首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Four novel nonionic polar stationary phases were synthesised by anchoring first 2-mercaptoethanol and 1-thioglycerol, respectively, onto vinylised silica (ME and TG packings) followed by an on-phase oxidation with excess hydrogen peroxide in aqueous medium which yielded sulphoxide analogues of the embedded sulphide groups, i. e. oxidised 2-mercaptoethanol (MEO) and oxidised 1-thioglycerol (TGO) packings. Chromatographic characteristics of these stationary phases were evaluated comparatively to three commercial so-called 'diol' columns. U-shaped response curves of retention factors of adenosine and guanosine with hydro-organic eluents containing 5-95% v/v ACN as well as noticeable CH(2)-increment selectivity demonstrated multimodal separation capabilities of the developed amphiphilic materials, i. e. columns can be operated both in hydrophilic interaction chromatography (HILIC) and in RP mode. Although the selector ligands were physico-chemically related, considerably differing retention and selectivity patterns were observed in the HILIC mode. Thereby the introduction of additional hydroxyl groups in the chromatographic ligand resulted in selectivity increments that were different from those obtained by sulphur oxidation. For example, a set of five vitamins delivered five different elution orders with the overall seven columns. A close examination of HILIC separations of nucleobases and nucleosides on the developed packings revealed that (i) the amount of ACN in the eluent adopts a pivotal role in adjusting retention, (ii) the linearity of the relationship log (retention factor) versus log (volume fraction of water in the eluent) increases with phase polarity in the range of 5-40% v/v water, (iii) the slopes are higher with solutes having more polar interactive sites, (iv) the van't Hoff plots are linear (range 15-45 degrees C) with negative retention enthalpy values DeltaH (-4.5 to -14.5 kJ/mol) and (v) the -DeltaH values tend to be higher with more polar phases and more polar analytes. Based on these data the HILIC retention mechanism is described to be composed of both partitioning and adsorption processes. Distinct types of polar interactive sites in the chromatographic ligands may generate mixed-mode HILIC separation conditions that may additionally be superimposed by surface silanol contributions.  相似文献   

2.
This work aims at characterizing interactions between a select set of probes and 22 hydrophilic and polar commercial stationary phases, to develop an understanding of the relationship between the chemical properties of those phases and their interplay with the eluent and solutes in hydrophilic interaction chromatography. "Hydrophilic interaction" is a somewhat inexact term, and an attempt was therefore made to characterize the interactions involved in HILIC as hydrophilic, hydrophobic, electrostatic, hydrogen bonding, dipole-dipole, π-π interaction, and shape-selectivity. Each specific interaction was quantified from the separation factors of a pair of similar substances of which one had properties promoting the interaction mode being probed while the other did not. The effects of particle size and pore size of the phases on retention and selectivity were also studied. The phases investigated covered a wide range of surface functional groups including zwitterionic (sulfobetaine and phosphocholine), neutral (amide and hydroxyl), cationic (amine), and anionic (sulfonic acid and silanol). Principal component analysis of the data showed that partitioning was a dominating mechanism for uncharged solutes in HILIC. However, correlations between functional groups and interactions were also observed, which confirms that the HILIC retention mechanism is partly contributed by adsorption mechanisms involving electrostatic interaction and multipoint hydrogen bonding. Phases with smaller pore diameters yielded longer retention of solutes, but did not significantly change the column selectivities. The particle diameter had no significant effect, neither on retention, nor on the selectivities. An increased water content in the eluent reduced the multipoint hydrogen bonding interactions, while an increased electrolyte concentration lowered the selectivities of the tested columns and made their interaction patterns more similar.  相似文献   

3.
张静  王玲玲  单联国  卫引茂 《色谱》2012,30(8):804-809
用硅胶与氨丙基三甲氧基硅烷反应,再与δ-葡萄糖酸内酯反应,制备了一种多羟基化合物键合的新型亲水色谱固定相。以水-有机溶剂(乙醇、乙腈、四氢呋喃)为流动相,通过改变流动相中有机溶剂的种类及浓度、缓冲盐浓度和柱温,考察了该固定相对6种强极性中药组分的保留行为和保留机理。当水的比例在0~40%(v/v)范围时,溶质的保留随着流动相中水的比例的增大而减小,属于典型的亲水色谱分离模式;而当流动相中水的比例在0~100%(v/v)范围内变化时,溶质的保留随着水的比例变化呈“U”形曲线,属于亲水色谱和反相色谱的混合保留机理。缓冲盐的浓度和pH效应说明,所选用的中药组分与所制备的固定相间还存在弱的静电作用。该固定相对6种中药组分以及丹参注射液具有良好的分离性能,表明其在强极性中药有效成分的分离及其他强极性物质的分离分析中具有一定的应用前景。  相似文献   

