl-CoA from clofibric acid using isocratic elution, with a mobile phase consisting of 52% methanol and 28 mM potassium phosphate buffer (pH 4.2). With this high methanol concentration, the large amount of UV-absorbing materials present in the liver extracts were eluted earlier than the investigated compounds. Clofibroyl-CoA has a characteristic absorbance spectrum with distinct peaks at 260 and 230 nm, while clofibric acid showed only a distinct peak at 230 nm. Using an on-line photodiode array detector, the spectra could be recorded during analysis without interrupting the flow of the mobile phase. This spectral analysis identification possibilities and evaluation of the purity of the chromatographic peaks. In a perchloric extract of rat liver, the recovery of clofibric acid and clofibroyl-CoA added to the liver extract ranged from 70 to 80%. A linear relationship was observed between clofibric acid and clofibroyl-CoA concentration and the area of their peaks in the chromatogram. The detection limit of the method was lower than 5 pmol for both compounds when the absorbance was recorded at 230 nm. The method could be used without modification for the estimation of clofibroyl-CoA and clofibric acid in biological extracts.  相似文献   

13.
A reversed-phase LC method, optimised for the separation of trans- and cis-resveratrol, catechin, epicatechin, quercetin and rutin, is reported. Analyses were performed on a reversed-phase column by gradient elution. Detection was carried out by photodiode array, although the use of a fluorimetric detector considerably lowered the detection limits for catechin, epicatechin and both resveratrol isomers. Identification by the two different detection systems was based on retention characteristics, UV spectra and peak purity index were compared with commercial standards. The procedures were applied to the determination of the phenolic compounds in different types of wines and musts.  相似文献   

14.
An efficient and accurate analytical method was developed for the simultaneous determination of 20 synthetic food additives, including three sweeteners,seven food colorants,nine synthetic preservatives and caffeine,by high performance liquid chromatography (HPLC) with photodiode array detector(PDA).This method permits the detection of food additives at very low concentrations(0.005-0.150μg/mL).The applicability was verified by the determination of food additives present in various foodstuffs.  相似文献   

15.
The separation and determination of atracurium besylate and its major decomposition products and related impurities using octadecylsilica columns and acetonitrile-phosphate buffer mobile phases were studied. The influence of the acetonitrile and buffer concentrations and the pH of the mobile phase on the retention was investigated. The results indicated that hydrophobic and silanophilic interactions contribute to the retention of the compounds investigated.  相似文献   

16.
17.
18.
A rapid and sensitive high-performance liquid chromatographic technique was developed for the simultaneous determination of gentisic acid, salicyluric acid, acetylsalicylic acid and salicylic acid in plasma and serum. The method involved a single deproteinization step and separation using a reversed-phase column eluted with a buffered methanol (35%) mobile phase. Detection was achieved with a variable-wavelength ultraviolet detector set at 235 nm and a given chromatographic analysis could be completed in less than 10 min. The method was tested in both human and animal (rat) models given a single dose of acetylsalicylic acid.  相似文献   

19.
Chromatographic analyses play an important role in the identification and determination of phase I and phase II drug metabolites. While the chemical standards of phase I metabolites are usually available from commercial sources or by various synthetic, degradation or isolation methods, the phase II drug metabolites have usually more complicated structures, their standards are in general inaccessible and their identification and determination require a comprehensive analytical approach involving the use of xenobiochemical methods and the employment of hyphenated analytical techniques. In this work, various high-performance liquid chromatography (HPLC) methods were employed in the evaluation of xenobiochemical experiments leading to the identification and determination of phase II nabumetone metabolites. Optimal conditions for the quantitative enzymatic deconjugation of phase II metabolites were found for the samples of minipig bile, small intestine contents and urine. Comparative HPLC analyses of the samples of above-mentioned biomatrices and of the same biomatrices after their enzymatic treatment using beta-glucuronidase and arylsulfatase afforded the qualitative and quantitative information about phase II nabumetone metabolites. Hereby, three principal phase II nabumetone metabolites (ether glucuronides) were discovered in minipig's body fluids and their structures were confirmed using liquid chromatography (LC)-electrospray ionization mass spectrometric (MS) analyses.  相似文献   

20.
Methodology based on the cloud-point phenomenon was applied to the comparative study of 3 different polyoxyethylene nonionic surfactants in order to extract and preconcentrate a group of phenolic derivatives in water samples; these phenolic compounds, which were determined by liquid chromatography with UV detection, included 11 pollutants given priority by the U.S. Environmental Protection Agency. The optimum conditions for the extraction and preconcentration of phenolic compounds were established for each surfactant. The surfactant that gave the best extraction and preconcentration of the analytes under study was polyoxyethylene 6 lauryl ether (C12E6) with detection limits of <3.5 microg/L for all the phenolic compounds tested. The method was applied to seawater and depurated wastewater samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号