共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of Electrostatics》2014,72(5):387-395
In this work, analysis of the human body exposed to high voltage electric and magnetic fields is presented. The distribution of the electric field is obtained by using Laplace's equation. This relates the surface charge induced on the body to the potential in a reciprocal Laplace problem, which is then calculated by charge simulation method coupled with genetic algorithms to determine the appropriate arrangement of simulating charges inside the human body. The magnetic field intensity along the vertical center line of the human is calculated. Exposure to external electric and magnetic fields at power frequency induces electric field, magnetic field and currents inside the human body. The presented model for simulating electric and magnetic fields are a three dimensional field problem and introduced different types of charges to simulate the different elementary geometrical shapes of human body. The particular strength of the charge simulation method in this application is its ability to allow a detailed representation of the shape and posture of the human body. The results have been assessed through comparison induced current, electric field, magnetic field and there distribution over the body surface, as estimated in other experimental and computational work. 相似文献
2.
T.Whit Athey Ph.D. Ronald J. Ross M.D. Paul S. Ruggera P.E. 《Magnetic resonance imaging》1982,1(3):149-154
Measurements were made of magnetic and electric field levels in and around a nuclear magnetic resonance imaging system undergoing a clinical trial. Magnetic field levels ranged from 0.04 tesla (T) in the imaging volume down to about 0.0006 T at the end of the patient table. The peak radio-frequency magnetic field level was 15 amperes per meter (A/m) in the imaging volume, while the rms value was 4.6 A/m. The specific absorption rate resulting from the radio-frequency magnetic field was calculated to be no more than 0.017 watts per kilogram (W/kg). The radio-frequency electric field was detectable only within a few centimeters of the coil assembly, and does not significantly contribute to the specific absorption rate. These exposure levels were much lower than existing guidelines for clinical NMR procedures. 相似文献
3.
Dietmar Glogar Sebastian Globits Andreas Neuhold Harald Mayr 《Magnetic resonance imaging》1989,7(6):611-617
To evaluate the potential of magnetic resonance imaging (MRI) in detection and quantification of mitral regurgitation, 26 pts. with echocardiographically or angiographically documented mitral regurgitation were examined using a 0.5 Tesla superconducting magnet. In each patient a multislice-multiphase study in a sagittal-coronal double angulated projection (four-chamber view equivalent) was performed to assess left and right ventricular volumes, ejection fraction and regurgitant fraction. Additionally a blood flow sensitive cine-study (fast field echo: FFE) was done to visualize direction and area of regurgitant jet. MRI data were compared with quantitative and qualitative assessment of mitral regurgitation by angiography, 2D echocardiography, Doppler sonography and color flow mapping. Using the FFE mode MRI was able to detect the regurgitant jet as a typical signal loss within the left atrium in all patients. The ratio of regurgitant jet area/left atrium area as determined by MRI showed a correlation with a comparable ratio from color Doppler sonography of R = 0.87 (p < 0.001). There was also good agreement in semiquantitative grading of mitral regurgitation between MRI and angiography (R = 0.77, p < 0.001). The determination of left and right ventricular stroke volume allowed the calculation of the regurgitant fraction, which showed a correlation with invasively determined regurgitation fraction of R = 0.84 (p < 0.001). These data provide additional information that MRI may be useful as a noninvasive technique to detect and quantify mitral regurgitation. 相似文献
4.
Mikko I. Kettunen Kevin M. Brindle 《Progress in Nuclear Magnetic Resonance Spectroscopy》2005,47(3-4):175-185
5.
Specialized implants are used for transcatheter closure of septal defects, including atrial and ventricular septal defects, and patent foramen ovale. These metallic devices may pose a risk to patients undergoing magnetic resonance imaging (MRI) procedures especially if performed at 3 T. Therefore, this investigation evaluated MRI safety at 3 T for septal repair implants (CardioSEAL Septal Repair Implant and STARFlex Septal Repair Implant, NMT Medical, Boston, MA, USA) by characterizing magnetic field interactions, heating and artifacts. These implants exhibited minor magnetic field interactions; heating was not excessive (+0.5°C); and artifacts will only create a problem if the area of interest is in the same area as or near these devices. Thus, the findings indicated that it would be safe for a patient with these implants to undergo MRI at 3 T or lower. Importantly, because of the minor magnetic field interactions, MRI may be performed immediately after implantation. 相似文献
6.