4.
Hydrophilic interaction chromatography (HILIC) is becoming increasingly popular for separation of polar samples on polar columns in aqueous-organic mobile phases rich in organic solvents (usually ACN). Silica gel with decreased surface concentration of silanol groups, or with chemically bonded amino-, amido-, cyano-, carbamate-, diol-, polyol-, or zwitterionic sulfobetaine ligands are used as the stationary phases for HILIC separations, in addition to the original poly(2-sulphoethyl aspartamide) strong cation-exchange HILIC material. The type of the stationary and the composition of the mobile phase play important roles in the mixed-mode HILIC retention mechanism and can be flexibly tuned to suit specific separation problems. Because of excellent mobile phase compatibility and complementary selectivity to RP chromatography, HILIC is ideally suited for highly orthogonal 2-D LC-LC separations of complex samples containing polar compounds, such as peptides, proteins, oligosaccharides, drugs, metabolites and natural compounds. This review attempts to present an overview of the HILIC separation systems, possibilities for their characterization and emerging HILIC applications in 2-D off-line and on-line LC-LC separations of various samples, in combination with RP and other separation modes.  相似文献   

5.
Two polysaccharide stationary phases have been newly suggested for application in hydrophilic interaction chromatography (HILIC). Both columns (amylose‐silica, 250 × 4.6 mm, 5 μm and cellulose‐silica, 250 × 4.6 mm, 5 μm) demonstrated a satisfactory retention of polar compounds. The influence of the mobile‐phase composition (acetonitrile content, pH, salt concentration) on the retention was in agreement with the HILIC concept. The phases showed a very similar behavior, typical efficiency of about 50 000 plates/m, cellulose retained test compounds somewhat more strongly. Under the experimental conditions, electrostatic (non‐HILIC‐type) interactions due to the dissociation of silanol groups on the silica surface did not influence the retention, noticeably. The applicability of polysaccharide stationary phases for the chromatography of polar compounds was proven by the separation of mixtures of sugars (fructose, glucose, saccharose, maltose, trehalose) or vitamins (nicotinamide, pyridoxine, riboflavin, thiamine, nicotinic acid, ascorbic acid).  相似文献   

6.
Acetonitrile–water extracts of several Ganoderma species – a mushroom being used in Traditional Chinese Medicine – were analysed by liquid chromatography–UV detection in hydrophilic interaction chromatography (HILIC) and reversed-phase (RP) elution modes. A set of six polar stationary phases was used for HILIC runs. These columns had remarkably different separation properties under binary gradient conditions as evinced by hierarchical cluster analysis on retention patterns of seven test compounds. Complementary measurements of RP chromatograms were carried out on a C18 packing. Injection precision (n = 5) and intra-day precision (n = 5) were each <2.0% RSD (HILIC) and <0.7% RSD (RP) for relative retention times of main characteristic peaks of a sample extract while for relative peak areas RSD values were max. 6.8%. Repetitive analysis (n = 7) of a processed sample stored in the autosampler tray for 48 h was used to confirm within-sequence sample stability. Eleven Ganoderma lucidum samples served as training set for the construction of column-specific simulated mean chromatograms. Validation with twelve samples comprising G. lucidum, Ganoderma sinense, Ganoderma atrum, and Ganoderma tsugae by correlation coefficient based similarity evaluation of peak patterns showed that a discrimination of G. lucidum from other Ganoderma species by means of chromatographic fingerprints is conceptually possible on all columns, except of a bare silica packing. The importance of the combined use of RP and HILIC fingerprints to improve the rate of correct sample classification was demonstrated by the fact that each one G. sinense specimen was wrongly assigned being G. lucidum by all HILIC fingerprints but not the RP fingerprint and vice versa. The present data revealed that (i) the analysis of complex biological materials by quasi orthogonal chromatographic modes such as HILIC and RP may deliver more discriminative information than single-mode approaches which strengthens the reliability of fingerprint-based sample classification and (ii) different retention and selectivity characteristics of polar bonded silica packings in the HILIC elution mode may only have a minor impact on chemometric sample discrimination capabilities in such kind of pattern-oriented metabolomics separation problems.  相似文献   

