 共查询到18条相似文献,搜索用时 187 毫秒
1.
Arai K  Mori M  Hironaga T  Itabashi H  Tanaka K 《色谱》2012,30(4):404-408
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.  相似文献   

2.
Ion-exclusion/anion-exchange chromatography(IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH——form with basic eluent has been developed.The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase.This system is useful for simultaneous separation and determination of ammonium ion(NH+4),nitrite ion(NO-2),and nitrate ion(NO-3) in water samples.The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column.In this study,several separation columns,which consisted of different particle sizes,different functional groups and different anion-exchange capacities,were compared.As the results,the separation column with the smaller anion-exchange capacity(TSKgel Super IC-Anion) showed well-resolved separation of cations and anions.In the optimization of the basic eluent,lithium hydroxide(LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L,considering the resolution of analyte ions and the whole retention times.In the optimal conditions,the relative standard deviations of the peak areas and the retention times of NH+4,NO-2,and NO-3 ranged 1.28%-3.57% and 0.54%-1.55%,respectively.The limits of detection at signal-to-noise of 3 were 4.10 μmol/L for NH+4,1.87 μmol/L for NO-2 and 2.83 μmol/L for NO-3.  相似文献   

3.
A method for rapid and simultaneous determination of multiple pyrrolidinium ionic liquid cations by ion chromatography with direct conductivity detection was developed.Chromatographic separations were performed on a cation exchange column using ethylenediamine-acetonitrile as the mobile phase.The effects of chromatographic column and the mobile phase,as well as the column temperature on the retention of the cations were investigated.The retention rules of the cations under different chromatographic conditions were formulated.The retention of the cations followed the carbon number rule.The method has been successfully applied to the determination of three ionic liquids synthesized by a chemical laboratory.  相似文献   

4.
Fast analysis of thiocyanate by ion-pair chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e using tetrabutylammonium hydroxide (TBA)-phthalic acid-acetonitrile as eluent. The effects of eluent concentration, eluent pH value, column temperature and flow rate on retention time of thiocyanate were investigated. The optimized chromatographic conditions for the determination of thiocyanate were as follows: 0.25 mmol/L TBA-0.18 mmol/L phthalate-7% acetonitrile (pH 5.5) as eluent, column temperature of 30 ℃, and flow rate of 6.0 mL/min. Retention time of thiocyanate was less than 1 min under the conditions. Common anions (Cl^-, NO3 , SO42 and I^- ) did not interfere with the determination of thiocyanate. Detection limit (S/N = 3) of thiocyanate was 0.96 mg/L. Calibration graph between peak area and the concentration of thiocyanate was linear in the range of 2.0- 100.0 mg/L. Relative standard deviation (RSD) of chromatographic peak area was 1.4% (n = 5). This method has been applied to the determination of thiocyanate in ionic liquids. Recoveries of thiocyanate after spiking were 100.5%.  相似文献   

5.
A unified ion-exclusion chromatography(IEC) system for monitoring anionic and cationic nutrients like NH + 4,NO 2,NO 3,phosphate ion,silicate ion and HCO 3 was developed and applied to several environmental waters.The IEC system consisted of four IEC methodologies,including the IEC with ultraviolet(UV) detection at 210 nm for determining NH + 4 on anion-exchange separation column in OH form connected with anion-exchange UV-conversion column in I form in tandem,the IEC with UV-detection at 210 nm for determining simultaneously NO 2 and NO 3 on cation-exchange separation column in H + form,the IEC with UV-detection at 210 nm for determining HCO 3 on cation-exchange separation column in H + form connected with anion-exchange UV-conversion column in I form in tandem,and the IEC with visible-detection based on molybdenum-blue reaction for determining simultaneously silicate and phosphate ions on cation-exchange separation column in H + form.These IEC systems were combined through three manually-driven 6-port column selection valves to select each separation column to determine selectively the ionic nutrients.Using this sequential water quality monitoring system,the analytical performances such as calibration linearity,reproducibility,detection limit and recovery were also tested under the optimized chromatographic conditions.This novel water quality monitoring system has been applied successfully for the determination of the ionic eutrophication components in sub-urban river waters.  相似文献   

