首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Surfactants added to the mobile phases in reversed-phase liquid chromatography (RPLC) give rise to a modified stationary phase, due to the adsorption of surfactant monomers. Depending on the surfactant nature (ionic or non-ionic), the coated stationary phase can exhibit a positive net charge, or just change its polarity remaining neutral. Also, micelles in the mobile phase introduce new sites for solute interaction. This affects the chromatographic behavior, especially in the case of basic compounds. Two surfactants of different nature, the non-ionic Brij-35 and the anionic sodium dodecyl sulfate (SDS) added to water or aqueous-organic mixtures, are here compared in the separation of basic compounds (β-blockers and tricyclic antidepressants). The reversible/irreversible adsorption of the monomers of both surfactants on the stationary phase was examined. The changes in the nature of the chromatographic system using different columns and chromatographic conditions were followed based on the changes in retention and peak shape. The study revealed that Brij-35 is suitable for analyzing basic compounds of intermediate polarity, using "green chemistry", since the addition of an organic solvent is not needed and Brij-35 is a biodegradable surfactant. In contrast, RPLC with hydro-organic mixtures or mobile phases containing SDS required high concentrations of organic solvents.  相似文献   

2.
The influence of temperature on the retention behavior of epirubicin and its analogues on high purity silica with reversed-phase solvents has been systematically investigated. It was found that temperature effects on retention are highly dependent on the type and concentration of organic modifier, as well as the pH of the mobile phase. In organic-rich mobile phases, the type of organic modifier plays an important role. With an aprotic solvent as modifier, retention times show anomalous increases with elevated temperature. At the same time, both efficiency and resolution are significantly improved but this is not the situation with a protic solvent as modifier. In addition, temperature shows different effects on retention time and selectivity when the pH is changed, and temperature-dependent selectivity reversal is found at higher pHs. In aqueous-rich mobile phases, regardless of the nature of the organic solvent and pH, retention of solutes drops as temperature is raised. It seems that the effect of temperature on chromatographic behavior of the solutes on bare silica using mobile phases containing various organic modifiers or pHs, results from a number of different retention mechanisms.  相似文献   

3.
The measurement of pH in chromatographic mobile phases has been a constant subject of discussion during many years. The pH of the mobile phase is an important parameter that determines the chromatographic retention of many analytes with acid-base properties. In many instances a proper pH measurement is needed to assure the accuracy of retention-pH relationships or the reproducibility of chromatographic procedures. Three different methods are common in pH measurement of mobile phases: measurement of pH in the aqueous buffer before addition of the organic modifier, measurement of pH in the mobile phase prepared by mixing aqueous buffer and organic modifier after pH calibration with standard solutions prepared in the same mobile phase solvent, and measurement of pH in the mobile phase prepared by mixing aqueous buffer and organic modifier after pH calibration with aqueous standard solutions. This review discusses the different pH measurement and calibration procedures in terms of the theoretical and operational definitions of the different pH scales that can be applied to water-organic solvent mixtures. The advantages and disadvantages of each procedure are also presented through chromatographic examples. Finally, practical recommendations to select the most appropriate pH measurement procedure for particular chromatographic problems are given.  相似文献   

4.
Two approaches are proposed to measure the effect of different experimental factors (such as the modifier concentration and temperature) on the elution strength and peak shape in reversed-phase liquid chromatography, which quantify the percentage change in the retention factor and peak width (referred to the weakest conditions) per unit change in the experimental factor. The approaches were applied to the separation of a set of flavonoids with aqueous micellar mobile phases of the surfactant Brij-35 (polyoxyethylene(23)dodecanol), in comparison with acetonitrile–water mixtures, using an Eclipse XDB-C18 column. The particular interaction of each flavonoid with the oxyethylene chains of Brij-35 molecules (adsorbed on the stationary phase or forming micelles) changed the elution window, distribution of chromatographic peaks and partitioning kinetics, depending on the hydroxyl substitution in the aromatic rings of flavonoids. At 25?°C, peak shape with Brij-35 mobile phases was significantly poorer with regard to acetonitrile–water mixtures. At increasing temperature, the efficiency of Brij-35 increased, approaching at 80?°C the values obtained at equilibrium conditions, already reached with acetonitrile at 25?°C.  相似文献   

