首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Although diffusion tensor imaging (DTI) shows great potential for the diagnosis of a variety of pathologies, no consensus for an appropriate assessment standard of DTI exists. This study examined the feasibility of using water-filled arrays of glass capillaries to construct a DTI phantom suitable for making repeated and reproducible measurements required in a quality assessment program. Three phantoms were constructed using arrays of capillaries with three inner diameters (23, 48, and 82 μm). Data were acquired using DTI protocols; the fractional anisotropy (FA), mean apparent diffusion coefficient (ADC) and principal eigenvectors of the diffusion tensors were calculated. This study demonstrated four results: (1) echo-planar images show that susceptibility within the capillary arrays does not lead to substantial differences in precessional frequency in regions containing the arrays and neither do the regions show noticeable image distortion; (2) principal eigenvectors of the diffusion tensors agree to within <10.3° of the array orientations; (3) mean FA values (0.18–0.50) and ADC values (1.40–1.93×10−3 mm2/s) within specified regions of interest are in general agreement with simulations after a simple noise correction; and (4) these array performance characteristics are observable using a typical clinical DTI protocol.  相似文献   

2.
Diffusion tensor imaging (DTI) studies of human ischemic stroke within 24 h of symptom onset have reported variable findings of changes in diffusion anisotropy. Serial DTI within 24 h may clarify these heterogeneous results. We characterized longitudinal changes of diffusion anisotropy by analyzing discrete ischemic white matter (WM) and gray matter (GM) regions during the hyperacute (2.5-7 h) and acute (21.5-29 h) scanning phases of ischemic stroke onset in 13 patients. Mean diffusivity (MD), fractional anisotropy (FA) and T2-weighted signal intensity were measured for deep and subcortical WM and deep and cortical GM areas in lesions outlined by a > or =30% decrease in MD. Average reductions of approximately 40% in relative (r) MD were observed in all four brain regions during both the hyperacute and acute phases post stroke. Overall, 9 of 13 patients within 7 h post symptom onset showed elevated FA in at least one of the four tissues, and within the same cohort, 11 of 13 patients showed reduced FA in at least one of the ischemic WM and GM regions at 21.5-29 h after stroke. The fractional anisotropy in the lesion relative to the contralateral side (rFA, mean+/-S.D.) was significantly elevated in some patients in the deep WM (1.10+/-0.11, n=4), subcortical WM (1.13+/-0.14, n=4), deep GM (1.07+/-0.06, n=1) and cortical GM (1.22+/-0.13, n=5) hyperacutely (< or =7 h); however, reductions of rFA at approximately 24 h post stroke were more consistent (rFA= 0.85+/-0.12).  相似文献   

3.

Background and Purpose

Current approaches to diffusion tensor imaging (DTI) analysis do not permit identification of individual-level changes in DTI indices. We investigated the ability of wild bootstrapping analysis to detect subject-specific changes in brain white matter (WM) before and after sports-related concussion.

Materials and Methods

A prospective cohort study was performed in nine high school athletes engaged in hockey or football and six controls. Subjects underwent DTI pre- and postseason within a 3-month interval. One athlete was diagnosed with concussion (scanned within 72 h), and eight suffered between 26 and 399 subconcussive head blows. Fractional anisotropy (FA) and mean diffusivity (MD) were measured in each WM voxel. Bootstrap samples were generated, and a permuted t test was used to compare voxel-wise FA/MD changes in each subject pre- vs. postseason.

Results

The percentage of WM voxels with significant (p<.05) pre–post FA changes was highest for the concussion subject (3.2%), intermediary for those with subconcussive head blows (mean 1.05%±.15%) and lowest for controls (mean 0.28%±.01%). Similarly, the percentage of WM voxels with significant MD changes was highest for the concussion subject (3.44%), intermediary for those with subconcussive head blows (mean 1.48%±.17%) and lowest for controls (mean 0.48%±.05%). Significantly changed FA and MD voxels colocalized in the concussion subject to the right corona radiata and right inferior longitudinal fasciculus.

