首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study reports the analysis of Si in airborne particulate matter by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) as well as X-ray fluorescence (XRF). It was found that Si concentration in airborne particulates collected on PTFE-membrane filters could be accurately determined with a laser beam operated at 160 mJ free running mode, 6.5 mm defocusing distance and 0.8 l/min carrier gas flow rate during the LA-ICP-MS measurement. Standard filters prepared by NIST SRM 1648 urban particulates were used for both XRF and LA-ICP-MS not only to establish the calibration curves of Si, but also to examine the proposed method's effectiveness. The capability of applying both methods for natural sample analysis was also examined. Particulate loaded filter samples collected from a heavily polluted metropolitan area of Kaoshiung, Taiwan were initially measured by XRF, then by LA-ICP-MS. An intercomparison between them was thus performed. As a result, both XRF and LA-ICP-MS proved to be the valid analytical methods for directly determining Si concentrations in airborne particulates on PTFE membrane filters.  相似文献   

2.
A combination of large‐scale and micro‐scale elemental imaging, yielding elemental distribution maps obtained by, respectively non‐invasive macroscopic X‐ray fluorescence (MA‐XRF) and by secondary electron microscopy/energy dispersive X‐ray analysis (SEM‐EDX) and synchrotron radiation‐based micro‐XRF (SR μ‐XRF) imaging was employed to reorient and optimize the conservation strategy of van Eyck's renowned Ghent Altarpiece. By exploiting the penetrative properties of X‐rays together with the elemental specificity offered by XRF, it was possible to visualize the original paint layers by van Eyck hidden below the overpainted surface and to simultaneously assess their condition. The distribution of the high‐energy Pb‐L and Hg‐L emission lines revealed the exact location of hidden paint losses, while Fe‐K maps demonstrated how and where these lacunae were filled‐up using an iron‐containing material. The chemical maps nourished the scholarly debate on the overpaint removal with objective, chemical arguments, leading to the decision to remove all skillfully applied overpaints, hitherto interpreted as work by van Eyck. MA‐XRF was also employed for monitoring the removal of the overpaint during the treatment phase. To gather complementary information on the in‐depth layer build‐up, SEM‐EDX and SR μ‐XRF imaging was used on paint cross sections to record micro‐scale elemental maps.  相似文献   

3.
One of the most often used non-destructive methods for elemental analysis when performing field measurements on bronze sculptures is X-ray fluorescence (XRF) analysis based on portable instrumentation. However, when performing routine in-situ XRF analysis on corroded objects obtained results are sometimes considerably influenced by the corrosion surface products.In this work the suitability of portable XRF for bulk analysis of low corroded bronzes, which were initially precisely characterized using sophisticated and reliable laboratory methods, was investigated and some improvements in measuring technique and data processing were given. Artificially corroded bronze samples were analyzed by a portable XRF instrument using the same methodology and procedures as when performing in-situ analysis on real objects. The samples were first investigated using sophisticated complementary laboratory techniques: Scanning Electron Microscopy, Proton-Induced X-ray Emission Spectroscopy and Rutherford Backscattering Spectrometry, in order to gain precise information on the formation of the corrosion product layers and in-depth elemental profile of corrosion layers for different aging parameters. It has been shown that for corrosion layers of up to ca. 25 μm a portable XRF can yield very accurate quantification results.  相似文献   

4.
罗运柏  何志 《分析化学》1992,20(6):718-720
用X-射线荧光光谱(XRF)法测定了火电厂燃油锅炉受热面的灰渣成分,给出了XRF测试条件,与等离子体发射光谱法的测试结果进行了对比。  相似文献   

