首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The present study describes the development and validation of a selective liquid chromatographic (LC) method for the analysis of tenofovir disoproxil fumarate (TDF) and its related substances. The gradient method uses a base deactivated C18 column (Hypersil BDS column; 25 cm×4.6 mm I.D.) maintained at a temperature of 30°C. The mobile phases consist of acetonitrile, tetrabutylammonium/phosphate buffer pH 6.0 and water: (A; 2:20:78 v/v/v) and (B; 65:20:15 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 260 nm. Good separation of TDF and 21 impurities was achieved. A system suitability test (SST) to check the quality of separation is also specified. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. The method is proved to be robust, precise, sensitive and linear between 0.1 μg/mL and 0.15 mg/mL. The limit of detection and limit of quantification are 0.03 and 0.1 μg/mL, respectively. The method was successfully applied to the quantification of related substances and assay of commercial TDF samples (bulk substances and tablets).  相似文献   

2.
A reproducible gradient reversed-phase ultra-performance liquid chromatographic method is developed for quantitative determination of duloxetine hydrochloride in pharmaceutical dosage forms. The method is also applicable for analysis of related substances and for study of in vitro dissolution profiles. Chromatographic separation is achieved on a 50 mm × 4.6 mm, 1.8 μm C-18 column. Mobile phase A contains a mixture of 0.01 M KH(2)PO(4) (pH 4.0) buffer, tetrahydro furan, and methanol in the ratio 67:23:10 (v/v/v), respectively, and mobile phase B contains a mixture of 0.01 M KH(2)PO(4), (pH 4.0) buffer, and acetonitrile in the ratio 60:40 (v/v), respectively. The flow rate is 0.6 mL/min, and the detection wavelength is monitored at 236 nm. Resolution of duloxetine hydrochloride and three potential impurities is greater than 2.0 for all pairs of components. The drug was subjected to ICH prescribed hydrolytic, oxidative, photolytic, and thermal stress conditions. Method is validated for linearity, specificity, accuracy, precision, ruggedness, and robustness.  相似文献   

3.
A simple, isocratic, rapid and accurate reversed phase high performance liquid chromatography method was developed for the quantitative determination of tazarotene. The developed method is also applicable for the related substance determination in bulk drugs. The chromatographic separation was achieved on a Hypersil C18 (250 mm × 4.6 mm 5 μm) column using water pH 2.5 with orthophosphoric acid:acetonitrile (15:85, v/v) as a mobile phase. The chromatographic resolutions between tazarotene and its potential impurity A and B were found greater than three. The limit of detection and limit of quantification of impurities were found to be 25 and 75 ng mL−1. The percentage recovery of impurities in bulk drug sample was ranged from 96.8 to 103.5.The percentage recovery of tazarotene in bulk drug sample was ranged from 98.4 to 100.9. The developed RPLC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

4.
A simple and rapid reversed-phase high-performance liquid chromatographic method for monitoring the reactions involved in two different processes for the production of 4-methoxyphenylacetic acid (PMPA) was developed. Impurity profiles of PMPA were used for fingerprinting of the two different synthetic processes by HPLC. Impurities were separated and determined on a Hypersil C18 column with acetonitrile-0.1 M potassium dihydrogen orthophosphate-triethylamine (40:59.95:0.05, v/v) (pH 3.0) as the mobile phase and detection at 280 nm at ambient temperature. The method was substantiated with respect to accuracy, precision, linearity, robustness, limit of detection and quantification. The method was found to be suitable not only for monitoring the reactions but also for quality assurance of PMPA as it could detect impurities at the level of 4 x 10(-9) g.  相似文献   

