首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
正相模式/反相模式的二维液相色谱系统的构建与应用   总被引:1,自引:0,他引:1  
兰韬  焦丰龙  唐涛  王风云  李彤  张维冰 《色谱》2008,26(3):374-377
以4.6mm×50 mm i. d.的Hypersil SiO2正相色谱柱为第一维,4.6mm×250 mm i. d.的Kromasil C18反相色谱柱为第二维,通过升高第二维色谱温度的方法增加两维流动相间互溶性的方法构建了定量环-阀切换接口的二维液相色谱系统(NPLC×RPLC)。根据有机溶剂的特征,在第一维正相色谱流动相中加入二氧六环;第二维反相色谱流动相中加入异丙醇,在改善流动相兼容性的同时,有效调整分离选择性。采用此系统对正天丸样品进行分离分析,达到1120的峰容量。  相似文献   

2.
硅胶色谱柱的亲水作用保留机理及其影响因素   总被引:1,自引:0,他引:1  
李瑞萍  袁琴  黄应平 《色谱》2014,32(7):675-681
亲水作用色谱(HILIC)是替代反相色谱(RPLC)分离强极性及亲水性化合物的另一色谱模式,其分离机理与RPLC有很大不同,具有和RPLC互补的选择性。在HILIC模式中,采用正相色谱(NPLC)中的极性固定相及含高浓度有机溶剂(通常为乙腈)的水溶液为流动相。硅胶是开发最早、研究最为深入及应用最为广泛的HILIC固定相,本文介绍了硅胶色谱柱的HILIC保留机理,详细概述了操作条件如硅胶柱类型、流动相组成及柱温对HILIC分离的影响,并对硅胶填料色谱柱的HILIC模式的发展方向与应用前景进行了展望。  相似文献   

3.
Three types of porous polymers containing different functional groups were synthesized as stationary phases for gas chromatography. The influence of functional groups in the copolymer skeletons on their selectivities was studied. To determine the selectivities of these copolymers, two procedures were applied: the selectivity triangle and the general selectivity. As a reference phase Porapak Q which does not contain any functional groups was used.  相似文献   

4.
A novel micellar selectivity triangle (MST) is developed and used to characterize and classify the chemical selectivities of pseudo-phases in electrokinetic chromatography (EKC). The MST scheme is, in concept, similar to the widely known solvent selectivity triangle (SST) originally developed by Snyder. However, the MST is based on linear solvation energy relationships. Thus it incorporates the solvation characteristics of both the pseudo-phase and the bulk solvent; while the SST is basically for classification of pure solvents. The similarities and differences of these pseudo-phases are determined by the relative scales of hydrogen bond donating ability (Xb), hydrogen bond accepting ability (Xa) and dipolarity (Xs). The MST scheme is used for characterization and classification of a wide range of pseudo-phases such as micelles, polymers, vesicles, liposomes, as well as mixed systems such as mixed micelles, mixed polymer–surfactants, organically modified pseudo-phases, etc. Over seventy pseudo-phases were examined and four clusters of pseudo-phases with different selectivity patterns are recognized that include pseudo-phases with strong hydrogen bond acidities (e.g. fluorinated micelles or micelles modified with fluorinated alcohols), strong hydrogen bond acceptor pseudo-phases (such as bile salts, liposomes, microemulsions, as well as biphasic octanol–water system), strong dipolar phase of a class of polymeric pseudo-phase, and pseudo-phases with intermediate hydrogen bonding and dipolarity [like sodium dodecyl sulfate (SDS) and its analogs as well as organically modified SDS]. The MST scheme is also useful in identifying pseudo-phases that closely resemble the selectivities of octanol–water for determination of octanol–water partition coefficients by EKC.  相似文献   

