1.
Guanidinoacetic acid (GAA) measurement has recently become of great interest for the diagnosis of creatine (Cn) metabolism disorders, and research calls for rapid and inexpensive methods for its detection in plasma and urine in order to assess a large number of patients. We propose a new assay for the measurement of GAA by a simple CZE UV-detection without previous sample derivatization. Plasma samples were filtered by Microcon-10 microconcentrators and directly injected into the capillary, while for urine specimens a simple water dilution before injection was needed. A baseline separation was obtained in less than 8 min using a 60.2 cm x 75 microm uncoated silica capillary, 75 mmol/L Tris-phosphate buffer pH 2.25 at 15 degrees C. The performance of the developed method was assessed by measuring plasma creatinine and Cn in 32 normal subjects and comparing the data obtained by the new method with those found with the previous CE assay. Our new method seems to be an inexpensive, fast and specific tool to assess a large number of patients both in clinical and in research laboratories.  相似文献   

2.
马玉花  黄冬群  张瑞  徐世茹  封顺 《色谱》2013,31(11):1102-1105
建立了高效液相色谱(HPLC)同时测定尿液中4种常见的非蛋白氮物质--肌酸(Cr)、尿肌酐(Cn)、尿酸(Ua)及假尿嘧啶核苷(Pu)含量的方法。尿液首先经丙酮沉淀法除去大分子化合物,然后冷冻干燥,复溶后直接进行HPLC分析。色谱分离选用Waters RP18 Column (150 mm×4.60 mm,3.5 μm),以10.0 mmol/L磷酸缓冲溶液 (pH 4.78)和乙腈为流动相进行梯度洗脱,流速为0.8 mL/min,于220 nm波长下检测,可在7 min内完成4种非蛋白氮的快速分离分析。结果表明Cr、Cn、Ua、Pu在0.1~250 mg/L范围内线性关系均良好(相关系数均大于0.999),检出限分别为9.31、26.19、4.70、6.30 μg/L,加标回收率为81%~111%,峰高的相对标准偏差(RSD, n=3)为0.23%~2.78%,满足定量要求。该法简便、快速,结果准确可靠,为2型糖尿病(T2DM)患者肾功能损坏的研究提供了检测手段。  相似文献   

3.
A simple, sensitive, and useful concentration method for lovastatin (Lvt) in urine has been developed based on the transient moving chemical reaction boundary method (tMCRBM) in capillary electrophoresis. The MCRB is formed with acidic sample buffer (Gly-HCl) and alkaline running buffer (Gly-NaOH). The following optimal conditions were determined for stacking and separation: electrophoretic buffer of 100 mM Gly- NaOH (pH 11.52), sample buffer of 20 mM Gly-HCl (pH 4.93), fused-silica capillary of 76 cm × 75-μm i.d (67 cm from detector), sample injection at 14 mbar for 3 min. A 21- to 26-fold increase in peak height was achieved for detection of Lvt in urine under the optimal conditions compared with normal capillary zone electrophoresis. By combining the sample pretreatment procedure with the stacking method, the sensitivity of Lvt in urine was increased by 105- to 130-fold. The limits of detection (LOD) and quantification (LOQ) for Lvt in urine were decreased to 8.8 ng/mL and 29.2 ng/mL, respectively. The intra-day and inter-day precision values (expressed as RSD) were 2.23–3.61% and 4.03–5.05%, respectively. The recoveries of the analyte at three concentration levels changed from 82.65 to 100.49%.  相似文献   

4.
Two cheap, simple and reproducible methods for the electrophoretic determination of homocysteine thiolactone (HTL) in human urine have been developed and validated. The first method utilizes off-line single drop microextraction (SDME), whereas the second one uses off-line SDME in combination with field amplified sample injection (FASI). The off-line SDME protocol consists of the following steps: urine dilution with 0.2 mol/L, pH 8.2 phosphate buffer (1:2, v/v), chloroform addition, drop formation and extraction of HTL. The pre-concentration of HTL inside a separation capillary was performed by FASI. For sample separation, the 0.1 mol/L pH 4.75 phosphate buffer served as the background electrolyte, and HTL was detected at 240 nm. A standard fused-silica capillary (effective length 55.5 cm, 75 μm id) and a separation voltage of 21 kV (~99 μA) were used. Electrophoretic separation was completed within 7 min, whereas the LOD and LOQ for HTL were 0.04 and 0.1 μmol/L urine, respectively. The calibration curve in urine was linear in the range of 0.1–0.5 μmol/L, with R2 = 0.9991. The relative standard deviation of the points of the calibration curve varied from 2.4% to 14.9%. The intra- and inter-day precision and recovery were 6.4–10.2% (average 6.0% and 6.7%) and 94.9–102.7% (average 99.7% and 99.5%), respectively. The analytical procedure was successfully applied to the analysis of spiked urine samples obtained from apparently healthy volunteers.  相似文献   

