首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Jahangiri  Shima  Hatami  Mehdi  Farhadi  Khalil  Bahram  Morteza 《Chromatographia》2013,76(11):663-669

A sensitive and simple method based on two-phase liquid-phase microextraction in porous hollow fiber followed by gas chromatography-flame ionization detection was developed for quantification and pharmacokinetic study of valproic acid (VPA, an antiepileptic drug) in rat plasma after oral administration of pure sodium valproate (25 mg kg−1). Some parameters such as type of organic solvent, pH of sample solution, stirring speed, salt addition, extraction time, and volume of sample that affected extraction efficiency of VPA were optimized. Under optimized microextraction conditions, VPA was extracted with 10 μL 1-octanol from 0.5 mL rat plasma previously diluted with 4.5 mL acidified and salinated water (pH 2) using 1-octanoic acid as internal standard. The limit of detection was 17 ng mL−1 with linear response over the concentration range of 50–10,000 ng mL−1 with correlation coefficient higher than 0.998. The developed method was successfully applied to determination of pharmacokinetic parameters such as t max (peak time in concentration–time profile), C max (peak concentration in concentration–time profile), t 1/2 (elimination half-life), AUC0–t (area under the curve for concentration versus time), clearance, and apparent distribution volume in rats following oral administration of VPA.

  相似文献   

2.
L. Ma  J. Dong  X. J. Chen  G. J. Wang 《Chromatographia》2007,65(11-12):737-741
The aim of this research was to develop a sensitive liquid chromatographic–electrospray ionization–mass spectrometric (LC–MS) method for direct measurement of the concentration of Atorvastatin in human plasma. Plasma samples (1 mL) were extracted with 3 mL ethyl acetate, and by a simple reversed-phase chromatography. Pitavastatin was used as internal standard (IS). The LOQ was 0.25 ng mL?1 (RSD 4.24%). The assay was linear from 0.25–20 ng mL?1. And the correlation coefficient for the calibration regression line was 0.9996 or better. Intra-day and inter-day accuracy were better than 15%. The method has been successfully used for a pharmacokinetic study with human subjects. A two-period crossover designed bioequivalence research was also progressed in healthy Chinese volunteers. Among the pharmacokinetic data obtained, T max was 1.36 ± 0.68 h for reference formulation and 0.81 ± 0.54 h for test formulation. C max was 8.54 ± 5.06 ng mL?1 for reference formulation and 9.54 ± 3.68 ng mL?1 for test formulation. t 1/2 was 8.50 ± 2.74 h for reference formulation and 9.24 ± 3.17 h for test formulation. AUC 0?48h was 54.77 ± 21.82 h ng mL?1 for reference formulation and 55.66 ± 20.91 h ng mL?1 for test formulation. The method was successfully applied to the study of pharmacokinetics of Atorvastatin in healthy Chinese volunteers.  相似文献   

3.
A simple, rapid and sensitive liquid chromatography–mass spectrometry (LC–MS) method was developed for the quantification of salidroside in rat plasma and the study of its pharmacokinetics after oral administration of 15 g kg?1 Rhodiola crenulata extract to Wistar rats. A 200 μL plasma sample was extracted by acetonitrile and performed on Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with the mobile phase of acetonitrile–water (11:89) within a run time of 8 min. The analyte was monitored with electrospray ionization (ESI) by selected ion monitoring (SIM) mode. The target ions were m/z 299.20 for salidroside and m/z 150.00 for internal standard (IS) paracetamol. A good linear relationship was obtained over the range of 100–20,000 ng mL?1 and the lower limit of quantification was 100 ng mL?1. The validated method was successfully applied for the pharmacokinetic study of salidroside in rat. After oral administration of Rhodiola crenulata extract, the main pharmacokinetic parameters T max, T 1/2, C max, AUC 0?t and AUC 0?∞ were 0.56 ± 0.21 h, 7.91 ± 4.42 h, 3,386 ± 2,138 ng mL?1, 16,146 ± 6,558 ng h mL?1 and 18,599 ± 6,529 ng h mL?1, respectively.  相似文献   

4.
A sensitive liquid chromatographic–electrospray ionization–mass spectrometric (LC–MS) method has been developed for direct measurement of the concentration of tiopronin in human plasma. Hydrochloric acid solution was used to stabilize the tiopronin and prevent formation of a dimer, or reaction with endogenous thiols. The method involved liquid–liquid extraction of tiopronin from plasma samples with ethyl acetate, simple reversed-phase chromatography, and mass spectrometric detection with nanogram detection limits. Acetaminophen was used as internal standard (IS). The limit of quantification was 5 ng mL?1 (RSD 4.3%). The method was validated within the linear range 5–500 ng mL?1. The correlation coefficient for the calibration regression line was 0.9997 or better. Intra-day and inter-day accuracy were better than 15%. The method has been successfully used for a pharmacokinetic study with human subjects. Among the pharmacokinetic data obtained, t 1/2 was 2.37 ± 0.63 h and T max was 4 h.  相似文献   

