首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
《Analytical letters》2012,45(3):565-584
ABSTRACT

Cocaine HCl is a substance which creates psychological and physical dependence. Usually it is available on the market being diluted by other substances, like local anesthetics, analeptics and CNS stimulating agents and inert substance.

In this study, HPLC and GLC methods were applied for qualitative and quantitative determinations of synthetic binary mixtures. In the HPLC determination, μ Bondopack C18 10 μm. column system, a mobile phase consisting of methanol-water-phosphoric acid-1% hexylamine (75:175:250:3,5) and U.V. detection by photodiodearray (196–600 nm) were used.

The linear concentration areas were found in a range of 2.5–25 μg/mL. The R.S.D percentages for cocaine HCl, procaine HCl, lidocaine HCl and caffeine were found as 0.922, 0.568, 1.18 and 1.04, respectively.

In the GLC determination, two different column systems, a 2% OV-17-Gas Chrom W-HP 100–200 mesh filled column and a 0.25 SE-52 fused silica capillary column, were used. Nitrogen was used in a filled column and helium was used in a capillary column. Mobile phase flow rates were set as 30 mL/min and a flame ionization detector was used with both column systems.

The linear concentration intervals were found in a range of 2–25 μL/mL in both methods. The R.S.D. for cocaine HCl, procaine HCl, lidocaine HCl, and caffeine were found to be 0.907, 0.948, 0.770, 0.901 in the filled column. For cocaine HCl, procaine HCl and caffeine R.S.D.'s of 0.774, 0.809, 0.814 were found, when a capillary column was used. In quantitative determinations, antipyrine was chosen as internal standard in the HPLC and GLC methods.  相似文献   

2.
A stability-indicating reversed-phase high-performance liquid chromatography (LC) method was developed and validated for the determination of hydrochlorothiazide in an oral suspension. Isocratic chromatography was performed on a C18 column with 0.1 M sodium phosphate buffer pH 3.0/acetonitrile (70:30 v/v) as mobile phase, at a flow rate of 1.3 mL min−1, and UV detection at 254 nm. The method was linear (r 2 = 0.9998), accurate (mean recovery = 100.3%), and precise (RSD <2%). It was also validated for specificity and robustness. The method was successfully applied for the quality control analysis of a new pharmaceutical formulation of HCTZ for pediatric use.  相似文献   

3.
A stability-indicating reversed-phase liquid chromatographic (RPLC) method has been established for analysis of ramipril (RAM) and moexipril hydrochloride (MOEX.HCl) in the presence of the degradation products generated in studies of forced decomposition. The drug substances were subjected to stress by hydrolysis (0.1 m NaOH and 0.1 m HCl), oxidation (30% H2O2), photolysis (254 nm), and thermal treatment (80 °C). The drugs were degraded under basic and acidic conditions and by thermal treatment but were stable under other stress conditions investigated. Successful separation of the drugs from the degradation products was achieved on a cyanopropyl column with 40:60 (v/v) aqueous 0.01 m ammonium acetate buffer (pH 6)–methanol as mobile phase at a flow rate of 1 mL min−1. Detection was by UV absorption at 210 nm. Response was a linear function of concentration over the range 5–50 μg mL−1 (r > 0.9995), with limits of detection and quantitation (LOD and LOQ) of 0.04 and 0.09 μg mL−1, respectively, for RAM and 0.014 and 0.32 μg mL−1, respectively, for moexipril. The method was validated for specificity, selectivity, solution stability, accuracy, and precision. Statistical analysis proved the method enabled reproducible and selective quantification of RAM and MOEX as the bulk drug and in pharmaceutical preparations. Because the method effectively separates the drugs from their degradation products, it can be used as stability-indicating.  相似文献   

4.
A new liquid chromatographic method has been developed and validated for the determination of terbutaline sulfate (TLS), guaifenesin (GFN) and ambroxol HCl (AML), for its potential impurities in drug substances and drug products. Efficient chromatographic separation was achieved on X-Terra RP-18 column with a simple mobile phase combination containing a gradient mixture of solvents A and B at a flow rate of 1.0 mL min−1 and quantitation was carried out using ultraviolet detection at 222 nm with column temperature of 35 °C. The resolution between TLS, GFN and AML, its associated impurities was found to be greater than 1.5. Regression analysis shows an r value (correlation coefficient) greater than 0.998. This method was capable to detect all the process impurities of TLS, GFN and AML, at a level below 0.015% with respect to a test concentration of 0.125, 5.0 and 1.5 mg mL−1, respectively. The % RSD for the inter-day and intra-day precisions for all the impurities of TLS, GFN and AML were found to be less than 3.0. The method has shown good, consistent recoveries. The drugs were subjected to stress conditions of acid, base, water hydrolysis, oxidation, photolysis and thermal degradation, as prescribed by international conference on harmonization (ICH).  相似文献   