7.
In this work, a revisit to the retention mechanism of HILIC was attempted to point out critical factors that contribute to the chromatographic regime as well as to bring out subtle details of the relative contribution of partitioning and surface adsorption. In this vein, the retention behaviour of a set of water-soluble vitamins (WSVs) and toluene on three silica based columns was evaluated under varying chromatographic conditions. The data obtained were associated with the hydration degree of the stationary phases and the ability of the organic solvents to disrupt the formation of the water-enriched layer. Moreover, the elution behaviour of toluene at different buffer salt concentrations in the mobile phase, confirmed the preferential partition of salt ions into the stagnant layer, as ACN content was increased. The results from the fitting of partitioning and surface adsorption models indicated differences in the contribution of the two retention mechanisms to both neutral and charged compounds. The occurrence of surface adsorption and the retentivity differences for neutral WSVs depend on the hydration degree and the hydrogen bonding properties of the solutes and the column surface, respectively. For charged solutes experiencing electrostatic repulsion, the contribution of the adsorption mechanism at highly organic mobile phases, emanates from both the weak effect of buffer salt ions on the electrostatic interaction and the strong effect of hydrophilic interactions. On the other hand, the chromatographic retention of electrostatically attracted solutes indicates that the surface adsorption dominates, even at mobile phases rich in water.  相似文献   

8.
Ultra-performance liquid chromatography (UPLC) in reversed-phase (RP), ion pair (IP) and hydrophilic interaction chromatography (HILIC) has been investigated for the separation of imidazolium-based ionic liquid (IL) cations. Among the three stationary phases (i.e., C18, C8 and phenyl) studied under RP conditions the phenyl phase provided much stronger retention for the IL cations. Four acids (hydrochloric, methanesulfonic, perchloric and trifluoroacetic) as mobile phase additives were compared in light of their effects on the retention of IL cations. It was shown that the retention of all IL cations decreased upon acidification of the mobile phase, possibly due to suppression of residual silanol ionization. Very fast (~3 min) and efficient RP-UPLC separation of six cations was achieved by gradient elution with acetonitrile?Cwater mobile phase containing 2.5 mmol L?1 perchloric acid. In IP-UPLC all solutes were well resolved in about 4 min by gradient elution with acetonitrile?Cwater mobile phase containing 1 mmol L?1 sodium 1-octanesulfonate as ion pairing reagent. Finally, under HILIC conditions by using isocratic elution with acetonitrile?Cwater (85:15, v/v) mobile phase containing 5 mmol L?1 ammonium formate (pH 3.2) the separation time was reduced to less than 2 min while maintaining excellent peak shapes and sufficient resolution. Compared to current LC systems UPLC allowed considerably faster separations with better peak shapes.  相似文献   

9.
Summary A new bonded phase containing both non-polar C8 and polar polyglycol chains was synthesized in two steps. Silica was first silanized with octyltrimethoxysilane and then the intermediate product was reacted with tetraethylene glycol to introduce the polar group. The bonded phase exhibits a selectivity different from that of C8 or C18 reversed phases with a mixed-mode retention mechanism. The silanol effect on the polyglycol-C8 bonded phase was examined with the test mixture proposed by Engelhardt and co-workers. The experimental results indicate that the new bonded phase displays less silanol effect. The observed tailing of some ionizable species resulted mainly from their partial dissociation at the pH values of eluents close to thepK a values of the solutes. Some potential applications of the bonded phase are also given.  相似文献   

10.
Correspondence factor analysis (CFA) was employed to study the selectivity of 14 HPLC systems. The tested LC systems were classified as reversed-phase (RP), ion-exchange (IE) and hydrophilic interaction chromatography (HILIC) modes. It was found that the retentions of the hydrophilic solutes on HILIC column were significantly influenced by the second-order effects besides their hydrophilic properties. Organic modifiers and residue silanol groups on silica surface both participated in retention. HypersilTM amino column performed separation in the HILIC mode at appropriate conditions, and its retention mechanism was more similar to that of HILIC silica column than that of HILIC column coating poly(aspartamide) groups.  相似文献   

