首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Consumption of selenium enriched plants or yeast-based nutritional supplements has been reported to provide anticarcinogenic benefits which are selenium compound dependent. Separation and identification of these selenium compounds is critical to understand the activity. Plants and yeast convert inorganic selenium in the soil or growth media into organoselenium compounds, probably following a route similar to the sulfur assimilatory pathway. Non-volatile selenium compounds produced include selenoamino acids, some of which have shown anticarcinogenic activity. Volatile compounds produced by chemical reaction of involatile precursors have also been found. An ion pair chromatographic method with ICP-MS detection for the separation of selenoamino acid standards potentially present in real samples is given. The method allows separation of selenoamino acids including such analytes as the cis-trans isomers of Se-1-propenyl-dl-selenocysteine. The method also provides the capability of determining the presence of selenoxides and possibly selenones, and tracking of other functionalities and reactions by selective derivatization. Alternatively, selenoamino acids are treated with ethylchloroformate to produce stable volatile derivatives which are amenable to GC separation with element specific atomic emission detection (GC-AED). Results of total selenium determination and speciation of selenium enriched yeast-based nutritional supplements, selenium enriched allium vegetables and bioremediation samples are presented. Received: 16 February 1998 / Revised: 4 June 1998 / Accepted: 9 June 1998  相似文献   

2.
Consumption of selenium enriched plants or yeast-based nutritional supplements has been reported to provide anticarcinogenic benefits which are selenium compound dependent. Separation and identification of these selenium compounds is critical to understand the activity. Plants and yeast convert inorganic selenium in the soil or growth media into organoselenium compounds, probably following a route similar to the sulfur assimilatory pathway. Non-volatile selenium compounds produced include selenoamino acids, some of which have shown anticarcinogenic activity. Volatile compounds produced by chemical reaction of involatile precursors have also been found. An ion pair chromatographic method with ICP-MS detection for the separation of selenoamino acid standards potentially present in real samples is given. The method allows separation of selenoamino acids including such analytes as the cis-trans isomers of Se-1-propenyl-dl-selenocysteine. The method also provides the capability of determining the presence of selenoxides and possibly selenones, and tracking of other functionalities and reactions by selective derivatization. Alternatively, selenoamino acids are treated with ethylchloroformate to produce stable volatile derivatives which are amenable to GC separation with element specific atomic emission detection (GC-AED). Results of total selenium determination and speciation of selenium enriched yeast-based nutritional supplements, selenium enriched allium vegetables and bioremediation samples are presented.  相似文献   

3.
We report a technique for isolation and solubilization of intermediate filament (IF) proteins from colonic biopsies compatible with both gel electrophoresis and liquid chromatography "shotgun" proteomics using mass spectrometry (MS). This is important because changes in the IF proteome, particularly in keratin expression and modification, are noted in colonic mucosa of patients with colorectal cancer. Though keratins have traditionally been dissolved in high concentration of urea, the latter solvent precludes efficient proteolytic digestion by trypsin prior to gel-free LC-MS/MS approaches. The extraction of cytoskeletal proteins was initially evaluated using MCF-7 cancer cell lines using a published, differential detergent solubilization protocol. IF proteins were extracted from colonic biopsies using a combination of homogenization and sonication. Since comparable efficiency of solubilization was noted on the extracted IF from cell lines between urea and guanidine hydrochloride (GuHCl) in triethylammonium bicarbonate buffer, isolated proteins from endoscopic biopsies were solubilized in GuHCl. Using immunoblotting techniques, we successfully demonstrated isolation of keratins and preservation of posttranslational modifications (phosphorylation, acetylation). Dissolved proteins were tryptically digested and peptides analyzed by MS, showing the functionality of the workflow in shotgun proteomic applications, specifically compatibility of the workflow for isobaric tagging relative and absolute quantification based quantitation approaches.  相似文献   

4.
Radionuclide detection by mass spectrometric techniques offers inherent advantages over conventional radiation detection methods. Since radionuclides decay at variable rates (half-lives) and via various nuclear transformations (i.e. emission of alpha-, beta-, and/or gamma-radiation) their determination via radiation detection depends not only on decay systematics but also on detector technology. Radionuclide detection by directatom measurement, however, is dependent only on technique sensitivity and is indifferent to decay mode. Evaluation of inductively coupled plasma mass spectrometry (ICP/MS) indicates this method to be superior to conventional radiation detection techniques for many radionuclides. This work discusses factors which influence detection by both methods. Illustrative applications of ICP/MS to the ultra-trace determination of several radionuclides, including129I, are presented.Operated for the U.S. Department of Energy by Battelle Memorial Institute under contract De-AC06-76RLO 1830.  相似文献   

