首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
High-performance liquid chromatography (HPLC) with UV detection for the simultaneous determination of the free form of p-hydroxymethamphetamine (p-OHMA) and its metabolite, glucuronide (p-OHMAG) was accomplished for the first time. We achieved this by employing 1) an ion pair reagent for retention of sample to a solid-phase extraction (SPE) cartridge, Sep-Pak Light C18 and 2) a simple two-step stepwise elution technique for subsequent ion pair RP-HPLC. The proposed method was optimized for resolution of p-OHMAG, p-OHMA and MA. The method was successfully applied to urine samples collected from MA abusers.  相似文献   

2.
3.
We describe a rapid and sensitive high-performance liquid chromatography/electrospray tandem mass spectrometry (HPLC/ESI-MS/MS) method for simultaneous determination of the most relevant metabolites of benzene and toluene, t,t-muconic acid (t,t-MA), S-phenylmercapturic acid (S-PMA), and S-benzylmercapturic acid (S-BMA). Urine samples were purified before analysis by solid-phase microextraction (SPE) on SAX cartridges with 50 mg sorbent mass. The developed method fulfils all the standard requirements of precision and accuracy. Calibration curves were linear within the concentration range of the standards (0-80 microg/L(urine) for t,t-MA, and 0-25 microg/L(urine) for S-PMA and S-BMA), and had correlation coefficients > or =0.997. Limits of detection were 6.0 microg/L for t,t-MA, 0.3 microg/L for S-PMA, and 0.4 microg/L for S-BMA. The method was used to determine t,t-MA, S-PMA and S-BMA levels in urine of 31 gasoline-station workers, with personal monitoring data obtained from radial symmetry passive diffusive samplers. In the context of mean work-shift exposures of 75.9 microg/m(3) (range 9.4-220.2) for benzene and 331.9 microg/m(3) (78.2-932.1) for toluene, metabolite concentrations in end-of-shift urine samples ranged from 23.5-275.3 microg/g(creatinine) for t,t-MA, non-detectable to 0.9 microg/g(creatinine) for S-PMA, and 3.8-74.8 microg/g(creatinine) for S-BMA. No significant correlation was found between the environmental concentrations and urinary metabolites (p > 0.05 for all cases); the ratios of benzene metabolites could be influenced by exposure levels and co-exposure to xylenes and toluene. The high throughput of this procedure should facilitate exploration of the metabolic effects of benzene-related co-exposure to toluene and alkylbenzenes in large populations of subjects exposed to gasoline.  相似文献   

4.
A novel and rapid procedure based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of dialkyl phosphates (metabolites of organophosphorus pesticides) in human urine has been developed. After addition of 40 mM tetrabutylammonium acetate, 10 microL of urine sample were directly injected into the LC/MS/MS system. The method was validated yielding calibration curves with correlation coefficients greater than 0.997 and repeatability coefficient of variation (CV) lower than 9%. The accuracy and precision were evaluated by direct injection of spiked samples at 10 and 100 microg/L obtaining recoveries between 78 and 119% with coefficients of variation below 12%. Limits of detection of 1 microg/L for diethyl phosphate (DEP), diethylthiophosphate (DETP) and diethyldithiophosphate (DEDTP) and 2 microg/L for dimethyldithiophosphate (DMDTP) were achieved, all the analytes being detected in negative ion mode. The fragmentation pathway of dialkyl phosphates allowed us the use of an additional transition for confirmation in order to improve their identification in real-world samples. The applicability of the LC/MS/MS method was demonstrated by applying it to the analysis of urine samples of farmers exposed to the organophosphorus pesticide chlorpyrifos. Good correlation between application of the product in the field (citrus orchards), concentration levels of dialkyl phosphates and levels of the chlorpyrifos-specific metabolite (1,3,5-trichloro-2-pyridinol) was obtained.  相似文献   

5.
A reversed-phase HPLC method for the determination of epinephrine, norepinephrine, dopamine, and vanillylmandelic acid (VMA) has been developed. The concentration of VMA in the urine of hypertensive patients was measured by direct injection after centrifugation. The method is useful for the diagnosis of pheochromocytoma.  相似文献   