Conclusions

Wild bootstrap analysis detected significantly changed WM in a single concussed athlete. Athletes with multiple subconcussive head blows had significant changes in a percentage of their WM that was over three times higher than controls. Efforts to understand the significance of these WM changes and their relationship to head impact forces appear warranted.  相似文献   

4.
The purpose of this study was to determine whether proton magnetic resonance spectroscopy (PMRS) and diffusion tensor imaging (DTI) indices, fractional anisotropy (FA) and mean diffusivity (MD) can be used to distinguish brain abscess from cystic brain tumors, which are difficult to distinguish by conventional magnetic resonance imaging (MRI). Fifty-three patients with intracranial cystic mass lesions and 10 normal controls were studied. Conventional MRI, PMRS and DTI of all the patients were performed on a 1.5-T GE scanner. Forty patients were with brain abscess and 13 with cystic tumors. Cytosolic amino acids (AAs) were present in 32 of 40 brain abscess patients. Out of 13 patients with cystic tumors, lactate and choline were seen in 3 and only lactate was present in 10 patients on PMRS. All 40 cases of abscess had high FA, while all 13 cases of tumor cysts had high MD values. We conclude that FA measurements are more sensitive in predicting the abscess, while PMRS and MD are more specific in differentiating abscess from cystic tumors. We suggest that PMRS should be combined with DTI rather than with diffusion-weighted imaging as FA can be used as an additional parameter for separation of abscess from other cystic intracranial mass lesions.  相似文献   

5.
Although it is known that low signal-to-noise ratio (SNR) can affect tensor metrics, few studies reporting disease or treatment effects on fractional anisotropy (FA) report SNR; the implicit assumption is that SNR is adequate. However, the level at which low SNR causes bias in FA may vary with tissue FA, field strength and analytical methodology. We determined the SNR thresholds at 1.5 T vs. 3 T in regions of white matter (WM) with different FA and compared FA derived using manual region-of-interest (ROI) analysis to tract-based spatial statistics (TBSS), an operator-independent whole-brain analysis tool. Using ROI analysis, SNR thresholds on our hardware-software magnetic resonance platforms were 25 at 1.5 T and 20 at 3 T in the callosal genu (CG), 40 at 1.5 and 3 T in the anterior corona radiata (ACR), and 50 at 1.5 T and 70 at 3 T in the putamen (PUT). Using TBSS, SNR thresholds were 20 at 1.5 T and 3 T in the CG, and 35 at 1.5 T and 40 at 3 T in the ACR. Below these thresholds, the mean FA increased logarithmically, and the standard deviations widened. Achieving bias-free SNR in the PUT required at least nine acquisitions at 1.5 T and six acquisitions at 3 T. In the CG and ACR, bias-free SNR was achieved with at least three acquisitions at 1.5 T and one acquisition at 3 T. Using diffusion tensor imaging (DTI) to study regions of low FA, e.g., basal ganglia, cerebral cortex, and WM in the abnormal brain, SNR should be documented. SNR thresholds below which FA is biased varied with the analytical technique, inherent tissue FA and field strength. Studies using DTI to study WM injury should document that bias-free SNR has been achieved in the region of the brain being studied as part of quality control.  相似文献   

6.
The purpose of this study was to determine correlations among disease progression, diffusion abnormalities in the posterior cingulum and hippocampal volume in patients with Alzheimer's disease (AD). We studied 25 AD patients by neuropsychological testing, including the Mini-Mental State Examination (MMSE), and by magnetic resonance imaging, including diffusion tensor imaging (DTI) and high-resolution three-dimensional T1-weighted imaging. The MMSE score was used as an indicator of disease progression. Diffusion tensor tractography of the posterior cingulum was generated from the DTI; mean diffusivity (MD) and fractional anisotropy (FA) were measured in co-registered voxels along the posterior cingulum. Hippocampal volume was measured using automated voxel-based morphometry. The relationships among MMSE score, hippocampal volume and MD and FA of the posterior cingulum were evaluated by bivariate correlation analysis. MD in the posterior cingulum correlated significantly with the MMSE score. No significant correlation was seen between FA and MMSE score and between hippocampal volume and MMSE score, FA or MD. Our results suggest that MD in the posterior cingulum is a more sensitive indicator of progression of AD than FA of the posterior cingulum and hippocampal volume.  相似文献   

