首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 493 毫秒
1.
The fluorescence quenching of quantum dots by hemoglobin has been demonstrated to depend on surface functionalization, and this property has been utilized to construct a novel fluorescent method for rapid, sensitive, and selective detection of trace hemoglobin in urine at microgram level. This method shows low interference and high selectivity for hemoglobin with a limit of detection of 4.3 μg L?1 in water and 66.1 μg L?1 in urine, which are lower than those of currently used methods in labs and clinics. Spike and recovery tests in raw, acidified, and alkalized urine samples exhibit good recovery rates for the spiked concentrations close to the limit of detection.
Figure
Fluorescence spectra and photographs of MPA-QD solution before and after the addition of Hb taken under 365-nm irradiation.  相似文献   

2.
A novel rapid (20 min) fluorescent lateral flow test for chloramphenicol (CAP) detection in milk was developed. The chosen format is a binding-inhibition assay. Water-soluble quantum dots with an emission peak at 625 nm were applied as a label. Milk samples were diluted by 20 % with phosphate buffer to eliminate the matrix effect. The result of the assay could be seen by eye under UV light excitation or registered by a portable power-dependent photometer. The limit of CAP detection by the second approach is 0.2 ng/mL, and the limit of quantitation is 0.3 ng/mL.
Figure
Principle of proposed immunoassay of chloramphenicol using quantum dots  相似文献   

3.
Water-soluble cadmium telluride quantum dots (CdTe QDs) capped with glutathione (GSH) display chemiluminescence (CL) emission on reaction with hydrogen peroxide (H2O2) in strongly alkaline medium. It is found that the CL is strongly enhanced on addition of formaldehyde in aqueous solution. A flow injection system was developed, and it is shown that there is good linearity between CL intensity and the concentration of formaldehyde in the 0.06–3.0 μg L?1 range. The limit of detection is as low as 10 ng L?1. The method was successfully applied to the determination of formaldehyde in indoor air after adsorption into an aqueous phase. The recoveries for the real samples range from 97 % to 102.5 %, and the relative standard deviation is <3.8 % for intra- and inter-assay precision.
Figure
Formaldehyde enhances the CL resulting from CdTe quantum dots and H2O2, and this effect is exploited in a simple and sensitive FIA method for the determination of formaldehyde.  相似文献   

4.
We report on a novel electrochemiluminescent (ECL) immunoassay for the ultrasensitive determination of morphine by making use of a gold electrode which was modified with a nanocomposite film containing self-assembled polyamidoamine (PAMAM) CdS quantum dots and electrodeposited gold nanoparticles (Au-NPs). The highly uniform and well-dispersed quantum dots were capped with PAMAM dendrimers. Due to the synergistic effect of the modified quantum dots and the electrodeposited Au-NPs, the ECL response is dramatically enhanced. Under optimal experimental conditions, the immunoreaction between morphine and anti-morphine antibody resulted in a decrease of the ECL signal because of steric hindrance. The calibration plot is linear in the morphine concentration range from 0.2 to 180 ng?mL?1, with a detection limit as low as 67 pg?mL?1. The sensor was successfully applied to the determination of morphine in blood plasma. This kind of assay is expected to pave new avenues in label-free drug assays.
Figure
?  相似文献   

5.
We have synthesized silver nanoparticles (AgNPs) decorated with α-cyclodextrin (CD) by using the traditional silver mirror reaction in the presence of CD. The CD-AgNPs were used as substrate in surface-enhanced Raman spectroscopy (SERS) for determining melamine. The intensity of the Raman band of melamine at 704 cm?1 was used to determine melamine in milk and milk powder. The use of CD-AgNPs as the SERS substrate rather than classical silver nanoparticles makes the method more sensitive in giving an enhancement by a factor of up to?~?106 in scattering efficiency. The effects of the volume of solutions (of CD-AgNPs, NaCl, NaOH, melamine) and of mixing time were optimized. The standard addition method was employed for quantitative analysis. The correlation coefficient of the calibration plot is 0.9995, and the limit of detection is 3.0 μg L?1. The method was successfully applied to the determination of melamine in milk and milk powder, with relative standard deviations of <10 % and recoveries between 89 and 104 %.
Figure
Novel silver nanoparticles decorated with α-cyclodextrin (CD-AgNPs) were prepared. The melamine in milk and milk powder was determined using SERS and CD-AgNPs. The limit of detection is 3.0 μg L?1, and recoveries between 89 and 104 %  相似文献   

