首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Lab‐on‐a‐chip provides an ideal platform for short tandem repeat (STR) genotyping due to its intrinsic low sample consumption, rapid analysis, and high‐throughput capability. One of the challenges, however, in the forensic human identification on the microdevice is the detection sensitivity derived from the nanoliter volume sample handling. To overcome such a sensitivity issue, here we developed a sample stacking CE microdevice for mini Y STR genotyping. The mini Y STR includes redesigned primer sequences to generate smaller‐sized PCR amplicons to enhance the PCR efficiency and the success rate for a low copy number and degraded DNA. The mini Y STR amplicons occupied in the 5‐ and 10‐mm stacking microchannels are preconcentrated efficiently in a defined narrow region through the optimized sample stacking CE scheme, resulting in more than tenfold improved fluorescence peak intensities compared with that of a conventional cross‐injection microcapillary electrophoresis method. Such signal enhancement allows us to successfully analyze the Y STR typing with only 25 pg of male genomic DNA, with high background of female genomic DNA, and with highly degraded male genomic DNA. The combination of the mini Y STR system with the novel sample stacking CE microdevice provides the highly sensitive Y STR typing on a chip, making it promising to perform high‐performance on‐site forensic human identification.  相似文献   

2.
As one genotyping method for Mycobacterium tuberculosis, variable number of tandem repeats (VNTR) is a promising tool to trace the undefined transmission of tuberculosis, but it often requires large equipment such as a genetic analyzer for DNA fragment analysis or CE system to conduct systematic analyses. For convenient genotyping at low cost in laboratories, we designed a multiplex PCR system that is applicable to agarose gel electrophoresis using fluorescent PCR primers. For tuberculosis genotyping by VNTR, the copy quantities of minisatellite DNA must be determined in more than 12 loci. The system can halve laborious electrophoresis processes by presenting an image of two VNTR amplicons on a single lane. No expensive equipment is necessary for this method. Therefore, it is useful even in developing countries.  相似文献   

3.
A variable number of tandem repeat (VNTR) polymorphism within the intron 36 of the human mucin gene MUC5B, which is mapped to chromosome 11 band p15.5, have been identified using Southern blotting experiments. This polymorphism can be easily assayed by polymerase chain reaction (PCR) to detect linkage of inherited disorder. Five alleles were observed in 86 unrelated individuals due to 3-8 direct perfect repeats of 59 bp. This repeat has the particularity to begin at the end of the preceding exon. Southern blot experiments revealed the locus specificity of the repeat. The sequence of the repeat unit does not match the consensus sequence of Chi-related minisatellites.  相似文献   

4.
Issue no. 12 is a regular issue consisting of 18 contributions distributed over 4 distinct parts: Part I is on protein and proteomics methodologies containing 6 research articles dealing with new fluorescent probe for gel electrophoresis of proteins, treatment of serum samples with combinatorial library beads, glycoproteomics analysis of haptoglobin multimers, micropreparative isoelectric focusing in a suspended drop, and 2‐DE and MALDI‐TOF‐MS analysis of the therapeutic protein abatacept; Part II has 4 contributions on various approaches of genotyping; Part III treats on‐line concentration and sensitivity enhancement of angiotensins and pyridine‐triphenylborane and its degradation products; Part IV has 6 contributions on some aspects of fundamentals and methodologies involving EMMA, effects of carbon dioxide in CE at high pH, particle sorting by dielectrophoresis, CE‐electrochemiluminescence with ionic liquid, enantioseparation by monolithic imprinted capillary clamped in a chip, and infrared‐based temperature measurements in CE. In summary, issue no. 12 covers many important subjects in the field. Featured articles include: Design and synthesis of new fluorescent probe for rapid and highly sensitive detection of proteins via electrophoretic gel stain (( 10.1002/elps.201000691 )) Glycoproteomic analysis and molecular modeling of haptoglobin multimers (( 10.1002/elps.201000464 )) PCR‐free digital minisatellite tandem repeat genotyping (( 10.1002/elps.201000073 )) A dielectrophoretic continuous flow sorter using integrated microelectrodes coupled to a channel constriction (( 10.1002/elps.201000675 ))  相似文献   

