首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Concentrations of up to 16 elements have been determined in subcellular fractions of bovine kidney using INAA methods. Levels of Rb and Se have been measured by a cyclic INAA method. A conventional INAA method consisting of 2 irradiations and 3 counting periods has been employed to determine the other elements. Accuracy of measurements has been evaluated by analyzing several standard reference materials. Trace element content of reagents used has been investigated in detail. Fresh samples of bovine kidney have been homogenized in a buffer containing sucrose and HEPES, and the homogeneate separated into nuclei, mitochondrial, lysosomal, microsomal and cytosol fractions by successive differential centrifugation. Concentrations of trace elements have been measured in these fractions using the INAA methods.  相似文献   

2.
Biochemical techniques, including pH variation, outsalting, ultracentrifugation, gel filtration chromatography and electrophoresis, etc., have been employed together with instrumental neutron activation analysis (INAA) to study the rare earth elements (REE) bound proteins in the natural plant fern,Dicranopteris dichitoma. INAA was also used to identify whether the proteins were bound firmly with REE. The results obtained show that two REE bound proteins (RBP-I and RBP-II) have been separated. The molecular weight of RBP-I on Sephadex G-200 gel column is about 8·105 Daltons and that of RBP-II is less than 12,400 Daltons, respectively. However, SDS-PAGE of the two proteins shows that they mainly have two protein subunits with MW 14,100 and 38,700 Daltons. They are probably conjugated proteins, glycoproteins with different glyco-units.  相似文献   

3.
Results obtained for 12 elements in approximately 1600 rocks by instrumental neutron activation analysis (INAA) are compared with those obtained by ICP emission spectrometry (ICP-ES), XRF, and atomic-absorption spectrometry (AAS). Sample duplicates and two controls are used to evaluate the precison of the methods investigated. Application of a method (Maximum Likelihood Functional Relationship) to determine and quantify rotational and translational bias is demonstrated. The elements Na, Fe, Ba, Co, Cr, La, Ni and Rb can be determined in rocks by INAA with sufficient sensitivity and precision, whereas the determination of Ag, Yb, Zn and Zr suffers from inadequate sensitivity. Good agreement is seen in the results for Na (by INAA, ICP-ES and XRF) and AG (INAA and AAS). A significant positive bias (13% or less) is evident in the comparison of results by INAA and ICP-ES or XRF for Cr, Ba, Ni and Fe over a wide range of concentration. A similar trend, though less significant, is observed for the elements Yb, Rb, La and Co; the upper limit of concentration for satisfactory determination is within a decade of the highest detection limit for these elements. Rotational and translational bias is evident for Zn in the comparison of data obtained by INAA and ICP-ES, the results by INAA being appreciably lower above about 400 ppm Zn.  相似文献   

4.
We have used INAA to analyze more than 30 minor and trace elements in 10 human kidney stones (phosphate and oxalate types). In addition we also analyzed human brain tissue samples for trace elements by INAA to determine the limitations of the method. Samples were taken from the temporal and frontal cortex of the brain of a patient that suffered from dialysis encephalopathy (where an increased Al content is expected), as well as a number of control samples. Trace elements were analyzed to study possible compositional differences other than the Al content. The analyses were done using large volume HPGe detectors; because of the low abundances, accuracy and precision vary between 3–80% for individual elements. We found a difference between the rare earth element (REE) patterns for apatite and oxalate kidney stones, and a fractionation compared to typical REE contents in plants. For the brain samples there is evidence for differences between the dialysis patient and the control samples not only for Al, but also for some other elements including the REEs, but most differences are minimal, and may not be significant.  相似文献   

5.
As analytical techniques have become more sensitive, the role of trace elements associated with biological macromolecules has become the subject of many studies in the past twenty years. Many biologically significant macromolecules, such as nucleic acids and proteins, have trace elements essential to their function and structure. Instrumental neutron activation analysis (INAA) contributes useful information in such studies. A procedure combining polyacrylamide gel electrophoresis (PAGE) with INAA and autoradiography has been developed to study biological macromolecules and their associated trace elements. Results from the application of this method to several metalloproteins are presented.  相似文献   