5.
Metal contents in polymerization catalysts were comparatively determined by Rutherford backscattering spectrometry (RBS), X-ray photoelectron spectroscopy (XPS) and X-ray fluorescence (XRF) spectroscopy. Catalysts were prepared by grafting metallocene onto bare silica or onto silica chemically modified with methylaluminoxane (MAO). Catalysts were compressed as self-supporting pellets (RBS and XRF), or mounted on adhesive copper tape (XPS). The proximity of the mass of the atomic nuclei did not allow resolution by RBS of the signals corresponding to Zr and Nb, nor Si and Al in catalyst systems such as (nBuCp)2ZrCl2/Cp2NbCl2/MAO/SiO2. On the other hand, Zr, Nb, Si and Al lines were completely resolved in an XRF spectrum. For supported metallocenes on bare silica, XPS measurement was ca. 40% higher than that obtained by RBS. Silica-supported zirconocene showed good agreement in Zr content determination by XRF and RBS.  相似文献   

6.
Blood serum samples were irradiated by monochromatic synchrotron radiation (15 keV) and by 2.4-MeV protons to compare their performance for the detection of trace elements by x-ray fluorescence (XRF) spectrometry. Absolute concentration assignment was based on the addition of an internal standard and on a method which uses the incoherent and coherent radiation as a flux monitor of the incoming beam. Preliminary experiments with a synchrotron XRF microprobe are reported.  相似文献   

7.
X-ray fluorescence (XRF) analysis was successfully applied for the determination of Ca, Cu, Fe, Mn, Ni, Pb, V and Zn on aerosol filters with a diameter of 150 mm. Ambient aerosol was collected on quartz-fibre filters by Digitel high-volume samplers. For XRF analysis three small filter pieces with a diameter of 32 mm were cut out of each filter, considering the radial dependence of elemental distribution on the filter. Elemental concentration decreases by 8–10% from the centre to the outer circle for coarse mode elements. Distribution of fine mode elements display only small radial dependence (2–4%). Results of quantitative analysis by XRF were compared with atomic spectrometric methods (GF-AAS, ICP-OES). The good agreement between the methods confirmed the application of XRF spectrometry for routine analysis of filter samples loaded with ambient aerosol.  相似文献   

8.
X-ray fluorescence (XRF) analysis was successfully applied for the determination of Ca, Cu, Fe, Mn, Ni, Pb, V and Zn on aerosol filters with a diameter of 150 mm. Ambient aerosol was collected on quartz-fibre filters by Digitel high-volume samplers. For XRF analysis three small filter pieces with a diameter of 32 mm were cut out of each filter, considering the radial dependence of elemental distribution on the filter. Elemental concentration decreases by 8-10% from the centre to the outer circle for coarse mode elements. Distribution of fine mode elements display only small radial dependence (2-4%). Results of quantitative analysis by XRF were compared with atomic spectrometric methods (GF-AAS, ICP-OES). The good agreement between the methods confirmed the application of XRF spectrometry for routine analysis of filter samples loaded with ambient aerosol.  相似文献   

9.
The accurate measurement of the maximum possible number of elements in ancient ceramic samples is the main requirement in provenance studies. For this reason neutron activation analysis (NAA) and X-ray fluorescence (XRF) have been successfully used for most of the studies. In this work the analytical performance of inductively coupled plasma-optical-emission spectrometry (ICP-OES) and inductively coupled plasma-mass spectrometry (ICP-MS) has been compared with that of XRF and NAA for the chemical characterization of archaeological pottery. Correlation coefficients between ICP techniques and XRF or NAA data were generally better than 0.90. The reproducibility of data calculated on a sample prepared and analysed independently ten times was approximately 5% for most of the elements. Results from the ICP techniques were finally evaluated for their capacity to identify the same compositional pottery groups as results from XRF and NAA analysis, by use of multivariate statistics.  相似文献   

10.
An analytical procedure for determination of Fe, Ti, V, Ni, Co and Cu, the most important constituents of the polymetallic ore has been developed. Twenty four powdered samples were prepared from the material taken in various places of the ore deposit. The samples were analyzed by wavelength dispersive (WD) and energy dispersive (ED) XRF method. The EDXRF method was applied using radioisotope source as well as a low power X-ray tube (Rh-anode) for excitation of the characteristic K-line radiation of the elements. A Si(Li) detector was used for the detection of radiation. The detection limits and precision of the analytical procedures, using reference materials, were estimated. The accuracy of the different XRF techniques is discussed. The developed analytical procedures based on the XRF method are rapid and quite simple. They can be useful for exploration data accumulation.  相似文献   

