首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The selectivity tuning of two columns coupled in series is investigated in chiral high-performance liquid chromatography. Two columns with reversal enantioselectivities [(R,R) Whelk-O 1 and (S,S) Whelk-O 1] are coupled in series via a T connector. Selectivity of such a column series is tuned by varying the mobile phase flows in the individual columns. The flow ratio necessary for the required selectivity is calculated on the basis of retention factors measured on the individual columns. The performance of this method for adjusting the required selectivity is studied by the separation of enantiomers of alkoxy substituted esters of phenylcarbamic acid. It is demonstrated that the change of the mobile phase flows in the individual columns enables change in the elution order of enantiomers.  相似文献   

2.
A procedure was developed for modelling the gas chromatographic separation on a system of columns coupled in series. This procedure can be used for computer based optimization of lengths and order of serially coupled columns at isothermal conditions. The sample component retention factors and column resistances needed for the model can easily be measured on each individual column. The proposed procedure was verified by analyzing a 52 component hydrocarbon mixture on three columns of different polarity coupled in series by various column orders. Good agreement between experimental and calculated retention data was found. The procedure is also well suited for optimization of the chromatographic selectivity by coupling columns with different selectivity in series.Dedicated to Professor Dr. h.c. mult. J.F.K. Huber on the occasion of his 70th birthday  相似文献   

3.
The enantioselective tuning of two columns coupled in series is investigated in chiral high-resolution gas chromatography. Two columns with opposite enantioselectivities (Chirasil-L-Val and Chirasil-D-Val) are coupled in series via a T connector, and the relative retention of enantiomers chromatographed on the system is changed by varying the individual carrier gas flow rates in the coupled columns. The flow-rate ratio necessary for the required selectivity is calculated on the basis of the measured retention factors on the individual columns. The performance of this method for adjusting selectivity is studied by the separation of enantiomers of the N-TFA-O-methyl esters of six amino acids. It is demonstrated that the change of the coupling point carrier gas pressure, at the constant inlet and outlet pressures, may change the enantioselectivity of the given column series to such an extent that the enantiomer elution order may be reversed.  相似文献   

4.
Summary This paper reports the qualitative and quantitative effects of the column pressure drop on the retention of lipid components in a serially coupled capillary column SFC system. The contribution of the pressure drop consists of two components, the density effect and the flow effect. The magnitude of the flow effect,i. e. the change in retention which results from changes in the flow-rate when column pressures are changed, is determined by the difference in single column analyte k values. The effect will be positive compared with the uncorrected retention values when the column with largest k value is closest to the injector. With the columns in reversed order, the effect will be negative. The contribution from the density effect always resulted in larger coupled column k values and was in most instances of more significance than the flow effect component. Values calculated with and without pressure drop correction have been compared and it has been shown that for most of the eighteen model lipid compounds investigated, the deviations from the experimental retention factors were smaller when pressure drop corrections were made.  相似文献   

5.
Basic expressions are derived for both the retention time and the effective separation factor in serially coupled GC columns. The retention time is determined by two main parameters. The first is the fractional time spent by an unretarded solute in each column which, in turn, is determined by the relative column lengths and flow velocities through each column. The second parameter is the relative mass distribution coefficient of a particular solute in each column; a variable that can be adjusted by changing the relative temperatures of the columns. The expression for the effective separation factor relates the measured separation factor for the series combination to the separation factors on the individual columns, the fractional time spent by an unretarded peak in each column, as well as the relative values of the mass distribution coefficients of a particular solute on the different columns.  相似文献   

6.
A previous model of column selectivity for reversed-phase liquid chromatography (RP-LC) has been applied to an additional 21 columns with embedded or end-capping polar groups (EPGs). Embedded-polar-group columns exhibit a significantly different selectivity vs. non-EPG, type-B columns, generally showing preferential retention of hydrogen-bond donors, as well as decreased retention for hydrogen-bond acceptors or ionized bases. EPG-columns are also generally less hydrophobic (more polar) than are non-EPG-columns. Interestingly, columns with polar end-capping tend to more closely resemble non-EPG columns, suggesting that the polar group has less effect on column selectivity when used to end-cap the column versus the case of an embedded polar group. Column selectivity data reported here for EPG-columns can be combined with previously reported values for non-EPG columns to provide a database of 154 different columns. This enables a comparison of any two of these columns in terms of selectivity. However, comparisons that involve EPG columns are more approximate.  相似文献   