7.
We compare T2-relaxation and diffusion tensor data from normal human brain. The relationships between myelin-water fraction (MWF) and various diffusion tensor measures [e.g., fractional anisotropy (FA), perpendicular diffusivity (ADC perpendicular) and mean diffusivity ] in white matter (WM) and gray matter (GM) structures in the brain were examined in 16 normal volunteers at 1.5 T and 6 normal subjects at 3.0 T and mean diffusivity. We found some degree of linear correlation between these measurements, but by using region of interest (ROI)-based analysis, we also observed several structures which seemed to deviate significantly from a linear relationship. From all investigated relationships between various diffusion tensor measures and myelin-water content, FA and ADC perpendicular yielded the highest correlation coefficients with MWF. However, diffusion anisotropy was also significantly influenced by factors other than myelin-water content. The less operator-dependent voxel-based analysis (VBA) between myelin-water and diffusional anisotropy measures is proposed as an innovative alternative to ROI-based analysis. We confirmed that WM structures, in general, have higher diffusional anisotropy than GM structures and also have higher myelin-water content. However, our findings suggest that in the highly organized fibre arrangement of compact WM structures such as the genu of the corpus callosum, elevated degrees of diffusional anisotropies are measured, which do not necessarily correspond to an elevated myelin content but more likely reflect the highly organized directionality of fibre bundles in these areas (low microscopic and macroscopic tortuosity) as well as strongly restricted diffusion in the interstitial space between the myelinated axons. Conversely, in structures with disorganized fibre bundles and multiple fibre crossings, such as the minor and major forceps, low FA values were measured, which does not necessarily reflect a decrease myelin-water content.  相似文献   

8.
蒋帆  王远军 《波谱学杂志》2018,35(4):520-530
扩散张量脑模板包含丰富的大脑白质组织信息,在空间标准化或者脑图谱创建中具有重要价值,然而基于扩散张量模型构建的脑模板精度不高,特别是在脑部复杂的神经元微观结构区域中应用受到限制.针对这一问题,研究者们提出了基于高分辨率扩散成像构建大脑模板的方法.本文对使用扩散张量成像方法进行脑模板构建的研究进展进行了综述,首先介绍了扩散张量脑模板构建的发展进程,阐述了脑模板构建中解决的技术问题及同时存在的局限性;接着详细论述了基于扩散频谱成像及高角度分辨率扩散成像构建脑模板的不同方法间的差异,并总结了这些研究方法取得的重要进展;最后通过分析目前研究进展提出该研究问题中存在的不足以及未来的发展趋势.  相似文献   

9.
Different fiber materials (hemp, linen, viscose rayon, polyamide and dyneema twine) were tested for their suitability as fiber phantoms for diffusion tensor imaging (DTI) calibration on clinical magnetic resonance imaging systems with common diffusion-weighted echo planar imaging sequences. Additionally, the potential for fiber tracking validation of these fiber phantoms was investigated. For phantom manufacturing the fibers were wound up into a bundle of parallel fibers enwrapped by plastic ribbon. The most homogenously distributed fractional anisotropy (FA) values (0.63 ± 0.10) were determined in the dyneema and polyamide (0.3 ± 0.1) fiber phantom. FA values in the viscose, linen and hemp bundles were at high variations (about 0.2 ± 0.10). The dispersion of the direction of the principal eigenvector in the polyamide and dyneema phantom was less than 7°, for the other fiber phantoms it was over 30°. Thus, the presented results may indicate that polyamide- and dyneema-based fiber phantoms provide the opportunity for verification and validation of DTI sequences on clinical scanner. Additionally, they can be applicable for testing the accuracy of fiber tracking algorithms. A strong parallel alignment of the fibers with a constant compression grade of the fiber bundles could be achieved by machine-made production. This could also provide highly reproducible diffusion properties within the anisotropic fiber phantoms. Authors' address: Kamil A. Il'yasov, Physics Department, Kazan State University, Kremlevskaya ulitsa 18, Kazan 420008, Russian Federation  相似文献   

10.
Keyhole diffusion tensor imaging (keyhole DTI) was previously proposed in cardiac imaging to reconstruct DTI maps from the reduced phase-encoding images. To evaluate the feasibility of keyhole DTI in brain imaging, keyhole and zero-padding DTI algorithms were employed on in vivo mouse brain. The reduced phase-encoding portion, also termed as the sharing rate, was varied from 50% to 90% of the full k-space. Our data showed that zero-padding DTI resulted in decreased fractional anisotropy (FA) and decreased mean apparent diffusion coefficient (mean ADC) in white matter (WM) regions. Keyhole DTI showed a better edge preservation on mean ADC maps but not on FA maps as compared to the zero-padding DTI. When increasing the sharing rate in keyhole approach, an underestimation of FA and an over- or underestimation of mean ADC were measured in WM depending on the selected reference image. The inconsistency of keyhole DTI may add a challenge for the wide use of this modality. However, with a carefully selected directive diffusion-weighted image to serve as the reference image in the keyhole approach, this study demonstrated that one may obtain DTI indices of reduced-encoding images with high consistency to those derived with full k-space DTI.  相似文献   