5.
The study aimed to develop a new reverse-phase high-performance liquid chromatography (RP-HPLC) method with diode array detection (DAD) detection for simultaneous estimation of escitalopram (EST) and clonazepam (CZP) in tablet dosage forms with a quality by design (QbD) approach. The chromatographic conditions were optimized by Box-Behnken design (BBD) and developed method was validated for the linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability according to International Council for Harmonization (ICH) guidelines. EST and CZP standard drugs peaks were separated at retention times of 2.668 and 5.046 min by C-18 column with dimension of 4.6 × 100 mm length and particle size packing 2.5 µm. The mobile phase was methanol: 0.1% orthophosphoric acid (OPA) (25:75, v/v), with a flow rate of 0.7 mL/min at temperature of 26 °C. The sample volume injected was 20 µL and peaks were detected at 239 nm. Using the standard calibration curve, the % assay of marketed tablet was founded 98.89 and 98.76 for EST and CZP, respectively. The proposed RP-HPLC method was able to detect EST and CZP in the presence of their degradation products, indicating the stability-indicating property of the developed RP-HPLC method. The validation parameter’s results in terms of linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability were in an acceptable range as per the ICH guidelines. The newly developed RP-HPLC method with QbD application is simple, accurate, time-saving, and economic.  相似文献   

6.
《Analytical letters》2012,45(16):2487-2495
A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of aucubin in Plantago lanceolata. The analyses were carried out on Zorbax SB-C18 column with an aqueous phosphoric acid and acetonitrile gradient. The correlation coefficient of calibration curve showed good linearity (r > 0.9995), with average recoveries between 96.7 and 104.5%. The developed method was applied for quantification in P. atrata, P. bellardii, P. coronopus, P. holosteum, P. reniformis, and P. schwarzenbergiana. The aucubin content in plant extracts was compared by HPLC, HPTLC, and LC-ESI-MS techniques and no significant differences between the conducted methods were observed.  相似文献   

7.
Vortioxetine (VOR) is a new antidepressant drug used to treat major depressive disorder. In this work, a novel, simple, rapid, accurate, precise, selective, stability-indicating, and fully validated high-performance liquid chromatography method with diode array detection (HPLC-DAD) was developed to determine VOR in bulk and pharmaceutical formulations. A Polar-RP column was used, with a mobile phase consisting of acetonitrile (ACN), methanol (MeOH), acetate buffer pH 3.5, and addition of diethylamine (DEA) in the isocratic elution mode. Assessing the stability of the VOR is fundamental to guarantee the efficacy, safety, and quality of drug products. In this study, the VOR active pharmaceutical ingredient (API) and tablets were subjected to a detailed study of forced degradation, using several degrading agents (acid, alkaline, water, heat, light, and oxidation agents). The developed HPLC-DAD method allows the collection of all the essential data to determine degradation kinetics. It was found that the decomposition of vortioxetine is fragile towards oxidative conditions and photolysis, yielding the first-order and second-order kinetic reaction in the above stress conditions, respectively. The degradation products (DPs) were identified by the high-resolution liquid chromatography coupled with electrospray ionization-quadrupole-time of flight-mass spectrometry (LC-ESI-QTOF-MS) method. The HPLC-DAD method was successfully applied for the quantification of VOR in tablets. Additionally, in silico toxicity prediction of the DPs was performed.  相似文献   

8.
A method was developed for the rapid and quantitative analysis of 30 veterinary drugs belonging to 17 classes (amphenicols (1), anthelmintics (1), cephalosporins (4), coccidiostats (1), lincosamides (1), macrolide (1), nitroimidazole (1), penicillins (3), phenylhydrazines (1), polypeptides (1), pyrethrins (1), quinolones (5), sulfonamides (3), tetracycline (3), neuroleptic agents (1), triazene trypanocidal agents (1), other. (1)) in feeds. The proposed method with a modified Quick Polar Pesticides (QuPPe) sample preparation was validated for the determination of 30 veterinary drugs in feed samples by liquid chromatography triple-quadrupole mass spectrometry (LC–MS/MS). The sample was extracted with methanol containing 1% acetic acid and purified by dispersive solid-phase extraction (d-SPE) with C18. Good linearity (r2 ≥ 0.98) was observed, and the LOQ values ranged from 10 to 200 µg/kg. Average recoveries ranged from 70.8 to 118.4%, and the relative standard deviation was ≤ 18.7%. This validated method was used in the determination of 30 veterinary drugs in 142 feed samples obtained from South Korea. The results show that lincomycin was present in only one of the tested feed samples, although it was detected at a value lower than the LOQ. In conclusion, this multi-residue method can be used for screening through the detection and quantitation of residual multiclass veterinary drugs in feed samples.  相似文献   