5.
The behaviour of β-blockers in a reversed-phase liquid chromatographic (RPLC) column with mobile phases containing a short-chain alcohol (methanol, ethanol or 1-propanol), with and without the surfactant sodium dodecyl sulphate (SDS), was explored. Two surfactant-mediated RPLC modes were studied, where the mobile phases contained either micelles or only surfactant monomers at high concentration. Acetonitrile was also considered for comparison purposes. A correlation was found between the effects of the organic solvent on micelle formation (monitored by the drop weight procedure) and on the nature of the chromatographic system (as revealed by the retention, elution strength and peak shape of β-blockers). When SDS is added to the mobile phase, the free surfactant monomers bind the C18 bonded chains on the stationary phase, forming an anionic layer, which attracts strongly the cationic β-blockers. The retention is modified as a consequence of the solving power of the organic solvent, micelles and surfactant monomers. The molecules of organic solvent bind the micelles, modify their shape, and may avoid their formation. They also bind the monomers of surfactant, desorbing them from the stationary phase, which affects the retention. The remaining surfactant covers the free silanols on the siliceous support, avoiding the interaction with the cationic solutes. The retention of β-blockers results from a combination of electrostatic and hydrophobic interactions, the latter being weaker compared to the hydro-organic system. The peak efficiencies and asymmetries are excellent tools to probe the surfactant layer on the stationary phase in an SDS/organic solvent system. The peaks will be nearly symmetrical wherever enough surfactant coats the stationary phase (up to 60% methanol, 40% ethanol, 35% 1-propanol, and 50% acetonitrile).  相似文献   

6.
Small organic acids have shown significant retention on various stationary phases, such as amide, amino, aspartamide, silica and sulfobetaine phase commonly used in hydrophilic interaction chromatography (HILIC). This study investigated the effect of chromatographic conditions on the retention behavior of organic acids in HILIC using the tool of design of experiment (DOE). The results of the DOE study indicated that both the content of organic solvent (i.e., acetonitrile) and salt concentration in the mobile phase had significant effects on the retention of organic acids. Higher content of organic solvent in the mobile phase led to a significant increase in retention on all types of stationary phases. Increasing salt concentration also resulted in a moderate increase in retention; however, the effect of salt concentration varied with the type of stationary phase. The study also revealed that column temperature had less impact on retention than organic solvent content and salt concentration in HILIC.  相似文献   

7.
In an effort to expand the range of applications of enhanced-fluidity liquid chromatography (EFLC) to strongly polar and basic analytes, fluoroform (CHF3) was investigated as a fluidity-enhancing agent. Fluoroform was chosen due to its high polarity, low viscosity and chemical inertness toward water and basic analytes. A group of representative basic compounds, tricyclic antidepressants, covering a wide range of polarity was chosen as model compounds. Their retention behavior on a C18 stationary phase in methanol/phosphate buffer and methanol/phosphate buffer/CHF3 mobile phases was characterized. The chromatographic performance with mobile phase conditions of different pH, with and without CHF3 addition and with addition of triethylamine was studied. The advantages of using CHF3 enhanced and buffered mobile phases were shown in the much improved chromatographic performance, such as shortened analysis time, increased efficiency, lower pressure drop and improved selectivity. Furthermore, this study demonstrated for the first time, that a commercial instrument could be readily utilized for EFLC separations which greatly expands the application range of the EFLC technique and chromatographic instrumentation.  相似文献   

8.
This work describes chromatographic properties of reversed-phase/cation-exchange/anion-exchange trimodal stationary phases. These stationary phases were based on high-purity porous spherical silica particles coated with nano-polymer beads using an electrostatically driven self-assembly process. The inner-pore area of the material was modified covalently with an organic layer that provided both reversed-phase and anion-exchange properties while the outer surface was coated with nano-sized polymer beads with strong cation-exchange characteristics. This design ensured spatial separation of the anion-exchange and the cation-exchange regions, and allowed reversed-phase, anion-exchange and cation-exchange retention mechanisms to function simultaneously. Chromatographic evaluation of ions and small molecules suggested that retention of ionic analytes was influenced by the ionic strength, pH, and mobile phase organic solvent content, and governed by both ion-exchange and hydrophobic interactions. Meanwhile, neutral analytes were retained by hydrophobic interaction and was mainly affected by mobile phase organic solvent content. Depending on the specific application, selectivity could be optimized by adjusting the anion-exchange/cation-exchange capacity ratio (selectivity), which was achieved experimentally by using porous silica particles with different surface areas.  相似文献   