5.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of Meserine ((?)-meptazinol phenylcarbamate), a novel potent inhibitor of acetylcholinesterase (AChE), was developed, validated, and applied to a pharmacokinetic study in mice brain. The lower limit of quantification (LLOQ) was 1 ng mL?1 and the linear range was 1–1,000 ng mL?1. The analyte was eluted on a Zorbax SB-Aq column (2.1?×?100 mm, 3.5 μm) with the mobile phase composed of methanol and water (70:30, v/v, aqueous phase contained 10 mM ammonium formate and 0.3 % formic acid) using isocratic elution, and monitored by positive electrospray ionization in multiple reaction monitoring (MRM) mode. The flow rate was 0.25 mL min?1. The injection volume was 5 μL and total run time was 4 min. The relative standard deviation (RSD) of intraday and interday variation was 2.49–7.81 and 3.01–7.67 %, respectively. All analytes were stable after 4 h at room temperature and 6 h in autosampler. The extraction recoveries of Meserine in brain homogenate were over 90 %. The main brain pharmacokinetic parameters obtained after intranasal administration were T max?=?0.05 h, C max?=?462.0?±?39.7 ng g?1, T 1/2?=?0.4 h, and AUC(0-∞)?=?283.1?±?9.1 ng h g?1. Moreover, Meserine was distributed rapidly and widely into brain, heart, liver, spleen, lung, and kidney tissue. The method is validated and could be applied to the pharmacokinetic and tissue distribution study of Meserine in mice.  相似文献   

6.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry quantitative detection method, using amantadine as internal standard, was developed for the simultaneous analysis of paracetamol, pseudoephedrine and chlorpheniramine concentrations. Analytes were extracted from plasma samples by liquid–liquid extraction with n-hexane–dichloromethane–2-propanol (2:1:0.1, v/v), separated on a C18 reversed-phase column with 0.1% formic acid–methanol (40:60, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves for plasma were linear over the concentration range 10–10,000 ng mL?1 of paracetamol, 2–2,000 ng mL?1 of pseudoephedrine and 0.2–200 ng mL?1 of chlorpheniramine. The method has a lower limit of quantitation of 10 ng mL?1 for paracetamol, 2.0 ng mL?1 for pseudoephedrine and 0.2 ng mL?1 for chlorpheniramine. Recoveries, precision and accuracy results indicate that the method was reliable within the analytical range, and the use of the internal standard was very effective for reproducibility by LC-MS-MS. This method is feasible for the evaluation of pharmacokinetic profiles of a novel multicomponent sustained release formulation containing 325 mg of paracetamol, 30 mg of pseudoephedrine hydrochloride and 2 mg of chlorpheniramine maleate. It is the first time the pharmacokinetic evaluation of a novel sustained-action formulation containing paracetamol, pseudoephedrine and chlorpheniramine has been elucidated in vivo using LC-MS-MS.  相似文献   

7.
A sensitive fluorescence liquid chromatographic analytical method was developed for the simultaneous determination of carnosine enantiomers in rat plasma. The method was applied to pharmacokinetic studies. Chiral separation of carnosine enantiomers was achieved by pre-column derivatization with o-phthaldialdehyde and the thiol N-acety-l-cysteine as derivating reagents. They were separated on an ODS column and detected by fluorescence detection (λex = 350 nm, λem = 450 nm). γ-Aminobutyric acid was used as internal standard. The method was linear up to 6,000 ng mL?1 for l-carnosine, 4,000 ng mL?1 for d-carnosine. Low limit of quantitation (LLOQ) was 40 ng mL?1 for each isomer. The relative standard deviations obtained for intra- and inter-day precision were lower than 12% and the recoveries were higher than 75% for both enantiomers. The method was applied to a stereoselective study on the pharmacokinetics of carnosine after oral administration with a single dose (carnosine, 75 mg kg?1 for each isomer) to a rat. The initial data indicated that l-carnosine had a larger value of the highest plasma concentration than d-carnosine (C max 5,344 vs. 1,914 ng mL?1), and that of l-carnosine had a lower value of AUC(0?∞) and t 1/2(h) (AUC(0?∞) 5,306 vs. 6,321 ng h mL?1, t 1/2 1.43 vs. 3.37 h). Our results indicated that the pharmacokinetic of l-carnosine and d-carnosine revealed enantioselective properties significantly.  相似文献   

