首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A method for the simultaneous quantification of reduced and oxidized glutathione in human plasma employing a two-dimensional chromatographic system with parallel porous graphitized carbon (PGC) columns coupled with fluorescence (FLD) and coulometric electrochemical detection (ED) has been developed. Post-sampling oxidation of reduced glutathione (GSH) was prevented by derivatizing the -SH group with monobromobimane (MBB) and the glutathione-bimane adduct (GSMB) was detected by FLD. Oxidized glutathione (GSSG) was detected by ED optimized to give lowest possible limits of detection (LOD). The method is fully validated and is currently used for determination of GSH, GSSG and its redox potential in different clinical studies.  相似文献   

2.
Glutathione (GSH), glutathione disulfide (GSSG), and ophthalmic acid (OA) are important biological oxidative stress biomarkers to be monitored in pathological and toxicological studies. With the advent of liquid chromatography tandem mass spectrometry (LC-MS-MS) technology, sensitive and selective analysis of these biomarkers in biological samples is now being performed routinely. Due to the hydrophilic and polar natures of GSH and its endogenous derivatives, achieving good retention, resolution, and peak shape is often a chromatographic challenge. In this study, three ultra-performance (UP) LC column chemistries (namely, BEH C18, BEH HILIC, and HSS T3 [C18]) are evaluated for the UPLC-MS-MS analysis of GSH, GSSG, and OA extracted from mouse liver and human plasma samples. The chromatographic parameters evaluated are retentivity, tailing factor, MS sensitivity, and resolution of the three analytes. Based on the optimized method for each column chemistry, our results indicate that the HSS T3 (C18) column chemistry affords the best retention and separation of these analytes when operated under the ultra high-pressure chromatographic conditions.  相似文献   

3.
Measurement of glutathione (GSH) and glutathione disulfide (GSSG) is a crucial tool to assess cellular redox state. Herein we report a direct approach to determine intracellular GSH based on a rapid chromatographic separation coupled with acidic potassium permanganate chemiluminescence detection, which was extended to GSSG by incorporating thiol blocking and disulfide bond reduction. Importantly, this simple procedure avoids derivatisation of GSH (thus minimising auto-oxidation) and overcomes problems encountered when deriving the concentration of GSSG from 'total GSH'. The linear range and limit of detection for both analytes were 7.5 × 10(-7) to 1 × 10(-5) M, and 5 × 10(-7) M, respectively. GSH and GSSG were determined in cultured muscle cells treated for 24 h with glucose oxidase (0, 15, 30, 100, 250 and 500 mU mL(-1)), which exposed them to a continuous source of reactive oxygen species (ROS). Both analyte concentrations were greater in myotubes treated with 100 or 250 mU mL(-1) glucose oxidase (compared to untreated controls), but were significantly lower in myotubes treated with 500 mU mL(-1) (p < 0.05), which was rationalised by considering measurements of H(2)O(2) and cell viability. However, the GSH/GSSG ratio in myotubes treated with 100, 250 and 500 mU mL(-1) glucose oxidase exhibited a dose-dependent decrease that reflected the increase in intracellular ROS.  相似文献   

4.
For the determination of glutathione (GSH) and its oxidized form (GSSG) in spruce needles their electrospray mass and MS/MS spectra were recorded with an ion trap mass spectrometer (ITMS, LCQ, Finnigan) and a triple stage quadrupole mass spectrometer (TSQ, Quattro II, Micromass). A study of the stability of GSH in aqueous solutions shows the presence of dimeric and trimeric forms of GSH, as well as GSSG, GSH-sulfonate and GSH-sulfinic acid. The same components were also found in extracts of spruce needles. We developed an assay which is suitable for monitoring low concentrations of GSH and similar compounds in plant tissues, employing the sensitivity and specificity of LC/MS/MS. Preliminary results on the mass spectrometric determination of GSH in spruce needles are given.  相似文献   