11.
In vivo diffusion tensor imaging (DTI) of rat cervical and thoracic spinal cord was performed using a three-element phased array coil at 7 T. The magnetic field was shimmed over the spinal cord in real time using an in-house developed automatic algorithm. Echo planar imaging (EPI)-based diffusion-weighted images (DWIs) were acquired with 21 gradient encoding directions. The DWIs were tensor encoded, and diffusion tensor metrics, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ0) and transverse diffusivity (λ) were determined for both white matter (WM) and gray matter (GM). The results on six normal rats indicated no significant differences in the diffusion tensor metrics between thoracic and cervical regions. However, the DTI-derived metrics in cervical spinal cord from our study are somewhat different from the published results in rats. The possible reasons for these differences are suggested.  相似文献   

12.
Rapid maturational brain changes occur during adolescence--a time associated with risk-taking behaviors and improvements in cognition. The present study examined the relationship between white matter (WM) microstructure, impulsive behavior and response inhibition in female and male adolescents. Twenty-one healthy adolescents underwent diffusion tensor imaging using a 3.0-T magnetic resonance imaging system. Impulse control was assessed using the Bar-On Emotional Quotient Inventory, Youth Version. Response inhibition was assessed using the Stroop Color-Word Interference Test. Fractional anisotropy (FA), a measure of WM coherence, and trace, a measure of overall diffusivity, were determined from voxels manually placed in the midline and in the left and right forward-projecting arms of the genu and the splenium of the corpus callosum. Sex-specific differences were observed for the relationship between FA and impulsive behavior in the right anterior callosum for males and in the splenium for females. Males, compared to females, displayed significantly higher FA in the left WM region. Although trace was not associated with impulse control, trace in the genu (for females) and splenium (males and females) was associated with Stroop performance. Regional differences in trace also were evident, with lower values in the splenium observed than in all other regions. Although the latter significantly improved with age, no sex differences in impulse control or in Stroop performance were detected. The present findings provide supporting evidence for sex-related differences in the development of WM microstructure during adolescence. These data further suggest a neurobiological mechanism underlying some of the emotional and cognitive changes commonly observed in males versus females during the adolescent period.  相似文献   

13.
Recent studies have demonstrated regional segregations on several peripheral white matter (WM) regions, which may imply different anatomical or functional characteristics [Cereb Cortex 17(4) 2007 816–25; Neuroimage 37(2) 2007 599–610; J Cogn Neurosci 16(7) 2004 1227–33]. Nonetheless, little is known about overall patterns of peripheral WM across the regions. In this study, diffusion tensor imaging with 2-mm isovoxel resolution and cortical surface mapping were combined to determine peripheral WM structure. Fractional anisotropy (FA) mapping showed consistent regional patterns across the young normal subjects while significant high or low FA values were shown in the motor-somatosensory cortex, prefrontal cortex, temporal, and medial occipital cortex. By adopting both region of interest and connectivity analysis, results were then discussed with structural network properties as well as WM maturation process.  相似文献   

14.
Diffusion tensor imaging (DTI) of in-vivo human brain provides insights into white matter anatomical connectivity, but little is known about measurement difference biases and reliability of data obtained with last generation high field scanners (> 3 T) as function of MRI acquisition and analyses variables. Here we assess the impact of acquisition (voxel size: 1.8 × 1.8 × 1.8, 2 × 2 × 2 and 2.5 × 2.5 × 2.5 mm3, b-value: 700, 1000 and 1300 s/mm2) and analysis variables (within-session averaging and co-registration methods) on biases and test-retest reproducibility of some common tensor derived quantities like fractional anisotropy (FA), mean diffusivity (MD), axial and radial diffusivity in a group of healthy subjects at 4 T in three regions: arcuate fasciculus, corpus callosum and cingulum. Averaging effects are also evaluated on a full-brain voxel based approach. The main results are: i) group FA and MD reproducibility errors across scan sessions are on average double of those found in within-session repetitions (≈ 1.3 %), regardless of acquisition protocol and region; ii) within-session averaging of two DTI acquisitions does not improve reproducibility of any of the quantities across sessions at the group level, regardless of acquisition protocol; iii) increasing voxel size biased MD, axial and radial diffusivities to higher values and FA to lower values; iv) increasing b-value biased all quantities to lower values, axial diffusivity showing the strongest effects; v) the two co-registration methods evaluated gave similar bias and reproducibility results. Altogether these results show that reproducibility of FA and MD is comparable to that found at lower fields, not significantly dependent on pre-processing and acquisition protocol manipulations, but that the specific choice of acquisition parameters can significantly bias the group measures of FA, MD, axial and radial diffusivities.  相似文献   