7.
L. Szepesy  V. Háda 《Chromatographia》2001,54(1-2):99-108
Summary Eight commercially available reversed-phase (RP) columns of widely different characteristics were evaluated and compared using the linear solvation energy relationships (LSER). Retention factors of 32 solutes of different types were determined under isocratic conditions using an acetonitrile-water (30∶70) mobile phase. Stationary phase properties were compared by the fitting coefficients of the LSER-based regression equations which are characteristic of the individual stationary phases and represent the extent of various molecular interactions contributing to the retention process. The good agreement between the calculated and measured logk values for different type of compounds support the adequacy and applicability of the LSER model to describe chromatographic retention. Characterization of column performance for the separation of various type of compounds was established by the determination of the different selectivity factors representing hydrophobic selectivity, polar selectivity and specific selectivity.  相似文献   

8.
Enantiomeric pairs of triticonazole have been successfully separated by supercritical fluid chromatography coupled with a tris(3,5‐dimethylphenylcarbamoyl) cellulose‐coated chiral stationary phase in this work. The effects of co‐solvent, dissolution solvent, flow rate, backpressure, and column temperature have been studied in detail with respect to retention, selectivity, and resolution of triticonazole. As indicated, the co‐solvents mostly affected the retention factors and resolution, due to the different molecular structure and polarity. In addition, the dissolution solvents, namely, chloromethanes and alcohols, have been also important for enantioseparation because of the different interaction with stationary phase. Higher flow rate and backpressure led to faster elution of the triticonazole molecules, and the change of column temperature showed slight effect on the resolution of triticonazole racemate. Moreover, a comparative separation experiment between supercritical fluid chromatography and high performance liquid chromatography revealed that chiral supercritical fluid chromatography gave the 3.5 times value of Rs/tR2 than high performance liquid chromatography, which demonstrated that supercritical fluid chromatography had much higher separation efficiency.  相似文献   

9.
The type of the stationary phase for reversed-phase liquid chromatography significantly affects the sample elution. Hydrodynamic properties, efficiency and gradient elution of proteins were investigated on five commercial C18 columns with wide-pore totally porous particles, with superficially porous layer particles, non-porous particles and a silica-based monolithic bed. The efficiency in the terms of reduced plate height is higher for low-molecular ethylbenzene than for proteins, but depends on the character of the pores in the individual columns tested. The superficially porous Poroshell and the non-porous Micra columns provide the best efficiency for proteins at high mobile phase flow rates, probably because of similar pore architecture in the stationary phase. The Zorbax column with similar pore architecture as the Poroshell active layer, i.e. narrow pore distribution of wider pores shows better efficiency than the packed column with narrow pores and broad pore distribution. The monolithic column shows lower efficiency for proteins at high flow rates, but it performs better than the broad-pore distribution totally porous particulate columns. Different pore architecture affects also the retention and selectivity for proteins on the individual columns. The retention times on all columns can be predicted using the model for reversed-phase gradient elution developed originally for low-molecular compounds. Consideration of the limited pore volume accessible to the biopolymers has negligible effect on the prediction of retention on the columns packed with non-porous or superficially porous particles, but improves the accuracy of the predicted data for the totally porous columns with broad pore distribution.  相似文献   

10.
Retention measurements involving 16 test solutes have been carried out for 38 type-A alkyl-silica columns and three bonded-zirconia columns. These measurements have been analyzed in terms of a model previously developed for type-B columns, so as to yield values of five column selectivity parameters (H, S*, A, B, C) for each type-A column. Overall differences in selectivity between type-A and -B columns can be related to the average values of H, S*, etc. for each column type. Compared to type-B columns, type-A columns provide generally stronger retention for carboxylic acids, while solutes that are more hydrophobic or less bulky are more retained on type-B columns. Hydrogen-bond acceptors (e.g. aliphatic amides) and cations (e.g. protonated bases) are strongly retained on type-A versus type-B columns. Compared to type-B columns, bonded-zirconia columns show much increased retention of cations and reduced retention of hydrogen-bond acceptors. Because of relatively large differences in the selectivity of bonded-zirconia, type-A, and type-B columns, it will prove difficult to find columns of different type (e.g. a type-A and a type-B column) which have equivalent selectivity. Type-A columns also tend to be more different from each other (in terms of selectivity) than is the case for type-B columns. As a result, the replacement of a given type-A column by an "equivalent" type-A column also appears unlikely, except for samples that do not contain ionized compounds.  相似文献   