5.
We describe an efficient and simple minisatellite variant repeat mapping by PCR (MVR-PCR) method based on the assignment of the tandem array of 29 bp repeating units into a-type, t-type and 0-type (a rarely appearing unamplified unit), from the first repeat unit position (code position 0) of 293 bp in D1S8 locus. After microchip electrophoresis of PCR product amplified from the target DNA of a human hair root, each rung of the ladder at the position of 293 + 29 n bp (n: code position) was detected and the type of repeating unit was determined, i.e., aa, a0, tt, t0, at and 00. The peak area of the rungs from PCR product decreased with increase in code position. We found for the first time that the logarithmic plots of the peak area against the code position showed a linear relationship, which implied that peak areas decrease exponentially. The present method was successfully applied to identify 37 individuals using only a hair root as a biological specimen. This "exponential law" is expected to be an effective tool in forensic science.  相似文献   

6.
Lee JC  Tsai LC  Liao SP  Linacre A  Hsieh HM 《Electrophoresis》2010,31(23-24):3889-3894
We report on the polymorphisms exhibited by three hypervariable regions within the D-loop of Columba livia (pigeon) mitochondrial DNA. A total of 131 samples were taken from 131 randomly selected birds and used in the analyses of SNPs, a variable number of tandem repeats (VNTR) and an STR locus using CE. The number of repeats for the VNTR ranged from 2 to 8 producing 21 haplotypes, with 54 individuals exhibiting heteroplasmy. The STR locus exhibited multiple and continuous repeats within each individual and these patterns were not reproducible with individuals of the same maternal lineage, where different haplotypes were noted. Combining the SNP and VNTR loci produced 38 haplotypes, with the power of discrimination being 0.93. The polymorphic regions of D-loop observed in this study are potential markers for maternal relationship identification.  相似文献   

7.
《Electrophoresis》2018,39(12):1466-1473
Massively parallel sequencing (MPS) technologies, also termed as next‐generation sequencing (NGS), are becoming increasingly popular in study of short tandem repeats (STR). However, current library preparation methods are usually based on ligation or two‐round PCR that requires more steps, making it time‐consuming (about 2 days), laborious and expensive. In this study, a 16‐plex STR typing system was designed with fusion primer strategy based on the Ion Torrent S5 XL platform which could effectively resolve the above challenges for forensic DNA database‐type samples (bloodstains, saliva stains, etc.). The efficiency of this system was tested in 253 Han Chinese participants. The libraries were prepared without DNA isolation and adapter ligation, and the whole process only required approximately 5 h. The proportion of thoroughly genotyped samples in which all the 16 loci were successfully genotyped was 86% (220/256). Of the samples, 99.7% showed 100% concordance between NGS‐based STR typing and capillary electrophoresis (CE)‐based STR typing. The inconsistency might have been caused by off‐ladder alleles and mutations in primer binding sites. Overall, this panel enabled the large‐scale genotyping of the DNA samples with controlled quality and quantity because it is a simple, operation‐friendly process flow that saves labor, time and costs.  相似文献   

8.
We used the variable number tandem repeat (VNTR) polymorphism and the ten short tandem repeat (STR) polymorphisms to study a number of disputed paternity cases in the Japanese population. For the determination of VNTR locus (D1S80) and the ten STR loci (vWA, F13B, TH01, TPOX, CSF1PO, F13A01, LPL, D3S1744, D12S1090, D18S849) we used polymerase chain reaction (PCR) amplification and the vertical polyacrylamide gel electrophoresis technique followed by SYBR green I staining. The irregular repeats were analyzed by sequencing from bands of vertical polyacrylamide gel electrophoresis using the latest gene analyzing equipment, the ABI PRISM 310 Genetic Analyzer. The probable genotypes of the deceased putative father were deduced by Komatu's method from the genotypes of the widow and the genotypes of their children. The calculation of paternity probability used the Essen-Moller formula and Bayes's theorem. Calculated in eleven loci, the distinguishing probabilities (DP) and the mean exclusion chance (MEC) were 0.9999 and 0.9989, respectively. Therefore, information obtained from eleven DNA polymorphisms is enough to determine paternity plausibility.  相似文献   