5.
Oxidation of glutathione (GSH) to glutathione disulfide (GSSG) occurs during cellular oxidative stress. The redox potential of the 2GSH/GSSG couple, which is determined by the Nernst equation, provides a means to assess cellular redox status. It is difficult to accurately quantify GSH and GSSG due to the ease with which GSH is oxidized to GSSG during sample preparation. To overcome this problem, a stable isotope dilution liquid chromatography/multiple reaction monitoring mass spectrometry (LC/MRM-MS) method has been developed using 4-fluoro-7-sulfamoylbenzofurazan (ABD-F) derivatization. ABD-F derivatization of the GSH thiol group was rapid, quantitative, and occurred at room temperature. The LC/MRM-MS method, which requires no sample clean-up, was validated within the calibration ranges of 5 to 400 nmol/mL in cell lysates for GSH and 0.5 to 40 nmol/mL in cell lysates for GSSG. Calibration curves prepared by adding known concentrations of GSH and GSSG to cell lysates were parallel to the standard curve prepared in buffers. GSH and GSSG concentrations were determined in two monocyte/macrophage RAW 267.4 cell lines with or without 15-LOX-1 expression (R15LO and RMock cells, respectively) after treatment with the bifunctional electrophile 4-oxo-2(E)-nonenal (ONE). R15LO cells synthesized much higher concentrations of the lipid hydroperoxide, 15(S)-hydroperoxyeicosatetraenoic acid (15-HPETE), which undergoes homolytic decomposition to ONE. GSH was depleted by ONE treatment in both RMock and R15LO cells, leading to significant increases in their redox potentials. However, R15LO cells had higher GSH concentrations (most likely through increased GSH biosynthesis) and had increased resistance to ONE-mediated GSH depletion than RMock cells. Consequently, R15LO cells had lower reduction potentials at all concentrations of ONE. GSSG concentrations were higher in R15LO cells after ONE treatment when compared with the ONE-treated RMock cells. This suggests that increased expression of 15(S)-HPETE modulates the activity of cellular GSH reductases or the transporters involved in removal of GSSG.  相似文献   

6.
Glutathione (GSH), glutathione disulfide (GSSG) and 2‐hydroxyethylated glutathione (HESG) are important biomarkers for exploring the genotoxicity mechanism of ethylene oxide (EO) or ethylene in vivo. A liquid chromatography–tandem mass spectrometry method was developed for simultaneous determination of GSH, GSSG and HESG in mouse lung tissues after inhalation exposure to EO. The lower limit of quantitation for all these biomarkers was 0.002 µg/mL. The linearity of the calibration curves for all analytes was >0.998. The intra‐day assay precision relative standard deviation (RSD) values for quality control samples for all analytes were ≤12.8% with accuracy values ranging from 87.2 to 113%. The inter‐day assay precision (RSD) values for all analytes were ≤13.1% with accuracy values ranging from 86.9 to 103%. This method was applied to concurrently determine the levels of GSH, GSSG and HESG in lung samples isolated from mouse after 4‐week inhalation exposure to EO at 0, 10, 50, 100 and 200 ppm. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
Hepatotoxicity of drug candidates is one of the major concerns in drug screening in early drug discovery. Detection of hepatic oxidative stress can be an early indicator of hepatotoxicity and benefits drug selection. The glutathione (GSH) and glutathione disulfide (GSSG) pair, as one of the major intracellular redox regulating couples, plays an important role in protecting cells from oxidative stress that is caused by imbalance between prooxidants and antioxidants. The quantitative determination of the GSSG/GSH ratios and the concentrations of GSH and GSSG have been used to indicate oxidative stress in cells and tissues. In this study, we tested the possibility of using the biliary GSSG/GSH ratios as a biomarker to reflect hepatic oxidative stress and drug toxicity. Four compounds that are known to alter GSH and GSSG levels were tested in this study. Diquat (diquat dibromide monohydrate) and acetaminophen were administered to rats. Paraquat and tert-butyl hydroperoxide were administered to mice to induce changes of biliary GSH and GSSG. The biliary GSH and GSSG were quantified using calibration curves prepared with artificial bile to account for any bile matrix effect in the LC–MS analysis and to avoid the interference of endogenous GSH and GSSG. With four examples (in rats and mice) of drug-induced changes in the kinetics of the biliary GSSG/GSH ratios, this study showed the potential for developing an exposure response index based on biliary GSSG/GSH ratios for predicting hepatic oxidative stress.  相似文献   