9.
A novel and efficient stability-indicating, reverse phase ultra-performance liquid chromatographic (UPLC®) analytical method was developed and validated for the determination of hexoprenaline in an injectable dosage form. The development of the method was performed using analytical quality by design (AQbD) principles, which are aligned with the future requirements from the regulatory agencies using AQbD principles. The method was developed by assessing the impact of ion pairing, the chromatographic column, pH and gradient elution. The development was achieved with a Waters Acquity HSS T3 (50 × 2.1 mm i.d., 1.8 µm) column at ambient temperature, using sodium dihydrogen phosphate 5 mM + octane-1-sulphonic acid sodium salt 10 mM buffer pH 3.0 (Solution A) and acetonitrile (Solution B) as mobile phases in gradient elution (t = 0 min, 5% B; t = 1 min, 5% B; t = 5 min, 50% B; t = 7 min, 5% B; t = 10 min, 5% B) at a flow rate of 0.5 mL/min and UV detection of 280 nm. The linearity was proven for hexoprenaline over a concentration range of 3.50–6.50 µg/mL (R2 = 0.9998). Forced degradation studies were performed by subjecting the samples to hydrolytic (acid and base), oxidative, and thermal stress conditions. Standard solution stability was also performed. The proposed validated method was successfully used for the quantitative analysis of bulk, stability and injectable dosage form samples of the desired drug product. Using the AQbD principles, it is possible to generate methodologies with enhanced knowledge, which can eventually lead to a reduced regulatory risk, high quality data and lower operational costs.  相似文献   

10.
A rapid, selective and sensitive high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) method was developed to determine meloxicam in beagle dog plasma. Sample pretreatment involved a one‐step protein precipitation with methanol of 0.1 mL plasma. Analysis was performed on a Venusil ASB‐C18 column with mobile phase consisting of methanol–water (containing 0.1% formic acid) (75:25, v/v). The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization source. Each plasma sample was chromatographed within 4.1 min. The linear calibration curves for meloxicam was obtained in the concentration range of 10.3–4.12 × 103 ng/mL (r ≥ 0.99). The intra‐ and inter‐day precisions (relative standard deviation) were ≤ 15%, and accuracy (relative error) was within ±7.3%. The method herein described was fully validated and successfully applied to the pharmacokinetic study of meloxicam tablets in beagle dog.  相似文献   

11.
采用三维荧光光谱法,结合化学计量学中基于交替归一加权残差(ANWE)算法的二阶校正方法,实现了人血浆样品中川芎嗪和替米沙坦的同时快速定量分析.当组分数N取4时,ANWE算法解析获得的川芎嗪和替米沙坦的平均回收率分别为99.3士3.5%和96.8±2.0%.本文同时给出了此方法的检测限(LOD)与定量下限(LOQ),获得...  相似文献   

12.
Calcium blocker drugs are of increasing therapeutic relevance. Verapamil, nifedipine, diltiazem, and flunarizine are the most widely applied drugs of this type. New dihydropyridines (felodipine, nitrendipine) and related agents are presently undergoing intense investigation. HRGC and HPLC were used to determine eight of these drugs in spiked plasma samples. Both methods allow separation of most of the compounds in a single run and are specific, sensitive, and reproducible both for therapeutic monitoring and for pharmacokinetic studies in man and animals.  相似文献   

13.
An assay is presented for simultaneously determining 5 biogenic amines and the major non-protein amino acids: the toxin β-N-oxalyl-L-α,β-diaminopropanoic acid (β-ODAP), its isomer α-ODAP and homoarginine in Lathyrus sativus extracts using the HPLC system after derivatization with para-nitrobenzyloxycarbonyl chloride (PNZ-Cl). However, it is more worthy of noting that this paper also describes a new extraction method using 0.2 mol/L HClO4. The new method has some advantages: shorter extraction-time, simultaneous extraction of free amino acids and polyamines, better inhibiting the isomerization of β-ODAP to α-ODAR and so on.  相似文献   

14.
Abstract

A HPLC method has been developed for trace analysis of chlorophenols in the 0.2–2 ppb range from spiked water samples. Simple liquid-liquid extraction followed by on-line preconcentration of total mono- and dichlorophenols has been performed using a divinylbenzene-styrene copolymeric sorbent (PRP1) as packing material for the precolumn. The chlorophenols have been eluted from the precolumn on an analytical column (5μm LiChrosorb RP-18, 12.5 cm × 4 mm) by use of a switching valve system followed by separation. Detection was carried out with an electrochemical detector. The linearity of the detector response has been proved over two orders of magnitude. The detection limit of chlorophenols by means of the electrochemical method is in the lower picogram range. The recoveries of the isomeric chlorophenols from spiked river water samples having initial concentrations of 2ppb are usually 70–90%. The procedure has been applied to drinking water and river water.  相似文献   