6.
We report on a competitive immunoassay for the determination of aflatoxin B1 using fluorescence resonance energy transfer (FRET) from anti-aflatoxin B1 antibody (immobilized on the shell of CdTe quantum dots) to Rhodamine 123 (Rho 123-labeled aflatoxin B1 bound to albumin). The highly specific immunoreaction between the antibody against aflatoxin B1 on the QDs and the labeled-aflatoxin B1 brings the Rho 123 fluorophore (acting as the acceptor) and the QDs (acting as the donor) in close spatial proximity and causes FRET to occur upon photoexcitation of the QDs. In the absence of unlabeled aflatoxin B1, the antigen-antibody complex is stable, and strong emission resulting from the FRET from QDs to labeled aflatoxin B1 is observed. In the presence of aflatoxin B1, it will compete with the labeled aflatoxin B1-albumin complex for binding to the antibody-QDs conjugate so that FRET will be increasingly suppressed. The reduction in the fluorescence intensity of the acceptor correlates well with the concentration of aflatoxin B1. The feasibility of the method was established by the detection of aflatoxin B1 in spiked human serum. There is a linear relationship between the increased fluorescence intensity of Rho 123 with increasing concentration of aflatoxin B1 in spike human serum, over the range of 0.1–0.6 μmol·mL?1. The limit of detection is 2?×?10?11 M. This homogeneous competitive detection scheme is simple, rapid and efficient, and does not require excessive washing and separation steps.
Figure
A nanobiosensor has been fabricated based on a competitive immunoassay for the determination of aflatoxin B1 using fluorescence resonance energy transfer (FRET). In the presence of aflatoxin B1, it will compete with the labeled aflatoxin B1-albumin complex for binding to the antibody-QDs conjugate so that FRET will be increasingly suppressed.  相似文献   

7.
The fluorescent microsphere has been increasingly used as detecting label in immunoassay because of its stable configuration, high fluorescence intensity, and photostability. In this paper, we developed a novel lateral flow fluorescent microsphere immunoassay (FMIA) for the determination of sulfamethazine (SMZ) in milk in a quantitative manner with high sensitivity, selectivity, and rapidity. A monoclonal antibody to SMZ was covalently conjugated with the carboxylate-modified fluorescent microsphere, which is polystyrene with a diameter of 200 nm. Quantitative detection of SMZ in milk was accomplished by recording the fluorescence intensity of microspheres captured on the test line after the milk samples were diluted five times. Under optimal conditions, the FMIA displays a rapid response for SMZ with a limit of detection of as low as 0.025 ng mL?1 in buffer and 0.11 μg L?1 in milk samples. The FMIA was then successfully applied on spiked milk samples and the recoveries ranged from 101.1 to 113.6 % in the inter-batch assay with coefficient of variations of 6.0 to 14.3 %. We demonstrate here that the fluorescent microsphere-based lateral flow immunoassay (LFIA) is capable of rapid, sensitive, and quantitative detection of SMZ in milk.
Figure
Schematic illustration of the strategy for sulfamethazine detection using a lateral flow fluorescent microsphere immunoassay  相似文献   

8.
A simple, fast, and sensitive method for determination of 17 β-estradiol (E2) in goat milk samples has been developed by combining selective molecularly imprinted matrix solid-phase dispersion (MIP–MSPD) and liquid chromatography with diode-array detection (DAD). The molecularly imprinted polymer was synthesized by use of 17β-estradiol as template molecule, methacrylic acid as functional monomer, ethylene glycol dimethacrylate as crosslinker monomer, azobisisobutyronitrile as initiator, and acetonitrile as porogen, and was used as selective solid support for matrix solid-phase dispersion. The selected dispersant had high affinity for E2 in the goat milk matrix and the extract obtained was sufficiently clean for direct injection for HPLC analysis without any interferences from the matrix. The proposed MIP–MSPD method was validated for linearity, precision, accuracy, decision limit (CCα) and detection capability (CCβ), in accordance with European Commission Decision 2002/657/EC criteria. Linearity ranged from 0.3–10 μg g?1 (correlation coefficient r 2?>?0.999). Mean recovery of E2 from goat milk samples at different spiked levels was between 89.5 and 92.2%, with RSD values within 1.3–2%. CCα and CCβ values were 0.36 and 0.39 μg g?1, respectively. The developed MIP–MSPD method was successfully applied to direct determination of E2 in goat milk samples.
Figure
Determination of 17β-Estradiol by using a MIP-MSPD method in goat milk sample  相似文献   