11.
Chromatographic effects of dedicated stationary and mobile phase variations in hydrophilic interaction chromatography (HILIC) were investigated using a set of nucleobases, nucleosides and deoxynucleosides as polar test solutes. Retention and selectivity profiles were comparatively mapped on four in-house developed silica materials modified with short alkyl chains (C4, C5) which carry hydroxyl functionalities (including diol motifs) as well as embedded sulphide or sulphoxide groups. These data were complemented by results obtained with two commercially available diol-type phases and a bare silica column. Besides elucidation of packing-related aspects this work concentrated specifically on extending aqueous HILIC (AQ-HILIC) to nonaqueous polar-organic elution conditions herein termed NA-HILIC. The exchange of the polar modifier water by various alcohols in ACN-rich mobile phases containing 5 mM ammonium acetate decreased the eluotropic strength of the resulting eluents. The gain in retention largely followed the order ethanol (EtOH)>methanol (MeOH)>1,2-ethanediol (Et(OH)2) and was accompanied by distinct effects on chromatographic selectivity. For example, on the most polar home-made packing the purine nucleoside selectivity guanosine/adenosine increased from 2.25 in the AQ-HILIC (kguanosine=8.3) to 7.33 (kguanosine=59) in the NA-HILIC mode when EtOH was employed as NA modifier while this value was 5.84 and 2.93 with MeOH and Et(OH)2, respectively (eluent: 5 mM ammonium acetate in ACN/modifier 90:10 v/v). Besides the type of protic modifier its percentage as well the retention and selectivity effects upon varying the ammonium acetate concentration and column temperature, respectively, were also investigated. Notable inter-column differences were found for all of these elution parameters. A mixed-mode retention model composed of partitioning and adsorption is proposed for both AQ- and NA-HILIC retention processes. The potential of (i) the implementation of novel polar bondings (such as ones containing sulphoxide functionalities) and (ii) the comprehensive exploitation of elution variables (type of protic modifiers, salt, etc.) for providing new selectivity increments to the separation of polar analytes in HILIC is emphasised.  相似文献   

12.
成晓东  张铮 《应用化学》2019,36(6):726-732
利用异氰酸丙基三乙氧基硅烷与L-异亮氨酸反应合成了一种新型的硅烷偶联剂,并进一步将其与硅胶反应制得键合有L-异亮氨酸的亲水色谱固定相。 通过核磁共振氢谱表明亮氨酸功能化硅烷偶联剂的成功合成、元素分析表征证明亮氨酸已成功键合到硅胶表面。 将其作为亲水模式下的固定相填料填装在150 mm×4.6 mm不锈钢色谱柱中,以一系列经典的极性小分子作为探针,考察了这些探针分子在固定相上的色谱行为。 极性化合物的保留时间随着流动相中有机溶剂含量提高而逐渐增大,表现出典型的亲水保留特征。 进一步研究了流动相中乙腈含量、缓冲盐pH值及缓冲盐浓度等因素对分析物在固定相上的保留的影响。 在优化了相关参数后,将固定相应用于碱性化合物、水溶性维生素以及核苷类极性物质的分离当中。 在等度洗脱下,5种碱性化合物、6种水溶性维生素和8种核苷类物质分别在8、18及25 min内被成功分离。 分离结果表明了合成的L-异亮氨酸键合亲水色谱固定相具有较好的色谱性能,在极性化合物的分离上具有良好的应用前景。  相似文献   

13.
Hydrophilic interaction chromatography (HILIC) is valuable alternative to reversed-phase liquid chromatography separations of polar, weakly acidic or basic samples. In principle, this separation mode can be characterized as normal-phase chromatography on polar columns in aqueous-organic mobile phases rich in organic solvents (usually acetonitrile). Highly organic HILIC mobile phases usually enhance ionization in the electrospray ion source of a mass spectrometer, in comparison to mobile phases with higher concentrations of water generally used in reversed-phase (RP) LC separations of polar or ionic compounds, which is another reason for increasing popularity of this technique. Various columns can be used in the HILIC mode for separations of peptides, proteins, oligosaccharides, drugs, metabolites and various natural compounds: bare silica gel, silica-based amino-, amido-, cyano-, carbamate-, diol-, polyol-, zwitterionic sulfobetaine, or poly(2-sulphoethyl aspartamide) and other polar stationary phases chemically bonded on silica gel support, but also ion exchangers or zwitterionic materials showing combined HILIC-ion interaction retention mechanism. Some stationary phases are designed to enhance the mixed-mode retention character. Many polar columns show some contributions of reversed phase (hydrophobic) separation mechanism, depending on the composition of the mobile phase, which can be tuned to suit specific separation problems. Because the separation selectivity in the HILIC mode is complementary to that in reversed-phase and other modes, combinations of the HILIC, RP and other systems are attractive for two-dimensional applications. This review deals with recent advances in the development of HILIC phase separation systems with special attention to the properties of stationary phases. The effects of the mobile phase, of sample structure and of temperature on separation are addressed, too.  相似文献   

