共查询到20条相似文献,搜索用时 15 毫秒
1.
Optical imaging is an emerging method for bio-imaging. The advantages of this imaging provide non-ionizing and safe radiation, non-invasive and functional medical imaging. Due to diffusion of photons inside biological tissues, its image processing is complicated. So in spite of these advantages, this imaging method has not been progressed like ultrasound imaging and magnetic resonance imaging (MRI). Also, the penetration depth of photons inside biological phantom is low. To overcome this problem, the complicated diffusion of photons through tissue must be modeled. The diffuse equation can be applied to simulate photons through turbid media like biological tissues. In this paper, the diffuse equation is used to study propagation of diffuse photons. The green function method is applied to solve this equation, and then the optical properties of abnormalities in breast phantom are estimated. This fast method can be applied for image processing. 相似文献
2.
建立光学投影层析三维成像系统,该系统包括光学成像、图像采集、断层重建及三维显示,重建算法为滤波反投影算法.实验结果表明:利用该系统得到的重建图像与样品的形状吻合,重建结果边缘清晰,伪迹较小. 相似文献
3.
O. Lehtikangas V. Kolehmainen S.R. Arridge 《Journal of Quantitative Spectroscopy & Radiative Transfer》2010,111(10):1406-1417
In diffuse optical tomography, light transport theory is used to describe photon propagation inside turbid medium. A commonly used simplification for the radiative transport equation is the diffusion approximation due to computational feasibility. However, it is known that the diffusion approximation is not valid close to the sources and boundary and in low-scattering regions. Fokker-Planck equation describes light propagation when scattering is forward-peaked. In this article a numerical solution of the Fokker-Planck equation using finite element method is developed. Approach is validated against Monte Carlo simulation and compared with the diffusion approximation. The results show that the Fokker-Planck equation gives equal or better results than the diffusion approximation on the boundary of a homogeneous medium and in turbid medium containing a low-scattering region when scattering is forward-peaked. 相似文献
4.
5.
Tanja Tarvainen Ville Kolehmainen Jari P. Kaipio 《Journal of Quantitative Spectroscopy & Radiative Transfer》2011,112(16):2600-2608
The coupled radiative transport-diffusion model can be used as light transport model in situations in which the diffusion equation is not a valid approximation everywhere in the domain. In the coupled model, light propagation is modelled with the radiative transport equation in sub-domains in which the approximations of the diffusion equation are not valid, such as within low-scattering regions, and the diffusion approximation is used elsewhere in the domain. In this paper, an image reconstruction method for diffuse optical tomography based on using the coupled radiative transport-diffusion model is developed. In the approach, absorption and scattering distributions are estimated by minimising a regularised least-squares error between the measured data and solution of the coupled model. The approach is tested with simulations. Reconstructions from different cases including domains with low-scattering regions are shown. The results show that the coupled radiative transport-diffusion model can be utilised in image reconstruction problem of diffuse optical tomography and that it produces as good quality reconstructions as the full radiative transport equation also in the presence of low-scattering regions. 相似文献
6.
In the present cosmetic market, the skin image obtained from a hand-held camera is two-dimensional (2-D). Due to insufficient
penetration, only the skin surface can be detected, and thus phenomena in the dermis cannot be observed. To take the place
of the conventional 2D camera, a new hand-held imaging system is proposed for three-dimensional (3-D) skin imaging. Featuring
non-invasiveness, optical coherence tomography (OCT) has become one of the popular medical imaging techniques. The dermal
images shown in OCT-related reports were mainly single-colored because of the use of a monotonic light source. With three
original-colored beams applied in OCT, a full-colored image can be derived for dermatology. The penetration depth of the system
ranges from 0.43 to 0.78 mm, sufficient for imaging of main tissues in the dermis. Colorful and non-invasive perspectives
of deep dermal structure help to advance skin science, dermatology and cosmetology. 相似文献
7.