5.
A sensitive method for the simultaneous determination of chromium(III) (Cr3+) and chromium(VI) (CrO4(2-)) using in-capillary reaction, capillary electrophoresis (CE) separation and chemiluminescence (CL) detection was developed. The chemiluminescence reaction was based on luminol oxidation by hydrogen peroxide in basic aqueous solution catalyzed by Cr3+ ion followed by capillary electrophoresis separation. Based on in-capillary reduction, chromium(VI) can be reduced by acidic sodium hydrogensulfite to form chromium(III) while the sample is running through the capillary. Before the electrophoresis procedure, the sample (Cr3+ and CrO4(2-)), buffer and acidic sodium hydrogensulfite solution segments were injected in that order into the capillary, followed by application of an appropriate running voltage between both ends. As both chromium species have opposite charges, Cr3+ ions migrate to the cathode, while CrO4(2-) ions, moving in the opposite direction toward the anode, react with acidic sodium hydrogensulfite which results in the formation of Cr3+ ions. Because of the migration time difference of both Cr3+ ions, Cr(III) and Cr(VI) could be separated. The running buffer was composed of 0.02 mol l(-1) acetate buffer (pH 4.7) with 1 x 10(-3) mol l(-1) EDTA. Parameters affecting CE-CL separation and detection, such as reductant (sodium hydrogensulfite) concentration, mixing mode of the analytes with CL reagent, CL reaction reagent pH and concentration, were optimized. The limits of detection (LODs) of Cr(III) and Cr(VI) were 6 x 10(-13) and 8 x 10(-12) mol l(-1) (S/N=3), respectively. The mass LODs for Cr(III) and Cr(VI) were 1.2 x 10(-20) mol (12 zmol) and 3.8 x 10(-19) mol (380 zmol), respectively.  相似文献   

6.
The paper describes the enhanced separation of o-, m-, p-dihydroxybenzene by capillary electrochromatography (CEC) using gold nanoparticles (AuNPs) as stationary phase. The effect of the AuNPs concentration upon separation was investigated. The experimental parameters, including separation voltage, pH, and concentration of running buffer, were optimized. Under the optimum conditions, a good resolution of three dihydroxybenzene isomers was obtained within 15 min in a 50 cm effective length capillary modified with 0.02 nmol/L AuNPs at a separation voltage of 16 kV in a 50 mmol/L acetate buffer (pH 5.0). The linear ranges were from 10(-6) to 10(-4) mol/L and the detection limits were as low as 10(-7) mol/L. This method was successfully used to analysis two kinds of hair coloring agent sample with recoveries in the range of 90-105% and relative standard deviations (RSD) less than 5.0%.  相似文献   

7.
A capillary zone electrophoresis (CZE) method was developed for the rapid analysis of charge heterogeneity of immunoglobulin G (IgG) monoclonal antibodies (mAbs). The separation was carried out in a short, dynamically coated fused-silica capillary. A number of separation parameters were investigated and optimized, including pH, concentration of the separation buffer (ε-amino caproic acid), concentration of the triethylenetetramine (TETA) dynamic coating, the capillary internal diameter and the field strength used for the separation. The effects of between-run flushing of the capillary and the data acquisition rate were also evaluated. Under the optimized conditions, a fast (<5 min), selective and reproducible separation of mAb charge variants was achieved under a very high electric field strength (1000 V/cm). This method also requires only a short conditioning of the capillary, with between-run conditioning completed within 2 min. The method was evaluated for specificity, sensitivity, linearity, accuracy and precision. The same separation conditions were applied to the rapid separation (2-5 min) of charge variants of multiple monoclonal antibodies with pI in the range of 7.0-9.5. Compared with other existing methods for charge variants analysis, this method has several advantages including a short run time, rapid capillary conditioning and simple sample preparation.  相似文献   