8.
Li  Min  Mao  Sifeng  Wang  Shiqi  Li  Hai-Fang  Lin  Jin-Ming 《中国科学:化学(英文版)》2019,62(1):142-150
Alterations in the ratio of glutathione(GSH) to glutathione disulfide(GSSG) reveal the cell living state and are associated with a variety of diseases. In this study, an Au NPs grafted nanoporous silicon chip was used for surface assisted laser desorption ionization-mass spectrometry(SALDI-MS) detection of GSH. Due to the bond interaction between thiol of GSH and Au NPs modified on the chip surfaces, GSH could be captured from the complex cellular lysate. Meanwhile, the composite nanostructures of Au NPs grafted porous silicon surface presented good desorption/ionization efficiency for GSH detection. The GSH levels in different tumor cells were successfully detected. Chip-based SALDI-MS was optimized for quantification of intracellular GSH/GSSG ratio changing under drug stimulation in liver tumor cells, GSSG was reduced to GSH by reductant of tris(2-carboxyethyl)phosphine(TCEP) and isotope-labeling GSH was as an internal standard. It was found that the increasing concentration of drug irinotecan and hypoxia culture condition caused the rapid consumption of GSH and a decrease of GSH/GSSG ratio in liver tumor cells. The developed SALDI-MS method provided a convenient way to accurately measure and rapidly monitor cellular GSH value and the ratios of GSH/GSSG.  相似文献   

9.
Glutathione (GSH) and glutathione disulfide (GSSG) levels in cells constitute a thiol redox system. They can be used as an indicator of oxidative stress of the cell. In this study, a capillary zone electrophoresis (CZE) method is described that enables quantitation of GSH and GSSG from cellular extracts. The CZE buffer used was 20 mM ammonium acetate containing 5% (v/v) acetic acid at pH 3.1 in conjunction with a polybrene coated capillary operated in reverse polarity mode. Effects of different acids used to prepare cell samples were investigated on CZE performance. The acids include meta phosphoric acid (MPA), trichloroacetic acid (TCA), phosphoric acid (PA) and sulfosalicylic acid (SSA) and are used to stabilize GSH and GSSG before performing CZE analysis. The method features a limit of detection of 4 microM and a limit of quantitation of 12 microM for both GSSG and GSH and recoveries of 94% for GSH and 100% for GSSG. Quantitative analysis of GSSG and GSH in HaCaT cell extracts (5% SSA, w/v) was performed with this method and changes in the ratio of GSH to GSSG in N-ethylmaleimide treated cell sample was observed by comparing with control cell samples.  相似文献   

10.
A rapid method of capillary zone electrophoresis is described to determine the oxidized (GSSG) and reduced (GSH) form of glutathione in plant tissue. In order to separate both analytes in a fused-silica capillary, the pH and composition of the electrolyte solution were optimized. The electrolyte composition was 100 mmol/L, borate 25 mmol/L Tris, and 0.2% w/v metaphosphoric acid (MPA), pH 8.2. Some instrumental conditions used to run the samples were hydrostatic injection for 30 s, 30 kV applied voltage, and UV detection (185 nm) at 25 degrees C. Linearity and useful range obtained for the calibration curves were optimum, with correlation coefficients about 0.999 in the 0-120 micromol/L range. The migration time was highly reproducible, less than 5 min being afforded to run a sample. Electrolyte buffer and samples required a careful pH control for optimal separation of both analytes. This aspect constitutes a critical analytical step when acids are used in the procedure for sample preparation. Simultaneous analysis of GSH and GSSG may provide a useful tool for comparative studies of plants in order to select those species with a potential capacity for detoxification from toxic elements or those appearing promising from phytoremediation for these elements.  相似文献   