5.
A stability-indicating liquid chromatographic method has been developed for the quantitative determination of lodenafil carbonate in tablets. The method employs a Synergi Fusion C18 column (250 × 4.6 mm, i.d., 4 μm particle size), with mobile phase consisting of a mixture of methanol-acetic acid 0.1% pH 4.0 (65:35, v/v) and UV detection at 290 nm, using a photodiode array detector. A linear response (r = 0.9999) was observed in the range of 10-80 μg/mL. The method showed good recoveries (average 100.3%) and also intra and inter-day precision (RSD < 2.0%). Validation parameters as specificity and robustness were also determined. Specificity analysis showed that no impurities or degradation products were co-eluting with the lodenafil carbonate peak. The method was found to be stability-indicating and due to its simplicity and accuracy can be applied for routine quality control analysis of lodenafil carbonate in tablets.  相似文献   

6.
A reversed-phase liquid chromatographic (LC) method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical dosage forms. The LC method was carried out on a Synergi fusion C18 column (150 mm x 4.6 mm id) maintained at 45 degrees C. The mobile phase consisted of phosphate buffer 0.03 M, pH 4.5-acetonitrile (35 + 65, v/v) run at a flow rate of 0.6 mL/min, and detection was made using a photodiode array detector at 234 nm. The chromatographic separation was obtained within 15.0 min, and calibration graphs were linear in the concentration range of 0.5-200 microg/mL. Validation parameters such as specificity, linearity, precision, accuracy, and robustness were evaluated, giving results within the acceptable range for both compounds. Moreover, the proposed method was successfully applied for the routine quality control analysis of pharmaceutical products.  相似文献   

7.
Until now no liquid chromatography (LC) method is described to determine the purity and content of troleandomycin and its related substances. A simple, robust, sensitive and selective isocratic liquid chromatographic method suitable for the determination of the antibiotic troleandomycin and its related substances is described. This method utilizes as a stationary phase: XTerra RP18 5 microm (25 cm x 4.6 mm I.D.) at 30 degrees C and as mobile phase: acetonitrile-0.2 M ammonium acetate buffer (pH 6.0)-water (45:5:50, v/v), delivered at a flow-rate of 1.0 ml/min. UV detection is performed at 205 nm. Troleandomycin is separated from the partially acetylated related substances and from several unknown impurities present in commercial samples. The robustness of the method was evaluated by a full-factorial experimental design.  相似文献   

8.
A selective reversed-phase (RP) liquid chromatographic (LC) method coupled with UV for the determination of tylosin and its related substances is described. The gradient method uses a Capcell pak C18 ACR column (25 cm×4.6 mm id, 5 μm) maintained at a temperature of 60°C. The mobile phases consist of acetonitrile, phosphate buffer pH 5.5 and water: (A; 27.5:10:62.5 v/v/v) and (B; 50:10:40 v/v/v). The flow rate is 1.0 mL/min and UV detection is performed at 280 nm. It allows the separation of all known and 22 other unknown related substances (≥0.02%) from the main compound and from one another. The method shows good precision, sensitivity, linearity (between 0.2 μg/mL and 1.25 mg/mL) and robustness. The limit of quantification is 0.2 μg/mL, corresponding to 0.020%. Seven bulk tylosin samples containing a large number of impurities were examined using this method.  相似文献   

9.
Quantitative high-performance liquid chromatographic (HPLC) and micellar electrokinetic chromatographic (MEKC) methods have been developed for the determination of four structurally related potential manufacturing impurities, including morphine, of the opiate derivative pholcodine. Pholcodine and the four impurities were separated by MEKC in less than 14 min using a 70 cm x 75 microm I.D. uncoated fused-silica capillary (25 kV at 30 degrees C) and a running buffer consisting of 10% acetonitrile (v/v) in 20 mM borate-phosphate buffer pH 8.0 containing 40 mM sodium dodecyl sulphate (SDS). The MEKC method was compared to a HPLC method using a 5 microm Luna phenyl-hexyl column (150 x 4.6 mm I.D.) eluted with a mobile phase consisting of a mixture of 10% (v/v) acetonitrile, 7% (v/v) tetrahydrofuran in 20 mM phosphate buffer pH 8.0. Both methods were fully validated and a comparison was made regarding selectivity, linearity, precision, robustness and limits of detection and quantitation. The presence of the impurities in different samples of pholcodine drug substance was investigated using both methods.  相似文献   