8.
In this work, an ordered mesoporous titania film was introduced to coat a capillary by means of sol-gel technique. Sol-gel titania coating was developed for the preconcentration/separation of trace V, Cr and Cu by capillary microextraction (CME), and the adsorbed analytes were eluted for electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) detection. By immobilizing sol-gel titania on the inner surface of a fused-silica microextraction capillary, the sol-gel titania coating was prepared easily. Its adsorption properties, stability and the factors affecting the adsorption behaviors of V, Cr and Cu were investigated in detail. At pH range of 7 to 9, the titania-coated capillary (50 cm x 0.25 mm) is selective towards V, Cr and Cu, and the target analytes could be desorbed quantitatively with 50 microl of 1.0 mol l(-1) HNO3 at the rate of 0.05 ml min(-1). With a consumption of 2 ml sample solution, an enrichment factor of 33.3, and a detection limit (3 s) of 1.1 pg ml(-1) (10.5 fg) for V; 3.3 pg ml(-1) (33.0 fg) for Cr and 6.3 pg ml(-1) (63.1 fg) for Cu respectively were obtained. The precisions Relative Standard Deviations (RSDs) for nine replicate measurements of 1 ng ml(-1) V, Cr and Cu were 3.4, 5.1 and 6.4%, respectively. The proposed method has been applied to the determination of V, Cr and Cu in human urine and lake water, and the recoveries for these elements were 89.2 approximately 105%. The developed method was also applied to the determination of the target elements in NIES No. 10-a (rice flour-unpolished) and NIES No. 9 (sargasso) certified reference materials, and the results found are in good agreement with the certified values.  相似文献   

9.
A capillary zone electrophoresis (CZE) method using a fused-silica capillary (60.2 cm x 75 microm ID) was investigated for the determination of triamterene (TRI), methotrexate (MTX), and creatinine (CREA) in human urine. The separation was performed using a hydrodynamic injection time of 7 s (0.5 psi), a voltage of 25 kV, a capillary temperature of 30 degrees C, and 40 mM phosphoric acid adjusted to pH 2.25 by addition of triethanolamine as separation electrolyte. Under these conditions, analysis takes about 15 min. A linear response over the 0.5-15.0 mg L(-1) concentration range was found for TRI and MTX, and 0.5-80.0 mg L(-1) for CREA. Dilution of the sample (water:urine, 1:1 for TRI and MTX, and 1:25 for CREA determination) was the only step necessary prior to analysis by electrophoresis. The developed method is easy, rapid, and sensitive and has been applied to determine triamterene,methotrexate, and creatinine in urine samples with satisfactory results.  相似文献   

10.
A capillary electrochromatographic method was developed for the separation of barbiturates. The separation was optimized in a 75 microm ID capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effect of buffer pH, buffer concentration, and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 40% methanol provided the baseline separation of barbital, phenobarbital, secobarbital, and thiopental (internal standard) in less than 4.5 min. The method was successfully applied to the analysis of barbiturates in human serum. Under the optimal conditions, good repeatability and linearity were obtained in the range of 2.90-43.29 microg/mL for barbital, phenobarbital, and secobarbital.  相似文献   

11.
A simple, rapid and sensitive CE-fluorescence (FL) detection method for the analysis of alendronate (ALEN), a bisphosphonate drug, has been developed. Using a buffer solution of 20 mM sodium phosphate (pH 10.0) and a voltage of 24 kV, separation of ALEN in a 55-cm length (35-cm effective length) capillary was achieved in 5 min. FL detection of ALEN was performed via pre-column derivatization with 2,3-naphthalene dicarbox-yaldehyde (NDA). Linear correlation (r=0.9981, n=6) between FL intensity and analyte concentration was obtained in the range of 7-200 ng/mL ALEN. The developed CE-FL method was applied to the analysis of ALEN in human urine and plasma samples. In order to eliminate the interfering matrix components, SPE using magnetic Fe(3) O(4) @Al(2) O(3) nanoparticles as solid sorbents was employed to clean the biological fluids before CE-FL analysis. The linear ranges of ALEN in urine and plasma were 5-100 ng/mL (r = 0.9982, n = 7) and 5-70 ng/mL (r = 0.9954, n = 7), respectively. The LOD and LOQ in both urine and plasma samples were 1.5 and 5 ng/mL ALEN, respectively. Total analysis time including sample pre-treatment and CE separation was less than 1.5 h.  相似文献   

12.
A capillary electrochromatographic (CEC) method was applied to the simultaneous separation of barbiturates (barbital, phenobarbital, secobarbital and thiopental) and benzodiazepines (nitrazepam, diazepam and triazolam). The separation was performed in a 75 microm i.d. capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effects of buffer pH and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 45% methanol provided the baseline separation of seven toxic drugs in less than 9 min. In CEC with NAIP, the benzodiazepines were separated by the combination of hydrophobic and pi-pi interactions, whereas the separation of the barbiturates was based on the hydrophobic interaction.  相似文献   