6.
Four kidney stones collected from patients being treated in the Advance Urology Centre of PGIMR, Chandigarh were characterized using instrumental neutron activation analysis (INAA), energy dispersive X-ray fluorescence (EDXRF) and X-ray diffraction (XRD) techniques. For INAA, samples were irradiated in tray rod facility of Dhruva reactor, Mumbai and pneumatic fast transfer system of KAMINI reactor, IGCAR, Kalpakkam. Radioactive assay was carried out using HPGe detector coupled to 8k channel analyzer. Elements determined in the samples by INAA are Zn, Sr, Co, Fe, Cr, Sc, Se, Na and Mn. EDXRF was used for the quantification of Ca. XRD patterns showed that three of the kidney stones are calcium oxalate stone and the other one is uric acid stone. The concentrations of trace elements in general were found to be higher in calcium oxalate stones and positive correlation was observed in the concentrations of Ca with Sr and Zn.  相似文献   

7.
An instrumental neutron activation analysis (INAA) method has been developed for multi-element determination in geological samples. The INAA method consists of irradiation of samples for 90 sec at a flux of 1.0·1012 n·cm−2·sec−1 and determination of 12 elements by using their short-lived nuclides. Samples have been re-irradiated for 3 hrs for measuring concentrations of another 10 elements. Precision and accuracy of the INAA method have been evaluated by analysing samples and USGS standard reference materials. Precision and accuracy are within±15% and ±10%, respectively.  相似文献   

8.
Instrumental Neutron Activation Analysis (INAA) is employed for its important analytical properties. Fundamentally, INAA is a multi-elemental technique allowing the determination of about 40 elements with a good Limit of Detection. In this paper we applied this nuclear technique to study the element composition in PM10 determining about 30 elements.25 filters were collected in downtown Rome from October 1999 to April 2000 and irradiated at the nuclear reactor Triga Mark II (ENEA-Casaccia Laboratories). The γ-ray measurements have allowed the quali- and quantitative analysis. The element levels in PM10 with the relative correlations have been determined: basically, the concentrations are very low.Furthermore, the enrichment factors of all elements will be reported in order to understand the natural or anthropogenic origins of the particulate matter: some elements may be attributed to long-range transport phenomena from other natural and/or anthropogenic sources.  相似文献   

9.
Aiming at the determination of toxic and essential elements in Brazilian commercial bovine milk, 25 ultra high temperature (UHT) milk samples were acquired in the local market of Piracicaba, SP. The samples were freeze-dried and analyzed by instrumental neutron activation analysis (INAA) allowing the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn. When the results were expressed as concentration (mg·l−1) no significant differences were found. However, considering the dry matter, results showed a clear difference between the mass fractions (mg·kg−1 d.w.) of skim milk and whole milk for the elements Br, Ca, K, Na, Rb and Zn, indicating that the removal of fat caused a concentration effect in the dry matter of skim milks. Discrepancies were found between the concentrations of Ca and Na measured by INAA and the values informed in the labels. Ca showed variations within 30% for most samples, while concentrations of Na were up to 190% higher than informed values. The sample preparation and the INAA procedure were appropriate for the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn in milk samples.  相似文献   

10.
Instrumental neutron activation analysis (INAA), and inductively coupled plasma mass spectroscopy (ICP-MS) were applied to the determination of major elements and rare earth elements in Japanese Standard Soil Materials (NDG-1 to -8). Eight major elements, Al, Fe, Ti, Ca, Mg, Mn, K, and Na were determined by INAA. A comparison of the data for rare earth elements obtained by INAA and ICP-MS shows that the data of the contents determined by the two different analytical methods are in fairly good agreement with each other.  相似文献   