11.
An empirical test is described for the evaluation of column selectivity in reversed-phase liquid chromatography. Using a test mixture of three polycyclic aromatic hydrocarbons (PAH), overall column selectivity toward PAH was assessed for over 20 different commercial C18 columns. Retention behavior was correlated to phase type (i.e., monomeric and polymeric surface modification chemistry) for custom synthesized phases. A classification scheme is proposed in which commercial C18 columns are grouped into three classes based on retention behavior: monomeric-like, polymeric-like, and intermediate phase selectivity toward PAH. Correlation of retention behavior of the test mixture with the separation of PAH mixtures and with more general column properties (e.g., phase thickness) is discussed.  相似文献   

12.
A comprehensive 2-D-LC-MS method has been developed by coupling columns of different selectivity. The primary column eluate is alternately trapped and sampled onto the secondary columns through a guard column interface. When one guard column traps the eluate, the other injects the previously trapped components onto a secondary column. This cycle is repeated throughout the chromatogram. The use of dual secondary columns provides the secondary columns with additional time to generate high-speed chromatograms. Each secondary column generates alternate chromatograms which when combined generate the entire chromatogram. The primary column separation is comparable to conventional HPLC, whereas the secondary column separation is fast. With both the columns operating in reverse phase mode, one would expect strong correlation in the two-dimensional retention and hence inefficiency in separation. However, differences in column operation modes, interaction mechanisms, and vendor silica result in a complementary separation. The system was evaluated by comparing it to one-dimensional counterparts and coupled column chromatography. Although some correlations were observed in 2-D-LC-MS, peaks do show two-dimensional distribution with superior UV and MS data as co-elution is minimized. Also, the ease of converting conventional systems to 2-D-LC-MS is discussed.  相似文献   

13.
Retention factors k have been measured for 67 neutral, acidic and basic solutes of highly diverse molecular structure (size, shape, polarity, hydrogen bonding, pKa, etc.) on 10 different C18 columns (other conditions constant). These data have been combined with k values from a previous study (86 solutes, five different C8 and C18 columns) to develop a six-term equation for the correlation of retention as a function of solute and column. Values of k can be correlated with an accuracy of +/- 1-2% (1 standard deviation). This suggests that all significant contributions to column selectivity have been identified (and can be measured) for individual alkyl-silica columns which do not have an embedded polar group. That is, columns of the latter kind can be quantitatively characterized in terms of selectivity for use in the separation of any sample.  相似文献   

14.
The isocratic retention of 67 widely-different solutes in reversed-phase liquid chromatography (RP-LC) has been investigated as a function of temperature and mobile phase composition (% B) for three different C18 columns. Similar studies were also carried out in a gradient mode, where temperature, gradient time and solvent type were varied. These results show that changes in retention with these conditions are similar for each of these three columns. This suggests that relative column selectivity as defined by experiments for one set of experimental conditions will be approximately applicable for other conditions, with the exception of changes in mobile phase pH-which can affect values of the column parameter C (a measure of silanol ionization). Column selectivity as a function of pH was explored for several columns.  相似文献   