10.
A new and simple isocratic high-performance liquid chromatographic method with ultraviolet detection is described for simultaneous determination of active guaiphenesin and preservative sodium benzoate in Liqufruta garlic cough medicine formulation. The chromatographic separation was achieved using a Zorbax CN; 150 mm × 4.6 mm and 5 μm particle size column employing acetonitrile and water (20: 80, v/v) containing 0.1% formic acid (pH 3.5 ± 0.05) as the mobile phase. The method was validated with respect to linearity, range, precision, accuracy, specificity, limit of detection and limit of quantitation. The both analytes were detected by UV-Vis detector at 245 nm. The method was linear over the concentration range of 0.2–0.8 mg/mL and 0.02–0.06 mg/mL for guaiphenesin and sodium benzoate, respectively. The limit of detection was found to be 0.14 μg/mL for GP and 0.06 μg/mL for SB and the quantification limit was 0.54 μg/mL for GP and 0.22 for SB. Accuracy, evaluated as recovery, was in the range of 97.8–100.0%. Intra-day precision and intermediate precision showed relative standard deviation <1% in each case.  相似文献   

11.
A rapid, precise, accurate, and selective high-performance liquid chromatographic method with fluorescence detection has been validated and used for analysis of amisulpride in human plasma after a simple solid-phase extraction procedure. Compounds were separated on a CN column with 0.03?M potassium dihydrogen phosphate (pH 6.5)-acetonitrile 65:35 (v/v) as mobile phase. Fluorescence detection was performed at excitation and emission wavelengths of 274 and 370?nm, respectively. Calibration plots were linear over the concentration range 10-1,000?ng?mL(-1) in human plasma, and the lower limit of quantification was 10?ng?mL(-1). Accuracy was between 0.4 and 6.4% and precision was between 3.1 and 7.5%. Amisulpride was sufficiently stable through three freeze-thaw cycles, during storage for 6?h at room temperature, and for 2?months at -22?°C. The method is suitable for the analysis of clinical samples from pharmacokinetic studies.  相似文献   

12.
An accurate, reproducible, and sensitive method for the determination of buspirone HCl and its potential impurities is developed and validated. The validated liquid chromaography method is conducted to meet the Food and Drug Administration/ International Conference on Harmonization requirements for the analysis of buspirone HCI in the presence of its impurities. Five buspirone HCI potential impurities, including 1-(2-pyrimidinyl)-piperazine (I), propargyl chloride (II), 3,3'-tetramethylene glutarimide (III), propargyl glutarimide (IV), and the Mannich base-condensate of I-IV fumarate (V), are separated using a microBondapack C18 column by gradient elution with a flow rate 2.0 mL/min. The initial mobile phase composition is 90:10 (v/v) 10mM KH2PO4 (pH 6.1)-acetonitrile. After a 1-min initial hold, a linear gradient is performed in 26 min to 35:65 (v/v) 10mM KH2PO4 (pH 6.1)-acetonitrile. The samples are detected at 210 and 240 nm using a photo-diode array detector. The linear range of detection for buspirone HCI was between 1.25 ng/microL and 500 ng/microL, with a limit of quantification of 1.25 ng/microL. The linearity, range, peak purity, selectivity, system performance parameters, precision, accuracy, and robustness for all of the impurities were also shown to have acceptable values.  相似文献   

13.
Summary An improved LC method is described for the separation of oxytetracycline and its impurities. The separation is much better than that obtained with official pharmacopoeia methods. The method uses XTerra RP-18, 5 μm (25cm×4.6 mm I.D.), a silica-based stationary phase with methyl end-capping, claimed to reduce silanol activity. The column temperature is set at 30°C and a UV detection is performed at 280 nm. Mobile phase containing acetonitrile −0.25 M tetrabutylammonium hydrogen sulfate pH 7.5−0.25 M ethylenediaminetetraacetic acid pH 7.5-water (115:360:160:365,v/v/v/v) is used at a flow rate of 1.0 mL.min−1, to separate the impurities present in oxytetracycline base. A central composite experimental design is used to optimize the separation. A second isocratic method with higher content of acetonitrile is needed to separate the more retained impurities present only in oxytetracycline hydrochloride. The method is robust and shows good selectivity, repeatability, linearity and sensitivity.  相似文献   

14.

