首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A super-resolution imaging method using dynamic grating based on liquid-crystal spatial light modulator (SLM) is developed to improve the resolution of a digital holographic system. The one-dimensional amplitude cosine grating is loaded on the SLM, which is placed between the object and hologram plane in order to collect more high-frequency components towards CCD plane. The point spread function of the system is given to confirm the separation condition of reconstructed images for multiple diffraction orders. The simulation and experiments are carried out for a standard resolution test target as a sample, which confirms that the imaging resolution is improved from 55.7 μm to 31.3 μm compared with traditional lensless Fourier transform digital holography. The unique advantage of the proposed method is that the period of the grating can be programmably adjusted according to the separation condition.  相似文献   

2.
Fiolka R  Beck M  Stemmer A 《Optics letters》2008,33(14):1629-1631
In wide-field fluorescence microscopy, illuminating the specimen with evanescent standing waves increases lateral resolution more than twofold. We report a versatile setup for standing-wave illumination in total internal reflection fluorescence microscopy. An adjustable diffraction grating written on a phase-only spatial light modulator controls the illumination field. Selecting appropriate diffraction orders and displaying a sheared (tilted) diffraction grating allows one to tune the penetration depth in very fine steps. The setup achieves 91 nm lateral resolution for green emission.  相似文献   

3.
The ability to quantitatively retrieve transverse phase maps during imaging by using coherent x rays often requires a precise grating or analyzer-crystal-based setup. Imaging of live animals presents further challenges when these methods require multiple exposures for image reconstruction. We present a simple method of single-exposure, single-grating quantitative phase contrast for a regime in which the grating period is much greater than the effective pixel size. A grating is used to create a high-visibility reference pattern incident on the sample, which is distorted according to the complex refractive index and thickness of the sample. The resolution, along a line parallel to the grating, is not restricted by the grating spacing, and the detector resolution becomes the primary determinant of the spatial resolution. We present a method of analysis that maps the displacement of interrogation windows in order to retrieve a quantitative phase map. Application of this analysis to the imaging of known phantoms shows excellent correspondence.  相似文献   

4.
利用厚体布拉格光栅的波长选择特性对目标光场进行窄带滤波,是实现高光谱成像的一种新途径。基于严格耦合波理论,设计了体布拉格光栅结构,探索了厚体布拉格光栅的制作工艺,搭建系统光路验证了体布拉格光栅的光谱成像能力。研究结果表明:要获得较窄滤波谱宽,需要提高体布拉格光栅的厚度周期比,并严格控制入射光束发散角;刻写光束质量、震动和偏振会极大地影响制作的光栅条纹面质量,需要从优化写入光的光束均匀性、采用防震措施以及调整两刻写光束偏振一致性等方面优化刻写过程,以提高光栅的衍射效率和质量;验证了体布拉格光栅滤波片进行空间二维面阵成像的能力,宽谱光源透射条件下,通过对入射光束进行准直,滤波谱宽5 nm左右,空间分辨率约4 lines/mm;漫反射条件下,使用体布拉格光栅对进行色散补偿,能够实现较为清晰的成像,空间分辨率约4.9 lines/mm。  相似文献   

5.
Shi P  Huang K  Li YP 《Optics letters》2012,37(3):359-361
The resolution of imaging is limited by the missing of high-frequencies information. The superlens employing negative refraction can compensate for these components. But for the directional coupling of Bloch waves and the low coupling efficiency of large-angle waves, the resolution of subwavelength imaging is not satisfactory. However, the subwavelength metallic grating can produce high-order diffracted waves carrying a lot of high-frequencies information. Therefore, this structure is used to inhibit the zero-order diffraction and enhance the high-order diffraction to achieve super-resolution.  相似文献   

6.
为实现成像光谱仪系统的直视性和小型化特点,设计一种棱镜-光栅-棱镜(PGP)结合式元件,作为分光系统的成像光谱仪光学系统装置。系统主要包括PGP分光原件、准直系统、成像系统和接收系统。光栅采用体全息相位光栅,可以获得很高的衍射效率,准直和成像镜采用对称式结构,可以有效地消垂轴像差。根据实际指标探测器像元尺寸为20 m20 m,像元数为512512,采用双像元合并方法,光谱通道数为148个,狭缝大小为10.2 mm10.2 mm,波段在400 nm~800 nm,物方数值孔径为0.15。分析了PGP光谱成像系统的原理、特点,对参数关系和体全息相位型光栅的衍射效率进行了详细的讨论。分析结果表明:PGP元件在整个光谱范围内理论衍射效率大于0.6,采用ZEMAX软件进行优化设计,得到系统的平均光谱分辨率优于3 nm,在截止频率处平均传递数大于0.7,系统总长90 mm。  相似文献   

7.
陶珺  穆磊  杜平 《光子学报》2010,39(1):42-46
为了实现大坝渗流监测,提出了一种采用光谱成像技术的光纤Bragg光栅传感器和多点传感系统。基于室内实验结果,对监测系统可靠性与监测数据准确度进行和多点传感信号分辨因子分析,结果表明:用于坝体温度场检测的光线光栅传感器波长温度响应灵敏度可达0.009 1nm/℃;由光源带宽决定的测试系统可实现多个传感器的复用。实践表明:采用光纤光栅传感系统可进行大坝渗流自动监测,特别是在系统防雷击、抗干扰性方面,与传统仪器相比具有明显优势。  相似文献   