5.
L. Szepesy 《Chromatographia》2000,51(1):S98-S107
Summary Definition of chromatographic selectivity and the different selectivity terms, for example column selectivity, mobile phase selectivity, and temperature selectivity are discussed briefly. For classification of solvent selectivity the Rohrschneider-McReynolds system, the solvent selectivity triangle (SST) concept, the solubility parameter approach, and the linear solvation energy relationships (LSER) are compared. Shortcomings of the SST concept and application of the LSER method for the prediction of selectivity are discussed. Presented at Balaton Symposium on High Performance Separation Methods, Siófok, Hungary, September 1–3, 1999  相似文献   

6.
周永正  梁鑫淼  钟虹敏 《色谱》2000,18(1):42-45
 较为系统地研究了聚4甲基5乙烯基噻唑键合硅胶固定相(PMVCAphase)与C18,C8及苯基柱在反相色谱中甲醇水体系下的选择性差别。结果表明,该固定相与常用反相色谱固定相有相似性,显示了一般反相色谱固定相填料的特性;另一方面,又由于其特殊结构,更多地显示了其在反相色谱上的特殊选择性。  相似文献   

7.
Porous zirconia particles are very robust material and have received considerable attention as a stationary phase support for HPLC. We prepared cellulose dimethylphenylcarbamate-bonded carbon-clad zirconia (CDMPCCZ) as a chiral stationary phase (CSP) for separation of enantiomers of a set of 14 racemic compounds in normal phase (NP) and reversed-phase (RP) liquid chromatography. Retention and enantioselectivity on CDMPCCZ were compared to those on CDMPC-coated zirconia (CDMPCZ) to see how the change in immobilization method of the chiral selector affects the retention and chiral selectivity. In NPLC, retention was longer and the number of resolved racemates was smaller on CDMPCCZ than on CDMPCZ. However, chiral selectivity factors for some resolved racemates were better on CDMPCCZ than on CDMPCZ. The longer retention on CDMPCCZ is likely due to strong, non-chiral discriminating interactions with the carbon layer on CDMPCZ. In RPLC only two racemates were resolved on CDMPCCZ, but retention times were shorter than, and resolutions were comparable to, those in NPLC, indicating a potential for improving chromatographic performance of the CDMPCCZ column in RPLC with optimized column preparation and separation conditions.  相似文献   

8.
9.
A comprehensive orthogonal two-dimensional liquid chromatography (2D-LC) based on the modification of mobile phases was developed with a sample loop–valve interface. To improve the compatibility of mobile phases and analysis speed, some special solvents were chosen as the mobile phases, and the column temperature was elevated to decrease the viscosity of mobile phases of reversed-phase liquid chromatography (RPLC). Based on this principle, the first dimension was normal-phase liquid chromatography (NPLC) with a SiO2 column, and the second dimension was reversed-phase liquid chromatography containing two tandem C18 columns. 1,4-Dioxane was used in the NPLC mobile phase, and isopropyl alcohol was employed in the RPLC mobile phase. Moreover, the elevated column temperature enabled the reduction of the backpressure and using tandem C18 columns to improve the resolving power in RPLC. The new comprehensive 2D-LC system and applied strategy offered a novel idea for construction of 2D-LC system. A traditional Chinese medicine, Zhengtian pill, was used as the test sample to evaluate the constructed 2D-LC system. 876 peaks were detected, and the peak capacity reached 1740.  相似文献   

10.
以亲水作用色谱为核心的液相色谱联用技术及其应用研究   总被引:7,自引:0,他引:7  
王媛  顾惠新  路鑫  许国旺 《色谱》2008,26(6):649-657
亲水作用色谱(HILIC)是近年来色谱领域研究的热点之一。本文围绕复杂体系样品中亲水性组分的分离分析,综述了国际上近年 来发展的以HILIC为核心的多种液相色谱联用技术及其应用。简要介绍了HILIC的起源、定义、分离特点及其常用固定相;比较了HILIC和反相色谱(RPLC)的选择特性;针对不同层次的分离对象和分离要求,讨论了多种基于HILIC的液相色谱以及液相色谱-质谱联用技术的分离特点和适用范围。  相似文献   