15.
The recently presented B-matrix Spatial Distribution (BSD) approach is a calibration technique which derives the actual distribution of the B-matrix in space. It is claimed that taking into account the spatial variability of the B-matrix improves the accuracy of diffusion tensor imaging (DTI). The purpose of this study is to verify this approach theoretically through computer simulations.Assuming three different spatial distributions of the B-matrix, diffusion weighted signals were calculated for the six orientations of a model anisotropic phantom. Subsequently two variants of the BSD calibration were performed for each of the three cases; one with the assumption of high uniformity of the model phantom (uBSD-DTI) and the other taking into account imperfections in phantom structure (BSD-DTI). Several cases of varying degrees of phantom uniformity were analyzed and the distributions of the B-matrix obtained were used for the calculation of the diffusion tensor of a model isotropic phantom. The results were compared with standard diffusion tensor calculation.The simulations confirmed the improvement of accuracy in the determination of the diffusion tensor after the calibration. BSD-DTI improves accuracy independent of both the degree of uniformity of the phantom and the inhomogeneity of the B-matrix. In cases of a relatively good uniformity of the phantom and minor distortions in the spatial distribution of the B-matrix, the uBSD-DTI approach is sufficient.  相似文献   

16.
PURPOSE: The purpose of this study was to determine a suitable registration algorithm for diffusion tensor imaging (DTI) using conventional preprocessing tools [statistical parametric mapping (SPM) and automated image registration (AIR)] and to investigate how anisotropic indices for clinical assessments are affected by these distortion corrections. MATERIALS AND METHODS: Brain DTI data from 15 normal healthy volunteers were used to evaluate four spatial registration schemes within subjects to correct image distortions: noncorrection, SPM-based affine registration, AIR-based affine registration and AIR-based nonlinear polynomial warping. The performance of each distortion correction was assessed using: (a) quantitative parameters: tensor-fitting error (Ef), mean dispersion index (MDI), mean fractional anisotropy (MFA) and mean variance (MV) within 11 regions of interest (ROI) defined from homogeneous fiber bundles; and (b) fiber tractography through the uncinate fasciculus and the corpus callosum. Fractional anisotropy (FA) and mean diffusivity (MD) were calculated to demonstrate the effects of distortion correction. Repeated-measures analysis of variance was used to investigate differences among the four registration paradigms. RESULTS: AIR-based nonlinear registration showed the best performance for reducing image distortions with respect to smaller Ef (P<.02), MDI (P<.01) and MV (P<.01) with larger MFA (P<.01). FA was decreased to correct distortions (P<.0001) whether the applied registration was linear or nonlinear and was lowest after nonlinear correction (P<.001). No significant differences were found in MD. CONCLUSION: In conventional DTI processing, anisotropic indices of FA can be misestimated by noncorrection or inappropriate distortion correction, which leads to an erroneous increase in FA. AIR-based nonlinear distortion correction would be required for a more accurate measurement of this diffusion parameter.  相似文献   

17.
The objective of this study is to determine differential diagnostic value of diffusion tensor imaging (DTI) in high-grade brain astrocytomas, brain solitary metastases and brain abscesses. 53 patients with cerebral solitary lesions which showed ring enhancement on contrast-enhanced T 1-weighted images were enrolled in this study. Brain tissues were examined pathologically from 49 patients to confirm the cerebral occupational diseases. Four patients have been diagnosed with primary cancer plus brain solitary metastasis. DTI measurements were obtained from regions of interest placed on central cavity, white matter of the immediate peritumoral region (IPR) and cerebral white matter of the normal side. The cavity of high-grade astrocytoma and brain metastases displayed hypointense signals; most of the brain abscess cavities displayed high signal intensity except for one case with uneven signal intensity. Mean diffusivity (MD) and fractional anisotropy (FA) values could be used for differentiation between tumor and abscess in brain. The brain abscess cavities showed restricted diffusion and anisotropy [MD = (0.604 ± 0.13) × 10−3 mm2/s, FA = 0.185 ± 0.03], whereas the central portion of high-grade astrocytoma [MD = (2.76 ± 0.26) × 10−3 mm2/s, FA = 0.069 ± 0.02] and solitary brain metastases [MD = (2.82 ± 0.29) × 10−3 mm2/s, FA = 0.064 ± 0.02] showed unrestricted diffusion and isotropy. Brain abscess could be differentiated by MD and FA values in their cavities from brain tumors (P < 0.01). The IPRs were all depicted as hyperintense or isointense signals on diffusion-weighted imaging. The difference between FA values in the IPR of high-grade brain astrocytomas and other groups was statistically significant (P < 0.01). In conclusion, our results suggested the potential role of the cavity MD and FA values in the differential diagnoses of brain tumors and brain abscesses; meanwhile, high-grade astrocytomas could be distinguished from solitary metastases and abscesses by evaluating their corresponding FA values in the IPR on brain magnetic resonance imaging (MRI). Combined with conventional MRI, DTI may help radiologists to facilitate the differential diagnosis of ring-enhancing cerebral lesions in clinical practice.  相似文献   