5.
In this paper a novel workflow-based data acquisition and control system for Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is presented that facilitates a fast on-the-fly decision-making process for a wide variety of data-dependent experiments. Several new workflow implementations demonstrate the flexibility and benefit of this approach for rapid dynamic experimental design on a chromatographic timescale. The different sequence, evaluation, decision and monitoring modules are described using a selected set of examples. During a tandem liquid chromatography (LC)/FTICR-MS experiment the system is used to dynamically switch between various dissociation techniques such as electron capture dissociation (ECD) and sustained off-resonance irradiation (SORI) depending on the charge state of a tryptic peptide peak. The use of this workflow-based system for imaging FTICR-MS using a desorption electrospray ionization (DESI) source demonstrates the possibility of external control of the workflow by feedback from an imaging sample stage.  相似文献   

6.
Summary Mechanisms responsible for atomization of selenium in graphite furnaces and for stabilization that occurs when nickel is added to selenium are investigated by mass analyzing, in real-time, the gaseous species from furnaces heated in vacuum and in atmospheric pressure environments. For the latter case, the analysis is done on a molecular beam formed from free-jet expansion of gases from the furnace. The apparatus for doing this is described. Results from the two experimental techniques, when compared, indicate that the primary loss of selenium at low temperatures is from thermal dissociation of selenium dicarbide. Secondary losses are due to vaporization of the dimer and the oxides. Nickel nitrate inhibits formation of the dicarbide, the dimer and the oxides. Mechanisms that are responsible for these findings are postulated.
Untersuchung von Atomisierungsmechanismen durch simultane Massenspektrometrie und AAS
Zusammenfassung Die Mechanismen der Atomisierung von Selen in Graphitöfen und der Stabilisierung durch Nickelzusatz wurden durch Echtzeit-Massenanalyse der aus dem Ofen (Vakuum oder Atmosphärendruck) austretenden Gase untersucht. Im letzteren Fall wird die Analyse im austretenden Molekularstrahl durchgeführt. Das verwendete Gerät wird beschrieben. Die Ergebnisse der beiden Techniken zeigen, daß der primäre Selenverlust bei niederen Temperaturen von der thermischen Dissoziation von Selendicarbid herrührt. Sekundäre Verluste werden durch Verdampfung des Dimeren und der Oxide verursacht. Nickelnitrat verhindert die Bildung des Dicarbids, des Dimeren und der Oxide. Mechanismen für diese Vorgänge werden formuliert.


This paper is based on work sponsored by the Division of Chemical Sciences of the Department of Energy and performed under DOE Contract No. DE-AC06-76RLO-1830  相似文献   

7.
Le XC  Cullen WR  Reimer KJ 《Talanta》1994,41(4):495-502
An arsenic specific detection system utilizing on-line microwave digestion and hydride generation atomic absorption spectrometry (MD/HGAAS) is described for arsenic speciation by using high performance liquid chromatography (HPLC). Both ion exchange chromatography and ion pair chromatography have been studied for the separation of arsenite, arsenate, monomethylarsonic acid (MMAA), dimethylarsinic acid (DMAA), and arsenobetaine (AB). When the commonly used mobile phases, phosphate and carbonate buffers at pH 7.5, are used on an anion exchange column, arsenite and AB co-elute. However, selective determination of these two arsenic compounds can be achieved by using the new detection system. Partial separation between arsenite and AB can be achieved by increasing the mobile phase pH to 10.3 and by using a polymer based anion exchange column. The detection limit obtained by using anion exchange chromatography with MD/HGAAS detection is approximately 10 ng/ml (or 200 pg for a 20-mul sample injection) for arsenite, DMAA and AB, 15 ng/ml (or 300 pg) for MMAA, and 20 ng/ml (or 400 pg) for arsenate. Complete separation of the five arsenic compounds is achieved on a reversed phase C18 column by using sodium heptanesulfonate as ion pair reagent. Comparable resolution between chromatographic peaks is obtained by using MD/HGAAS detection and inductively coupled plasma mass spectrometry (ICPMS) detection.  相似文献   

