首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Journal of Thermal Analysis and Calorimetry - In the present study, experiments on pool boiling heat transfer of graphene nanofluids on a flat heater surface (40 mm diameter) were...  相似文献   

2.

In the present work, a new simulation of nanofluid/vapor two-phase flow inside the 2-D rectangular boiling chamber was numerically investigated. The Eulerian–Eulerian approach used to predict the boiling curve and the interaction between two phases. The surface modification during pool boiling of silica nanofluid represented by surface roughness and wettability is put into the account in this simulation. New closure correlations regarding the nucleation sites density and bubble departure diameter during boiling of silica nanofluid were inserted to extend the boiling model in this work. Besides, the bubble waiting time coefficient which involved in quenching heat flux under heat flux partitioning HFP model was corrected to improve the results of this study. The numerical results validated with experimental works in the literature, and they revealed good agreements for both pure water and nanofluids. The results found that when improving the heat flux partitioning model HFP by considering the surface modification of nucleate pool boiling parameters, it will give more mechanistic sights compared to the classical model, which is used for predicting of boiling heat transfer of pure liquid.

  相似文献   

3.
《印度化学会志》2021,98(11):100200
For the first time, the heat transfer performance of a CuO–ZnO (80:20)/water hybrid has been studied experimentally and numerically in a shell and tube heat exchanger under turbulent flow conditions nanofluid (STHE). All experiments are carried out with 0.01 ​vol% CuO–ZnO (80:20)/water hybrid nanofluid at Reynolds numbers (NRe) ranging from 1900 to 17,500. The stabilized hybrid nanofluids (30 ​°C-Tube side) are then used as a coolant to reduce the hot fluid (60 ​°C-shell side) temperature using a STHE, with the results for the convective heat transfer coefficient, Nusselt number, friction factor, and pressure drop reported. The primary goal of this paper is to investigate the impact of hybrid nanoparticle mixing ratio optimization on STHE heat transfer efficiency under various operating conditions. According to the findings, the CuO–ZnO (80:20)/water hybrid nanofluid improved the heat transfer performance of the STHE at all Reynolds numbers. When using nanofluid over water, the Nusselt number and pressure drop were improved by approximately 33% and 13%, respectively. The hybrid nanofluid's maximum thermal performance factor and thermal efficiency enhancement were 1.45 and 7%, respectively, at NRe ​= ​17,500. According to the study, the thermal conductivity of nanofluid varies by only 5% after ten trials. Furthermore, the ANSYS Fluent program was used to predict the behavior of the hybrid nanofluid in STHE, and the simulation results fit the experimental values very well.  相似文献   

4.
A numerical simulation model for laminar flow of nanofluids in a pipe with constant heat flux at the wall has been built to study the effect of Reynolds number on heat transfer and pressure loss. The investigation was performed for metallic oxide and multi-oxide nanoparticles suspended in water. The thermal conductivity and dynamic viscosity were measured for a range of temperature (10–60 °C) and volume fraction of multi-oxide nanofluid. Comparison of the thermal conductivity for monocular oxide and multi-oxide nanofluids reveals a new way to control the enhancement in nanofluid conductivity. The numerical results obtained were compared with existing well-established correlations. The predictions of the Nusselt number for nanofluids are in agreement with the Shah correlation, and the deviation in the results is less than 1 %. It is found that the pressure loss increases with the Reynolds number, nanoparticle density, and volume fraction for multi-oxide nanoparticles. However, the flow demonstrates enhancement in heat transfer which improves with increasing Reynolds number of the flow.  相似文献   

5.

The heat transfer performance and entropy analysis are done in a compact loop heat pipe (CLHP) with Al2O3/water and Ag/water nanofluid. A compact loop heat pipe having a flat square evaporator with dimensions of 34 mm (L)?×?34 mm (W)?×?19 mm (H) has been fabricated and tested for the heat load ranging from 30 to 500 W. The experimental tests are conducted by keeping the CLHP in the vertical orientation with distilled water, silver (Ag)/water and aluminium oxide (Al2O3)/water nanofluid having low volume concentrations of (0.09% and 0.12%). The effect of wall and vapour temperature, evaporator and condenser heat transfer coefficient, thermal resistance on the applied heat loads is experimentally investigated and compared. The experimental results showed that the evaporator thermal resistance is reduced by 34.70% and 20.21%, respectively, for 0.12 vol% of Ag, Al2O3 nanoparticles when compared with that of the distilled water. For the same volume concentrations of Ag, Al2O3 nanoparticles, an enhancement of 34.52%, 23.7%, 39.27% and 30.8%, respectively, observed for the convective heat transfer coefficients at the evaporator and condenser. The entropy is also reduced by 19.08% and 11.58% when Ag and Al2O3 nanofluids are used as the operating fluid. From the experimental tests, it is found that the addition of small amount of Ag nanoparticles in the working fluid enhanced the operating range by 15% when compared with that of Al2O3/water nanofluid without the occurrence of any dry-out conditions.