8.
A simple and sensitive liquid chromatographic assay with fluorescence detection assay was developed for the determination of zearalenone levels in rat serum. The assay utilized a single liquid–liquid extraction with t-butyl methyl ether and isocratic elution using a mobile phase consisting of acetonitrile and 0.1% triethylamine in distilled water (pH = 6) (50:50, v/v). Linearity was observed over a concentration range from 10 to 1,000 ng mL?1 (r = 0.9995), with the limit of quantification at 10 ng mL?1 with 100 μL of rat serum. The validated assay was applied to a pharmacokinetic study in rats.  相似文献   

9.
In order to provide useful information for rational drug design, the ocular pharmacokinetics of l-carnosine (CAR) and its acetylized prodrug N-acetyl-l-carnosine (NAC) were investigated. The in vivo microdialysis sampling coupled with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) was developed for continuously simultaneous monitoring of CAR and NAC in rabbit aqueous humor. The measured in vitro recoveries of the probe were 61.3% for CAR and 65.8% for NAC, while in vivo recoveries decreased to 43.1% for CAR and 43.0% for NAC, respectively. The method was sensitive with LLOQ 20.5 ng mL?1 for CAR and 20.4 ng mL?1 for NAC. The initial data indicated that the value of C max and AUC(0?C??) of NAC were higher than these of CAR (C max 2305 vs. 1,802 ng mL?1), (AUC(0?C??) 1,337 vs. 1,891 ng h mL?1), which indicated that the NAC exhibited better ocular bioavailability and duration. The method was rapid, specific and sensitive for continuously monitoring of aqueous humor and it was successfully applied to pharmacokinetic studies of CAR and NAC.  相似文献   

10.
A valid and sensitive LC-MS–MS method is adopted for pharmacokinetics study of berberine and palmatine in rabbit plasma. After mixing with internal standard tetrahydroberberine, plasma samples were pretreated with 1.5 mL acetonitrile. Chromatographic separation was on a C18 column using a mixture of water (containing 10 mmol L?1 ammonium acetate, pH 3.5) and acetonitrile (50∶50, v/v) as mobile phase. The detection was performed by selected ion monitoring mode via electrospray ionization source operating in the positive ionization mode. The method was linear over the concentration range of 2.0–200.0 ng mL?1 for berberine and 1.0–100.0 ng mL?1 for palmatine. The lowest limits of quantitation (LLOQ) were 2.0 ng mL?1 for berberine and 1.0 ng mL?1 for palmatine. The intra- and inter-day precision values were less than 14.3% and the deviations were within ±11.0%. The fully validated LC-MS–MS method has been successfully applied to a pharmacokinetic study of berberine, palmatine in rabbit plasma after oral administration of Coptidis and coptidis–gardeniae couple extract. The results indicated that the plasma profiles of the two compounds in rabbit confirmed to one-compartment open model and the combinational utilization with Gardeniae could increase the bioavailability of berberine and palmatine, the two major active components of Coptidis.  相似文献   

11.
A sensitive, precise and simple LC method for the simultaneous quantification of aliskiren, valsartan and sitagliptin in rat plasma has been developed and validated. The chromatographic separation was achieved on a C18 column (250 mm × 4.6 mm, 5 μm) maintained at room temperature, using isocratic elution with acetonitrile/20 mM ammonium acetate buffer (35:65, v/v), pH adjusted to 4.85 with glacial acetic acid, and detected using a fluorescence detector. Liquid–liquid extraction of the aliskiren, valsartan and sitagliptin from the rat plasma with t-butyl methyl ether resulted in their high recoveries. LC calibration curves based on the extracts from the rat plasma were linear in the range of 25–2,000 ng mL?1 for aliskiren and sitagliptin and 50–4,000 ng mL?1 for valsartan. The limits of quantification were 25 ng mL?1 for aliskiren and sitagliptin and 50 ng mL?1 for valsartan. The precision and accuracy of the method were well within the generally accepted criteria for biomedical analysis. The described method was successfully applied to study the pharmacokinetics of aliskiren, valsartan and sitagliptin following oral administration, individually as well as in combination in Sprague–Dawley rats. The results of the study implied the occurrence of pharmacokinetic interaction upon the co-administration of these three drugs.  相似文献   