9.
A fully integrated microdevice and process for forensic short tandem repeat (STR) analysis has been developed that includes sequence-specific DNA template purification, polymerase chain reaction (PCR), post-PCR cleanup and inline injection, and capillary electrophoresis (CE). Fragmented genomic DNA is hybridized with biotin-labeled capture oligos and pumped through a fluidized bed of magnetically immobilized streptavidin-coated beads in microchannels where the target DNA is bound to the beads. The bead-DNA conjugates are then transferred into a 250 nL PCR reactor for autosomal STR amplification using one biotin and one fluorescence-labeled primer. The resulting biotin-labeled PCR products are electrophoretically injected through a streptavidin-modified capture gel where they are captured to form a concentrated and purified injection plug. The thermally released sample plug is injected into a 14 cm long CE column for fragment separation and detection. The DNA template capture efficiency provided by the on-chip sequence-specific template purification is determined to be 5.4% using K562 standard DNA. This system can produce full 9-plex STR profiles from 2.5 ng input standard DNA and obtain STR profiles from oral swabs in about 3 hours. This fully integrated microsystem with sample-in-answer-out capability is a significant advance in the development of rapid, sensitive, and reliable micro-total analysis systems for on-site human identification.  相似文献   

10.
Minisatellites are tandem repeat arrays of middle size (5-100 bp) repeat units widely distributed in eukaryotic genomes. They have been related to several important features of human genome biology, including gene regulation, chromosomal fragile sites, and imprinting. In this report, we have critically assessed and employed heteroduplex analysis (HA) for the identification of different human minisatellite MsH43 alleles. This minisatellite is organized as a repeat array of 5-6 bp units spanning 0.5 kbp. Our results demonstrate that this procedure is an easy, rapid, and reliable method to document allelic diversity for this locus. This work suggests that HA will also be a useful tool for studying the polymorphism of other minisatellites with small repeat units.  相似文献   

11.
《Electrophoresis》2017,38(3-4):513-520
For the development of clinically useful genotyping methods for SNPs, accuracy, simplicity, sensitivity, and cost‐effectiveness are the most important criteria. Among the methods currently being developed for SNP genotyping technology, the ligation‐dependent method is considered the simplest for clinical diagnosis. However, sensitivity is not guaranteed by the ligation reaction alone, and analysis of multiple targets is limited by the detection method. Although CE is an attractive alternative to error‐prone hybridization‐based detection, the multiplex assay process is complicated because of the size‐based DNA separation principle. In this study, we employed the ligase detection reaction coupled with high‐resolution CE‐SSCP to develop an accurate, sensitive, and simple multiplex genotyping method. Ligase detection reaction could amplify ligated products through recurrence of denaturation and ligation reaction, and SSCP could separate these products according to each different structure conformation without size variation. Thus, simple and sensitive SNP analysis can be performed using this method involving the use of similar‐sized probes, without complex probe design steps. We found that this method could not only accurately discriminate base mismatches but also quantitatively detect 37 SNPs of the tp53 gene, which are used as targets in multiplex analysis, using three‐color fluorescence‐labeled probes.  相似文献   

12.
Butler JM  Buel E  Crivellente F  McCord BR 《Electrophoresis》2004,25(10-11):1397-1412
DNA typing with short tandem repeat (STR) markers is now widely used for a variety of applications including human identification. Capillary electrophoresis (CE) instruments, such as the ABI Prism 310 and ABI 3100 Genetic Analyzers, are the method of choice for many laboratories performing STR analysis. This review discusses issues surrounding sample preparation, injection, separation, detection, and interpretation of STR results using CE systems. Requirements for accurate typing of STR alleles are considered in the context of what future analysis platforms will need to increase sample throughput and ease of use.  相似文献   

13.
Rapid diagnosis of bacterial infection is important for patient management and appropriate therapy during the early phase of bacteria‐induced disease. Among the existing techniques for identifying microbial, CE‐SSCP combined with 16S ribosomal RNA gene‐specific PCR has the benefits of excellent sensitivity, resolution, and reproducibility. However, even though CE‐SSCP can separate PCR products with high‐resolution, multiplex detection and quantification are complicated by primer‐dimer formation and non‐specific amplification. Here, we describe a novel technique for multiplex detection and quantification of pathogens by template‐tagging followed by multiplex asymmetric PCR and subsequent CE‐SSCP. More specifically, we reverse transcribed 16S ribosomal RNAs from seven septicemia‐inducing pathogens, tagged the templates with common end sequences, and amplified them using common primers. The resulting amplicons could be successfully separated by CE‐SSCP and quantified by comparison to an internal standard. This method yielded results that illustrate the potential of this system for diagnosing infectious disease.  相似文献   