11.
In the last decades, in situ non-invasive analytical techniques have been widely used for the analysis of paintings. These techniques are useful to extensively map the surface in a non-invasive way, in order to identify the most representative areas to be sampled. When spectroscopic investigations, such as X ray fluorescence (XRF), are conducted, they usually imply the acquisition of a huge amount of measurements. Subsequently, all these data should be processed in situ, in order to immediately support the sampling strategies. To this aim, an appropriate and fast strategy for multivariate treatment of XRF spectral and hyperspectral data sets is presented, able to account for inter-correlation among variables, which is an issue of high importance for elemental analyses. The main advantage of the approach is that XRF spectral profiles are analysed directly, without computation of derived parameters, by means of principal component analysis (PCA). This procedure allows a fast interpretation of results that can be accomplished in situ. Particular attention was paid to the selection of proper spectral pre-treatments to be applied on data together with the use of several chemometric tools (peak alignment, spectra normalisation and exploratory analysis) aimed at improving the interpretation of XRF results. In addition, the application of multivariate exploratory analysis on XRF hyperspectral maps was studied by using an interactive brushing procedure. The multivariate approach was validated on data obtained from the analysis of the famous Renaissance panel painting “The Ideal City”, exhibited in Palazzo Ducale of Urbino, Italy.  相似文献   

12.
目前实验室对金首饰金含量的主要检测方法为火试金法、X射线荧光光谱(XRF)法和电感耦合等离子体-原子发射光谱(ICP-AES)法.当测试结果出现争议时,国家标准GB 11887-2012中以火试金法作为仲裁方法.采用上述3种不同的金含量测试方法分别对14K、18K和22K饰品的金含量进行测定,并对3种方法检测结果进行比对.结果发现,在3种方法均可满足样品分析对准确度的要求时,以火试金法为基准,XRF法与ICP-AES法对同纯度的金首饰检测结果的相对误差差异较大,XRF法的结果可满足检测要求,而ICP-AES法的结果无法满足检测要求.其中,XRF法的相对误差为0.05%~0.77%,ICP-AES法的相对误差为1.24%~3.89%.从结果来看,低纯度的K金饰品使用XRF法的检测结果要更接近于火试金法.  相似文献   

13.
The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown in recent years its great potential for rapid qualitative analysis of materials. Thanks to the possibility to implement a portable instrument that perform LIBS analysis, this technique is revealed to be particularly useful for in situ analysis in the field of cultural heritages. The purpose of this work is to evaluate the potentiality of LIBS technique in the field of cultural heritages, with respect to the chemical characterization of complex matrix as calcareous and refractory materials for further quantitative analyses on cultural heritages. X-Ray Fluorescence (XRF) analyses were used as reference. Calibration curves of certified materials used as standards were obtained by XRF analyses. The LIBS measurements were performed with a new mobile instrument called Modì (Mobile Double pulse Instrument for LIBS Analysis). The XRF analyses were performed with a portable instrument ArtTAX. LIBS and XRF measurement were performed on both reference materials and samples (bricks and mortars) sampled in the ancient Greek–Roman Theatre of Taormina. Although LIBS measurements performed on reference materials have shown non linear response to concentrations, and so we were not able to obtain quantitative results, an integrated study of XRF and LIBS signals permitted us to distinguish among chemical features and degradation state of measured building materials.  相似文献   