12.
A new method, termed dispersive liquid–liquid microextraction (DLLME), was developed for the extraction and pre-concentration of estrone (E1) and 17β-estradiol (E2) in water samples. The samples were extracted by 0.50 mL methanol (disperser solvent) containing 25.0 μL tetrachloroethane (extraction solvent). Important factors such as the volume and type of extraction and disperser solvent, extraction time and salt effect were studied. Under optimum conditions, the enrichment factors and the limits of detection were 347 and 0.2 ng mL?1 for E1, and 203 and 0.1 ng mL?1 for E2, respectively. The linear range was 0.5–5,000 ng mL?1. Compared to other methods, DLLME–LC–VWD has advantages for E1 and E2 analysis in water: high enrichment factor, low cost, simplicity, quick and easy operation.  相似文献   

13.
To evaluate the bioequivalence of nateglinide, a rapid and specific liquid chromatographic-electrospray ionization mass spectrometric method was developed and validated to determine nateglinide for human plasma samples. The analyte was detected using electrospray positive ionization mass spectrometry in the selected ion monitoring mode. Tinidazole was used as the internal standard. A good linear relationship obtained in the concentration ranged from 0.05 to 16 μg mL?1 (r 2 = 0.9993). Lower limit of quantification was 0.05 μg mL?1 using 100 μL of plasma sample. Intra- and inter-day relative standard deviations were 2.1–7.5 and 4.7–8.9%, respectively. Among the pharmacokinetic data obtained, T max was 2.09 ± 1.06 h for reference formulation and 2.40 ± 0.97 h for test formulation. C max was 4.17 ± 1.31 μg mL?1 for reference formulation and 4.37 ± 1.53 μg mL?1 for test formulation. The half-life (t ½) was 1.93 ± 0.44 h for reference formulation and 1.92 ± 0.29 h for test formulation. AUC0–10h was 13.67 ± 4.36 μg h mL?1 for reference formulation and 13.21 ± 4.09 μg h mL?1 for test formulation. This method was successfully applied to the pharmacokinetic study in human plasma samples.  相似文献   

14.
A sensitive, simple, and accurate method for determination and pharmacokinetic study of ferulic acid and isoferulic acid in rat plasma was developed using a reversed-phase column liquid chromatographic (RP-LC) method with UV detection. Sample preparations were carried out by protein precipitation with the addition of methanol, followed by evaporation to dryness. The resultant residue was then reconstituted in mobile phase and injected into a Kromasil C18 column (250 × 4.6 mm i.d. with 5 μm particle size). The mobile phase was methanol-1% formic acid (33:67, v/v). The calibration plots were linear over the range 5.780–5780 ng·mL?1 for ferulic acid and 1.740–348.0 ng·mL?1 for isoferulic acid. Mean recoveries were 85.1% and 91.1%, respectively. The relative standard deviations (RSDs) of within-day and between-day precision were not above 15% for both of the analytes. The limits of quantification were 5.780 ng·mL?1 for ferulic acid and 1.740 ng·mL?1 for isoferulic acid. This RP-LC method was used successfully in pharmacokinetic studies of ferulic acid and isoferulic acid in rat plasma after intravenous injection of Guanxinning Lyophilizer.  相似文献   

15.
A rapid and specific high-performance liquid chromatographic method coupled with electrospray ionization mass spectrometric detection has been developed and validated for identification and quantification of wogonin and oroxylin A in rat plasma. Wogonin, oroxylin A, and diazepam (internal standard) were extracted from plasma samples by liquid–liquid extraction with ethyl acetate. Chromatographic separation was achieved on a C18 column with acetonitrile–0.6% aqueous formic acid 35:65 (v/v) as mobile phase at a flow rate of 0.2 mL min?1. Detection was performed with a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. Linearity was good within the concentration range 14.4–360 ng mL?1 for wogonin and 10.8–271 ng mL?1 for oroxylin A; the correlation coefficients (r 2) were 0.9999. The intra-day and inter-day precision, as RSD, was below 12.4%, and accuracy ranged from 81.1 to 111.9%. The lower limit of quantification was 14.4 ng mL?1 for wogonin and 10.8 ng mL?1 for oroxylin A. This method was successfully used in the first pharmacokinetic study of wogonin and oroxylin A in rat plasma after oral administration of the active fraction from Xiao-xu-ming decoction.  相似文献   