9.
用新合成的3-(二乙醇)氨丙基硅氧烷(DEAP)、3-(氮杂18-冠-6)丙基硅氧烷(BCP)作固定相,对二取代苯异构物进行液相色谱分离,研究流动相组成,pH值及其K ̄+离子浓度对色谱行为的影响.探讨溶质保留机理,并比较DEAP、BCP与ODS的色谱性能.  相似文献   

10.
Summary Micellar liquid chromatography methods for quality control of pharmaceutical preparations (capsules, pills, tablets, injections) containing the tricyclic antidepressants amineptine, amitriptiline, clomipramine, doxepin, imipramine, melitracen and nortriptyline alone or together with other CNS drugs like diazepam, medazepam and perphenazine are described. The methods using micellar solutions of cetyltrimethylammonium bromide as mobile phases and UV detection are rapid and reproducible. Due to the versatility of interactions in micellar liquid chromatography, it is possible determine highly hydrophobic compounds such as TCAs in a short time using mobile phases containing low organic solvent concentrations and usual flow rates, in contrast with the RP-HPLC methods proposed for these compounds. Samples preparation only requires solution and adequate dilution with the mobile phase before injection into the chromatographic system.  相似文献   

11.
The present paper examines the effect of the solute ionisation on the retention behaviour in liquid chromatography of a series of peptide and quinolone compounds of biological interest, using acetonitrile-water media as mobile phases and a polymeric-based stationary phase. Polymeric columns with polystyrene-divinylbenzene (PS-DVB) polymer show advantages over silica-based reversed-phase packings since the former are stable in a wide pH range. (s)(s)pKa values have been evaluated using chromatographic data in acetonitrile-water mixtures with acetonitrile percentages of 30, 35, 40 and 50% (v/v) for quinolones and 12.5 and 20% (v/v) for peptides. The quinolones show great retention on PS-DVB phase stationary. It was thus necessary to work with a higher acetonitrile content in the mobile phase than for the less retained peptides. The pH values were measured in the hydroorganic mixtures, used as mobile phases, instead of in water and account was taken of the effect of activity coefficients. The derived equations permit the chromatographic determination of (s)(s)pKa. values of the peptides and quinolones in acetonitrile-water mixtures by fitting it to the experimental data in a nonlinear least-square procedure and also permit the prediction of the effect of (s)(s)pH on their chromatographic behaviour. We have also compared the obtained (s)(s)pKa values with those previously obtained in acetonitrile-water mixtures from potentiometric measurements.  相似文献   

12.
New zwitterionic stationary phases were synthesized by covalently bonding 3-P,P-diphenylphosphonium-propylsulfonate to silica gel. The resulting materials possess both a negatively charged sulfonate group and a positively charged quaternary phosphonium group, which means that there is no net charge over a wide pH range. The retention mechanism and chromatographic behavior of polar solutes under HILIC conditions were studied on these zwitterionic phases. Compared to the commercial ZIC-HILIC column and a bare silica gel stationary phase, the newly synthesized zwitterionic stationary phases provided greater retention, higher peak efficiency and better peak symmetry in the HILIC mode. The analytes examined included: β-blockers, nucleic acid bases and nucleosides, salicylic acid and its analogues, and water soluble vitamins. Factors, such as the type of organic modifiers, solvent composition, pH and the buffer concentration of the mobile phase, have been considered as potential variables for controlling the chromatographic retention of polar analytes.  相似文献   

13.
A new calix[4]crown-5 macrocycle-bonded silica stationary phase (CL-CIMS) was prepared and applied at the same time to develop a chromatographic procedure to separate aromatic amines, phenols and drugs in this study. The chromatographic behaviors of the prepared stationary phase for these analytes were studied and compared with those of ODS (octadecylsilane). The effect of organic modifier content and pH of the mobile phase on retention and selectivity of these compounds were investigated. Some aromatic amines, phenols or drugs on CL-CIMS were successfully separated. The results show that CL-CIMS exhibits high selectivities for the above analytes in high aqueous mobile phases and a bright prospect in routine, fast separation of aromatic amines, phenols and drug compounds. From chromatographic data, it can be concluded that hydrophobic interaction is mainly responsible for the retention behavior as well as hydrogen-bonding interaction, π-π and dipole-dipole interaction.  相似文献   