14.
An 82-base-pair polymerase chain reaction (PCR) product was amplified from the tetranucleotide short tandem repeat locus within the human tyrosine hydroxylase gene. PCR amplification was carried out using 100 ng of human nuclear DNA obtained from an individual who is homozygotic for the 9.3 allele resulting in a 50.5 kDa amplicon. To generate sufficient material for these investigations, several reactions were pooled and subsequently purified and quantified using UV-vis spectrophotometry. A serial dilution was carried out from a 2 μM stock solution providing solution concentrations down to 5 nM. Measurements were made using hexapole accumulation and gated trapping strategies in a 4.7 Telsa Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) which facilitated detection of the amplicon at the attomole level when electrosprayed from a 5 nM solution with a single acquisition! The signal-to-noise ratio was determined to be 8.3 for the spectrum derived from the 5 nM solution using the magnitude-mode mass spectral peak height for the most abundant charge-state. This remarkable sensitivity for large PCR amplicons will dramatically improve the ability of electrospray ionization mass spectrometry to address important genetic questions for low copy number genes or when the amount of initial template is limited; the latter issue is commonly encountered in DNA forensics. Furthermore, these data represents over 2 orders of magnitude decrease in detection limits over other existing ESI-MS reports concerning PCR products, including those conducted using FTICR-MS.  相似文献   

15.
An 82-base-pair polymerase chain reaction (PCR) product was amplified from the tetranucleotide short tandem repeat locus within the human tyrosine hydroxylase gene. PCR amplification was carried out using 100 ng of human nuclear DNA obtained from an individual who is homozygotic for the 9.3 allele resulting in a 50.5 kDa amplicon. To generate sufficient material for these investigations, several reactions were pooled and subsequently purified and quantified using UV-vis spectrophotometry. A serial dilution was carried out from a 2 microM stock solution providing solution concentrations down to 5 nM. Measurements were made using hexapole accumulation and gated trapping strategies in a 4.7 Telsa Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) which facilitated detection of the amplicon at the attomole level when electrosprayed from a 5 nM solution with a single acquisition! The signal-to-noise ratio was determined to be 8.3 for the spectrum derived from the 5 nM solution using the magnitude-mode mass spectral peak height for the most abundant charge-state. This remarkable sensitivity for large PCR amplicons will dramatically improve the ability of electrospray ionization mass spectrometry to address important genetic questions for low copy number genes or when the amount of initial template is limited; the latter issue is commonly encountered in DNA forensics. Furthermore, these data represents over 2 orders of magnitude decrease in detection limits over other existing ESI-MS reports concerning PCR products, including those conducted using FTICR-MS.  相似文献   

16.
A DNA sample was partially degraded by scalar heat-acid treatments to study the extent of apurinic-apyrimidinic (A-P) lesions produced along the molecule. A CE-UV method allowed us to measure the rate of depurination at pH 5.0 and 70°C which was calculated to be 5.41×10(-6) s(-1) for adenine and 6.27×10(-6) s(-1) for guanine. CE identified depurination on treated samples when it occurred with a loss of >4% of the basic moieties. The molecular features of the A-P enriched samples were investigated by using molecular assays (agarose gel electrophoresis, UV spectrophotometry and quantitative PCR) and the consistency of the results of the STR typing were compared with the degree of depurination of the PCR template. The treated DNA samples showed molecular features such as fragmentation, altered OD(260) /OD(280) ratios and decreased ability of the quantitative PCR to synthesise the human target, related to the severity of depurination. A satisfactory correlation between the degree of damage and the amount of residual PCR-sensitive target sequences was also demonstrated (r(2) =0.9717). The conventional and mini-STR typing of the samples showed that the genetic outcome was influenced by a depurination damage that exceeded 4% when locus drop-outs and artefactual PCR results were evident. As the success of STR typing depends on the integrity of the DNA recovered from the samples, the CE-UV, physical and molecular assays described here are proposed as a set of useful methods in the analysis of certain forensic and clinical samples, for a critical evaluation of the outcome of the genetic testing.  相似文献   