14.
高效液相色谱槲皮素键合硅胶固定相分离极性化合物   总被引:1,自引:0,他引:1  
槲皮素是一种植物体中含量丰富、价格较便宜的黄酮类化合物,本研究以γ-[(2,3)-环氧丙氧]丙基三甲氧基硅烷(KH-560)为偶联剂,将其化学键合到硅胶上,得到一种含天然配体的槲皮素键合硅胶固定相(QUSP)。 采用红外光谱、热重分析、元素分析及固体核磁对其结构进行表征,测得硅胶表面槲皮素的键合量为0.139 mmol/g。 采用不同结构的溶质作探针,在评价固定相反相液相色谱疏水作用性能的基础上,侧重研究新固定相对极性芳香族化合物的分离能力,探讨了新固定相的色谱分离机理。 研究表明,仅采用甲醇或乙腈-水简单流动相,无需用缓冲液精确控制pH值,QUSP就能分别实现吡啶类、芳胺类、苯酚类、苯甲酸类和黄酮类等极性化合物的快速基线分离。 QUSP键合的槲皮素除含疏水性的C6-C3-C6骨架外,黄酮环还能为溶质提供氢键、偶极、π-π、电荷转移等多种作用位点,各种协同作用有利于提高色谱分离选择性,尤其对极性的可离子化的酸性和碱性化合物。  相似文献   

15.
We prepared hybrid particle-monolithic polymethacrylate columns for micro-HPLC by in situ polymerization in fused silica capillaries pre-packed with 3–5 μm C18 and aminopropyl silica bonded particles, using polymerization mixtures based on laurylmethacrylate–ethylene dimethacrylate (co)polymers for the reversed-phase (RP) mode and [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl) zwitterionic (co)polymers for the hydrophilic interaction (HILIC) mode. The hybrid particle-monolithic columns showed reduced porosity and hold-up volumes, approximately 2–2.5 times lower in comparison to the pure monolithic columns prepared in the whole volume of empty capillaries. The elution volumes of sample compounds are also generally lower in comparison to packed or pure monolithic columns. The efficiency and permeability of the hybrid columns are intermediate in between the properties of the reference pure monolithic and particle-packed columns. The chemistries of the embedded solid particles and of the interparticle monolithic moiety in the hybrid capillary columns contribute to the retention to various degrees, affecting the selectivity of separation. Some hybrid columns provided improved separations of proteins in comparison to the reference particle-packed columns in the reversed-phase mode. Zwitterionic hybrid particle-monolithic columns show dual mode retention HILIC/RP behaviour depending on the composition of the mobile phase and allow separations of polar compounds such as phenolic acids in the HILIC mode at lower concentrations of acetonitrile and, often in shorter analysis time in comparison to particle-packed and full-volume monolithic columns.  相似文献   

16.
The separation and retention behavior of five aromatic carboxylic acid isomers was investigated by means of high-performance liquid chromatography (HPLC) using a β-cyclodextrin bonded phase with s-triazine ring in the spacer. The influence of mobile phase pH on the retention was examined. The presence of s-triazine moiety in the spacer enhances greatly the selectivity of the isomers of aromatic carboxylic acids. Baseline separations of the five aromatic carboxylic acid isomers were achieved. In particular, the isomers of toluic, aminobenzoic, nitrobenzoic and hydroxybenzoic acid were successfully and effectively separated. The chromatographic results indicate that, in addition to inclusion complexation, π-π interaction and hydrogen bonding interaction between the bonded phase and analytes play significant roles in the retention of these acid isomers. Different elution orders were observed for these acidic solutes with different substituents. Possible retention mechanisms are discussed.  相似文献   

