首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Northern and Northeastern Brazil have a natural diversity of fruits, many of which are considered exotic, presenting different flavors and aromas. The enormous diversity of fruits represents a promising area for research on aromas. There is also a great potential for the manufacture of juices, desserts or other processed products. Murici is a typical fruit from these regions presenting a different flavor, reminiscent of that of cheese. This fruit is consumed mainly as juice, ice cream or as liquor, greatly appreciated by the local population. Headspace volatile compounds of three lots of the fruit from Ceará (Fortaleza) were collected by suction on Porapak Q for 2 h and desorbed with 300 microl of acetone. The isolated volatile compounds were separated by high resolution GC. Forty-six volatile compounds were detected, of which 41 were identified by gas chromatography-mass spectrometry and Kovats indices. The most abundant compounds were ethanol (28.3%) and ethyl hexanoate (25.1%). Butanoic acid (5.1%), hexanoic acid (5.1%) and methyl butyrate (2.8%) were also detected in the headspace of the fruit and confirm its unusual cheese aroma.  相似文献   

2.
3.
Solid phase microextraction (SPME) was applied in the development of a protocol for the analysis of a number of target organic compounds in landfill site samples. The selected analytes, including aromatic hydrocarbons, chlorinated hydrocarbous, and unsaturated compounds, were absorbed directly from a headspace sample above a soil layer onto a fused silica fiber. Following exposure, the fiber was thermally desorbed in the injection port of the gas chromatograph and eluted compounds were detected using a mass selective detector. The stability and sensitivity of the extraction technique were examined at five temperatures (22–60°C) using a 100μm polydimethylsiloxane fiber. Calibrations, using soil samples spiked with selected solvents (0.5–30 μg/g), were linear; trichloroethene (r2 = 0.992) and benzene (r2 = 0.998). SPME was applied to the examination of a municipal landfill where 8 sites were sampled, at three depths, resulting in the detection of xylene (maximum 2.8 μg/g) and a number of other non-target organic contaminants.  相似文献   

4.
Analysis of exhaled air is of particular interest as an indicator of health as well as a tool for the diagnosis of diseases. It is also a very attractive procedure for the biological control of the exposition to hazardous solvents. This kind of analysis presents numerous advantages over other methods, the most important being that it is not an invasive procedure and, therefore, it is well accepted and can be applied to a wide range of compounds. Furthermore, the analysis is simplified since the matrix is less complex that in the case of blood or urine. In spite of these obvious advantages and the good results obtained, analysis of exhaled air is not in daily use, probably due to the fact that there are no normalized systems of sampling, thus making the interpretation of the results difficult. In this paper, a method for the determination of tetrachloroethylene in exhaled air using solid-phase microextraction is presented. This method, which can be applied to other volatile organic compounds, was developed with special emphasis of end-exhaled breath sampling. The sample is collected in a glass tube whose ends are closed once the exhalation is finished. The tube has an orifice sealed with a septum through which the fiber is inserted. Then, the fiber is desorbed in the injector of a gas chromatograph and the analysis is accomplished using mass spectrometry for the identification and quantification of the components. The proposed system avoids the need of complex sampling equipment and allows analysis of the alveolar fraction. Additionally, the system is economical and easy to handle, thus facilitating the development of normalized methods and its routine use in field studies.  相似文献   

5.
Experiments and molecular simulations were carried out to study temperature effects (in the range of 323 to 383 K) on the absolute and relative retention of n-hexane, n-heptane, n-octane, benzene, toluene and the three xylene isomers in gas-liquid chromatography. Helium and squalane were used as the carrier gas and retentive phase, respectively. Both the experiments and the simulations show a markedly different temperature dependence of the retention for the n-alkanes compared to the arenes. For example, over the 60 K temperature range studied, the Kovats retention index of benzene is found to increase by about 16 or 18+/-10 retention index units determined from the experiments or simulations, respectively. For toluene and the xylenes, the experimentally measured increases are similar in magnitude and range from 14 to 17 retention index units for m-xylene to o-xylene. The molecular simulation data provide an independent method of obtaining the transfer enthalpies and entropies. The change in retention indices is shown to be the result of the larger entropic penalty and the larger heat capacity for the transfer of the alkane molecules.  相似文献   