18.
In this work, we propose a variable FA method that combines in vivo flip angle (FA) calibration and correction with a short TR variable FA approach for a fast and accurate T(1) mapping. The precision T(1)s measured across a uniform milk phantom is estimated to be 2.65% using the conventional (slow) inversion recovery (IR) method and 28.5% for the variable FA method without FA correction, and 2.2% when FA correction is included. These results demonstrate that the sensitivity of the variable FA method to RF nonuniformities can be dramatically reduced when these nonuniformities are directly measured and corrected. The acquisition time for this approach decreases to 10 min from 85 min for the conventional IR method. In addition, we report that the averaged T(1)s measured from five normal subjects are 900 +/- 3 ms, 1337 +/- 8 ms and 2180 +/- 25 ms in white matter (WM), gray matter (GM) and cerebral spinal fluid (CSF) using the variable flip angle method with FA correction at 3 T, respectively. These results are consistent with previously reported values obtained with much longer acquisition times. The method reduces the total scan time for whole brain T(1) mapping, including FA measurement and calibration, to approximately 6 min. The novelty of this method lies in the in vivo calibration and the correction of the FAs, thereby allowing a rapid and accurate T(1) mapping at high field for many applications.  相似文献   

19.
This study investigated the effects on the measurement of fractional anisotropy (FA) during interpolation of diffusion tensor images in spatial normalization, which is required for voxel-based statistics. Diffusion tensor imaging data were obtained from nine male patients with attention deficit/hyperactivity disorder and nine age-matched control subjects. Regions of interest were selected from the genu of corpus callosum (GCC) and the right anterior corona radiata (RACR), with FA values measured before and after spatial normalization using two interpolation algorithms: linear and rotationally linear. Computer simulations were performed to verify the experimental findings. Between-group difference in FA was observed in the GCC and RACR before spatial normalization (P<.00001). Interpolation reduced the measured FA values significantly (P<.00001 for both algorithms) but did not affect the group difference in the GCC. For the RACR, the between-group difference vanished (P=.968) after linear interpolation but was relatively unaffected by using rotationally linear interpolation (P=.00001). FA histogram analysis and computer simulations confirmed these findings. This work suggests that caution should be exercised in voxel-based group comparisons as spatial normalization may affect the FA value in nonnegligible degrees, particularly in brain areas with predominantly crossing fibers.  相似文献   

20.
In this work, we have evaluated the performance of a diffusion-sensitive fast spin-echo (FSE) pulse sequence. The proposed pulse sequence utilises velocity-compensating diffusion-encoding gradients and includes the collection of navigator echoes. Spoiler gradients were inserted in the slice-selecting direction to minimise effects from stimulated echoes. Calculations of the b values showed that cross-terms between imaging gradients and diffusion gradients only led to a marginal increase of b values. Pixel-wise calculation of apparent diffusion coefficient (ADC) maps was performed numerically, considering cross-terms between diffusion-encoding and imaging gradients. The sequences investigated used echo train lengths of 16, 8 and 4 echoes and were encoded in either the slice-, frequency- or phase-encoding direction. In order to allow for higher b values a pulse-sequence version using non-motion compensating diffusion-encoding gradients was written. Phantom measurements were performed and the diffusion coefficients of water and acetone were reasonable. Seven healthy volunteers (age 28–50 years) were examined and apparent diffusion coefficient values agreed well with expected values. Diffusion-weighted images, apparent diffusion coefficient maps and images corresponding to the trace of the diffusion tensor of good quality were retrieved in vivo.  相似文献   