Gary D. Fullerton 《Magnetic resonance imaging》1982,1(1):39-53
The basic concepts necessary to understand the physical basis of NMR imaging are presented in this didactic article. It is intended as a starting point for the radiologist or medical physicist who is addressing the topic of NMR for the first time. The basis of the NMR phenomena is described with introduction of the concepts of magnetic moment, magnetic fields, magnetic resonance, net magnetic moment of a sample, NMR excitation and NMR emission. The equipment necessary to observe these NMR properties of matter is summarized as well as the procedures for basic pulsed NMR experiments. The physical concepts for spatial localization of NMR emissions are introduced with physical analogies to stringed musical instruments. Several alternative imaging modalities are compared with greatest emphasis on the inversion recovery technique which yields images weighted by tissue T1 values. The six subsystems of an NMR imaging device (primary magnet, computer, radio equipment, magnetic gradient, data storage and display subsystems) are described in an overview fashion. The paper is followed by a series of study questions to test the reader's comprehension of basic NMR imaging concepts. 相似文献
7.
Triple-negative breast cancer (TNBC), which characterized by distinct biological and clinical pathological features, has a worse prognosis because the lack of effective therapeutic targets. Breast MR is the most accurate imaging modality for diagnosis of breast cancer currently. MR imaging recognition could assist in diagnosis, pretreatment planning and prognosis evaluation of TNBC. MR findings of a larger solitary lesion, mass with smooth mass margin, high signal intensity on T2-weighted images and rim enhancement are typical MRI features associated with TNBC. Further work is necessary about the clinical application of dynamic contrast-enhanced MR imaging (DCE-MRI), DWI and MRS. 相似文献
8.
Young Han Lee Daekeon Lim Eunju Kim Sungjun Kim Ho-Taek Song Jin-Suck Suh 《Magnetic resonance imaging》2014
Background and Purpose
Fluid-sensitive MR imaging in postoperative evaluation is important, however, metallic artifacts is inevitable. The purpose is to investigate the feasibility of fat-saturated slice encoding for metal artifact correction (SEMAC)-corrected T2-weighted magnetic resonance (MR) at 3T in patients with spinal prostheses.Methods
Following institutional review board approval, 27 SEMAC-encoded spinal MRs between September 2012 and October 2013 in patients with spinal metallic prostheses were analyzed. The MR images were scanned on a 3T MR system including SEMAC-corrected and uncorrected fast spin echo (FSE) T2-weighted MR images with fat-saturation. Two musculoskeletal radiologists compared the image sets and qualitatively analyzed the images using a five-point scale in terms of artifact reduction around the prosthesis, visualization of the prosthesis and pedicle, and intervertebral neural foramina. Quantitative assessments were performed by calculating the ratio of signal intensity from the fixated vertebra and that from upper level vertebra. For statistical analyses, paired t-test was used.Results
Fat-saturated SEMAC-corrected T2-weighted MR images enabled significantly improved metallic artifact reduction (P < 0.05). Quantitative evaluation of the signal intensity ratio of screw-fixated vertebra and upper level vertebra showed a significantly lower ratio on fat-saturated SEMAC images (P < 0.05), however, the high signal intensity of signal pile-up could be not completely corrected.Conclusion
SEMAC correction in fat-suppressed T2-weighted MR images can overcome the signal loss of metallic artifacts and provide improved delineation of the pedicle screw and peri-prosthetic region. Signal pile-up, however, could not be corrected completely, therefore readers should be cautious in the evaluation of marrow around the prosthesis. 相似文献9.
We introduce the concept of amplifying the transverse magnetic fields produced and/or detected with inductive coils in magnetic resonance settings by using the reversible transverse susceptibility properties of magnetic nanostructures. First, we describe the theoretical formalism of magnetic flux amplification through the coil in the presence of a large perpendicular DC magnetic field (typical of magnetic resonance systems) achieved through the singularity in the reversible transverse susceptibility in anisotropic single domain magnetic nanoparticles. We experimentally demonstrate the concept of transverse magnetic flux amplification in an inductive coil system using oriented nanoparticles with uni-axial magnetic anisotropy. We also propose a composite ferromagnetic/anti-ferromagnetic core/shell nanostructure system with uni-directional magnetic anisotropy that, in principle, provides maximal transverse magnetic flux amplification. 相似文献
10.