17.
Novel saccharide-based stationary phases were developed by applying non-enzymatic browning (Maillard Reaction) on aminopropyl silica material. During this process, the reducing sugars glucose, lactose, maltose, and cellobiose served as “ligand primers”. The reaction cascade using cellobiose resulted in an efficient chromatographic material which further served as our model Chocolate HILIC column. (Chocolate refers to the fact that these phases are brownish.) In this way, an amine backbone was introduced to facilitate convenient manipulation of selectivity by additional attractive or repulsive ionic solute–ligand interactions in addition to the typical HILIC retention mechanism. In total, six different test sets and five different mobile phase compositions were investigated, allowing a comprehensive evaluation of the new polar column. It became evident that, besides the so-called HILIC retention mechanism based on partition phenomena, additional adsorption mechanisms, including ionic interactions, take place. Thus, the new column is another example of a HILIC-type column characterized by mixed-modal retention increments. The glucose-modified materials exhibited the relative highest overall hydrophobicity of all grafted Chocolate HILIC columns which enabled retention of lipophilic analytes with high water content mobile phases.  相似文献   

18.
In this report, a novel polar monolithic capillary column is described for normal phase CEC (NP-CEC) of representative polar compounds including mono- and oligosaccharides, peptides, and basic drugs. The polar monolithic column, which was described in detail in the preceding paper, consisted of silica-based monolith bonded with 1H-imidazole-4,5-dicarbonitrile (IDCN) and is denoted as 2CN-OH-Monolith. Various retention parameters for neutral polar solutes (e.g., mono- and oligosaccharides) and charged polar solutes (e.g., peptides and basic drugs) were evaluated over a wide-range of elution conditions. These retention parameters yielded quantitative assessment for the polar interactions between the model solutes and the stationary phase under investigation as well as the effect of electromigration of charged solutes on their overall migration in NP-CEC. Furthermore, this investigation demonstrated that despite the possibility of achieving isocratic separation in NP-CEC for widely differing polar species, multistep-gradient elution in NP-CEC is preferred to bring about the rapid separation of a large number of polar species in a single run.  相似文献   

19.
Monolithic silica capillary columns for hydrophilic interaction liquid chromatography (HILIC) were prepared by on-column polymerization of acrylic acid on monolithic silica in a fused silica capillary modified with anchor groups. The products maintained the high permeability (K=5 x 10(-14)m(2)) and provided a plate height (H) of less than 10 microm at optimum linear velocity (u) and H below 20 microm at u=6mm/s for polar solutes including nucleosides and carbohydrates. The HILIC mode monolithic silica capillary column was able to produce 10000 theoretical plates (N) with column dead time (t(0)) of 20s at a pressure drop of 20 MPa or lower. The total performance was much higher than conventional particle-packed HILIC columns currently available. The gradient separations of peptides by a capillary LC-electrospray mass spectrometry system resulted in very different retention selectivity between reversed-phase mode separations and the HILIC mode separations with a peak capacity of ca. 100 in a 10 min gradient time in either mode. The high performance observed with the monolithic silica capillary column modified with poly(acrylic acid) suggests that the HILIC mode can be an alternative to the reversed-phase mode for a wide range of compounds, especially for those of high polarity in isocratic as well as gradient elution.  相似文献   

20.
以甲基丙烯酰氧乙基二甲基乙酸铵(CBMA)为功能单体,利用表面引发原子转移自由基聚合(Surface-initiated atom transfer radical polymerization, SI-ATRP)技术,将CBMA接枝到硅胶表面,得到接枝聚合物CBMA的亲水作用色谱固定相(Silica-CBMA).通过改变SI-ATRP反应体系中单体的浓度,制备了3种不同接枝量的亲水作用色谱固定相.考察了Silica-CBMA固定相对有机酸类化合物的分离性能以及流动相中pH值、盐浓度、水含量等因素对溶质保留行为的影响.结果表明,在亲水作用色谱模式下,Silica-CBMA固定相对有机酸类化合物的分离是离子交换作用与亲水作用的混合色谱模式.流动相中盐浓度增大,溶质保留减弱,符合离子交换作用特征;固定相和溶质的离子化程度受流动相pH值影响较大,pH值增大,溶质保留增强;而溶质的保留时间随流动相水含量增加而降低则是典型的亲水作用色谱特征.使用自制Silica-CBMA柱,建立了芦丁片中维生素C、芦丁含量的亲水作用色谱测定方法,操作方法简单,为强极性样品的分离测定提供了新方法.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号