6.
7.
A novel and robust two-dimensional liquid chromatography with ultraviolet detection method (2D-LC–UV) was developed and validated for high-throughput determination of the concentrations of valproic acid (VPA) in human plasma. This 2D-LC system was composed of a first-dimensional LC column, a second-dimensional LC column and an intermediate transfer column. The sample was directly injected into the 2D-LC system after an easy protein precipitation treatment. After online preconcentration and primary separation by the first-dimensional column, the target was captured by an intermediate column and then transferred to second-dimensional column for analysis. The system transferred the target through “central cutting” mode whereby the drug peak was not subject to interference from the matrix. The analysis cycle time was completed within 7.0 min. Compared with other methods that have been developed, the analysis time was reduced and the operation was much easier without any derivatization. The calibration curve was linear over the 5.90–188.94 μg/ml range for the VPA concentrations. The intra-day and inter-day precisions were <5.6%. The recoveries were in the range from 95.2 to 98.0%. This method appears to be sensitive, precise, rapid and low-cost for the quantification of VPA in serum sample.  相似文献   

8.
The improvement of high-performance liquid chromatographic analysis with electrochemical detection for urinary homovanillic acid is described. The method permits the chromatographic resolution of authentic homovanillic acid from coeluting interfering compounds in human and nonhuman primate, and rat urine. The electrochemically derived results are compared with post-column derivatized fluorescence results, and quality-control checks necessary to maintain assay precision in automated analysis are described.  相似文献   

9.
10.
A highly sensitive and simple method for determining delta-aminolevulinic acid (ALA) in urine was established, using direct injection of urine into a high-performance liquid chromatographic column, with fluorometric detection after post-column derivatization with o-phthalaldehyde (OPA). The recovery of ALA was about 100% and ALA was completely separated on an ion exchange column (retention time, 38 min). The detection limit for ALA was 10 pmol (S/N = 2). The mean levels of urinary ALA of 10 healthy volunteers, 4 patients with acute intermittent porphyria, and 2 workers occupationally exposed to lead were 0.76, 5.25, and 23.54 mg/l, respectively. Because of its simplicity, the method is considered to be suitable for routine analysis of urinary ALA in the clinical laboratory.  相似文献   

11.
A high performance liquid chromatographic (HPLC) system is described for determination of the unsaturated disaccharide (delta Di-HA) derived from hyaluronic acid (HA) in human urine by digestion with hyaluronidase SD. The effects of eluents on the separation of delta Di-HA and delta Di-0S, which is derived from the reaction of chondroitin with the enzyme, have been studied. The established chromatographic conditions were as follows--column: a stainless steel tube (4 mm i.d. x 250 mm) packed with TSKgel NH2-60; eluent: a mixture of acetonitrile and 0.1 M Tris-HCl buffer containing 0.1 M boric acid and 10 mM sodium sulphate, pH 7.0 (64:36, v/v). The strong fluorescence of unsaturated disaccharide after the reaction with 2-cyanoacetamide in alkaline medium was used for post-column detection. The calibration curve for delta Di-HA was linear in the range 5 pmol-5nmol with a practical detection limit of 2 pmol. The assay coefficients of variation (n = 5) at 200 pmol for delta Di-HA and delta Di-0S were 1.7 and 1.5%, respectively. This HPLC system has been applied to the determination of HA in human urine.  相似文献   

12.
A method is described for the determination of urinary hippuric acid by high-performance liquid chromatography. The method used ethyl acetate extraction for partial clean up of the urine. The separation was carried out on a reversed-phase column using 20% methanol in 0.01 M aqueous potassium phosphate containing 0.5% acetic acid as a mobile phase. The column effluent was monitored with a UV detector at 254 nm. Hippuric acid was separated from other normal urine constituents in less than 10 min. Metabolites of xylene and styrene did not interfere with the assay. Analytical recoveries from urine were excellent and peak height and concentration were linearly related.  相似文献   

13.
For the fluorimetric determination of isatin in human urine and serum, HPLC-postcolumn photoirradiation using a mobile phase has been developed. Isatin in the urine or serum sample was separated on a Capcell Pak C1 column (250 x 4.6 mm id). The mobile phase consisted of 70 mmol l-1 phosphate buffer (pH 7.2)-tetrahydrofuran (85 + 15% v/v) containing 5 mmol l-1 hydrogen peroxide, which was irradiated with germicidal light to induce fluorescence (lambda ex 302 nm, lambda em 418 nm). The addition of tetrahydrofuran to the mobile phase led to the peaks showing good separation as well as increased sensitivity. The calibration graph for isatin was linear over the range of 0.16-10.7 ng. The pretreatment of the acidified urine or serum samples consisted of diluting steps or deproteinizing steps using perchloric acid, respectively. The mean recovery of isatin from urine and serum was greater than 94%.  相似文献   