8.
余飞鸿  梁荫中 《光子学报》1993,22(4):311-320
本文首次用矩阵光学理论结合光栅衍射相干条件,推出双光栅成象的几何光学表示式,用象位移叠加的观点解释了双光栅成象系统Talbot自成象以及双光栅成象现象,首次将双光栅成象现象分为1)基于光栅和透镜组成系统对第一块光栅进行成象的双光栅成象和2)基于编码光源成象原理的双光栅成象,指出这是两种截然不同的双光栅成象,扩展了双光栅成象的物理意义。最后给出了实验结果。  相似文献   

9.
Kim K  Oh Y  Lee W  Kim D 《Optics letters》2010,35(20):3501-3503
In this Letter, we explore plasmonics-based spatially activated light microscopy (PSALM) for sub-diffraction-limited imaging of biomolecules. PSALM is based on the spatially switched activation of local amplified electromagnetic hot spots under multiple light incidence conditions. The hot spots are associated with surface plasmons that are excited and localized by surface nanostructures. The feasibility of the concept was demonstrated by imaging fluorescent nanobeads on a two-dimensional gold nanograting of a 100-nm-wide grating ridge, the size of which is the measure of the imaging resolution. The result confirms the performance of PSALM for imaging nanobeads at a resolution below the conventional diffraction limit.  相似文献   

10.
双光栅切换微型平场全息凹面光栅光谱仪   总被引:1,自引:0,他引:1  
基于CCD的微型平场全息凹面光栅光谱仪,以其简单紧凑的结构和快速高效的工作方式在光谱分析领域获得了广泛的应用。但是,由于受限于色散距离,单纯依靠优化光栅像差很难进一步使光谱分辨率获得大幅提高。提出一种双光栅切换微型平场全息凹面光栅光谱仪的设计方法,用两个使用结构相同的光栅代替传统的单光栅设计,给出一个光谱范围为400~1000nm光谱仪的具体设计,计算显示光谱分辨率最大可提高为原来的2.5倍。通过对光栅衍射效率的计算分析,说明此方法能够显著改善仪器的通光效率。设计制作了原理样机,进行了装调测试,实验结果与理论计算相吻合。  相似文献   

11.
提出了一种新的时域两维荧光寿命显微测量技术,建立了一套荧光寿命成像显微系统,介绍了这种测量技术的数据处理方法。用标准样品对该系统进行了测试,实验表明,该系统的时间分辨率为2ps,在放大倍率为100倍的情况下,该系统的空间分辨率为8um。如果在现有的设备下采用更细的网格板和微位移系统,那么该系统的空间分辨率可小于1um.  相似文献   

12.
介绍了基于几何莫尔条纹原理和衍射干涉原理的两种光栅精密位移测量系统及各自的特点。综述了国内外对光栅干涉式精密位移测量系统的研究进展,总结了系统存在的关键问题及发展趋势。光栅干涉式精密位移测量系统的优点是对环境要求小,测量分辨率和精度较高,结构紧凑,成本低。该系统需要解决的问题包括提高光栅以及光学元器件制造和安装精度;寻求一种更高精度的检测手段对光栅位移测量系统进行标定等。光栅干涉式精密位移测量系统的发展方向为更高测量分辨率和精度,大量程、多维度测量以及尺寸小巧。该系统在现代工业加工精密制造领域将具有更广阔的应用前景。  相似文献   

13.
曝光系统离焦对平面全息光栅衍射波前的影响   总被引:1,自引:0,他引:1  
波前像差是衍射光栅的重要技术指标,它直接影响光栅的分辨率。由光致刻蚀剂记录两束相干光干涉条纹是制作全息光栅的关键步骤。为了提高全息光栅曝光系统调整精度、减小离焦、降低光栅的衍射波前像差,从离焦对反射球面准直镜的准直光平行度的影响程度出发,分析了准直光平行度对全息光栅衍射波前像差的影响。理论分析和数值模拟结果表明,准直镜调整误差直接决定全息光栅衍射波前像差大小。以3种不同刻线密度光栅为例,得出了准直镜调整误差的允许变化范围。  相似文献   

14.
吴彤  孙帅帅  王绪晖  王吉明  赫崇君  顾晓蓉  刘友文 《物理学报》2018,67(10):104208-104208
相比传统光谱仪,基于线性波数光谱仪的谱域光学相干层析(OCT)无需对非线性波数干涉光谱数据进行重采样和插值,可大大减少数据计算量并提高成像灵敏度.通过模拟计算干涉光谱信号和点扩散函数,以点扩散函数半峰全宽值的倒数作为评价准则,可以优化包括色散棱镜材料的折射率、顶角角度以及衍射光栅和色散棱镜之间旋转角角度的线性波数光谱仪的结构参数.根据优化结果,实验中选用F2玻璃等边色散棱镜,以光栅-棱镜间旋转角角度为21.8°搭建了最优化线性波数光谱仪,并引入谱域OCT成像系统.实验测得成像系统的轴向分辨率达到8.52μm,灵敏度达到91 dB,6 dB成像深度达到1.2 mm.结合具有通用并行计算能力的图形处理卡,在无需重采样和插值的情况下可实时处理和显示人手指指甲皮肤接缝处的横断面OCT图像,验证了基于最优化线性波数光谱仪的谱域OCT系统的成像性能.  相似文献   