High-resolution magnetic resonance imaging using dedicated high-field radiofrequency micro-coils at 16.4 T (700 MHz) was investigated. Specific solenoid coils primarily using silver and copper as conductors with enamel and polyurethane coatings were built to establish which coil configuration produces the best image. Image quality was quantified using signal-to-noise ratio and signal variation over regions of interest. Benchmarking was conducted using 5-mm diameter coils, as this size is comparable to an established coil of the same size. Our 1.4-mm-diameter coils were compared directly to each other, from which we deduce performance as a function of conductor material and coating. A variety of materials and conductor coatings allowed us to choose an optimal design, which we used to image a kidney section at 10-micron resolution. We applied zero-fill extrapolation to achieve 5-micron resolution. 相似文献
11.
MRI techniques have been used to describe velum opening of French vowels. Data based on 18 joined axial slices of 4 mm thickness were recorded with four subjects. Differences in velum opening are calculated from areas measured in the tract between the lowered velum and the back pharynx wall. Results show that for all subjects, the back vowel /
/ has the smallest opening, while some variations are observed for the other vowels. 相似文献
12.
The objective of this study was to examine the feasibility of detecting toxoplasmic brain lesions in a mouse model of cerebral toxoplasmosis by ultrasmall superparamagnetic particles of iron oxide (USPIO)-enhanced magnetic resonance imaging (MRI). Toxoplasmosis encephalitis was induced in Kunming mice by intracerebral injection of Toxoplasma gondii tachyzoites. T2- and T2*-weighted MRI was performed 1, 3, 4, 5 and 6 days after infection before USPIO injection; immediately after USPIO injection; and 24 h later. A comparison of USPIO enhancement and Gd-DTPA enhancement was made in three toxoplasmic mice 4 days after infection. Hematoxylin and eosin staining and Prussian blue staining were performed to detect inflammatory reactions and presence of iron in and around the toxoplasmic brain lesions. Nonenhanced T2-/T2*-weighted imaging detected few abnormalities in the brain up to 5 days. Most mice developed prominent hydrocephalus at 6 days. Gd-DTPA-enhanced imaging showed prominent enhancement of the cerebral ventricles but revealed only few space-occupying lesions in the parenchyma. USPIO-enhanced T2*-weighted imaging showed improved detection of toxoplasmic brain lesions that were invisible to nonenhanced T2-/T2*-weighted imaging and gadolinium-enhanced imaging. Most of the enhancing lesions showed nodular enhancement immediately after USPIO injection, some of which changed appearance 24 h later, having a ring enhancement at the outer rim. It can be concluded that USPIO enhancement of the toxoplasmic lesions may reflect blood–brain barrier impairment and/or inflammatory reactions associated with these lesions. USPIO-enhanced imaging may be used in combination with gadolinium-enhanced imaging to provide better characterization of toxoplasmic brain lesions and, potentially, improve the differential diagnosis of toxoplasmosis encephalitis. 相似文献
13.
Leyong Zeng Wenzhi RenJianjun Zheng Aiguo Wu Ping Cui 《Applied Surface Science》2012,258(7):2570-2575
Water soluble FeOOH nanospindles with small size were synthesized by a simple hydrolysis method of inorganic salts and water bath treatment with different incubation time. The morphology, microstructure, magnetic resonance imaging (MRI) performance and cytotoxicity of the as-prepared FeOOH nanospindles were investigated, respectively. The results showed that the longitudinal length of FeOOH nanospindles was about 40-50 nm, and the incubation time had important effect for the morphology and production rate of FeOOH nanospindles. MRI test showed that the longitudinal and transverse relaxivities (r1 and r2 values) of FeOOH nanospindles were about 3.06 mM−1 s−1 and 5.06 mM−1 s−1, respectively. Furthermore, the experimental results of the Prussian Blue staining showed the clusters of FeOOH nanospindles in the cytoplasm of the labeled cells, and the cytotoxicity characterization indicated that FeOOH nanospindles have low cytotoxicity. Therefore, the as-prepared FeOOH nanospindles will have potential applications as T1- and T2-weighted MRI contrast agents. 相似文献
14.