11.
The present work was aimed to the development of a fluorescence assay using the universal 96-well microplate format, for the measurement of reduced glutathione (GSH) in yeast cells. The method relies upon the reaction between GSH and a highly selective fluorogenic probe, i.e. naphthalene-2,3-dicarboxaldehyde (NDA). The optimization of the method included the extraction step of GSH from cultured yeast cells in a cold perchloric acid solution, derivatization conditions (10-min reaction at pH 8.6 and at 20 ± 2 °C in darkness) and stability studies of the resulting fluorescent adduct. Full selectivity was observed versus other endogenous thiols (except for γ-glutamylcysteine), glutathione disulfide (GSSG) and enzymatic reducing reagents of GSSG. Linearity was verified in the range 0.3-6.5 μM (R2 > 0.98) and limits of quantification and detection were 0.3 and 0.05 μM, respectively. Relative standard deviation corresponding to repeatability (n = 3) and inter-day precision (n = 5) were 2.8 and 6.1%, respectively. Mean GSH recovery from cell extracts was 95%. The method appeared highly correlated (R2 = 0.96) with a previously reported HPLC method.The method was then applied to the monitoring of GSH in the yeast strain Kluyveromyces lactis during its growth period and in the presence of an inhibitor of GSH biosynthesis. The method presents the main advantage of a high throughput for the measurement of biological samples. The extent of the method to the study of the redox couple GSSG/GSH by including an enzymatic reduction step and the enhancement of the fluorescence signal using cyclodextrins were discussed.  相似文献   

12.
Flavonoids are natural compounds in medicinal herbs and posses several biological activities important in plant drug design. Especially strong antioxidant effects play an important role against radical oxidative stress causing pathological processes, such as arteriosclerosis or cancer. The aim of this work was to investigate unknown analytes found in sorrel leaf (Rumex acetosa) extracts in order to discover new leading compounds to enable quality control in phytopharmaceuticals made thereof. Therefore compounds of interest were separated after methanolic extraction by reversed-phase liquid chromatography (RP-LC) employing silica-C18 as stationary phase using gradient elution with water (10 mM H3PO4) and acetonitrile as mobile phase. Structural elucidation was carried out by diode array, fluorescence, and mass spectroscopic detection. Photodiode-array detection allowed the extraction of UV-absorbance spectra from the peaks of interest. Absorbance maxima were found at 203 and 279 nm with a shoulder at 230 nm. Additionally fluorescence emission and excitation spectra were recorded from the analytes using a fluorescence detector (FLD) after stop flow (lambdaex = 279 nm, lambdaem = 307 nm). The chromatographic reversed-phase system was coupled to an ion-trap mass spectrometer (LC-MS) by using an electrospray ionization interface (ESI). After optimization processes the separation was carried out using an ammonium acetate buffer at pH 5.5. Mass spectrometric detection turned out to be more sensitive in negative mode. Collisionally induced dissociation (CID) was used to obtain fragment ions of structural relevance (LC-MS/MS). Finally, compounds of interest coming from sorrel leaf (Rumex acetosa) eluting at low acetonitrile concentrations were confirmed to be catechin and epicatechin.  相似文献   

13.
A method for the separation of reduced (GSH) and oxidized (GSSG) glutathione was optimized in terms of buffer concentration, sodium dodecyl sulfate concentration, buffer pH, detection wavelength, run voltage and injection volume. The method demonstrated good linearity (r2 > 0.999) and reproducibility (internal standard corrected peak area RSD < 2.3%) in the range of interest (16-81 microM GSH and 8-40 microM GSSG). A detection limit of less than 1 microM GSH and GSSG was obtained using a high sensitivity flow cell. When the optimized method was applied to plasma samples, concentrations of 1.6 microM GSH and 0.8 microM GSSG were easily detected without the need for derivatization. The on-capillary detection was calculated to be 38.6 fmol of GSH and 18.3 fmol of GSSG.  相似文献   