15.
In this study, comparative analyses were carried out with ion chromatography mass-spectrometry (IC-MS/MS) which has no derivatization step, high-performance liquid chromatography (HPLC) technique, as well as two quantitative and two semi-quantitative immunoassays. The results demonstrated that HPLC and quantitative immunoassay methods were well-correlated with IC-MS/MS in determining histamine in various types of fish products. The best correlation was observed with the HistaSure ELISA Fast Track kit (R2 = 0.9903). More than half of the values (68%) obtained by two methods were also statistically similar. The results of semi-quantitative test kits also supported histamine values estimated by quantitative methods, with some exceptions. The best results were found for HistaSure Lateral Flow in supporting the quantitative techniques. Therefore, these methods are found suitable for monitoring histamine in fish products in terms of food safety. Good correlations were also observed HPLC and IC-MS/MS in determining cadaverine, putrescine, and tyramine with the highest value observed for tyramine as R2 = 0.9785. However, no correlation was observed for other biogenic amines, and the majority of the results were significantly different from each other for these amines (p < 0.05). The differences may be caused by the drawbacks reported previously for HPLC. However, further studies are required to confirm the possible effects. This study provides a comparative evaluation of several methods in terms of their suitability in determining biogenic amines in fish products for both monitoring and regulatory purposes.  相似文献   

16.
JPC – Journal of Planar Chromatography – Modern TLC - A new simple, rapid, and selective high-performance thin-layer chromatographic (HPTLC) method with metronidazole as the internal...  相似文献   

17.
L-Dopa (LD), a substance used medically in the treatment of Parkinson’s disease, is found in several natural products, such as Vicia faba L., also known as broad beans. Due to its low chemical stability, LD analysis in plant matrices requires an appropriate optimization of the chosen analytical method to obtain reliable results. This work proposes an HPLC-UV method, validated according to EURACHEM guidelines as regards linearity, limits of detection and quantification, precision, accuracy, and matrix effect. The LD extraction was studied by evaluating its aqueous stability over 3 months. The best chromatographic conditions were found by systematically testing several C18 stationary phases and acidic mobile phases. In addition, the assessment of the best storage treatment of Vicia faba L. broad beans able to preserve a high LD content was performed. The best LD determination conditions include sun-drying storage, extraction in HCl 0.1 M, chromatographic separation with a Discovery C18 column, 250 × 4.6 mm, 5 µm particle size, and 99% formic acid 0.2% v/v and 1% methanol as the mobile phase. The optimized method proposed here overcomes the problems linked to LD stability and separation, thus contributing to the improvement of its analytical determination.  相似文献   

18.
《Electroanalysis》2018,30(8):1880-1885
This work presents a simple and low‐cost method for fast and selective determination of Verapamil (VP) in tablets and human urine samples using a boron‐doped diamond working electrode (BDD) coupled to a flow injection analysis system with multiple pulse amperometric detection (FIA‐MPA). The electrochemical behaviour of VP in 0.1 mol L−1 sulfuric acid showed three merged oxidation peaks at around +1.4 V and upon reverse scan, one reduction peak at 0.0 V (vs. Ag/AgCl). The MPA detection was performed applying a sequence of three potential pulses on BDD electrode: (1) at +1.6 V for VP oxidation, (2) at +0.2 V for reduction of the oxidized product and (3) at +0.1 V for cleaning of the working electrode surface. The FIA system was optimized with injection volume of 150 μL and flow rate of 3.5 mL min−1. The method showed a linear range from 0.8 to 40.0 μmol L−1 (R>0.99) with a low limit of detection of 0.16 μmol L−1, good repeatability (RSD<2.2 %; n=10) and sample throughput (45 h−1). Selective determination of VP in urine was performed at+0.2 V due to absence of interference from ascorbic and uric acids in this potential. The addition‐recovery tests in both samples were close to 100 % and the results were similar to an official method.  相似文献   

19.
We report a novel, simple, rapid and sensitive electrochemical method for the determination of sulcotrione, a member of the relatively new class of triketone herbicides, using differential pulse voltammetry on a glassy carbon electrode. Its electrochemical behavior including influences of electrolyte composition, pH and scan rate was studied to select optimal experimental parameters for its determination. In Britton? Robinson buffer at pH 3 sulcotrione provided a well‐defined reduction peak at ?0.84 V (vs. Ag/AgCl electrode), with good repeatability (relative standard deviation of 2.3 % for 8 measurements at 10 µM concentration level). With optimized parameters differential pulse voltammetry rendered two linear concentration ranges from 0.2 to 2 µM and from 2 to 50 µM with a detection limit of 0.05 µM. The proposed procedure was successfully applied to the determination of sulcotrione in spiked river water samples with satisfactory recoveries (93–109 %). The developed method may represent a simple, rapid and sensitive alternative to highly toxic mercury electrodes and chromatographic methods.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号