11.
Micellar liquid chromatography (MLC) is a reversed-phase liquid chromatographic (RPLC) mode with mobile phases containing a surfactant (ionic or non-ionic) above its critical micellar concentration (CMC). In these conditions, the stationary phase is modified with an approximately constant amount of surfactant monomers, and the solubilising capability of the mobile phase is altered by the presence of micelles, giving rise to diverse interactions (hydrophobic, ionic and steric) with major implications in retention and selectivity. From its beginnings in 1980, the technique has evolved up to becoming a real alternative in some instances (and a complement in others) to classical RPLC with hydro-organic mixtures, owing to its peculiar features and unique advantages. This review is aimed to describe the retention mechanisms (i.e. solute interactions with both stationary and mobile phases) in an MLC system, revealed in diverse reports where the retention behaviour of solutes of different nature (ionic or neutral exhibiting a wide range of polarities) has been studied in a variety of conditions (with ionic and non-ionic surfactants, added salt and organic solvent, and varying pH). The theory is supported by several mechanistic models that describe satisfactorily the retention behaviour, and allow the measurement of the strength of solute-stationary phase and solute-micelle interactions. Suppression of silanol activity, steric effects in the packing pores, anti-binding behaviour, retention of ionisable compounds, compensating effect on polarity differences among solutes, and the contribution of the solvation parameter model to elucidate the interactions in MLC, are commented.  相似文献   

12.
This work aims at characterizing interactions between a select set of probes and 22 hydrophilic and polar commercial stationary phases, to develop an understanding of the relationship between the chemical properties of those phases and their interplay with the eluent and solutes in hydrophilic interaction chromatography. "Hydrophilic interaction" is a somewhat inexact term, and an attempt was therefore made to characterize the interactions involved in HILIC as hydrophilic, hydrophobic, electrostatic, hydrogen bonding, dipole-dipole, π-π interaction, and shape-selectivity. Each specific interaction was quantified from the separation factors of a pair of similar substances of which one had properties promoting the interaction mode being probed while the other did not. The effects of particle size and pore size of the phases on retention and selectivity were also studied. The phases investigated covered a wide range of surface functional groups including zwitterionic (sulfobetaine and phosphocholine), neutral (amide and hydroxyl), cationic (amine), and anionic (sulfonic acid and silanol). Principal component analysis of the data showed that partitioning was a dominating mechanism for uncharged solutes in HILIC. However, correlations between functional groups and interactions were also observed, which confirms that the HILIC retention mechanism is partly contributed by adsorption mechanisms involving electrostatic interaction and multipoint hydrogen bonding. Phases with smaller pore diameters yielded longer retention of solutes, but did not significantly change the column selectivities. The particle diameter had no significant effect, neither on retention, nor on the selectivities. An increased water content in the eluent reduced the multipoint hydrogen bonding interactions, while an increased electrolyte concentration lowered the selectivities of the tested columns and made their interaction patterns more similar.  相似文献   

13.
研究了不同流速下4种溶质在两种不同反相色谱柱上的色谱图及它们的动力学色谱性质,进一步验证了溶质相对保留值(RRT)与流动相流速之间存在良好的双对数线性关系,并对溶质在流速改变时洗脱顺序发生改变的现象从动力学因素上进行了合理的解释;同时还发现色谱填料的孔径及拓扑学构型不同将导致溶质在其上具有不同的动力学色谱参数及动力学色谱行为。  相似文献   