Annegret Hartung Marcus R. Lisy Karl-Heinz Herrmann Ingrid Hilger Dirk Schüler Claus Lang Matthias E. Bellemann Werner A. Kaiser Jürgen R. Reichenbach 《Journal of magnetism and magnetic materials》2007
This work investigated macrophages labeled with magnetosomes for the possible detection of inflammations by MR molecular imaging. Pure magnetosomes and macrophages containing magnetosomes were analyzed using a clinical 1.5 T MR-scanner. Relaxivities of magnetosomes and relaxation rates of cells containing magnetosomes were determined. Peritonitis was induced in two mice. T1, T2 and T2* weighted images were acquired following injection of the probes. Pure magnetosomes and labeled cells showed slight effects on T1, but strong effects on T2 and T2* images. Labeled macrophages were located with magnetic resonance imaging (MRI) in the colon area, thus demonstrating the feasibility of the proposed approach. 相似文献
15.
16.
Background
Since the advent of magnetic resonance imaging, metal artifacts have posed an important diagnostic problem in different fields of medicine. However, this has not been systematically studied in patients undergoing surgery for brain tumors.Objective
This study was planned to assess whether metal artifacts can occur in patients undergoing brain surgery without metallic implants.Methods
Of 40 individuals who could be included because of having a pre- and postoperative MRI and a postoperative computed tomography (CT) scan or a conventional skull X-ray for the detection of metallic artifacts, 26 patients agreed to participate in this study and gave informed consent.Results
Twenty-six subjects, 12 males and 14 females, with an age range of 12 to 54 years, were included in the study. Four patients were found to have gross metal particles in their postoperative brain CTs and were excluded. Of the remaining 22 subjects, 7 patients (31.8%) had metallic artifacts.Conclusion
Our study showed that simple bone drilling or chiseling during surgical manipulation of skull bones may result in separation of very tiny metal particles which can remain in the surgical site and cause artifacts in postoperative MRIs. This finding appeared to be independent of factors such as age, sex, tumor/incision site, tumor size, pathologic tumor type, total radiation dose, operation–MRI time interval and sequence of MRI. 相似文献17.
Amita Shukla-Dave Nigar Fatma Raja Roy S. Srivastava R.K. Chatterjee V. Govindaraju A.Kasi Viswanathan P. Raghunathan 《Magnetic resonance imaging》1997,15(10):1193-1198
1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid nests in the cervical region. 31P MRS of normal and infected hosts, localized over the same region of interest, show seven major peaks corresponding to phosphomonoesters (including glucose-6-phosphate, fructose-6-phosphate, fructose-1-6-diphosphate, phosphorylcholine, and adenine monophosphate or AMP), inorganic phosphate, glycerophosphorylcholine, phosphoenolpyruvate, phosphocreatine and nucleoside di- and tri-phosphates. Concentrations of phosphomonoesters (PMEs) are higher in the normal rodent compared with the infected ones. In vivo 31P MRS provides a non-invasive assessment of tissue bioenergetics and phospholipid metabolism. 相似文献
18.
The origin of magnetic fields in astrophysical objects is a challenging problem in astrophysics. Throughout the years, many scientists have suggested that non-minimal gravitational-electromagnetic coupling (NMGEC) could be the origin of the ubiquitous astrophysical magnetic fields. We investigate the possible origin of intense magnetic fields by NMGEC near rotating black holes, connected with quasars and gamma-ray bursts. Whereas these intense magnetic fields are difficult to explain astrophysically, we find that they are easily explained by NMGEC. 相似文献
19.
20.
Hong Yang Qiwei Tian Yong Fang Shiping Yang 《Journal of magnetism and magnetic materials》2010,322(8):973-12587
Monodispersed amphiphilic FePt nanoparticles with the diameter of about 4 nm were synthesized by high temperature pyrolysis of iron(III) acetylacetonate and platinum(II) acetylacetonate. Their amphiphilicity is contributed to the tetraethylene glycol (TEG) and oleic acid (OA) on the surface, which is confirmed by FTIR and XPS spectra. They provide a superparamagnetic property with the saturation magnetization (Ms) of about 25 emu/g and the transverse relaxivity (r2) of about 122.6 mM−1 s−1 in aqueous solutions. Furthermore, FePt nanoparticles show low cytotoxicity in living cells. They can be uptaken by HeLa cells effectively and result in the obvious decrease of T2 relaxation time after internalization. 相似文献