  相似文献   

6.
The comparative study on the thermo-physical properties of water-based ZnO nanofluids and Ag/ZnO hybrid nanofluids is reported in the present study. The outer surface of ZnO nanoparticles was modified with a thin coating of Ag nanoparticles by a wet chemical method for improved stability and heat transfer properties. The ZnO and Ag/ZnO nanofluids were prepared with varying volume concentration (??=?0.02–0.1%). The synthesized nanoparticles and nanofluids were characterized with different characterization methods viz., scanning electron microscopy, X-ray diffraction, dynamic light scattering, thermal conductivity measurement, and viscosity measurement. Results show that thermal conductivity of Ag/ZnO hybrid nanofluids is found to be significantly higher compared to ZnO nanofluids. The maximum thermal conductivity an enhancement for Ag/ZnO nanofluid (??=?0.1%) is found to 20% and 28% when it compared with ZnO nanofluid (??=?0.1%) and water, respectively.  相似文献   

7.

Heat transfer enhancement and performance of compact heat exchangers have been extensively studied in the past century for the purpose of promoting energy efficiency. Microfin tubes in single/two/multiple-phase flow heat exchangers into which twisted tape swirl generators are installed can promote heat transfer with a moderate pressure loss penalty. This article reports on the enhanced heat transfer of silver–water nanofluids in a microfin tube into which loose-fit twisted tapes are installed in a counter-flow arrangement. The experiments were carried out using nanofluids with various silver concentrations (0.007–0.03 vol%), loose-fit twisted tapes with clearance ratios (c/D) of 0.0 (tight-fit), 0.05, 0.075 and 0.1, for a twist ratio, y/W, of 2.0. The results indicate that the heat transfer rate (Nu) and pressure drop (f) increase with a decrease in clearance ratio (c/D) and increase in silver (Ag) nanoparticle concentration. Additionally, the thermal performance factor tends to increase with the decrease in Reynolds numbers.

  相似文献   

8.

Nanofluid and coiled tubes have been employed as two passive methods for enhancing the heat transfer. In the present study, the turbulent flow of CuO–water nanofluid in helical and conical coiled tubes was numerically investigated with constant wall temperature through mixture model. The thermophysical properties of base fluid (water) were considered as temperature-dependent functions, while Brownian effects were adopted in thermal conductivity and dynamic viscosity of nanofluid. Simulation results were validated using experimental data for heat transfer coefficient and pressure drop in helical coiled tube for different Reynolds numbers. Four different geometries were simulated and compared. The first one was a conical coiled tube; the others were helical coiled tubes whose coil diameters were minimum, maximum, and median of the conical coiled tube pitch coil diameter. The velocity profiles indicated stronger secondary flow in conical coiled tube at a specified Dean number. The obtained results also showed higher heat transfer enhancement in the conical coiled tube in comparison with helical coiled tube with the same average pitch coil diameter. Moreover, the nanoparticle-induced heat transfer enhancement was more effective in conical coiled tube.

  相似文献   

9.
Journal of Thermal Analysis and Calorimetry - In this study, the subcooled boiling heat transfer of a Fe3O4/water magnetic nanofluid flowing through a vertical tube has been investigated...  相似文献   

10.
An organic/inorganic polyaniline-wrapped halloysite nanotube (PANI/HNT) composite was prepared by the in situ polymerization of aniline in the presence of a HNT dispersion. The physical properties of the resulting PANI/HNT composite were characterized by scanning electron microscopy, thermogravimetric analysis, and Fourier-transform infrared spectroscopy. This organic/inorganic composite particle was then dispersed in silicone oil as an electrorheological (ER) fluid, and its ER properties were examined using a Couette-type rotational rheometer equipped with a high-voltage generator. This novel halloysite composite-based ER fluid exhibited typical ER properties under an applied electric field.  相似文献   

11.
In the present study, the effect of volume concentration (0.05, 0.1 and 0.15 %) and temperature (10–90 °C) on viscosity and surface tension of graphene–water nanofluid has been experimentally measured. The sodium dodecyl benzene sulfonate is used as the surfactant for stable suspension of graphene. The results showed that the viscosity of graphene–water nanofluid increases with an increase in the volume concentration of nanoparticles and decreases with an increase in temperature. An average enhancement of 47.12 % in viscosity has been noted for 0.15 % volume concentration of graphene at 50 °C. The enhancement of the viscosity of the nanofluid at higher volume concentration is due to the higher shear rate. In contrast, the surface tension of the graphene–water nanofluid decreases with an increase in both volume concentration and temperature. A decrement of 18.7 % in surface tension has been noted for the same volume concentration and temperature. The surface tension reduction in nanofluid at higher volume concentrations is due to the adsorption of nanoparticles at the liquid–gas interface because of hydrophobic nature of graphene; and at higher temperatures, is due to the weakening of molecular attractions between fluid molecules and nanoparticles. The viscosity and surface tension showed stronger dependency on volume concentration than temperature. Based on the calculated effectiveness of graphene–water nanofluids, it is suggested that the graphene–water nanofluid is preferable as the better coolant for the real-time heat transfer applications.  相似文献   