15.
提出了一种利用CCD和光栅实时测量入射激光波长及方位的新方法。该方法利用成像CCD,通过测量入射激光成像点在电视成像坐标系中的位置来确定激光的入射方位;根据光学系统中成像点位置与光栅入射角和衍射角的几何关系,利用光栅测量入射激光的波长。介绍了该方法的测量原理及光学系统结构,给出了测量入射激光波长及方位的计算表达式,分析了测量误差,并在室内通过测量实验对该方法进行了验证。  相似文献   

16.
杨国光  徐明 《光学学报》1993,13(9):05-811
本文对一种成像系统——光栅干涉合成孔径成像系统进行了研究,证明这种频域成像系统具有高分辨,甚至超分辨的性能.用计算机控制的模拟点目标以及同步光栅扫描,完成了二维孔径合成实验,证明这种大瞬时光谱带宽的频谱孔径不受衍射极限限制,对空间点目标有极高的位置分辨率,存在超分辨的可能性.  相似文献   

17.
对基模高斯光束经方形光阑限制光学系统的光斑传输变换规律进行了论述.对于任一共轴光学系统,在不考虑有效光阑前面元件的衍射和变换时,考察入射光经有效光阑和其后面的元件发生衍射,根据柯林斯公式,对于非成像光学系统,采用稳相法得到出射光场的振幅分布;对于成像光学系统,根据像传递原理得到出射光场的振幅分布,最后得出出射光斑大小由有效光阑边长与光阑处高斯光束腰斑大小比较决定的结论.  相似文献   

18.
刘壮  巩岩 《光子学报》2012,41(7):776-780
针对太阳极紫外成像光谱仪的应用目的与工作环境,设计了一种太阳极紫外成像光谱仪的光学系统.该系统由望远系统、狭缝、光栅与探测器组成.望远系统采用离轴WolterⅡ型结构,入射光掠入射进入系统,具有光谱范围宽、稳定性高、克服恶劣空间环境能力强等优点.扫描镜采用平面反射镜,成像质量不随扫描角的改变而改变.分光光栅采用超环面3 600lines/mm变间距光栅,与超环面等间距光栅相比,具有成像质量高、光谱分辨率高、缩短系统长度的优势.工作波段为17.0~21.0nm,可满足探索温度在5.8≤log T≤6.3区间的宁静日冕的需要.视场为1 228″×2 400″,空间分辨率达到0.8arc second/pixel,光谱分辨率约为0.001 98nm/pixel,总长度不超过2.5m.计算了望远系统的理论有效面积,给出了望远系统的成像质量与实际的视场.系统整体的成像质量、光栅的谱线弯曲与谱带弯曲,均满足实际应用要求.  相似文献   

19.
侯国辉  罗腾  陈秉灵  刘杰  林子扬  陈丹妮  屈军乐 《物理学报》2017,66(10):104204-104204
双光子荧光与相干反斯托克斯拉曼散射同属于三阶非线性效应,二者之间的差异与联系是一个值得研究的问题.本文基于自行搭建的超连续谱近红外宽带相干反斯托克斯拉曼散射显微成像系统进行光谱成像,同时通过理论与实验对比分析了双光子荧光与相干反斯托克斯拉曼散射图像存在差异的原因.结果表明,具有亚微米以上横向分辨率的相干反斯托克斯拉曼散射成像系统,可以使用较大尺寸的荧光珠进行双光子荧光成像,通过解卷积得到双光子荧光成像的系统分辨率,并将它近似等效于相干反斯托克斯拉曼散射成像系统的当下分辨率.如果需要得到相干反斯托克斯拉曼散射成像系准确的分辨率结果,就必须使用尺寸比相干反斯托克斯拉曼散射成像系统实际分辨率小的球形样品进行实验测量.  相似文献   

20.
频谱编码显微镜是用衍射光栅和光谱分析装置来获得显微图像.样品上不同的位置被不同的波长照明,通过对反射光光谱进行解码来得到空间信息.搭建了一个基于超连续光源和自制光谱仪的频谱编码显微成像系统,其横向分辨率为1.72±0.13μm(编码线方向)和1.26±0.08μm(垂直于编码线方向),测得不同横向位置处的轴向分辨率有差异.对离体猪肝组织不同部位进行了成像(可见血管、肝窦内皮细胞和肝细胞);对鸡心组织以10μm深度间隔进行成像,测得不同深度处结构信息不一样.结果表明,采用该频谱编码成像的方法能够进行高分辨的深度成像.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号