14.
We describe a very rapid high-performance capillary electrophoresis method for the separation and quantification of reduced (GSH) and oxidized (GSSG) glutathione in red blood cells. Two procedures for sample preparation have been compared, Microcon-10 membrane filtration and acid precipitation. The separation is obtained in an uncoated capillary using a high ionic strength borate buffer at pH 7.8. The intra-assay coefficients of variation (CVs%) are 1.53 and 1.66 for GSH and GSSG, respectively. The run is shorter than 90 s and the migration time is highly reproducible both for GSH (CV% 0.22) and GSSG (CV% 0.17). When the filtration step is used only GSH is found, whereas both GSH and GSSG are detectable after acid precipitation, suggesting that GSSG revealed after acid treatment may be an artefact due to GSH oxidation. Because of its good analytical performance this method could be used for routine red blood cell glutathione measurement in healthy or pathological conditions.  相似文献   

15.
A novel analytical method using liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) was developed for measuring the fractional synthesis rate (FSR) of glutathione (GSH) in neonates after infusion of [1-(13)C]-glycine as a tracer. After transformation of GSH into GSSG, its dimeric form, the intra-erythrocytic concentration and (13)C-isotopic enrichment of GSH were determined using 200 microL of blood. The results showed that, using LC/IRMS, the concentration (range of micromol/mL) was reliably measured using norvaline as internal standard with precision better than 0.1 micromol/mL. In addition, the (13)C-isotopic enrichment measured in the same run gave reliable values with excellent precision (with standard deviation (sd) lower than 0.3 per thousand) and accuracy (measured between 0 and 2 Atom % Excess (APE)). The inter-assay repeatability of delta(13)C of norvaline used as internal standard with in vivo samples was assessed at -26.07 +/- 0.28 per thousand with coefficient of variance (CV) at 1.1%. The FSR calculated either with GSH or GSSG showed similar results with slightly higher values for GSSG (41.6 +/- 4.7 and 46.5 +/- 4.4, respectively). The slightly lower FSR of GSH is probably due to interfering compounds in the biological matrix. Successfully used in a clinical study, this rapid and reliable method opens up a variety of kinetic studies with relatively low administration of tracer infusates, reducing the total cost of the study design. The small volume of blood needed enables studies even in extremely small subjects, such as premature infants, as reported in this study.  相似文献   

16.
Endogenous glutathione (GSH) and glutathione disulfide (GSSG) status is highly sensitive to oxidative conditions and have broad application as a surrogate indicator of redox status in vivo. Established methods for GSH and GSSG quantification in whole blood display limited utility in human plasma, where GSH and GSSG levels are ~3–4 orders of magnitude below those observed in whole blood. This study presents simplified sample processing and analytical LC–MS/MS approaches exhibiting the sensitivity and accuracy required to measure GSH and GSSG concentrations in human plasma samples, which after 5-fold dilution to suppress matrix interferences range from 200 to 500 nm (GSH) and 5–30 nm (GSSG). The utility of the methods reported herein is demonstrated by assay performance and validation parameters which indicate good sensitivity [lower limits of quantitation of 4.99 nm (GSH) and 3.65 nm (GSSG), and high assay precision (intra-assay CVs 3.6 and 1.9%, and inter-assay CVs of 7.0 and 2.8% for GSH and GSSG, respectively). These methods also exhibited exceptional recovery of analyte-spiked plasma samples (98.0 ± 7.64% for GSH and 98.5 ± 12.7% for GSSG). Good sample stability at −80°C was evident for GSH for up to 55 weeks and GSSG for up to 46 weeks, with average CVs <15 and <10%, respectively.  相似文献   