13.
We employed CE to identify mixtures of the toxic alkaloids lappaconitine, bullatine A, atropine sulfate, atropine methobromide, scopolamine hydrobromide, anisodamine hydrobromide, brucine, strychnine, quinine sulfate, and chloroquine in human blood and urine, using procaine hydrochloride as an internal standard. The separation employed a fused-silica capillary of 75 microm id x 60 cm length (effective length: 50.2 cm) and a buffer containing 100 mM phosphate and 5% ACN (pH 4.0). The sample was injected in a pressure mode and the separation was performed at a voltage of 16 kV and a temperature of 25 degrees C. The compounds were detected by UV absorbance at wavelengths of 195 and 235 nm. All the ten alkaloids were separated within 16 min. The method was validated with regard to precision (RSD), accuracy, sensitivity, linear range, LOD, and LOQ. In blood and urine samples, the detection limits were 5-40 ng/mL and linear calibration curves were obtained over the range of 0.02-10 microg/mL. The precision of intra- and interday measurements was less than 15%. Electrophoretic peaks could be identified either by the relative migration time or by their UV spectrum.  相似文献   

14.
糖类衍生物在毛细管区带电泳下的分离研究   总被引:2,自引:0,他引:2  
以新合成的1-萘基-3-甲基-5-吡唑啉酮(NMP)为柱前衍生试剂,采用毛细管区带电泳模式考察并优化了糖类衍生物的分离条件。实验采用58.5cm×50μmi.d.毛细管(有效柱长50cm),55mmol/L硼酸盐缓冲溶液(pH9.46),柱温20℃,分离电压22kV,进样10s,在不加任何添加剂的情况下,高效、快速地实现了9种糖的基线分离,并在最优化条件下进行了唐古特白刺实际样品的分离分析,结果令人满意。  相似文献   

15.
A rapid and sensitive high-performance capillary electrophoretic method for the determination of clozapine and its main metabolite desmethylclozapine in human plasma was developed. The separation of the two analytes was carried out in an untreated fused-silica capillary [33 cm (8.5 cm effective length) x 50 microm I.D.] filled with a background electrolyte at pH 2.5 containing beta-cyclodextrin. Baseline separation of clozapine and desmethylclozapine was recorded in less than 3 min. An accurate sample pretreatment by means of solid-phase extraction and subsequent concentration allows for reliable quantitation of clozapine in the plasma of schizophrenic patients under treatment with the drug. The method showed good precision (mean RSD = 4.0%) as well as satisfactory extraction yields (approximately 88%) and a good sensitivity (limit of quantitation = 0.075 microg ml(-1), limit of detection = 0.025 microg ml(-1)).  相似文献   

16.
应用移动反应界面富集技术进行毛细管电泳尿液指纹分析   总被引:1,自引:0,他引:1  
吴进  樊柳荫  张薇  王秋玲  曹成喜 《色谱》2008,26(5):622-625
快速灵敏的尿液指纹图谱分析对于临床诊断中发现新的生物标记至关重要。该文建立了一种简便、快速、灵敏的移动反应界面(MRB)介导的富集技术进行毛细管电泳尿液指纹图谱分析。MRB由25 mmol/L甘氨酸(Gly)-HCl(pH 2.5)作为样品缓冲液和50 mmol/L Gly-NaOH(pH 12.3)作为电泳缓冲液形成。与常规的毛细管区带电泳只能观察到尿液中不到10个峰相比,采用MRB可以观察到超过80个峰并将检测灵敏度提高了至少十几倍,显示该方法对于代谢组学分析具有重要的意义。  相似文献   

17.
A sol-gel zirconia coating was developed for the preconcentration/separation of trace Cr, Cu, Cd and Pb by capillary microextraction, and the adsorbed analytes were on-line eluted for detection using inductively coupled plasma mass spectrometry (ICP-MS). By immobilizing sol-gel zirconia on the inner surface of a fused-silica capillary, the sol-gel zirconia coating was simply prepared. Its adsorption properties, stability and the factors affecting the adsorption behaviors of Cr, Cu, Cd and Pb were investigated in detail. In the pH range from 7.8 to 10, the zirconia-coated capillary (35 cm x 0.15 mm) is selective towards Cr, Cu, Cd and Pb, and the analyzed ions could be desorbed quantitatively with 0.2 mL of 0.5 mol/L HNO(3) at a rate of 0.2 mL/min. With a consumption of 1.25 mL sample solution, an enrichment factor of 6.25, and detection limits (3sigma) of 9.9 pg/mL Cr, 17.9 pg/mL Cu, 4.5 pg/mL Cd and 3.7 pg/mL Pb were obtained. The precisions for nine replicate measurements of 1 ng/mL Cr, Cu, Cd and Pb were 4.9% Cr, 2.2% Cu, 2.0% Cd and 3.2% Pb (RSD), respectively. The proposed procedure has been applied to the determination of Cr, Cu, Cd and Pb in human urine, which was subjected to microwave-assisted digestion prior to analysis, and the recoveries for these elements were 89.2-101.8%. In order to validate the developed procedure, a NIES No.10-a Rice Flour-Unpolished certified reference material and a BCR No. 184 Bovine Muscle certified reference material were analyzed, and the results are in good agreement with the certified values.  相似文献   