9.
We have developed a 3-phase method for dispersive liquid-liquid microextraction of ß-lactam antibiotics in milk. Chloroform and acetonitrile serve as the solvents for extraction and disperssion, respectively, where Aliquat 336 is the carrier. An experimental design based on Plackett-Burman and Central composite designs were applied for the screening and optimization of significant parameters in the extraction method. The experimental conditions for extraction were optimized, and the subsequent HPLC assay gave relative standard deviations and detection limits in the range of 4.3–8.5 % and 50–500 μg L-1, respectively. Preconcentration factors are in the range of 80–125.
Figure
We have developed a 3-phase method for dispersive liquid-liquid microextraction of ß-lactam antibiotics in milk. Chloroform and acetonitrile serve as the solvents for extraction and disperssion, respectively, where Aliquat 336 is the carrier. An experimental design based on Plackett-Burman and Central composite designs were applied for the screening and optimization of significant parameters in the extraction method.  相似文献   

10.
We have developed a method for the determination of microcystin-leucine-arginine (MC-LR) in water samples that is based on the quenching of the fluorescence of bioconjugates between CdSe/CdS quantum dots (QDs) and the respective antibody after binding of MC-LR. The core-shell CdSe/CdS QDs were modified with 2-mercaptoacetic acid to improve water solubility while their high quantum yields were preserved. Monoclonal MC-LR antibody was then covalently bioconjugated to the QDs. It was found that the fluorescence intensity of the bioconjugates was quenched in the presence of MC-LR. A linear relationship exists between the extent of quenching and the concentration of MC-LR. Parameters affecting the quenching were investigated and optimized. The limit of detection is 6.9?×?10?11 mol L?1 (3σ). The method was successfully applied to the determination of MC-LR in water samples.
Figure
Bioconjugates of CdSe/CdS quantum dots and anti-microcystin-leucine-arginine (MC-LR) antibody were prepared through step A to C. Their fluorescence intensity was quenched linearly with addition of MC-LR at different concentrations (step D). A method for determination of MC-LR was thus established and it was simple, sensitive and specific with low-cost instrumentation  相似文献   

11.
Mixed cationic and anionic surfactants were adsorbed on cadmium sulfide quantum dots (CdS QDs) capped with mercaptoacetic acid. The CdS QDs can be extracted into acetonitrile with 98 % efficiency in a single step. Phase separation only occurs at a molar ratio of 1:1.5 between cationic and anionic surfactants. The surfactant-adsorbed QDs in acetonitrile solution display stronger and more stable photoluminescence than in water solution. The method was applied for determination of silver(I) ion based on its luminescence enhancement of the QDs. Under the optimum conditions, the relative fluorescence intensity is linearly proportional to the concentration of silver(I) ion in the range between 50 pmol L?1and 4 μmol L?1, with a 20 pmol L?1 detection limit. The relative standard deviation was 1.93 % for 9 replicate measurements of a 0.2 μmol L?1 solution of Ag(I).
Figure
?  相似文献   

12.
We report on a 4-min microwave pyrolytic method for the preparation of fluorescent and water-soluble silicon-hybrid carbon dots (C-dots) with high fluorescent quantum yield. The material is prepared by preheating aminopropyltriethoxysilane and ethylene diamine tetraacetic acid for 1 min, then adding a mixture of poly(ethylene glycol) and glycerin to the solution and heating for another 3 min. It is found that the hybrid carbon dots strongly enhance the chemiluminescence (CL) of the luminol/N-bromosuccinimide system. A study on the enhancement mechanism via CL, fluorescence and electron paramagnetic resonance spectroscopy showed that the effect most probably is due to electrostatic interaction between the C-dots and the luminol anion which facilitates electron transfer from luminol anion to the N-bromosuccinimide oxidant. CL intensity is linearly related to the concentration of the C-dots in the range between 1.25 and 20 μg mL?1. The detection limit is 0.6 μg mL?1 (at an S/N of 3).
Figure
New chemiluminescent enhancement property of the fluorescent silican-hybrid carbon dots in luminol-N-bromosuccinimide system has been explored.  相似文献   