14.
Changes in free amino acids content and its potential racemization in ready-to-eat foods treated with E-beam irradiation between 1 and 8 kGy for sanitation purposes were studied. A simple heart cut two-dimensional high performance liquid chromatographic method (LC–LC) for the simultaneous enantiomeric determination of three pairs of amino acids used as markers (tyrosine, phenylalanine, and tryptophan) is presented. The proposed method involves the use of two chromatographs in an LC–LC achiral–chiral coupling. Amino acids and their decomposition products were firstly separated in a primary column (C18) using a mixture of ammonium acetate buffer (20 mM, pH 6) (94%) and methanol (6%) as the mobile phase. Then, a portion of each peak was transferred by heart cutting through a switching valve to a teicoplanin-chiral column. Methanol (90%)/water (10%) was used as the mobile phase. Ultraviolet detection was at 260 nm. Detection limits were between 0.16 and 3 mg L−1 for each enantiomer. Recoveries were in the range 79–98%. The LC–LC method combined with the proposed sample extraction procedure is suitable for complex samples; it involves an online cleanup, and it prevents degradation of protein, racemization of L-enantiomers, and degradation of tryptophan. Under these conditions, D-amino acids were not found in any of the analyzed samples at detection levels of the proposed method.  相似文献   

15.
A system for the determination of oxalic acid in human urine using ion exchange-ion pair, high performance liquid chromatography with electrochemical detection (HPLCEC) is described. Urine is acidified with HCl, and excess CaCl2 is added to precipitate oxalate ion. The precipitate is isolated, redissolved in dilute sulfuric acid, and separated on a strong cation exchange column using an acetic acid-solium acetate-tetrabutylammonium tetrafluoroborate mobile phase adjusted to pH 2.8. Using an electrochemical detector at 1.25 volts vs. the saturated calomel electrode (SCE), oxalic acid exhibits a linear dynamic range from 1 to 1000 mg/liter with a detection limit of 0.1 mg/liter. Quantitative data are obtained by the method of standard addition in the clinically significant range from 5 to 40 mg/liter. Percentage recovery for spiked urine samples was 97.8% with a relative standard deviation of 2.5%.  相似文献   

16.
Inulin and p-aminohippuric acid (PAH) clearances are used for the estimation of glomerular filtration rate (GFR) and effective renal plasma flow (ERPF). A simple and rapid high-performance liquid chromatography (HPLC) method with UV detection is described for the simultaneous determination of inulin and PAH in the same chromatogram in the plasma and urine of humans. Plasma and urine samples were hydrolyzed with perchloric acid (0.7%) in boiling water. The mobile phase consisted of 0.01 M potassium dihydrogenphosphate with 0.02 M tetramethylammonium chloride and o-phosphoric acid (pH 3)-acetonitrile (94:6, v/v), pumped at a rate of 1.2 ml min-1 on a C8 reversed-phase column. Tannic acid was used as the internal standard and UV detection at 285 nm was employed. The calibration curves were linear over the concentration range of 12.5-100 mg l-1 for inulin and 6.25-50 mg l-1 for PAH with determination coefficients greater than 0.997. The method is accurate (bias < 13%) and reproducible (intra- and inter-day relative standard deviation less than 11%), with a limit of quantitation of 12.5 mg l-1 and 6.25 mg l-1 for inulin and PAH, respectively. Analytical recoveries from urine and plasma were ranged from 81 to 108% for both compounds. This fully validated method, which allows the simultaneous determination of inulin and PAH clearances, is simple, rapid (total run time < 10 min) and requires only a 200 microliters plasma or urine sample.  相似文献   

17.
For patients with inborn errors of urea synthesis, oral administration of sodium benzoate is the usual treatment to increase the nitrogen excretion. Thus, monitoring hippuric acid and benzoic acid simultaneously in human biological fluids is considered to be clinically important. We developed a simple and accurate high-performance liquid chromatographic method for the simultaneous determination of hippuric acid and benzoic acid in human plasma and urine. This method requires no extraction step. Aliquots of urine and plasma are added to a solution of internal standard (o-chlorobenzoic acid) in acetonitrile and directly injected onto a reversed-phase column using an acidic (pH 2.7) eluent and ultraviolet detection at 235 nm. The preliminary plasma concentration-time and urinary excretion rate-time profiles of hippuric acid and benzoic acid from a healthy subject receiving small, medium and large doses of sodium benzoate are reported.  相似文献   

18.
19.
20.
A method is proposed for the detection and confirmation of the presence of beta-blockers and their metabolites in fivefold diluted human urine samples by ultra performance liquid chromatography coupled with electrospay ionization tandem mass spectrometry. The limits of detection for most of compounds are 5–10 ng/mL. A substantial effect of ionization suppression was observed. The determination of metabolites and glucuronides of beta-blockers without additional derivatization and extraction is described for the first time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号