18.
A quantitative method of capillary electrophoresis with sample stacking induced by moving reaction boundary (MRB) was developed for sensitive determination of oxymatrine (OMT) and matrine (MT) in rat plasma. The experimental conditions were optimized firstly. Below are the optimized experimental conditions: 20 mM sodium formate solution (HCOONa, adjusted to pH 10.70 by ammonia) as sample solution, 3 min 14 mbar sample injection, 40 mM formic buffer (HCOOH-HCOONa, pH 2.60) as stacking buffer, 7 min 14 mbar injection of stacking buffer, 100 mM HCOOH-HCOONa (pH 4.80) as separation buffer, 73 cm capillary (effective length 64 cm), 21 kV voltage, 210 nm wavelength. Under the optimized conditions, higher than 60-fold sensitivity improvement of the stacking was simply achieved as compared with capillary zone electrophoresis, and the detectable limits obtained for OMT and MT were 0.26 and 0.19 μg mL−1, respectively. Then, numerous demonstrations were carefully performed for the methodological validations of OMT and MT in rate plasma, including high specificity of method, good linearity (r = 0.9993 for OMT, r = 0.9991 for MT), fair wide linear concentration range (1.30-65.00 μg mL−1 for OMT, 0.84-42.00 μg mL−1 for MT), low limit of detection (1.03 μg mL−1 for OMT, 0.38 μg mL−1 for MT), less than 5% intra- and inter-day variance value, and higher than 96% recovery of OMT and MT in plasma. The developed method could be used for the trace analyses of OMT and MT in plasma and was finally used for the investigation on pharmacokinetic study of OMT in rat plasma.  相似文献   

19.
Zhou XM  Liu JW  Zhang ME  Chen SJ 《Talanta》1998,46(4):757-760
The micellar electrokinetic capillary chromatography (MECC) method is reported for the separation of heparin, and for the possibility of direct determination of free heparin in plasma. The conditions for MECC were: pH 8.5, 25 mM sodium dodecyl sulfate (SDS), 25 mM borate buffer, with a 30 cmx50 mum ID fused-silica capillary. The sample was detected with a UV-detector at 270 nm with heparin as external standard. The recovery rate was 95.6-98.7%. This method was linear in the range 80-7000 U l(-1). The within-run and between-run relative standard deviations were lower than 3.1 and 4.5%, respectively. It is suggested that this MECC method may be used to determine blood samples containing high levels of heparin.  相似文献   

20.
Novel polymer monolith microextraction (PMME) using a poly(methacrylic acid-ethylene glycol dimethacrylate) (poly(MAA-EGDMA)) monolith in conjunction with capillary zone electrophoresis (CZE) was developed for the determination of several angiotensin II receptor antagonists (ARA-IIs) in human urine. The extraction device consisted of a regular plastic syringe (1 mL), a poly(MAA-EGDMA) monolithic capillary (2 cm x 530 microm I.D.) and a plastic pinhead connecting the former two components seamlessly. The extraction was achieved by driving the sample solution through the monolithic capillary tube using a syringe infusion pump, and for the desorption step, an aliquot of organic solvent was injected via the monolithic capillary and collected into a vial for subsequent analysis by CZE. The best separation was realized at 25 kV using a buffer that consisted of 50% acetonitrile and 50% buffer solution (v/v) containing 10 mM disodium hydrogenphosphate (adjusted to pH 2.3 with 1M hydrochloric acid). The method was successfully applied to the determination of telmisartan (T), irbesartan (I) and losartan (L) in urine samples with candesartan (C) as internal standard, yielding the detection limit of 15-20 ng/mL. Close correlation coefficients (R>0.999) and excellent method reproducibility were obtained for all the analytes over a linear range of 0.08-3 microg/mL.  相似文献   