6.
An ion chromatography method has been proposed for the determination of three common inorganic anions(chloride,nitrate and sulfate) in anionic surfactants using a single pump system.The new system consists of an ion exclusion column,a concentrator column,and an anion exchange column connected in series via two 6-ports valves in a Dionex ICS-2000 ion chromatograph.The valves were switched several times for removing surfactants,concentrating and separating the three anions.The chromatographic conditions were optimized.Detection limits(S/N = 3) were in the range of 0.10-0.68μg/L.The relative standard deviations(RSDs) of peak area were less than 4.6%.The recoveries were in the range of 84.1-112.6%.  相似文献   

7.
A new stationary phase for iodide ion analysis has been developed. The cationic polymerepichlorohydrin-dimethylamine(PEPI-DMA) was served as modifier in synthesizing polyelectrolyte sorbents and the macroporous polystyrene-divinylbenzene(PS-DVB) resin was used as support. The positively charged polymer(PEPI-DMA) was electrostatically bonded to a negatively charged particle(PS-DVB sulfonated). The new stationary phase was characterized by scanning electron microscopy(SEM), Fourier transform infrared(FTIR), elemental analysis, chemical adsorption and desorption measurements. The chromatographic evaluation of the new stationary phase was performed using various anions with a conductivity detector. The new stationary phase was also applied to the determination of iodide directly with a DC amperometric detector using a platinum working electrode and an Ag/Ag Cl reference electrode. The chromatographic conditions were optimized and the eluent solution contained 5 mmol/L HNO3 and 15 mmol/L Na NO3 at a flow rate of 1.0 m L/min and column temperature of 30 8C. The applied voltage of the DC amperometric detector was 0.9 V. Under the optimum conditions, the linear range of the method was 0.2–50 mg/L for iodide ion with a correlation coefficient of 0.9990. The detection limit was 0.05 mg/L(calculated at S/N = 3) and the relative standard deviations(RSD, n = 6) were all less than 1% for retention time, peak area and peak height. This method was also utilized for the determination of iodide ions in samples of povidone iodine solution and kelp samples with satisfactory results.  相似文献   

8.
The analysis of seven aliphatic carboxylic acids(formic,acetic,propionic,iso-butyric,n-butyric,iso-valeric and n-valeric acid) in anaerobic digestion process waters for biogas production was examined by ion-exclusion chromatography with dilute acidic eluents(benzoic acid,perfluorobutyric acid(PFBA) and sulfuric acid) and non-suppressed conductivity/ultraviolet(UV) detection.The columns used were a styrene/divinylbenzene-based strongly acidic cation-exchange resin column(TSKgel SCX) and a polymethacrylate-based weakly acidic cation-exchange resin column(TSKgel Super IC-A/C).Good separation was performed on the TSKgel SCX in shorter retention times.For the TSKgel Super IC-A/C,peak shape of the acids was sharp and symmetrical in spite of longer retention times.In addition,the mutual separation of the acids was good except for iso-and n-butyric acids.The better separation and good detection was achieved by using the two columns(TSKgel SCX and TSKgel Super IC-A/C connected in series),lower concentrations of PFBA and sulfuric acid as eluents,non-suppressed conductivity detection and UV detection at 210 nm.This analysis was applied to anaerobic digestion process waters.The chromatograms with conductivity detection were relatively simpler compared with those of UV detection.The use of two columns with different selectivities for the aliphatic carboxylic acids and the two detection modes was effective for the determination and identification of the analytes in anaerobic digestion process waters containing complex matrices.  相似文献   

9.
银杏叶提取物中黄酮类成分的高效液相色谱分析   总被引:39,自引:0,他引:39  
谢大年  郭兆贵 《色谱》1994,12(5):384-385
Quantitative reversed-phase high performance liquid chromatographic method has been developed for theseparation and determination of the flavonoids found in the extracts of the leaves of ginkgo biloba L. (EGb).Procedure includes hydrolysis of the flavonoids and subsequent quantitative chromatographic assay of the ob-tained aglycones on a C_(18) column with methanol-0.4% orthophosphoric acid (55:45) as eluent. The detec-tion was effected at 360nm.  相似文献   