12.
Conventional heat transfer fluids such as water and ethylene glycol (EG) can be used for cooling fluids in car radiators, and have relatively poor heat transfer performance. One method for increasing heat transfer in car radiators uses nanofluids. Nanofluids as a new technology are obtained by dispersing nanoparticles on the base fluids. In the present study, CuO (60 nm) nanoparticles were used in a mixture of water/EG as a base fluid. Then, the thermal performance of a car radiator was studied. The experiment was performed for different volumetric concentrations (0.05–0.8 vol%) of nanofluids of different flow rates (4–8 lit/min) and inlet temperatures (35, 44, 54°C). The results showed that nanofluids clearly enhanced heat transfer compared to the base fluid. In the best condition, the heat transfer coefficient enhancement of about 55% compared to the base fluid was recorded.  相似文献   

13.

In this research, it is aimed to enhance the heat transfer properties of the carbon nanotubes through nitrogen doping. To this end, nitrogen-doped multiwall carbon nanotubes (N-CNTs) were synthesized via chemical vapor deposition method. For supplying carbon and nitrogen during the synthesis of N-CNTs, camphor and urea were used, respectively, at 1000 °C over Co–Mo/MgO nanocatalyst in a hydrogen atmosphere. N-CNTs with three different nitrogen loadings of 0.56, 0.98, and 1.38 mass% were synthesized, after which, water/N-CNT nanofluids of these three samples with concentrations of 0.1, 0.2, and 0.5 mass% were prepared. To obtain a stable nanofluid, N-CNTs were functionalized by nitric acid followed by stabilizing in water by employing the ultrasonic bath. Investigation on the stability of the samples showed a high stability level for the prepared water/N-CNT nanofluids in which the zeta potential of ??43.5 mV was obtained for the best sample. Also for studying the heat transfer properties, the thermal conductivity in the range of 0.1–0.5 mass% and convection heat transfer coefficients of nanofluids in the range of 0.1–0.5 mass%, and Reynolds number in the range of 4000–9000 were evaluated. The results showed 32.7% enhancement of the convection heat transfer coefficients at Reynolds number of 8676 and 27% increase in the thermal conductivity at 0.5 mass% and 30 °C.

  相似文献   

14.

Present experimental investigation incorporates characterization of Al nanopowder, synthesis of Al/water nanofluids, and effect of these nanofluids on thermal performance of compact heat exchanger. Al nanoparticles are characterized using TEM and XRD. Al/water nanofluid is prepared by dispersing metal basis aluminium nanoparticles of average 100 nm size into double distilled water at two different particle volume concentrations of 0.1 and 0.2%. The nanofluids are prepared by two-step method and cetyl trimethyl ammonium bromide surfactant is used to stabilize the nanofluid. Thermo-physical properties of nanofluids at two different concentrations and their variation with fluid temperature are measured experimentally. It is examined that thermal conductivity, viscosity, and density of the nanofluid increased with the increase of volume concentrations. Furthermore, by increasing the fluid temperature, thermal conductivity is intensified, while the viscosity and density are decreased. Heat transfer parameters are strong functions of these thermo-physical properties. Therefore, comprehensive findings on heat transfer coefficient, Nusselt number, colburn factor, friction factor, and effectiveness are determined experimentally for prepared nanofluids passing under laminar conditions through single-pass cross-flow compact heat exchanger attached with multi-louvered fins.

  相似文献   

15.

The objective of this paper is to investigate thermal efficiency enhancement methods in a linear Fresnel reflector (LFR) with evacuated tube receiver. The primary reflectors of the collector are flat mirrors of 27 m2 total net aperture, while the secondary reflector has a parabolic shape. The working fluid is Syltherm 800, and the analysis is performed for temperatures up to 650 K. The use of nanofluids and internal fins is the investigated thermal enhancement methods in the receiver of the LFR. The examined nanofluid is Syltherm/CuO for concentrations 2, 4 and 6%, while the examined internal fins are 8 longitudinal fins which are symmetrically located in the absorber. The LFR is examined using nanofluids and pure thermal oil in smooth or finned absorber. According to the final results, the maximum thermal efficiency enhancement is up to 1% and it is greater for higher operating temperature levels. The use of internal fins is better enhancement method compared to the use of nanofluids, while the combination of these two techniques leads to the highest possible performance. For the inlet temperature of 600 K with 200 L min?1 flow rate, the thermal efficiency enhancement with 4% nanofluid and finned absorber is found 0.82%, while it is found 0.61 and 0.28% with finned absorber with pure oil and 4% nanofluid with smooth absorber, respectively.