6.
Ras MR  Borrull F  Marcé RM 《Talanta》2008,74(4):562-569
The concentrations of seven volatile organic sulfur compounds (VOSCs) in air samples were determined by active collection on multisorbent tubes followed by two-stage thermal desorption and gas chromatography-mass spectrometry. The compounds studied were ethyl mercaptan (CH(3)CH(2)SH), dimethyl sulfide ((CH(3))(2)S), carbon disulfide (CS(2)), propyl mercaptan (C(3)H(8)S), butyl mercaptan (C(4)H(10)S), dimethyl disulfide ((CH(3))(2)S(2)) and 1-pentanethiol (C(5)H(12)S). Active collection on SilcoSteel multisorbent tubes enabled an air volume of 3000ml to be sampled without observing breakthrough. This study focused on an exhaustive sampling of several process steps or sections from sewage management plants. A wide range of concentrations was observed. Dimethyl sulfide, carbon disulfide and dimethyl disulfide were the most abundant compounds in all samples, the highest concentrations being 608.5microg m(-3), 658.5microg m(-3) and 857.8microg m(-3), respectively. The less appearing compound was ethyl mercaptan, which was only detected in the sludge digestion process at a maximum concentration of 14.8microg m(-3). The remaining compounds were detected and measured in about half the samples. The sections with the maximum values of VOSCs involved sludge processes such as mixing, thickening and digestion. The results were also strongly influenced by the design characteristics of the sampling point, e.g. whether the sample was taken at a confined site or in the open air.  相似文献   

7.
A rapid non-destructive sampling technique for the analysis of volatile organic compounds (VOCs) emitted by paper sheets is described. A capillary, which is connected to a microcolumn packed with Tenax TA, is inserted between two sheets at the centre of a paper stack encapsulated inside a PET/Al/PE composite foil. The other end of the microcolumn is connected to a gas-tight syringe and an appropriate volume of gaseous phase is aspirated. The microcolumn is then thermally desorbed in a modified GC inlet (modification is presented) and analysed by gas chromatography-mass spectrometry (GC-MS). In the chromatogram from the analysis of artificially aged paper sample 21 compounds were identified. Advantages of the method including the short sampling time (1 min), simplicity and economic aspect are discussed.  相似文献   

8.
Derivative spectrophotometry was applied to solid-phase spectrophotometry in order to enhance its sensitivity and remove the large background noise caused by the absorption of the resin layer itself, and avoid the necessity of preparing a blank. The determination of micro-amounts of molybdenum (at the ng ml(-1) level) with pyrocatechol violet to form a 11 blue complex in acid medium, which is fixed on a dextran-type anion-exchange resin (Sephadex QAE-A-25), is described as an example of the application of this technique. The absorbance of the resin, packed in a 1 mm spectrophotometric cell, was measured directly. The characteristic peak amplitude of the signal at 716 nm in the first-derivative spectra is useful for quantitative determination of molybdenum (2-8 ng ml(-1); RSD = 4, 30%) in natural and industrial water samples, plant tissues and soil extracts.  相似文献   

9.
A relatively noninvasive method consisting of a face mask sampling device, solid-phase microextraction (SPME) fibers, and a gas chromatography-mass spectrometry (GC-MS) for the identification of volatile organic compounds (VOCs) in bovine breath was developed. Breath of three morbid steers with respiratory tract infections and three healthy steers were sampled seven times in 19 days for 15 min at each sampling. The breath VOCs adsorbed on the divinylbenzene (DVB)-Carboxen-polydimethyl siloxane (PDMS) 50/30 microm SPME fibers were transported to a laboratory GC-MS system for separation and identification with an in-house spectral library of standard chemicals. A total of 21 VOCs were detected, many of them for the first time in cattle breath. Statistical analyses using Chi-square test on the frequency of detection of each VOC in each group was performed. The presence of acetaldehyde (P < or = 0.05) and decanal (P < or = 0.10) were associated more with clinically morbid steers while methyl acetate, heptane, octanal, 2,3-butadione, hexanoic acid, and phenol were associated with healthy steers at P < or = 0.10. The results suggest that noninvasive heath screening using breath analyses could become a useful diagnostic tool for animals and humans.  相似文献   