16.
A sensitive, rapid and reproducible LC–MS/MS method for the determination of olmesartan (OLM), amlodipine (ALM) and hydrochlorothiazide (HCZ) in rat plasma and urine has been developed and validated. Irbesartan (IRB) was used as an internal standard. The analytes were separated on a Waters XTerra-C18 column using gradient elution with acetonitrile and 10 mM ammonium acetate buffer (pH 3.5, adjusted with acetic acid) at a flow rate of 1.0 mL min?1. The three analytes were ionized by positive ion electrospray using multiple-reaction monitoring (MRM) mode to monitor precursor?→?product ion transitions m/z 447.31?→?234.97 for OLM, 408.87?→?238.18 for AML and 290.1?→?204.85 for HCZ. The specificity, matrix effect, recovery, sensitivity, linearity, accuracy, precision, and stabilities were all validated over the concentration range 0.4–100 ng mL?1 for AML, 0.2–100 ng mL?1 for OLM, 0.1–100 ng mL?1 for HCZ. The mean concentrations (Cmax) are 10.32, 587, and 3.4 for OLM, ALM, and HCZ, respectively, by the oral administration of 15 mg kg?1 of each analyte.  相似文献   

17.
A highly sensitive liquid chromatographic-atmospheric pressure chemical ionization-tandem mass spectrometric method is developed to quantitate phenacetin and its metabolite paracetamol in rabbit plasma. The analytes and internal standard oxazepam are extracted from plasma by liquid–liquid extraction using ethyl acetate, and separated on a Zorbax SB-C18 column (2.1 mm × 150 mm, 5 μm) using acetonitrile–0.1% formic acid in water (40:60 v/v) at a flow of 0.4 mL min?1. Detection is carried out by multiple reaction monitoring on a ion-trap LC-MS-MS system with an atmospheric pressure chemical ionization interface. The assay is linear over the range 4–1,600 ng mL?1 for phenacetin and 3–2,000 ng mL?1 for paracetamol, with a lower limit of quantitation of 4 ng mL?1 for phenacetin and 3 ng mL?1 for paracetamol. Intra- and inter-day precision are less than 7.1% and the accuracy are in the range 97.3–103.5%. The validated method is successfully used to analyze the drug in samples of rabbit plasma for pharmacokinetic study.  相似文献   

18.
A rapid and sensitive LC–MS–MS method was developed and validated for the determination of asiaticoside in rat plasma. Asiaticoside was extracted by protein precipitation with acetonitrile, and separated on a C18 column. The total analytical time was relatively short (4 min), and the limit of quantification was 38 ng mL?1 using 100 μL of rat plasma. Asiaticoside and the internal standard (felodipine) were monitored in the multi-reaction-monitoring mode as follows: m/z 957.4 → 469.3 and m/z 382.2 → 145.1, respectively. Calibration was linear over a concentration range from 38 to 7,600 ng mL?1, and the correlation coefficient was greater than 0.998. The recoveries of asiaticoside from plasma were better than 85%, and RSDs of inter-day and intra-day assays were below 10.1%. The method is sensitive and specific, and suitable for pharmacokinetic studies of asiaticoside in rats.  相似文献   

19.
A rapid LC method with UV detection was developed for the quantification of carboxylic acid metabolite of clopidogrel in human plasma. Following a simple protein precipitation using a mixture of methanolic solution of ZnSO4, the analyte and commercially available internal standard were separated using a mobile phase of water–acetonitril (85:15, v/v) adjusted to pH 3.5 on a Chromolith C18 column at a flow rate of 2.5 mL min?1 with a total retention time of 4 min. Linearity was verified over the range of 20–3,000 ng mL?1 where the LOQ was 20 ng mL?1. This method was applied in a pharmacokinetic study.  相似文献   

20.
A simple, sensitive, and precise high performance liquid chromatographic method for the analysis of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride, with ultraviolet detection at 210 nm, has been developed, validated, and used for the determination of compounds in commercial pharmaceutical products. The compounds were well separated on a Hypersil BDS C18 reversed-phase column by use of a mobile phase consisting of 0.05 M, 4.70 pH, potassium dihydrogen phosphate buffer - acetonitrile (720:280 v/v) at a flow rate of 1.0 mL min?1. The linearity ranges were 400–4,000 ng mL?1 for pantoprazole, 200–2,000 ng mL?1 for rabeprazole, 400–4,000 ng mL?1 for esomeprazole, 300–3,000 ng mL?1 for domperidone and 500–5,000 ng mL?1 for itopride. Limits of detection (LOD) obtained were: pantoprazole 147.51 ng mL?1, rabeprazole 65.65 ng mL?1, esomeprazole 131.27 ng mL?1, domperidone 98.33 ng mL?1 and itopride 162.35 ng mL?1. The study showed that reversed-phase liquid chromatography is sensitive and selective for the determination of pantoprazole, rabeprazole, esomeprazole, domperidone and itopride using single mobile phase.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号