17.
Developing diagnostic tools based on the application of known disease/phenotype‐associated copy number variations (CNVs) requires the capacity to measure CNVs in a multiplex format with sufficient reliability and methodological simplicity. In this study, we developed a reliable and user‐friendly multiplex CNV detection method, termed stuffer‐free MLPA‐CE‐SSCP, that combines a variation of multiplex ligation‐dependent probe amplification (MLPA) with CE‐SSCP. In this variation, MLPA probes were designed without the conventionally required stuffer sequences. To separate the similar‐sized stuffer‐free MLPA products, we adopted CE‐SSCP rather than length‐dependent conventional CE analysis. An examination of the genomic DNA from five cell lines known to vary in X‐chromosome copy number (1–5) revealed that copy number determinations using stuffer‐free MLPA‐CE‐SSCP were more accurate than those of conventional MLPA, and the CV of the measured copy numbers was significantly lower. Applying our system to measure the CNVs on autosomes between two HapMap individuals, we found that all peaks for CNV targets showed the expected copy number changes. Taken together, our results indicate that this new strategy can overcome the limitations of conventional MLPA, which are mainly related to long probe length and difficulties of probe preparation.  相似文献   

18.
An in‐capillary 2, 2‐diphenyl‐1‐picrylhydrazyl (DPPH)‐CE‐the DAD (in‐capillary DPPH‐CE‐DAD) combined with reversed‐electrode polarity stacking mode has been developed to screen and quantify the active antioxidant components of Cuscuta chinensis Lam. The operation parameters were optimized with regard to the pH and concentration of buffer solution, SDS, β‐CDs, organic modifier, as well as separation voltage and temperature. Six antioxidants including chlorogenic acid, p‐coumaric acid, rutin, hyperin, isoquercitrin, and astragalin were screened and the total antioxidant activity of the complex matrix was successfully evaluated based on the decreased peak area of DPPH by the established DPPH‐CE‐DAD method. Sensitivity was enhanced under reversed‐electrode polarity stacking mode and 10‐ to 31‐fold of magnitude improvement in detection sensitivity for each analyte was attained. The results demonstrated that the newly established in‐capillary DPPH‐CE‐DAD method combined with reversed‐electrode polarity stacking mode could integrate sample concentration, the oxidizing reaction, separation, and detection into one capillary to fully automate the system. It was considered a suitable technique for the separation, screening, and determination of trace antioxidants in natural products.  相似文献   

19.
We report the evaluation of short tandem repeat (STR) locus D2S1242 (GDB ID G00-309-429) for forensic purposes, investigated by polymerase chain reaction (PCR) amplification and both native and denaturating polyacrylamide gel electrophoresis in 147 unrelated Austrians. No deviations from Hardy-Weinberg expectations were observed. The mean exclusion chance (MEC) was 0.669, the discriminating power (DP) was 0.947, and the observed heterozygosity rate was 0.856. An allelic ladder consisting of eight sequenced alleles (141-167 and 175 bp) was constructed. Sequence analysis revealed that the locus comprised two repeat motifs varying in number between alleles GAAA and GAAG. According to the number of tetranucleotide repeats the smallest allele was designated as 10 and the largest allele as 18.  相似文献   

20.
Self‐adjuvanting tricomponent vaccines were prepared and assessed for their self‐assembly and immunological activity in mouse models. The vaccines each consisted of a peptide or glycopeptide antigen that corresponds to a complete copy of the variable‐number tandem repeat (VNTR) of the tumor‐associated mucin 1 (MUC1) glycoprotein, the universal T‐cell helper peptide epitope PADRE, and the immunoadjuvant Pam3CysSer. The vaccines were shown to spontaneously self‐assemble in water to form isotropic particles varying in size from 17 to 25 nm and elicited robust humoral responses in murine models without the addition of an external adjuvant. The serum antibodies could recognize tumor‐associated MUC1 epitopes on the surface of MCF7 breast‐cancer cells and B16 melanoma cells, which overexpress this tumor‐associated glycoprotein.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号