8.
9.
Meat adulteration detection is a common concern of consumers. Here, we proposed a multiplex digital polymerase chain reaction method and a low-cost device for meat adulteration detection. Using a polydimethylsiloxane microfluidic device, polymerase chain reaction reagents could be pump-free loaded into microchambers (40 × 40 chambers) automatically. Due to the independence of multiplex fluorescence channels, deoxyribonucleic acid templates extracted from different animal species could be distinguished by one test. In this paper, we designed primers and probes for four types of meat (beef, chicken, pork, and duck) and labeled each of the four fluorescent markers (hexachlorocyclohexane [HEX], 6-carboxyfluorescein [FAM], X-rhodamine [ROX], and cyanine dyes 5 [CY5]) on the probes. Specific detection and mixed detection experiments were performed on four types of meat, realizing a limit of detection of 3 copies/µL. A mixture of four different species can be detected by four independent fluorescence channels. The quantitative capability of this method is found to meet the requirements of meat adulteration detections. This method has great potential for point-of-care testing together with portable microscopy equipment.  相似文献   

10.
A new gas chromatograph‐atomic emission detector (GC‐AED) coupled with Deans switching technique for analyzing volatiles from tobaccos were developed. The detector operating parameters (reagent gas pressure and make‐up gas flow rate) were optimized. The detection limits for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) ranged 0.05–0.2, 0.05–0.3 and 1–11 ng, respectively, depending on the compound. The sensitivity and linearity for the elements carbon (193 nm), hydrogen (486 nm) and oxygen (171 nm) decreased in the order O>H>C. Calibration curves were obtained by plotting peak area versus concentration, and the correlation coefficients relating to linearity were at least 0.9359. Elemental response factors measured on these channels, relative to the carbon 193‐nm channel, were hydrogen, 0.38–0.48 (mean %RSD=5.64), and oxygen, 0.085–0.128 (mean %RSD=14.9). The evaluation was also done for the new technique and for an established GC‐MS technique for the same real samples. The results of GC‐AED and GC‐MS showed that there was a relatively good agreement between the two sets of data.  相似文献   

11.
12.
Inductively coupled plasma mass spectrometry (ICP/MS) is utilized as a detector for several organotin species separated by high-performance liquid chromatography. Detection limits obtained by ICP/MS are 3 orders of magnitude lower than those obtained with inductively coupled plasma atomic emission spectrometry (ICP/AES) detection under the same chromatographic conditions. Chromatographic detection limits are higher than conventional solution nebulization for the same compound by a factor of 20. Ion-exchange chromatography yields linear response over 3 orders of magnitude, while ion pair chromatography gives a linear response of only 2 orders of magnitude as a result of poor resolution. The relative standard deviation for the injection of 20 ng of tin compounds is less than 10%.  相似文献   

13.
Glycosphingolipids (GSLs) are amphiphilic molecules consisting of a hydrophilic carbohydrate chain and a hydrophobic ceramide moiety. They appear to be involved primarily in biological processes such as cell proliferation, differentiation, and signaling. To investigate the mechanism of brain function in more detail, a more highly sensitive method that would reveal the GSL distribution in the brain is required. In this report, we describe a simple and efficient method for mapping the distribution and localization of GSLs present in mouse brain sections using nanoparticle-assisted laser desorption/ionization imaging mass spectrometry (IMS). We have developed and tested gold nanoparticles (AuNPs) as a new matrix to maximize the detection of GSLs. A matrix of AuNPs modified with alkylamine was used to detect various GSLs, such as minor molecular species of sulfatides and gangliosides, in mouse brain sections; these GSLs were hardly detected using 2,5-dihydroxybenzoic acid (DHB), which is the conventional matrix for GSLs. We achieved approximately 20 times more sensitive detection of GSLs using AuNPs compared to a DHB matrix. We believe that our new approach using AuNPs in IMS could lead to a new strategy for analyzing basic biological mechanisms and several diseases through the distribution of minor GSLs.  相似文献   