11.
As part of the SAFARI-92 biomass buming experiment, aerosol collections were carried out with several size-fractionating sampling devices at a number of sites in Southern Africa. One of the samplers used at all ground-based sites was a stacked filter unit (SFU). The SFU samples were analyzed by both INAA and PIXE analysis. The present paper gives an intercomparison of the analytical results obtained in order to assess the accuracy and to check the quality assurance of the analytical procedures. Twenty-one common elements were determined by both INAA and PIXE. Concentrations of 13 elements (i.e., Na, Mg, Al, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Zn and Br) were generally measured with sufficient precision in both techniques for performing the intercomparison. The INAA and PIXE data were compared in terms of PIXE/INAA concentration ratios on a sample by sample basis for the coarse and fine size fraction separately. the atmospheric concentrations for K, Mn and Fe agreed within 5–10%, the agreement between the data for the other common elements was typically better than 15%. Possible explanations for lower than 1.0 ratios for Cl, Br and Na are presented. The common elements were classified into groups according to their detectability and sensitivity in each technique.  相似文献   

12.
Instrumental neutron activation analysis (INAA) has been applied to the determination of 21 elements in 8 different vegetal samples, to be used as reference materials in 35 European laboratories (CII). Many of these elements hitherto have not been evaluated; they can be useful markers in many environmental problems. The INAA values are compared with CII non-nuclear analytical techniques results. Some rare earths elements (REE) have been also determined and their chondritic ratio versus atomic radius is reported.  相似文献   

13.
Instrumental neutron activation analysis (INAA) and electro-thermal atomic absorption spectrometry (ETAAS) were employed to determine the toxic elements in fourteen fruits harvested in Pakistan. As, Br, Hg, Sb and Se were determined using INAA. Cadmium and Pb were determined using ETAAS. The intake levels of all toxic elements have been calculated. The data show that dates supply the maximum amount of most of the toxic elements. Peels of apple and pear have also been investigated and were found to contain higher concentration of toxic elements than their edible parts. The reliability of the techniques has been established by the use of standard reference materials. This study shows that all investigated fruits cultivated and consumed in Pakistan are safe for human consumption.  相似文献   

14.
Instrumental neutron activation analysis (INAA) and electro-thermal atomic absorption spectrometry (ETAAS) were employed to determine the toxic elements in fourteen fruits harvested in Pakistan. As, Br, Hg, Sb and Se were determined using INAA. Cadmium and Pb were determined using ETAAS. The intake levels of all toxic elements have been calculated. The data show that dates supply the maximum amount of most of the toxic elements. Peels of apple and pear have also been investigated and were found to contain higher concentration of toxic elements than their edible parts. The reliability of the techniques has been established by the use of standard reference materials. This study shows that all investigated fruits cultivated and consumed in Pakistan are safe for human consumption.  相似文献   

15.
Ten feather samples, including primary and secondary flight and tail feathers, were analysed for the trace element composition of vane and rachis structures using instrumental neutron activation analysis (INAA), inductively coupled plasma-mass spectrometry (ICP-MS), and cold vapour atomic absorption spectroscopy (CVAAS). Five environmentally significant elements, Cr, As, Se, Sb and Hg, were analysed by INAA and ICP-MS/CVAAS. A further seventeen elements were analysed by ICP-MS. The majority data obtained by INAA and ICP-MS/CVAAS were not statistically significantly different (p = 0.05), although the removal of isobaric interferences using dynamic reaction cell technology was essential to produce ICP-MS data that were consistent with INAA for Cr, As and Se. Significantly higher trace element concentrations were observed for vane relative to rachis for all elements, except Cu and Hg. These elements displayed vane/rachis ratios of 0.7 ± 0.2 and 1.0 ± 0.2, respectively. In general, vane and rachis subgroups afforded data that were consistent with a normal distribution, with RSDs in the range (12–83) % for INAA analyses. A total of 18 outliers were noted amongst the various feather, structure, element combinations, with 14 outliers being observed in the vane and/or rachis structures of the same tail feather. Given the significant differences in vane and rachis concentrations observed for many elements, the large RSDs reported for elements and the potential for outliers, the determination of environmental trace element burden using feathers is significantly enhanced by the analysis of multiple feathers using INAA.  相似文献   