13.
We report on a fast, simple and accurate method for the determination of proline in urine samples by employing a nanostructured film of conducting polypyrrole for electrochemically controlled solid-phase microextraction, and ion mobility spectrometry (IMS) for detection. This method has the advantages of simple sample preparation and a sensitivity of IMS to proline that is higher than that for other amino acids. The calibration curve is linear in the range of 0.5–60 μg L?1 (4–521 nmol L?1), and the detection limit is 0.2 μg L?1. The electrochemical potentials for uptake and release were optimized. The method was successfully applied to the clean-up and quantitation of trace amounts of proline in urine samples.
Figure
Proline determination by electrochemically controlled solid phase microextraction coupled to ion mobility spectrometry  相似文献   

14.
A new electrochemical magnetoimmunosensor (EMIS) has been developed for the screening of residues of sulfonamide antimicrobials in honey samples. The immunosensor is able to detect up to ten different sulfonamide congeners at levels below the action points established in some European countries (25 μg kg?1) after a hydrolysis step in which the sulfonamides are released from the corresponding conjugates formed in samples of this type. In spite of the complexity of the sample after the hydrolysis procedure, the EMIS could perform quantitative measurements, directly in these samples, without any additional sample cleanup or extraction step. For example, sulfapyridine, used as a reference, can be detected in hydrolyzed honey with a limit of detection (IC90) of 0.1?±?0.03 μg kg?1. Considering that the use of antibiotics for bee treatment is prohibited in the European Union, the immunosensor presented here could be an excellent screening tool. Moreover, several samples can be processed in parallel, which facilitates the analysis, reducing the necessity to use more costly confirmatory methods for just screening. As a proof of concept, a set of blind honey samples (spiked and incurred) were analyzed and the results were compared with those obtained by high-performance liquid chromatography–tandem mass spectrometry, demonstrating the potential of the EMIS as a screening tool.
Figure
?  相似文献   

15.
A new assay was developed for the determination of five quinolone antibiotic residues in foods, loxacin, enrofloxacin, ciprofloxacin, lomefloxacin, and norfloxacin, by micellar electrokinetic capillary chromatography with indirect laser-induced fluorescence, in which cadmium telluride quantum dots were used as a fluorescent background substance. Some factors that affected the peak height and the resolution were examined. The optimized running buffer was composed of 20 mM SDS, 7.2 mg/L quantum dots, and 10 mM borate at pH 8.8. The separation voltage was 20 kV. Under these conditions, five quinolone antibiotic residues were separated successfully within 8 min. The detection limits ranged from 0.003 to 0.008 mg/kg; the linear dynamic ranges were all 0.01?~?10 mg/kg; and the average recoveries of the spiked samples were 81.4?~?94.6 %. The assay can meet the requirement of maximum residue limits to these five quinolone antibiotics in the regulations of the European Union and Japan and has been applied for determining their residues in animal-derived food.
Figure
Detection process of indirect laser induced fluorescence for quinolone residues  相似文献   

16.
A fully automated method consisting of microextraction by packed sorbent (MEPS) coupled directly to programmed temperature vaporizer–gas chromatography–mass spectrometry (PTV–GC–MS) has been developed to determine the 12 chlorobenzene congeners (chlorobenzene; 1,2-, 1,3-, and 1,4-dichlorobenzene; 1,2,3-, 1,2,4-, and 1,3,5-trichlorobenzene; 1,2,3,4-, 1,2,3,5-, and 1,2,4,5-tetrachlorobenzene; pentachlorobenzene; and hexachlorobenzene) in water samples. The effects of the variables on MEPS extraction, using a C18 sorbent, and the instrumental PTV conditions were studied. The internal standard 1,4-dichlorobenzene d4 was used as a surrogate. The proposed method afforded good reproducibility, with relative standard deviations (RSD %) lower than 12 %. The limits of detection varied between 0.0003 μg L?1 for 1,2,3,4-tetrachlorobenzene and 0.07 μg L?1 for 1,3- and 1,4-dichlorobenzene, while those of quantification varied between 0.001 μg L?1 and 0.2 μg L?1 for the same compounds. Accuracy of the proposed method was confirmed by applying it to the determination of chlorobenzenes in different spiked water samples, including river, reservoir, and effluent wastewater.
Figure
Experimental setup for automated MEPS methodology  相似文献   