A simple, rapid, isocratic, and versatile liquid chromatographic method was developed for the simultaneous determination of bromhexine, guaifenesin, ambroxol, salbutamol/terbutaline, pseudoephedrine, triprolidine, and chlorpheniramine maleate in cough–cold syrups commonly marketed in Kenya. Separation was achieved using a Gemini® NX C18 column (250 × 4.6 mm, 5 μm) maintained at 40 °C and a mobile phase consisting of acetonitrile-0.25 M sodium hexanesulphonate-0.2 M ammonium acetate, and pH 3.0-water (35:4:10:51, % v/v/v/v) delivered at 1.0 mL min−1. The eluents were monitored by means of UV detection at 254 nm. During validation, the method satisfied the International Committee on Harmonization acceptance criteria for linearity, sensitivity, precision, accuracy, and robustness. The developed liquid chromatographic method was applied in the analysis of nine commercial samples obtained from Nairobi City County, Kenya. Extraction procedures were not applied during the assay of the samples, thus significantly shortening the analysis time.

  相似文献   

15.
Trimetazidine dihydrochloride is an anti-anginal drug, which possesses protective properties against ischemia inducing heart damage. In this paper, a new procedure for liquid chromatographic analysis was successfully developed, optimized, and applied in assessment of trimetazidine dihydrochloride content and its impurities, Y-145, Y-235, and Y-234 at most 1.0%, 0.2%, and 0.2%, respectively, in commercially available pharmaceutical preparation containing 35 mg of trimetazidine dihydrochloride. The retention behavior of trimetazidine dihydrochloride and its impurities is investigated by using several stationary and mobile phases to settle a simple, sensitive, and precise RP-HPLC method. The separation conditions are optimized by DryLab 2000 Plus Chromatography Optimization Software version 3.5.00. Separations are performed on PurospherSTAR RP18 endcapped (150 x 4.6 mm, 5 microm particle size) column at 20 degrees C with UV detection at 210 nm. The mobile phase composition is acetonitrile-aqueous phase (10 mmol/L disodium hydrogenphosphate and 2 mmol/L sodium dihydrogen phosphate, pH 7.6) (30:70 v/v). Afterwards, the method is validated; the important statistical parameters for selectivity/specificity, linearity, precision, limit of detection, and quantitation are defined. The recovery value of the trimetazidine dihydrochloride is 98.06%, and the content of impurities is 0.23% for Y-145, less than 0.02% for Y-235, and less than 0.01% for Y-234. In addition, this method is used for analyzing trimetazidine dihydrochloride and its impurities in pharmaceuticals and bulk drug.  相似文献   

16.
A reversed-phase high-performance liquid chromatographic method for simultaneous separation and determination of citalopram hydrobromide and its process impurities in bulk drugs and pharmaceutical formulations was developed. The separation was accomplished on an Inertsil ODS 3V (250x4.6 mm; particle size 5 mum) column using 0.3% diethylamine (pH = 4.70) and methanol/acetonitrile (55:45 v/v) as mobile phase in a gradient elution mode. The eluents were monitored by a photodiode array detector set at 225 nm. The chromatographic behavior of all the related substances was examined under variable conditions of different solvents, buffer concentrations, and pH. The method was validated in terms of accuracy, precision, and linearity. The method could be of use not only for rapid and routine evaluation of the quality of citalopram in bulk drug manufacturing units but also for the detection of its impurities in pharmaceutical formulations. Three unknown impurities were consistently observed during the analysis of different batches of citalopram. Forced degradation of citalopram was carried out under thermal, photo, acidic, alkaline, and peroxide conditions. The degradation products and unknown impurities were isolated and characterized by ESI-MS/MS, (1)H NMR, and FT-IR spectroscopy.  相似文献   