14.
Adopting a stationary phase convention circumvents problematic definition of the boundary between the stationary and the mobile phase in the liquid chromatography, resulting in thermodynamically consistent and reproducible chromatographic data. Three stationary phase definition conventions provide different retention data, but equal selectivity: (i) the complete solid phase moiety; (ii) the solid porous part carrying the active interaction centers; (iii) the volume of the inner column pores. The selective uptake of water from the bulk aqueous‐organic mobile phase significantly affects the volume and the properties of polar stationary phases. Some polar stationary phases provide dual‐mode retention mechanism in aqueous‐organic mobile phases, reversed‐phase in the water‐rich range, and normal‐phase at high concentrations of the organic solvent in water. The linear solvation energy relationship model characterizes the structural contributions of the non‐selective and selective polar interactions both in the water‐rich and organic solvent‐rich mobile phases. The inner‐pore convention provides a single hold‐up volume value for the retention prediction on the dual‐mode columns over the full mobile phase range. Using the dual‐mode monolithic polymethacrylate zwitterionic micro‐columns alternatively in each mode in the first dimension of two‐dimensional liquid chromatography, in combination with a short reversed‐phase column in the second dimension, provides enhanced sample information.  相似文献   

15.
Berthod A  Schmitt N 《Talanta》1993,40(10):1489-1498
Countercurrent chromatography (CCC) is a separation technique in which the stationary phase is a liquid. The liquid stationary phase retention is a critical problem in CCC. The retention of 18 organic solvents in a hydrodynamic CCC apparatus was measured with an aqueous mobile phase, the centrifuge spin rate and the mobile phase flow rate being constant, 800 rpm and 2 ml/min, respectively. Conversely, water retention was measured when the 18 solvents were the mobile phases. A direct relationship between the liquid stationary phase retention and the phase density difference was found. The liquid phase density difference is the most important parameter for stationary phase retention in a hydrodynamic CCC apparatus with coiled tubes. The chromatographic retention of formanilide was measured in biphasic systems and expressed as the formanilide partition coefficient. It is shown that the partition coefficient correlates with the Reichardt polarity index of the organic solvent when the liquid stationary phase retention volume does not.  相似文献   

16.
Summary The solvation parameter model is used to characterize the retention properties of a cyanopropylsiloxane-bonded, silica-based sorbent with methanol, acetonitrile, tetrahydrofuran, and isopropanol in water as mobile phases. The system constants over the composition range 1 to 50% (v/v) organic solvent indicate that retention occurs because of the relative ease of cavity formation in the solvated stationary phase compared to the same process in the predominantly aqueous mobile phase as well as from more favorable stationary phase interactions with solutes containing - and n-electrons. The capacity of the solute for dipole-type interactions is not important whereas all hydrogen-bond-type interactions result in reduced retention. Graphing the system constants as a function of mobile phase composition provides a simple mechanism for interpreting the change in capacity of the chromatographic system for retention in terms of changes in the relative weighting of fundamental intermolecular interactions. A comparison is also made with the retention properties of an octadecylsiloxane-bonded, silica-based sorbent with 30% (v/v) methanol in water as the mobile phase and the extraction characteristics of a porous polymer sorbent with 1% (v/v) methanol, acetonitrile, tetrahydrofuran, and isopropanol in water as the sample processing solvent. Changes in sorbent selectivity due to selective uptake of the processing solvent are much smaller for the cyanopropylsiloxane-bonded sorbent than the results found for a porous polymer sorbent.  相似文献   

17.
Organic solvents are traditionally added to micellar mobile phases to achieve adequate retention times and peak profiles, in a chromatographic mode which has been called micellar liquid chromatography (MLC). The organic solvent content is limited to preserve the formation of micelles. However, at increasing organic solvent contents, the transition to a situation where micelles do not exist is gradual. Also, there is no reason to neglect the potentiality of mobile phases containing only surfactant monomers instead of micelles (high submicellar chromatography, HSC). This is demonstrated here for the analysis of β-blockers. The performance of four organic solvents (methanol, ethanol, 1-propanol, and acetonitrile) was compared in mobile phases containing the anionic surfactant sodium dodecyl sulphate in the MLC and HSC modes. The association of the organic solvent molecules with micelles gives rise to a significant loss in the elution strength of the organic solvent; whereas upon disruption of micelles, it tends to that observed in the hydro-organic mode. The elution behaviour of the β-blockers was modelled to predict the retention times. This allowed the detailed exploration of the selectivity and resolution of the chromatographic systems in relatively wide ranges of concentration of surfactant and organic solvent. The best performance in terms of resolution and analysis time was achieved using HSC with acetonitrile, being able to base-line resolve a mixture of eight β-blockers. Ethanol also provided a good separation performance, significantly improved with respect to methanol and 1-propanol. In contrast, the hydro-organic mode using acetonitrile or any of the short-chain alcohols could not succeed with the separation of the β-blockers, owing to the poorer selectivity and wider peaks.  相似文献   