10.
The aroma profile of cocoa products was investigated by headspace solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS). SPME fibers coated with 100 μm polydimethylsiloxane coating (PDMS), 65 μm polydimethylsiloxane/divinylbenzene coating (PDMS-DVB), 75 μm carboxen/polydimethylsiloxane coating (CAR-PDMS) and 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane on a StableFlex fiber (DVB/CAR-PDMS) were evaluated. Several extraction times and temperature conditions were also tested to achieve optimum recovery. Suspensions of the samples in distilled water or in brine (25% NaCl in distilled water) were investigated to examine their effect on the composition of the headspace. The SPME fiber coated with 50/30 μm DVB/CAR-PDMS afforded the highest extraction efficiency, particularly when the samples were extracted at 60 °C for 15 min under dry conditions with toluene as an internal standard. Forty-five compounds were extracted and tentatively identified, most of which have previously been reported as odor-active compounds. The method developed allows sensitive and representative analysis of cocoa products with high reproducibility. Further research is ongoing to study chocolate making processes using this method for the quantitative analysis of volatile compounds contributing to the flavor/odor profile.  相似文献   

11.
A method is described for simultaneous determination of semivolatile organic compounds (SVOCs) in indoor air by gas chromatography-mass spectrometry (GC-MS). The selected 73 SVOCs were collected using combined adsorbents (quartz fiber filter disk and Empore disk) for 24 h at a 5.0 l/min flow rate. The SVOCs collected were extracted with acetone, concentrated, then analyzed by an internal standard method. Forty compounds (19 plasticizers and flame retardants; 19 insecticides; 1 synergist; and 1 fungicide) among the target SVOCs were determined accurately and precisely. The method of detection limits for these compounds were approximately 0.5 ng/m3 for most of the SVOCs. The collected SVOC samples could be stored for up to 1 month at 4 C in the refrigerator.  相似文献   

12.
A multipurpose sampler (Gerstel MPS), designed for liquid large volume, gaseous and headspace samples was used for the GC-MS analysis of organic volatiles in human urine. Headspace sampling with a volume-, temperature- and speed-controlled gas-tight syringe was combined with a temperature-controlled cold injection system (CIS) for cold trapping, enrichment and focusing of analytes. Regular 2-ml GC vials filled with 1 ml acidified urine were used as headspace sampling vials. A 100-vial autosampler tray was equipped with an additional temperature and heating time controlled "preheating station" for five vials. Profiles of organic volatiles in human urine were determined and 34 components identified. Trimethylamine (TMA) and 4-heptanone as two metabolites of medical interest were quantified. Calibration curves and intra assay imprecision for 4-heptanone concentrations in the range of 40 to 800 ng/ml showed a correlation coefficient of r = 0.9980 and a relative standard deviation (RSD) between 3.0 and 3.4%. Calibration curves and intra-assay imprecision for TMA concentrations in the range of medical interest from 0.5 to 20 micrograms/ml showed a correlation coefficient of r = 0.9968 and a RSD between 4.1 and 6.8%. The high practicability of the multipurpose sampler for both gaseous and liquid samples together with the here shown good reproducibility and sensitivity make this single CIS-GC-MS system very attractive for routine clinical use in metabolic profiling of organic volatiles (headspace) and non-volatiles (liquid).  相似文献   

13.
A sensitive and reliable method is described for the determination of aromatic and chlorinated hydrocarbons (benzene, toluene, o-, m-, p-xylene, trichloromethane, trichloroethane, trichloroethene and tetrachloroethene) in indoor and outdoor air at environmental concentration levels. The procedure can be easily extended to other VOCs. Using passive samplers the VOCs have been adsorbed onto charcoal during a four-week sampling period and subsequently desorbed with carbon disulfide. After injection with a cold split-splitless multi-injector the VOCs have been separated by capillary gas chromatography. Quantification has been achieved using an electron capture detector (ECD) and a flame ionization detector (FID) switched in series. A limit of about 1 g/m3 for aromatic hydrocarbons and of about 0.01 g/m3 for chlorinated hydrocarbons has been obtained. The procedure has been successfully applied in the framework of a field study to measure indoor and outdoor air concentrations in Essen and Borken, two differently polluted areas of Northrhine-Westphalia.  相似文献   