10.
A novel analytical method was developed for determining morpholinium cations lacking ultraviolet absorption groups.This determination was carried out by high performance liquid chromatographyindirect ultraviolet(HPLC-1UV) detection using imidazolium ionic liquid as background absorption reagents,and imidazolium ionic liquid aq.soln.-organic solvent as mobile phase by a reversed-phase C18 column.The background ultraviolet absorption reagents,imidazolium ionic liquids and organic solvents were investigated.The imidazolium ionic liquid in the mobile phase is not only the background ultraviolet absorption reagent for IUV,but also an active component to improve the separation of morpholinium cations.It was found that morpholinium cations could be adequately determined when0.5 mmol/L 1-ethyl-3-methylimidazolium tetrafluoroborate aq.soln./methanol(80:20,v/v) was used as mobile phase with an IUV detection wavelength of 210 nm.In this study,the baseline separation of Nmethyl,ethylmorpholinium cations(MEMo) and N-methyl.propylmorpholinium cations(MPMo) was successfully achieved in 8.5 min.The detection limits(S/N = 3) for MEMo and MPMo were 0.15 and0.29 mg/L,respectively.This simple and practical method has been successfully applied to the determination of two morpholinium ionic liquids synthesized by the chemistry laboratory.  相似文献   

11.
Ding MY  Tanaka K  Hu W  Hasebe K  Haddad PR 《The Analyst》2001,126(5):567-570
A non-suppressed conductivity detection ion chromatographic method using a weakly acidic cation-exchange column (Tosoh TSKgel OApak-A) was developed for the simultaneous separation and determination of common inorganic anions (Cl-, NO3- and SO4(2-)) and cations (Na+, NH4+, K+, Mg2+ and Ca2+). A satisfactory separation of these anions and cations on the weakly acidic cation-exchange column was achieved in 25 min by elution with a mixture of 1.6 mmol L-1 pyridine-2,6-dicarboxylic acid and 8.0 mmol L-1 18-crown-6 at flow rate of 1.0 mL min-1. On this weakly acidic cation-exchange resin, anions were retained by an ion-exclusion mechanism and cations by a cation-exchange mechanism. The linear range of the peak area calibration curves for all analytes were up to two orders of magnitude. The detection limits calculated at S/N = 3 ranged from 0.25 to 1.9 mumol L-1 for anions and cations. The ion-exclusion chromatography-cation-exchange chromatography method developed in this work was successfully applied to the simultaneous determination of major inorganic anions and cations in rainwater, tap water and snow water samples.  相似文献   

12.
Poly(aspartic acid)-silica (PolyCAT A), originally designed for the cation-exchange chromatography of proteins, is proposed for the simultaneous ion chromatographic separation of inorganic anions and cations. This is possible owing to the zwitterion-exchange properties of this stationary phase, which are attributed to the presence of both protonated aminopropyl and dissociated carboxylic groups in poly(aspartic acid) attached to the silica. The retention of alkali metal (Li+, Na+, K+), alkaline earth metal (Mg2+, Ca2+), ammonium and inorganic anions (Cl-, H2PO4-, Br-, NO2-, I-, IO3-, NO3-, ClO4-, SCN-) was tested in aqueous solutions of sulfuric, perchloric, sulfosalicylic, citric, oxalic, maleic and aspartic acids with conductimetric detection. The effect of eluent pH, together with the concentration and characteristics of the eluting ions, were studied. Under optimum conditions (0.3 mmol dm(-3) H2SO4-0.2 mmol dm(-3) Li2SO4 eluent), the simultaneous separation of three anions (Cl-, H2PO4-, NO3-) and four cations (Na+, K+, Mg2+, Ca2+), on a PolyCAT A column (200 x 4.6 mm id, 5 microm film thickness) was achieved in 9 min.  相似文献   

13.
离子色谱法测定饲料中氯化胆碱和三甲胺的含量   总被引:12,自引:0,他引:12  
丁永胜  牟世芬 《色谱》2004,22(2):174-176
建立了离子色谱法测定饲料中氯化胆碱含量及鉴别饲料中氯化胆碱及掺假物三甲胺的方法。选用IonPac CS12阳离子交换色谱柱(250 mm×4 mm i.d.)和8.5 mmol/L H2SO4淋洗液,抑制型电导检测,在16 min内分离测定了包括胆碱和三甲胺在内的8种阳离子。胆碱和三甲胺的最小检出限分别为0.1 mg/L和0.05 mg/L。方法回收率为99.25%~102.5%。该方法具有灵敏度高、选择性强、操作简单等优点。  相似文献   