18.
The organic solvent content and the pH in the mobile phase are the usual main factors in reversed-phase liquid chromatographic separations, owing to their strong effects on retention and/or selectivity. Temperature is often neglected. However, even in cases where the impact of this factor on selectivity is minor, the reduction in analysis time is still an interesting reason to consider it. In addition, ionisable compounds may exhibit selectivity changes, owing to the interaction of organic solvent and/or temperature with pH. The separation of ionisable compounds (nine diuretics: bendroflumethiazide, benzthiazide, bumetanide, chlorthalidone, furosemide, piretanide, probenecid, trichloromethiazide and xipamide, and two beta-blockers: oxprenolol and propranolol) exhibiting different acid-base behaviour was studied. The compounds were tested in a Zorbax SB C18 column under a wide range of conditions: 25-45% (v/v) acetonitrile, pH 3-7 and 20-50 degrees C. Models considering two factors (organic solvent/pH and temperature/pH), and three factors (organic solvent/temperature/pH) were developed from a previously reported equation, which considers the polarity contributions of solute, stationary and mobile phases. This allowed a comprehensive method to predict the retention of the 11 compounds, the modification of their acid-base behaviour (i.e. determination of protonation constants and shifts of the retention versus pH curves), and the selectivity changes within the studied factor ranges.  相似文献   

19.
A procedure was developed for the determination of several phenethylamines (amphetamine, arterenol, ephedrine, phenylephrine, phenylpropanolamine, mephentermine, methoxyphenamine, pseudoephedrine and tyramine), using micellar mobile phases of sodium dodecyl sulfate (SDS), a C18 column and UV detection. The drugs were eluted at short retention times with conventional acetonitrile-water or methanol-water mobile phases. In contrast, in the micellar system, they were strongly retained due to association with the surfactant adsorbed on the stationary phase, and needed the addition of butanol or pentanol to be eluted from the column. These modifiers allowed a simple way of controlling the retention. The chromatographic efficiencies obtained with the hybrid mobile phases of SDS-butanol and SDS-pentanol were also very high, mostly in the N=3000-7000 range, significantly greater than those achieved with a conventional acetonitrile-methanol-water mobile phase. Butanol and pentanol yielded similar selectivities, but the latter modifier permitted significantly shorter retention times than butanol, and was preferred to expedite the analysis of the pharmaceuticals. Most binary combinations of the nine phenethylamines can be resolved with these mobile phases. A mobile phase of 0.15 M SDS-5% pentanol was used to assay five of the phenethylamines (amphetamine, ephedrine, phenylephrine, phenylpropanolamine and pseudoephedrine) in 22 pharmaceutical preparations, which contained diverse accompanying compounds. The results agreed with the declared compositions and with those obtained with a mobile phase of methanol-acetonitrile-0.05 M phosphate buffer (pH 3) 10:5:85, with no interferences and relative errors usually below 2%. However, with the aqueous-organic mobile phase, the retention time for phenylephrine was too low and could not be usually evaluated.  相似文献   

20.
The chromatographic behaviors of some basic solutes were evaluated on stationary phases based on poly(methyloctylsiloxane) immobilized onto silica (PMOS-SiO(2)). The test solutes present both hydrophobic and hydrophilic properties. Evaluations of the pH effect used 80:20 v/v methanol/buffered mobile phase over the pH range of 5-11.5 with inorganic buffers such as borate, carbonate and phosphate and with organic buffers such as citrate, tricine and triethylamine. Evaluations in acidic mobile phases used 50:50 v/v and 30:70 v/v methanol/buffer (pH 2.5; 20 mmol/L) mobile phases. The buffer concentration effect used 65:35 v/v methanol/phosphate (pH 7; 20 and 100 mmol/L) mobile phases. The results are compared with those obtained with two chemically bonded stationary phases. The immobilized phases show greater contributions from an ion-exchange mechanism than do the commercial phases. The results indicate that the silanol activity of PMOS-SiO(2) stationary phases can be adequately evaluated by using appropriate basic probes and mobile phases having different pH, using different buffers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