14.
A method is presented for the selective determination of the volatile selenium species dimethylselenide and dimethyldiselenide, using a commercially available purge-and-trap injection system coupled to capillary gas chromatography-microwave induced plasma-atomic emission spectrometry. The efficiency of the purging step was evaluated and the parameters affecting the purge and trap processes were optimized. The method was applied to the determination of volatile selenium compounds in lake water. Relative detection limits of 2ng/l for dimethylselenide and dimethyldiselenide, corresponding to an absolute detection limit of 10 pg, were achieved.  相似文献   

15.
The solvation parameter model is used to characterize the separation characteristics of two application-specific open-tubular columns (Rtx-Volatiles and Rtx-VGC) and a general purpose column for the separation of volatile organic compounds (DB-WAXetr) at five equally spaced temperatures over the range 60-140 degrees C. System constant differences and retention factor correlation plots are then used to determine selectivity differences between the above columns and their closest neighbors in a large database of system constants and retention factors for forty-four open-tubular columns. The Rtx-Volatiles column is shown to have separation characteristics predicted for a poly(dimethyldiphenylsiloxane) stationary phase containing about 16% diphenylsiloxane monomer. The Rtx-VGC column has separation properties similar to the poly(cyanopropylphenyldimethylsiloxane) stationary phase containing 14% cyanopropylphenylsiloxane monomer DB-1701 for non-polar and dipolar/polarizable compounds but significantly different characteristics for the separation of hydrogen-bond acids. For all practical purposes the DB-WAXetr column is shown to be selectivity equivalent to poly(ethylene glycol) columns prepared using different chemistries for bonding and immobilizing the stationary phase. Principal component analysis and cluster analysis are then used to classify the system constants for the above columns and a sub-database of eleven open-tubular columns (DB-1, HP-5, DB-VRX, Rtx-20, DB-35, Rtx-50, Rtx-65, DB-1301, DB-1701, DB-200, and DB-624) commonly used for the separation of volatile organic compounds. A rationale basis for column selection based on differences in intermolecular interactions is presented as an aid to method development for the separation of volatile organic compounds.  相似文献   

16.
This paper presents a detailed study on the calibration of a thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS)-based methodology for quantification of volatile organic compounds (VOCs) in gaseous and liquid samples. For the first time, it is documented to what extent three widely encountered problems affect precise and accurate quantification, and solutions to improve calibration are proposed. The first issue deals with the limited precision in MS quantification, as exemplified by high relative standard deviations (up to 40%, n=5) on response factors of a set of 69 selected VOCs in a volatility range from 16 Pa to 85 kPa at 298 K. The addition of [(2)H(8)]toluene as an internal standard, in gaseous or liquid phase, improves this imprecision by a factor of 5. Second, the matrix in which the standard is dissolved is shown to be highly important towards calibration. Quantification of gaseous VOCs loaded on a sorbent tube using response factors obtained with liquid standards results in systematic deviations of 40-80%. Relative response factors determined by the analysis of sorbent tubes loaded with both analytes and [(2)H(8)]toluene from liquid phase are shown to offer a reliable alternative for quantification of airborne VOCs, without need for expensive and often hardly available gaseous standards. Third, a strategy is proposed involving the determination of a relative response factor being representative for a group of analytes with similar functionalities and electron impact fragmentation patterns. This group method approach indicates to be useful (RSD approximately 10%) for quantifying analytes belonging to that class but having no standards available.  相似文献   