  相似文献   

16.
A microfabricated linear heater array operating in a constant voltage mode has been used to study the effect of nanoparticle size on the evaporation and dryout characteristics of strongly pinned nanofluid droplets. Four different nanofluids have been tested, containing 2-nm Au, 30-nm CuO, 11-nm Al2O3, and 47-nm Al2O3 nanoparticles, each of 5-muL droplets with 0.5 vol % in water. Nanofluid droplets show strong pinning along the droplet perimeter and, upon evaporation, leave a ring-shaped nanoparticle stain. Particle size is seen to have a clear and strong effect on the dryout stain pattern, while heater temperature seems to have little effect. With the assumption of axi-symmetry, tomographic deconvolution of measured data from the linear heater array allows for examination of the spatially and temporally resolved temperature and heat flux characteristics of the evaporating nanofluid droplets.  相似文献   

17.

This study aimed to investigate the increase in heat transfer in the indirect heater at a city gate station (CGS) with the addition of copper oxide (CuO) nanoparticles to water–ethylene glycol base fluids. Indirect heaters are typically used at CGSs to raise the heat transfer coefficient of output gas flow from ? 5 to 15 °C. Moreover, manufacturing laboratory equipment in the presence of water–ethylene glycol base fluid and the nanoparticle in volume fractions of 0.05, 0.1, 0.2, and 0.3 at a temperature of 40–70 °C was discussed using dimensional simulation and analysis. The physical properties of the base fluid and nanofluid were measured using precise devices. Heat transfer tests for the base and nanofluid, as well as replacing of the air by gas, were conducted in a simulated and developed device. According to the obtained results with respect to the changes in convection and conduction heat transfer, enhancement of temperature difference at a rate of 36% was observed in the indirect heater with nanoparticle volume concentration of 0.2% at a temperature of 70 °C. Moreover, the Nusselt number showed a relatively good agreement with theoretical discussions.

  相似文献   

18.
In this paper, a review of the impact of most common nanoparticles on the Leidenfrost temperature T Leid in heat transfer applications is delivered. Moreover, a simple economic analysis of the nanoparticles use is proposed. When coolant is distilled water, T Leid can range 150–220 °C; occasionally, it can even amount to over 400 °C. When the base liquid is modified by additives, considerable changes in the character of heat transfer are observed. Out of five nanofluids under consideration in this study, the best thermal effect (up to 50%) is obtained when Al2O3 nanofluid having particle sizes ~39 nm and volume concentration of 0.1% is used. Conversely, the fluid containing TiO2 particles, 20–70 nm in size, seems to be the worst of the analysed fluid, giving only 7% heat transfer enhancement in comparison with water. However, when TiO2 nanoparticles are far smaller, very good thermal effects are obtained (23–25%). In a majority of the cases analysed, the temperature that marks the onset of film boiling is inversely proportional to concentrations of nanoparticles, which is relevant from the economic standpoint.  相似文献   

19.
Thermal conductivity is an important parameter in the field of nanofluid heat transfer. This article presents a novel model for the prediction of the effective thermal conductivity of nanofluids based on dimensionless groups. The model expresses the thermal conductivity of a nanofluid as a function of the thermal conductivity of the solid and liquid, their volume fractions, particle size and interfacial shell properties. According to this model, thermal conductivity changes nonlinearly with nanoparticle loading. The results are in good agreement with the experimental data of alumina-water and alumina-ethylene glycol based nanofluids.  相似文献   

20.
An experimental study was carried out to investigate the thermal performance of a flat capillary pumped loop (CPL) using the water based and the ethanol based Cu nanofluids as the working fluids under several steady sub-atmospheric operating pressures. The evaporator of the CPL was placed horizontally and heated from the bottom. The experimental results show that adding Cu nanoparticles into both base fluids can significantly enhance the evaporating heat transfer coefficient and the maximum heat removal capacity. There is an optimal mass concentration of Cu nanoparticles corresponding to the maximum heat transfer enhancement. The operating temperature or the operating temperature has an apparent effect on the heat transfer enhancement. The heat transfer enhancement effects increase distinctly with increasing the operating temperature. The heat transfer coefficient and the maximum heat removal capacity can be increased up to 45% and 16% after substituting Cu-ethanol nanofluids for the base fluids, respectively. The present investigation discovered that the thermal performance of a CPL can be evidently strengthened by using Cu nanofluids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号