17.
A simple, linear gradient, rapid, precise and stability-indicating analytical method was developed for the estimation of related substances and degradants of paliperidone API and tablets. The chromatographic separations were achieved using an Acquity ultra-performance liquid chromatograph (BEH 100 mm, 2.1 mm, 1.7 μm C-18 column) employing 0.01 M potassium dihydrogen phosphate buffer (pH 2.0) as mobile phase A and acetonitrile-water (9:1) as mobile phase B. A linear gradient (mobile phase A, mobile phase B in the ratio of 84:16) with a 0.45 mL/min flow rate was chosen. All six impurities were eluted within five minutes of run time. The column temperature was maintained at 25 °C and a detector wavelength of 238 nm was employed. Paliperidone was exposed to thermal, photolytic, hydrolytic and oxidative stress conditions. The stressed samples were analyzed by the proposed method. Considerable degradation of the analyte was observed when it was subjected to oxidative conditions and impurity F was found to be the major degradant. Peak homogeneity data of paliperidone obtained by photodiode array (PDA) detection demonstrated the specificity of the method in the presence of degradants. The method was validated with respect to linearity, precision, accuracy, ruggedness, robustness, limit of detection and limit of quantification.  相似文献   

18.
A simple and sensitive high-performance liquid chromatographic method for a routine assay of gliclazide in serum is described. Serum samples spiked with glibenclamide (internal standard) were applied to Bond Elut C18 cartridges. After washing with phosphate buffer (pH 7.5) and water, the cartridge was eluted with 60% methanol. The eluate was evaporated to dryness. The residue was dissolved in methanol and injected onto an octadecyl silica column (5 microns, 150 mm x 4.6 mm I.D.). The mobile phase was 0.04 M potassium dihydrogenphosphate (pH 4.6)-acetonitrile-isopropyl alcohol (5:4:1, v/v). Ultraviolet detection at 227 nm was used. The minimum detectable level of gliclazide was 20 ng/ml.  相似文献   

19.
A confirmatory high-pressure liquid chromatographic method for the determination of nine tetracyclines in Sparus aurata (gilthead seabream) muscle tissue is developed and presented herein. Tetracycline, 4-epi-tetracycline, oxytetracycline, 4-epi-oxytetracycline, chlortetracycline, 4-epi-chlortetracycline, doxycycline, methacycline and demeclocycline were separated on a Kromasil, C18 (250 mm × 4 mm, 5 μm) analytical column by gradient elution with a mobile phase consisting of 0.001 M ethylenediaminetetraacetic acid/sodium salt and acetonitrile at 25°C. Diode array detection with monitoring at 280 nm (for the determination of chlortetracycline, 4-epi-chlortetracycline, methacycline and demeclocycline) and 355 nm (for tetracycline, 4-epi-tetracycline, oxytetracycline, 4-epi-oxytetracycline and demeclocycline) was applied for peak identification and quantification of analytes. Examined antibiotics were isolated from gilthead seabream tissue by leaching using a citrate buffer (pH 4.0) and purified by solid phase extraction using Oasis HLB(200 mg/6 mL) cartridges. The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability and sensitivity according to the European Union Decision 2002/657/EC.  相似文献   

20.
A new, specific, and sensitive RP-HPLC method was developed for the simultaneous determination of eprosartan (EPR) and hydrochlorothiazide (HCT). Good chromatographic separation was achieved using a 250 x 4.6 mm id, 5 microm particle size Symmetry C18 column. The mobile phase acetonitrile-0.1 M phosphate buffer (35+65, v/v), pH 4.5, was pumped at a flow rate of 1 mL/min, with UV detection at 275 nm. The method showed good linearity in the ranges of 0.5-50 and 0.1-10 microg/mL, with LOD of 0.06 and 0.02 microg/mL and LOQ of 0.20 and 0.08 microg/mL for EPR and HCT, respectively. The proposed method was successfully applied for the analysis of the studied drugs in their synthetic mixture and co-formulated tablets. The method was further extended to the in vitro and in vivo determination of the two drugs in spiked and real human plasma. Interference likely to be encountered from the co-administered drugs was studied.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号