频域光学相干层析系统中扫描机构定位精度、 机械抖动及样品移动会造成A扫描信号幅值和相位发生波动, 影响生物组织成像质量. 利用最小灰度差匹配、Lorentzian曲线极值拟合和谱域光程差补偿等方法对A 扫描信号进行幅值配准. 通过对A扫描信号相位分布特征的匹配实现相位差检测与配准. 通过求已配准的A 扫描复信号之差, 消除静态组织对血流成像的影响. 进行了人眼扫描实验, 有效提取了视网膜三维血流图像. 实验结果表明, 提出的幅值及相位配准方法大大减小了系统扫描精度、人眼跳动等因素对生物组织在体成像质量的影响. 快速、精确的相位配准方法也可广泛应用在多普勒OCT、相位显微等与相位分辨有关的光学成像领域.
关键词:
频域光学相干层析
配准
血流成像
相位分布特征 相似文献
8.
We present the optical coherence tomography (OCT) made to investigate the early dental caries in human teeth and compare its
results with those taken by conventional imaging modalities including light illuminating examination (LIE), digital intra-oral
radiography (DIOR), and electron probe micro analyzer (EPMA). Morphological features and caries-involved areas of the dental
structure were mainly investigated by LIE, DIOR, and OCT to study the infection of the caries lesion in pits and fissures.
The biochemical information acquired with EPMA and the morphological features taken with OCT in the early stage of caries
were compared and analyzed to present an objective and practical index for the degree of caries. The experimental results
allow us to conclude that OCT could be used to provide quantitative analysis of caries based on the reflectivity difference
in the specimen. 相似文献
9.
10.
砂泥岩薄互层电阻率准确测量是提高泥质砂岩储层计算的一项重要工作。为了解决薄互层电阻率准确测量问题,该文提出一种三维感应成像测井仪的设计与实现方法。首先,基于感应电磁测量方法,设计由1个三轴发射器、4个单轴接收阵列和3个三轴的接收阵列组成的三维探测器。在此基础上,通过三维线圈系参数与结构创新设计、多频循环发射、高精度多道同步采集、高性能发射接收一体化集成等技术实现,在每一个深度点可获取78个电导率测量值。最后,利用数据校正与处理技术来消除各种环境影响,经过理论模型和实际资料的处理结果均证实,该仪器处理得到5条不同径向探测深度的水平电阻率与垂向电阻率、地层倾角等曲线,实现了对薄互层电阻率的准确测量。 相似文献
11.
We demonstrate the feasibility of a compact single-shot full-field time domain optical coherence tomography (OCT) for imaging dynamic biological sample in real-time. The system is based on a Linnik type polarization Michelson interferometer and a four-quadrature phase-stepper optics, which can simultaneously capture four quadraturely phase-stepped interferograms on a single CCD. Using a superluminescent diode as light source with center wavelength of 842 nm and spectral width of 16.2 nm, the system yields an axial resolution of 19.8 μm, and covers a field of view of 280 × 320 μm2 (220 × 250 pixels) with a transverse resolution of 4.4 μm by using a 10× microscope objective (0.3 NA). Three-dimensional OCT images of biological samples such as an onion slice and a diaptomus were obtained without any image averaging or pixel binning. In addition, in vivo depth resolved dynamic imaging was demonstrated to show the beating internal structure of a diaptomus with a fame rate of 5 fps. 相似文献
12.
The maximum data rate that can be achieved in diffuse indoor optical wireless communication (OWC) is limited due to the effect of intersymbol interference (ISI). The adverse effect of ISI on the system performance can be minimised using a channel equaliser at the receiver. In this study, digital signal detection is formulated as a classification problem and hence a classifier is adopted at the receiver. The bit error performance of classifiers with non-linear decision boundary including a multilayer perceptron (MLP), a support vector machine (SVM), the radial basis function (RBF), and the Bayesian classifier is studied along with traditional equaliser and reported here. The MLP offers the best performance; however there is trade-off between the performance and complexity especially at highly diffuse channel. 相似文献
13.
光学综合孔径成像技术实验研究 总被引:2,自引:0,他引:2
根据光学综合孔径成像系统的成像质量与点扩散函数和光学传递函数的关系,以G o lay-3阵列结构为例,从空间域和频率域对光学综合孔径成像技术进行理论仿真和实验研究。在空间域从理论上分析光学综合孔径成像系统的点扩散函数,对复杂目标的成像通过目标函数与点扩散函数的卷积求得,点扩散函数决定了成像质量。通过数值仿真和模拟实验取得了点扩散函数强度分布图,两者分布规律一致证明理论分析正确。在频率域研究光学综合孔径调制传递函数,理论仿真和实验取得的调制传递函数表明,空间域和频率域内光学综合孔径成像技术的理论分析与实验结果具有较好的一致性。 相似文献
14.