17.
This study describes the optimisation of an analytical method to determine 54 volatile organic compounds (VOCs) in air samples by active collection on multisorbent tubes, followed by thermal desorption and gas chromatography-mass spectrometry. Two multisorbent beds, Carbograph 1/Carboxen 1000 and Tenax/Carbograph 1TD, were tested. The latter gave better results, mainly in terms of the peaks that appeared in blank chromatograms. Temperatures, times and flow desorption were optimised. Recoveries were higher than 98.9%, except methylene dichloride, for which the recovery was 74.9%. The method's detection limits were between 0.01 and 1.25 μg m−3 for a volume sample of 1200 ml, and the repeatability on analysis of 100 ng of VOCs, expressed as relative standard deviation for n = 3, was lower than 4% for all compounds. Urban and industrial air samples from the Tarragona region were analysed. Benzene, toluene, ethylbenzene and xylenes (BTEX) were found to be the most abundant VOCs in urban air. Total VOCs in urban samples ranged between 18 and 307 μg m−3. Methylene chloride, 1,4-dichlorobenzene, chloroform and styrene were the most abundant VOCs in industrial samples, and total VOCs ranged between 19 and 85 μg m−3.  相似文献   

18.
A quantitative method has been developed for the determination of trace levels (<50 microg/kg) of acrylamide in cereal-based foods. The method is based on extraction of acrylamide with water, acidification and purification with Carrez I and II solutions, followed by bromination of the acrylamide double bond. The reaction product (2,3-dibromopropionamide) is extracted with ethyl acetate/hexane (4:1, v/v), dried over sodium sulfate, and cleaned up through a Florisil column. The derivative is then converted to 2-bromopropenamide by dehydrobromination with triethylamine and analyzed by gas chromatography coupled to mass spectrometry (GC-MS), employing (13C3)acrylamide as internal standard. In-house validation data for commercial and experimental cereal products showed good precision of the method, with repeatability and intermediate reproducibility relative standard deviations below 10%. The limit of detection and limit of quantitation are estimated at 2 and 5 microg/kg, respectively, and recoveries of acrylamide from samples spiked at levels of 5-500 microg/kg ranged between 93 and 104% after correction of analyte loss by the internal standard. Finally, a comparative test organized with two independent laboratories provided additional confidence in the good performance of the method, particularly at very low concentration levels.  相似文献   

19.
A new method based on the use of a headspace autosampler in combination with a GC equipped with a programmable temperature vaporizer (PTV) and an MS detector has been developed for the screening and quantitative determination of trihalomethanes (THMs) in different aqueous matrices. The use of headspace generation to introduce the sample has the advantage that no prior sample treatment is required, thus minimizing the creation of analytical artifacts and the errors associated with this step of the analytical process. The PTV inlet used was packed with Tenax-TA. The injection mode was solvent vent, in which the analytes are retained in the hydrophobic insert packing by cold trapping, while the water vapour is eliminated through the split line. This allows rapid injection of the sample in splitless mode, very low detection limits being achieved without the critical problem of initial sample bandwidth. The capillary column used allowed rapid separations with half-height widths ranging from 1.68 s (chloroform) to 0.66 s (bromoform). The GC run time was 7.3 min. The use of mass spectrometry allows the identification and quantification of the analytes at the low ppt level. The S/N ratio was at least 10-fold higher when the SIM mode was used in data acquisition as compared to the scan mode. The proposed method is extremely sensitive, with detection limits ranging from 0.4 to 2.6 ppt.  相似文献   

20.
吹扫捕集-GC-MS-SIM法测定水中挥发性硫化合物   总被引:8,自引:0,他引:8  
建立了水中的二硫化碳(CS2)、甲硫醚(DMS)和二甲二硫醚(DMDS) 3种挥发性硫化合物分析方法.采用吹扫-捕集对水中的被测成分进行预富集,然后导入GC-MS系统中在选择离子模式(SIM)下进行检测.CS2、DMS和DMDS 3种硫化合物分别在0.03~3.42 μg/L,0.17~2.72 μg/L和0.04~3.41 μg/L范围内线性关系良好,相关系数r分别为0.9967、0.9930和0.9959;在不同的浓度下,平行测定5次后的相对标准偏差均小于6.0%;方法检出限为3.75,11.33和2.10 ng/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号