14.
Poly(ionic liquid)‐modified stationary phases can have multiple interactions with solutes. However, in most stationary phases, separation selectivity is adjusted by changing the poly(ionic liquid) anions. In this work, two poly(ionic liquid)‐modified silica stationary phases were prepared by introducing the cyano or tetrazolyl group on the pendant imidazolium cation on the polymer chains. Various analytes were selected to investigate their mechanism of retention in the stationary phases using different mobile phases. Two poly(ionic liquid)‐modified stationary phases can provide various interactions toward solutes. Compared to the cyano‐functionalized poly(ionic liquid) stationary phase, the tetrazolyl‐functionalized poly(ionic liquid) stationary phase provides additional cation‐exchange and π‐π interactions, resulting in different separation selectivity toward analytes. Finally, applicability of the developed stationary phases was demonstrated by the efficient separation of nonsteroidal anti‐inflammatory drugs.  相似文献   

15.
Comprehensive analytical methods based on pressurized liquid extraction followed by normal-phase liquid chromatography (NPLC) with ultraviolet detection and reversed-phase liquid chromatography (RPLC)/electrospray mass spectrometry (MS) have been developed for determination of alkylphenol ethoxylates (APEOs) in textile samples. NPLC with an aminosilica column allowed for the chromatographic separation of APEOs according to the increasing number of ethylene units and revealed the exact distribution of individual oligomers. RPLC coupled with electrospray MS was highly sensitive and enabled the complete qualitative and quantitative determination of individual APEOs in textile samples. The 2 analytical methods based on different chromatographic separation mechanisms, i.e., NPLC and RPLC, may provide complementary information of APEOs in textile materials. The 2 detection methods were successfully applied to the investigation of various textile samples, and the data of our research suggested actual pollution in real textile products.  相似文献   

16.
17.
L. Szepesy  V. Háda 《Chromatographia》2001,54(1-2):99-108
Summary Eight commercially available reversed-phase (RP) columns of widely different characteristics were evaluated and compared using the linear solvation energy relationships (LSER). Retention factors of 32 solutes of different types were determined under isocratic conditions using an acetonitrile-water (30∶70) mobile phase. Stationary phase properties were compared by the fitting coefficients of the LSER-based regression equations which are characteristic of the individual stationary phases and represent the extent of various molecular interactions contributing to the retention process. The good agreement between the calculated and measured logk values for different type of compounds support the adequacy and applicability of the LSER model to describe chromatographic retention. Characterization of column performance for the separation of various type of compounds was established by the determination of the different selectivity factors representing hydrophobic selectivity, polar selectivity and specific selectivity.  相似文献   

18.
Summary A thermodynamic equation is derived for the non-specific selectivity of alkyl bonded phases as a function of the mobile phase composition using a displacement mechanism to model the sorption of solvents into the bonded phase. The equation is used to calculate the thermodynamic parameters which characterize the incremental behavior of a hydrophobic group in ethyl alkanoate and methyl perfluoroalkanoate ester solutes chromatographed with water-methanol and water-acetonitrile mobile phases on both octyl and octadecyl bonded phases.  相似文献   

19.
亲水作用色谱是一种新型的色谱分离模式.此类色谱模式集反相色谱的经济廉价与正相色谱的优点于一体,有效补充了反相色谱的不足.简单介绍实验室中合成的新型亲水色谱固定相.  相似文献   

20.
The design of a new interface to hyphen high efficiency supercritical fluid chromatography (SFC) and fast RPLC in a comprehensive configuration is described. SFC x RPLC is a viable alternative to normal phase (NP) LC x RPLC and is characterized by high orthogonality. Compared to NPLC x RPLC an additional advantage is the expansion of supercritical carbon dioxide (CO(2)) when exposed to atmospheric pressure leading to fractions consisting of solvents that are miscible with the second dimension RPLC mobile phase. The interface consists of a two-position/ten-port switching valve equipped with two packed octadecyl silica (C(18)) loops for effective trapping and focusing of the analytes after elution from the SFC dimension. The addition of a water make-up flow to the SFC effluent prior to entering the loops is of fundamental importance to efficiently focus the solutes on the C(18) material and to reduce interferences of expanded CO(2) gas on the second dimension separation. The features of the system are illustrated with the analysis of a lemon oil sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号