论述了干涉成像光谱技术的工作原理,采用光线追迹的方法对基于Sagnac棱镜和Savart偏光镜的干涉仪中的光线传播规律进行了分析,推导出了无狭缝式干涉成像光谱仪光通量的精确理论计算公式,并对干涉成像光谱仪中具有代表性的Savart型偏振干涉成像光谱仪光通量和改型Sagnac成像光谱仪光通量进行了分析比较.通过计算机模拟给出了系统光通量随入射角和波长变化的关系曲线.该研究对干涉成像光谱仪的研究和工程化研制具有重要的指导意义.
关键词:
干涉成像光谱仪
光通量
透射比 相似文献
15.
AOTF成像光谱仪光学系统的最优方案选择 总被引:1,自引:1,他引:1
基于声光可调谐滤波器(AOTF)的成像光谱仪是一种新型的成像光谱仪,它除了具有一般成像光谱仪的二维空间信息与一维光谱信息外,还能获得目标的偏振信息。在实际应用中AOTF可接收的光束孔径角一般不大于5~6,因而受到所采用声光晶体可接收角度的限制,AOTF光谱成像仪的光学系统不能同时兼顾大孔径与大视场。要求AOTF成像光谱仪视场满足128128像元,TeO2晶体尺寸为10 mm10 mm,根据声光可调谐滤波器成像光谱仪光学系统的特点,分析比较了2种光学系统总体方案,最终将系统的孔径光栏放置在晶体上,TeO2晶体尺寸限制了孔径光栏的尺寸,晶体可接收的角度决定了系统的视场角,提高了能量利用率,获得较高的图像信噪比。 相似文献
16.
将成像光学系统同时用作激光发射天线的共口径设计可有效减轻卫星载荷质量和应对各种突发状况。首先根据激光通信的能量计算链路,分析了激光发射天线的设计要求,明确了激光发射天线与成像光学系统的不同;然后根据特定的成像光学系统给出了3种具有普适性的共口径设计方法,并对这3种方法的性能进行了分析和比较,给出了它们的优缺点和适用范围;最后对所设计的共口径系统进行了发射光束仿真,经过对设计系统加工、装调后进行了室内的成像、通信实验,结果显示发射激光的最小束散角可达18.2 μrad,接近系统衍射极限,出射光斑质量良好,接收到的图像与成像系统所成图像肉眼观测无失配。初步证实该共口径设计可实现光学系统的成像和通信任务要求。 相似文献
17.
18.
Some advantages of using 3D techniques in small scale NMR imaging are suggested. In particular the 3D methods are likely to be useful in slow dynamical processes occurring in vivo. Three-dimensional images obtained with our first home built prototype are also reported. 相似文献
19.
提出了一种真实场景三维视频采集及彩色显示的方法.设计了一种采用条纹投影的实时三维成像系统及采用液晶空间光调制器的实时全息彩色三维显示系统.在三维成像系统中采用π相移正弦条纹与编码图案结合实现绝对相位测量,从而可以测量孤立物体.同时对采用数字微镜的投影仪进行改造,实现高速投影,并与高速摄像机配合实现三维视频采集.首先利用实时三维成像系统同时获取三维场景的彩色强度像和距离像;然后根据这些三维成像数据, 设计和制作计算菲涅耳全息图;最后在实时全息彩色三维显示系统中再现.三维信息的采集和显示速度达到了60帧每秒. 相似文献
20.
改进和完善宽场光学相干断层成像技术(WFOCT)的主要方法是从光源、系统光路等方面进行改进.研究WFOCT系统的成像状态和环境状态对系统的横向分辨率的影响,借助ZEMAX光学设计软件模拟该系统的干涉效果,在实验中采用八步移相法来解析样品的二维图像信息,将解析出来的样品图像赋值到图像变量中进行存储显示.实验与模拟结果表明:模拟仿真获得的干涉信号含有对比度和平行度很高的干涉条纹,证明了利用ZEMAX软件模拟仿真干涉系统的可行性. 相似文献