14.
抑制型离子色谱测定纳米金刚石粉末表面吸附的阴离子   总被引:1,自引:0,他引:1  
杨海军  丁明玉 《分析化学》2002,30(12):1497-1500
采用抑制型离子色谱法,以NaHCO3/Na2CO3作流动相,测定了纳米金刚石粉末表面吸附的F^-、Cl^-、SO4^2-、NO3^-等阴离子的浓度,研究了淋洗液浓度对离子保留的影响以及样品处理中超声洗脱分散时间对测定结果的影响。适宜的流动相为0.84mmol/L NaHCO3 0.9mmol/L Na2CO3;超声洗脱分散时间应在10min以上。在此流动相条件下测定了上述6种阴离子的检出限及其它定量参数。方法应用于纳米金刚石粉末试样的分析,结果良好。  相似文献   

15.
建立离子色谱法同时测定大气降水中F^-,Cl^-,NO2^-,Br-,NO3^-,SO4^2-和PO43^-7种阴离子的分析方法。选用IonPac■AS19型色谱柱(4 mm×250 mm),以KOH梯度淋洗,用抑制电导检测器进行测定。7种阴离子在各自的质量浓度范围内与色谱峰面积成良好的线性关系,相关系数均不小于0.997,方法检出限为0.002~0.004 mg/L。测定结果的相对标准偏差为0.80%~3.38%(n=6),样品加标回收率为75.0%~98.7%。该方法简便、快速,灵敏度高,适用于大气降水中F^-,Cl^-,NO2^-,Br^-,NO3^-,SO4^2-和PO43^-7种阴离子的同时测定。  相似文献   

16.
建立生活饮用水中F~–,Cl~–,PO_3^(3–),PO_4^(3–),SO_3^(2–),SO_4^(2–)6种阴离子的离子色谱检测法。采用戴安DX–120型离子色谱仪及Ion Pac AS9–HC(250 mm×4.0 mm)阴离子交换柱,以5.0 mmo L/L Na_2CO_3–0.6 mmo L/L NaHCO_3溶液为淋洗液,流量为1.2 mL/min。6种阴离子的质量浓度与其色谱峰面积呈良好的线性关系,相关系数为0.999 3~0.999 8,检出限为0.026 4~0.741 4μg/mL(S/N=3)。水样的加标回收率为91.3%~110.0%,测定结果的相对标准偏差为1.65%~3.07%(n=6)。该方法具有操作简单,选择性、准确性好等优点,能够满足饮用水中F~–,Cl~–,PO_3^(3–),PO_4^(3–),SO_3^(2–),SO_4^(2–)6种阴离子的测定要求。  相似文献   

17.
建立了高氯、高钠油田回注水中痕量无机阴、阳离子和有机酸的离子色谱分析方法。对高钠基质中痕量阳离子的测定,选用IonPac CS12A分析柱、H2SO4溶液梯度淋洗、电导检测器检测;对高氯基质中阴离子及有机酸的测定,选用对OH-具有高选择性的高容量的IonPac AS11-HC柱、KOH梯度淋洗、电导检测器检测。在优化的梯度淋洗条件下,高氯或高钠的存在不影响痕量阴离子或阳离子的测定。该方法具有良好的线性(r=0.9926~0.9990)和精密度(测定组分峰面积的相对标准偏差(n=7)在8.0%以下),回收率  相似文献   

18.
化妆品中阴阳离子的快速测定及其用于化妆品鉴别的研究   总被引:3,自引:0,他引:3  
用离子色谱电导检测器对黑泥类化妆品中的阴、阳离子(Na+,NH+4,K+,Mg 2+ ,Ca 2+ ,Cl-,Br-,NO-2,NO-3和SO 2- 4)进行了测定。阳离子分离条件: 阳离子交换柱ICS C25,均苯四甲酸淋洗液浓度2.0 mmol/L ,流速0.6 mL/min ;阴离子分离条件: 阴离子交换柱Shim pack IC A1,淋洗液为2.5 mmol/L 邻苯二甲酸和2.4 mmol/L 三羟基氨基甲烷,流速1.0 mL/min 。结果表明,上述10种离子在较宽浓度范围内有良好  相似文献   