17.
We have studied the CdTe quantum dot-induced phototransformation of 2,4-dichlorophenol (2,4-DCP) and its subsequent chemiluminescence (CL) reaction. Quantum dots (QDs) of different size and capped with thioglycolic acid were prepared and characterized by molecular spectroscopy, X-ray diffraction and transmission electron microscopy. In the presence of QDs, 2,4-DCP is photochemically transformed into a long-living light emitting precursor which can react with N-bromosuccinimide to produce CL with peak wavelengths at 475 and 550 nm. The formation of singlet oxygen during the phototransformation process was confirmed by the enhancement effect of deuterium oxide on the CL reaction and the change in the UV spectrum of a chemical trap. The CL intensity is linearly related to the concentration of 2,4-DCP in the range from 0.36 to 36 μmol L?1, and the detection limit (at 3σ) is 0.13 μmol L?1.
Figure
CdTe QDs as an alternative photosensitizer that can be applied to the phototransformation/CL detection of 2, 4-DCP.  相似文献   

18.
A new immunoassay has been developed based on a commercially available anti-caffeine monoclonal antibody and a de novo synthesized tracer, using horseradish peroxidase and UV–visible detection. Caffeine, which is frequently found in surface waters, can be quantified with a relative error lower than 20% for concentrations above 0.025 μg L?1 (limit of quantitation, direct analysis). The limit of detection is 0.001 μg L?1 and can be reduced by solid-phase extraction (SPE). Moreover, with minor adaptations, the assay can be used to quantify caffeine in several beverages, shampoo, and caffeine tablets. The results obtained by ELISA correlate well with those from liquid chromatography–tandem mass spectrometry (LC–MS–MS) for the tested matrices. Several surface waters from Berlin were analysed and all tested positive for caffeine, with concentrations higher than 0.030 μg L?1. In one run 66 samples can be analysed within 2 h.
Figure
A caffeine ELISA is described that allows sensitive and selective analysis of surface water concentrations as well as determination of caffeine in beverages.  相似文献   

19.
We have developed a surface-enhanced Raman scattering (SERS) probe for the determination of mercury(II) using methimazole-functionalized and cyclodextrin-coated silver nanoparticles (AgNPs). These AgNPs in pH 10 solution containing sodium chloride exhibit strong SERS at 502 cm?1. Its intensity strongly decreases in the presence of Hg(II). This effect serves as the basis for a new method for the rapid, fast and selective determination of trace Hg(II). The analytical range is from 0.50 μg L?1 to 150 μg L?1, and the limit of detection is 0.10 μg L?1. The influence of 11 metal ions commonly encountered in environmental water samples was found to be quite small. The method was applied to the determination of Hg(II) in spiked water samples and gave recoveries ranging from 98.5 to 105.2 % and with relative standard deviations of <3.5 % (n?=?5). The total analysis time is <10 min for a single sample.
Figure
A high-sensitive SERS probe for the determination of Hg2+ using methimazole-functionalized cyclodextrin-protected AgNPs was designed. The limit of detection is 0.10 μg L?1.  相似文献   

20.
We report on a fluorescence polarization assay for the detection of the target analyte ATP by making use of an aptasensor and of mass-amplifying CdTe-CdS quantum dots. The ATP aptamer was modified with digoxin antigen and hybridized with its complementary DNA that was modified with the CdTe-CdS quantum dots. Following the addition of digoxin antibody, the mass-amplifying aptasensor probe is formed as a result of the immuno reaction. In the presence of ATP, the polarization of fluorescence decreases because the digoxin antibody becomes dissociated due to the recognition of the ATP by the ATP aptamer. Under optimized conditions, the method has a linear response to ATP in the 10 to 350 μM concentration range, and the limit of detection is 3.7 μM. The method combines the specific recognition capability of aptamers with the sensitivity of an immunoreaction. It has good selectivity and sensitivity, and can be used to detect ATP in serum samples.
Figure
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号