14.
The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown in recent years its great potential for rapid qualitative analysis of materials. Thanks to the possibility to implement a portable instrument that perform LIBS analysis, this technique is revealed to be particularly useful for in situ analysis in the field of cultural heritages. The purpose of this work is to evaluate the potentiality of LIBS technique in the field of cultural heritages, with respect to the chemical characterization of complex matrix as calcareous and refractory materials for further quantitative analyses on cultural heritages. X-Ray Fluorescence (XRF) analyses were used as reference. Calibration curves of certified materials used as standards were obtained by XRF analyses. The LIBS measurements were performed with a new mobile instrument called Modì (Mobile Double pulse Instrument for LIBS Analysis). The XRF analyses were performed with a portable instrument ArtTAX. LIBS and XRF measurement were performed on both reference materials and samples (bricks and mortars) sampled in the ancient Greek–Roman Theatre of Taormina. Although LIBS measurements performed on reference materials have shown non linear response to concentrations, and so we were not able to obtain quantitative results, an integrated study of XRF and LIBS signals permitted us to distinguish among chemical features and degradation state of measured building materials.  相似文献   

15.
Commercial bentonite (BFN) and organoclay (WS35), as well as iron oxide/clay composite (Mag_BFN) and iron/oxide organoclay composite (Mag_S35) were prepared for toluene and naphthalene sorption. Mag_BFN and Mag_S35 were obtained, respectively, by the precipitation of iron oxide hydrates onto sodium BFN and S35 clay particles. The materials were characterized by powder X-ray diffraction (XRD), X-ray Fluorescence (XRF), and TG and DTA. From XRF results and TG data on calcined mass basis, a quantitative method was developed to estimate the iron compound contents of the composites, as well as the organic matter content present in WS35 and Mag_S35.  相似文献   

16.
溶液-粉末压片法XRF分析NdFeB磁性材料的成分   总被引:4,自引:0,他引:4  
结合化学酸溶方法制备样品和使用X射线荧光(XRF)光谱测量试样,建立了NdFeB合金常见主量和痕量杂质元素的快速定量分析方法。同时自制一套参考标样。方法简单。流程短,可以满足准确定量的要求。  相似文献   

17.
用X射线荧光能谱仪对运动鞋黑大底及其白嵌条和红嵌条表面喷霜物质进行采谱分析;其X射线荧光能谱图表明,黑大底及其白嵌条和红嵌条表面喷出物为钙、锌、硅、钛、铁元素的无机化合物和硫黄,这一结果对提高运动鞋大底质量提供了准确可靠的依据。  相似文献   

18.
A conventional X-ray fluorescence (XRF) method as well as total reflection XRF have been applied to the analysis of various environmental materials. Some methodological changes in order to extend the applicability range and improve the accuracy of the XRF analysis are also discussed.  相似文献   

19.
Pitting corrosion of reinforcing steel bar (rebar) imbedded in concrete by chloride ions can cause concrete degradation. It is thus necessary to develop methods to mitigate concrete corrosion which could include using a protective polymer rebar coating. Corrosion studies of polyvinyl butyral-carbon black polymer-coated rebar using soft X-ray fluorescence (XRF) microprobe and micro-X-ray absorption near edge spectroscopy (μ-XANES) are reported in this study. After removal of the polyvinyl butyral-carbon black polymer coating, Fe Lα1, Mn Lα1, and O Kα1 XRF maps were collected as well as Fe and Mn L3-edge μ-XANES spectra from different regions across the whole rebar surface by collection of total electron yield (TEY) and partial XRF yield (PFY) spectra. The distribution of metallic Fe and Fe corrosion products was determined by analysis of the Fe XRF map. The μ-XANES spectra indicated a higher fraction of Fe (III) phases on the corroded rebar surface, while Fe (II/III) phases were the major corrosion products beneath the surface region. In addition, Mn (II) and Mn (III) were determined as the valence states of the manganese corrosion products.  相似文献   

20.
A rapid and simple means for determination of the brass composition and plating weight on brass-plated steel wire and cord is described. The sample preparation procedure is very simple; wires can be mounted as such, and cords can be mounted either as such or as unstranded single wires. The copper content of the brass and the plating weight are determined by measuring the intensities of the different elements by sequential X-ray fluorescence spectrometry (XRF). There is good agreement between the results obtained by XRF and those obtained by differential pulse polarography or spectrophotometry/ complexometry; the precision is even better.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号