15.
The retention behavior of a large group of analytes (35) with varied properties (pKa and logP) was studied on eight hydrophilic interaction LC columns with different surfaces, stationary phase chemistries, and types of particles. The acetonitrile content (5–95%), buffer concentration (0.5–200 mM), and pH of the mobile phase (3.8 and 6.8) were evaluated for their effects on the retention behavior. The type of stationary phase had a significant impact on the selectivity and retention time of the tested analytes. Completely different selectivity was observed on the aminopropyl stationary phase. In this study, the influence of the buffer concentration was similar for all tested columns, except for the aminopropyl stationary phase. Increasing the buffer concentration led to decreased retention times for the basic compounds and increased retention times for the acidic compounds, while the inverse behavior was observed on the aminopropyl stationary phase. The selectivity of the individual stationary phases was evaluated at pH 3.8 and 6.8. Much lower selectivity differences between the stationary phases were observed at pH 6.8 than pH 3.8. Bare silica stationary phases were used in the comparison of the particles (fused‐core and fully porous particles of 3 and 1.7 μm) and the columns provided by different manufacturers.  相似文献   

16.
HILIC mode columns were prepared by an on-column polymerization of acrylamide on a monolithic silica capillary column modified with N-(3-trimethoxysilylpropyl)methacrylamide as the anchor group. The products showed HILIC mode retention characteristics with three times greater permeability and slightly higher column efficiency compared to a commercially available amide-type HILIC column packed with 5-μm particles. The selectivity of the monolithic silica-based column was similar to that of the particulate column for each group of solutes towards nucleosides, nucleic bases and carbohydrate derivatives, although a considerable difference was observed in the selectivity for the solute groups. Although the retention of solutes based on the polar functionality was much smaller with the monolithic silica columns, which had a smaller phase ratio, than with the particle-packed column, the former can achieve better separation utilizing the high permeability and higher column efficiencies of a longer column.  相似文献   

17.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

18.
Spray-dried, spherical synthetic hectorite particles have been thermally-treated at 500 degrees C for 16 h and used as adsorbent materials in reversed-phase liquid chromatography. The retention of a 22 mono and disubstituted aromatic compounds was evaluated to study the retention mechanisms on the clay mineral. The retention of solutes on the thermally-treated clays was markedly different than that measured on octadecylsilica (ODS) columns under identical conditions, but remarkably similar to retention characteristics of the same solutes on porous graphitic carbon columns. The clay columns exhibit an enhanced selectivity over the ODS column in separation of nitroaromatic positional isomers. Under identical mobile phase compositions, a selectivity, alpha, of 7.15 between ortho- and para-dinitrobenzene isomers was measured on the clay column compared to a alpha of 1.04 on the ODS column.  相似文献   

19.
The polarity of carbon layer open tubular (CLOT) columns coated with a layer of non-porous graphitized carbon black (Carbopack B) modified with an appropriate amount of polar polyglycol liquid phase has been evaluated and compared with that of standard polar (Supelcowax-10) and non-polar (SPB-1) bonded phase open tubular columns. The efficiency and selectivity were measured at various temperatures and the polarity of the columns was evaluated by use of McReynolds' constants and the difference in apparent carbon number, ΔC of linear alkanes and alcohols. The polarity of the CLOT column was found to depend on temperature, and changing the analytical conditions therefore enabled the separation of compounds of different polarity whose reciprocal position and resolution were affected by temperature. The application of calculation methods which enable programmed temperature retention times to be predicted from isothermal data was also found to be possible when the polarity of the CLOT column changes with temperature.  相似文献   

20.
A series of polycyclic aromatic hydrocarbons (PAHs) of different size and shape has been used to characterize the chromatographic behavior of five calix[4]arene stationary phases in 1,3‐alternate conformation synthesized in our laboratory. The selection of linear, four‐ring nonlinear, and five‐ring PAHs gave data on selectivity changes across range of the calix[4]arene columns. Retention of the 12 aromatic solutes has been evaluated at various methanol contents in the mobile phase (70–100% v/v) and column temperatures (20–45°C). The thermodynamic parameters underlying the retention mechanisms revealed that each of the five calix[4]arene columns exhibited variation in selectivity and retention of PAHs caused by enthalpy and entropy effects. The calixarene stationary phases substituted with electron‐withdrawing groups exhibit enhanced selectivity toward PAHs in comparison to the rest of the investigated columns. The observed divergences are due to differences in solute–stationary phase interactions and originate in π–π and π‐electron transfer specific to the analytes and the type of calix[4]arene functionalization at the upper rim, as well as steric and sorption phenomena.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号