16.
Results of inter-comparison test organized by the IAEA are analyzed according to the contribution and performance of INAA as non-destructive method for trace elements analysis as compared to other techniques. Several methods were employed for certifying the biological sample (IAEA-0140) and were also compared. It is shown that NAA is the method of a good accuracy and precision. The biological sample has been investigated by INAA based on semi-absolute technique. More than 30 elements have determined without using standards. The reference materials, which are certified in this manner and utilized as primary standard, are also discussed. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

17.
Summary Results for a number of trace elements in a total human diet material (USDIET-1), obtained by the application of both INAA and RNAA are presented. Several dietary reference materials such as NBS SRM 1577A, and BCR CRM Single Cell Protein were also analyzed, and these results are also given. Combining measurements on short and long lived radionuclides, the INAA approach is useful for the determination of about 20 elements. In order to expand the elemental coverage or improve detection limits, RNAA was also explored in two modes: separation of radionuclides using organic ion exchange resins and the use of hydrated manganese dioxide. This combination is applicable to 15 trace elements. For example, using RNAA, the following results were obtained for USDIET-1: Cd=31.8, Mo=280, Cr=71, Ag=4, As=117 and Sb=9.4 g/kg. In the INAA mode, special attention was given to Al, F and Se. The F content of USDIET-1 was found to be 840 mg/kg, a rather high value, resulting from handling USDIET-1 by Teflon tools. By applying INAA and RNAA under two different laboratory conditions, it has been demonstrated that, even for the so-called difficult to determine elements like Cr, As or Mo, consistent results can be obtained. Thus, NAA promises to be a strong tool for human nutritional studies.
Einsatz der Neutronenaktivierung für Nahrungsmittel-Referenzmaterialien
  相似文献   

18.
Results for the content of the rare earth elements (REE), La, Ce, Nd, Sm, Eu, Tb, Yb and Lu in sediments, mussels and fish are presented for an area polluted by REE. The REE are emitted with the process waste water stream from a fertilizer production plant. The method of analysis has been INAA. An attempt to combine the INAA with a simple destruction/preconcentration method is described.  相似文献   

19.
Methods to determine U, Th, and other constituent elements in mineral matrices through Instrumental Neutron Activation Analysis (INAA), have been widely utilized due to their capability to extract a large quantity of information from small samples. In the present work, an experimental methodology based on INAA associated to the cluster statistics technique was used to determine the uranium concentration and its correlation with other elements present in the mineral phosphorites from the northeast region of Brazil. Data for 22 elements including rare-earth elements are presented. A good correlation between uranium and rare-earth elements is observed. For the transition metals, correlation with uranium was not noted.  相似文献   

20.
Analyses for certification have been made for the determination of 30 elements in the National Institute of Standards and Technology (NIST) Tomato Leaves renewal reference material, SRM 1573a. Three of the analytical techniques used were instrumental neutron activation analysis (INAA), radiochemical neutron activation analysis (RNAA), and prompt gamma activation analysis (PGAA). These techniques provided data on 19 elements by INAA, 10 elements by PGAA, and 7 elements by RNAA, with some overlap between techniques. For example, INAA was able to obtain overall analytical uncerainties (at the 95% confidence level) averaging ±2.2% for major and minor constituents (Ca, Mg, K), ±3.3% for constituents from 1 to 1000 g/g (Na, Fe, Al, Mn, Ba, Zn, Rb, La, Cr), and ±6.4% for elements between 10 and 1000 ng/g (Co, V, Se, Th, Sc, Sb), using sample dry weights of approximately 150 mg. These analyses represent the most extensive use to date of nuclear analytical techniques in the certification of a trace element SRM at NIST.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号