17.
The identification of a glutathione (GSH) fumarate conjugate, dicarboxyethyl glutathione, formed during the nonenzymatic succination of GSH by fumarate was confirmed in fumarate hydratase deficient cells using a product ion scan approach followed by hydrophilic interaction liquid chromatography coupled with MS/MS. GSH and its conjugates, including dicarboxyethyl glutathione and glutathione disulfide, were successfully separated on a zwitterionic stationary phase and detected by MS/MS operated under negative ESI mode. The relative quantitation of the analytes in cell extracts was carried out and a correction model was established to determine correction factors under matrix effects and the response mismatch between the analytes. These factors were calculated and iteratively used to measure all analytes in cell extracts, based on calibration curves constructed in neat solution. The model was a closed‐loop calculation, consisting of two sides with each side of the loop presenting a calculation pathway. Deviation of the correction factors obtained from these pathways manifested the model accuracy. The model was evaluated and there was no significant difference between the two pathways.  相似文献   

18.
A new approach has been developed for the direct determination of reduced (glutathione [GSH]) and oxidized (glutathione disulfide [GSSG]) GSH in whole blood by means of capillary electrophoresis. Its features include GSH-stabilizing sample preparation, the use of an internal standard, and pH-mediated stacking. Blood stabilized with acid citrate and K3EDTA was treated with acetonitrile with N-ethylmaleimide, and then the analytes were extracted with diethyl ether. The total analysis time was 8 min using a 50-µm (i.d.) by 32.5-cm (eff. length) silica capillary. The background electrolyte was 0.075-M citrate Na pH 5.8 with 200-µM cetyltrimethylammonium bromide and 5-µM sodium dodecyl sulfate, and the separation voltage was −14 kV. The quantification limit (S/N = 15) of the method was 1.5 µM for GSSG. The accuracy levels of GSH and GSSG analysis were 104% and 103%, respectively, and between-run precision levels were 2.6% and 3.2%, respectively. Analysis of blood samples from healthy volunteers (N = 24) showed that the levels of GSH and GSSG and the GSH/GSSG ratio in the whole blood were 1.05 ± 0.14 mM, 3.9 ± 1.25 µM, and 256 ± 94, respectively. Thus, the presented approach can be used in clinical and laboratory practice.  相似文献   

19.
Zhang J  Hu Z  Chen X 《Talanta》2005,65(4):986-990
A new capillary electrophoresis (CE) method with laser-induced fluorescence (LIF) detection was developed for the rapid separation and sensitive detection of glutathione (GSH) and glutathione disulfide (GSSH) after derivatization by 4-chloro-7-nitrobenzo-2-oxa-1,3-diazol (NBD-Cl). The derivatization and separation conditions were investigated in detail and the optimums were obtained. Under the optimum experiment conditions, linear relationships between the peak height and concentrations of the analytes in normal and second-derivative electrophoregrams were obtained (0.22-45.00 μM). The detection limits for glutathione and glutathione disulfide in normal and second-derivative electrophoregrams were 0.046 and 0.012 μM and 0.046 and 0.014 μM, respectively. The method was applied to the analysis of glutathione and glutathione disulfide in human plasma and tobacco leaves with satisfactory results.  相似文献   

20.
The paper presents the development of an advanced extraction and fast analytical LC MS/MS method for simultaneous analyses of reduced and oxidized glutathione (GSH and GSSG, respectively) in different animal tissues. The simultaneous determination of GSH and GSSG is crucial because the amount and ratio of both GSH and GSSG may be altered in response to oxidative stress, an important mechanism of toxicity. The method uses the derivatization of free thiol groups in GSH. Its performance was demonstrated for less explored tissues (lung, brain, and liver) in mouse. The combined extraction and analytical method has very low variability and good reproducibility, maximum coefficients of variance for within-run and between-run analyses under 8 %, and low limits of quantification; for GSH and GSSG, these were 0.2 nM (0.06 ng/mL) and 10 nM (6 ng/mL), respectively. The performance of the method was further demonstrated in a model experiment addressing changes in GSH and GSSG concentrations in lung of mice exposed to CdO nanoparticles during acute 72 h and chronic 13-week exposures. Inhalation exposure led to increased GSH concentrations in lung. GSSG levels were in general not affected; nonsignificant suppression occurred only after the longer 13-week period of exposure. The developed method for the sensitive detection of both GSH and GSSG in very low tissue mass enables these parameters to be studied in cases where only a little sample is available, i.e. in small organisms or in small amounts of tissue.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号