14.
Recently, we reported that significant ion loss occurs prior to detection in conventional single particle mass spectrometry. A more serious type of loss is ion-kinetic-energy-dependent loss. This leads to significant errors in the measured chemical composition of nanoparticles, especially when they have a core-shell structure. In this paper, a novel ion optics for effective detection of ions generated from a single nanoparticle is designed. Using the commercial software SIMION, the trajectories of ions launched at different speeds inside a single particle mass spectrometer are simulated. The effects of changes are investigated with different repelling plates, Einzel lens additions, and substitutions of the tube electrode between extraction and acceleration grids on the ion flight. The best design was found when assembling the trials in the present condition. It was demonstrated experimentally that the new ion optics works well not only in theory, but also in practice.  相似文献   

15.
16.
A multipath liquid chromatography with mass spectrometry instrument was constructed with the help of restricted access media to online segregate small and large molecules. This liquid chromatography system was custom built with five pumps and three two‐position six‐port valves to control the flow in a multipath system for the simultaneous analysis of small molecules and proteins. On separate chromatographic channels, small molecules trapped and proteins excluded from the online restricted access media were analyzed downstream using high‐efficiency columns and a triple quadrupole mass spectrometer. A model sample, which included five proteins and 22 small molecules with different physicochemical properties, was used to evaluate the system. Following injection, the complete multipath separation and detection was performed in 22 min. Protein exclusion by the restricted access media was not quantitative. Four commercial trap columns were evaluated for their exclusion efficiency toward the proteins. Exclusion efficiency varied from <50% to only a maximum of 75% exclusion across the trap columns tested. An attempt was made to optimize the exclusion efficiency using different flow rates, flow rate gradients, and different additives both in the sample and the mobile phases. Protein exclusion was still erratic and generally nonquantitative.  相似文献   

17.
A method is presented for extracting individual component spectra from gas chromatography/mass spectrometry (GC/MS) data files and then using these spectra to identify target compounds by matching spectra in a reference library. It extends a published “model peak” approach which uses selected ion chromatograms as models for component shape. On the basis of this shape, individual mass spectral peak abundance profiles are extracted to produce a “purified” spectrum. In the present work, ion-counting noise is explicitly treated and a number of characteristic features of GC/MS data are taken into account. This allows spectrum extraction to be reliably performed down to very low signal levels and for overlapping components. A spectrum match factor for compound identification is developed that incorporates a number of new corrections, some of which employ information derived from chromatographic behavior. Test results suggest that the ability of this system to identify compounds is comparable to that of conventional analysis.  相似文献   

18.
MALDI imaging mass spectrometry (MALDI-IMS) has become a powerful tool for the detection and localization of drugs, proteins, and lipids on-tissue. Nevertheless, this approach can only perform identification of low mass molecules as lipids, pharmaceuticals, and peptides. In this article, a combination of approaches for the detection and imaging of proteins and their identification directly on-tissue is described after tryptic digestion. Enzymatic digestion protocols for different kinds of tissues—formalin fixed paraffin embedded (FFPE) and frozen tissues—are combined with MALDI-ion mobility mass spectrometry (IM-MS). This combination enables localization and identification of proteins via their related digested peptides. In a number of cases, ion mobility separates isobaric ions that cannot be identified by conventional MALDI time-of-flight (TOF) mass spectrometry. The amount of detected peaks per measurement increases (versus conventional MALDI-TOF), which enables mass and time selected ion images and the identification of separated ions. These experiments demonstrate the feasibility of direct proteins identification by ion-mobility-TOF IMS from tissue. The tissue digestion combined with MALDI-IM-TOF-IMS approach allows a proteomics “bottom-up” strategy with different kinds of tissue samples, especially FFPE tissues conserved for a long time in hospital sample banks. The combination of IM with IMS marks the development of IMS approaches as real proteomic tools, which brings new perspectives to biological studies.  相似文献   

19.
20.
Procedures for the analysis of molybdenum oxide by of inductively coupled plasma atomic emission spectroscopy (ICP-AES) and mass spectrometry (ICP-MS) are proposed on the basis of preliminary extraction separation of molybdenum from impurity elements. To separate 39 impurity elements (Li, Be, Na, Mg, Al, K, Ca, Sc, Ti, Cr, Mn, Fe, Co, Ni, Zn, Ga, Rb, Sr, Y, Cd, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Pb, Bi, Th, and U), the extraction of molybdenum from hydrochloric acid solutions using 5-n-pentylthio-8-hydroxyquinoline was used. The capacities of both methods ICP-AES and ICP-MS in the analysis of molybdenum oxide analysis were examined without the removal of the matrix and after the extraction separation of molybdenum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号