首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for the determination of GDC‐0425 concentrations in human plasma has been developed and validated. Supported liquid extraction was used to extract plasma samples (50 μL) and the resulting samples were analyzed using reverse‐phase chromatography and mass spectrometry coupled with a turbo‐ionspray interface. The mass analysis of GDC‐0425 was performed using multiple reaction monitoring transitions in positive ionization mode. The method was validated over the calibration curve range of 1.00–1000 ng/mL using linear regression and 1/x2 weighting. Within‐run relative standard deviation ranged from 0.8 to 5.1%, while between‐run RSD varied from 1.9 to 4.7% for QCs. The accuracy ranged from 90.0 to 101.0% of nominal for within‐run and from 94.0 to 100.0% of nominal for between‐run. Overall extraction recovery was 87.4% for GDC‐0425 and 87.9% for GDC‐0425‐d9. Stability of GDC‐0425 was established in human plasma for 374 days at ?20 and ?70 °C and established in reconstituted sample extracts for 88 h when stored at 2–8 °C. Stable‐labeled internal standard was used to minimize matrix effects. This assay was used to characterize the pharmacokinetics of GDC‐0425 in cancer patients.  相似文献   

2.
A sensitive and reliable procedure for the simultaneous determination of simvastatin (SV) and its active beta-hydroxy acid metabolite (SVA) in human plasma was developed and validated. The analytes were extracted simultaneously from 0.5 ml aliquots of human plasma samples by methyl tert-butyl ether (MTBE) via Chem Elut cartridge extraction [also called liquid-solid extraction (LSE) or liquid-liquid cartridge extraction (LLCE)], separated through a Kromasil C(18) column (50 x 2 mm i.d. 5 microm) and detected by tandem mass spectrometry with a turbo ionspray interface. Stable isotope-labeled SV and SVA, (13)CD(3)-SV and (13)CD(3)-SVA, were used as internal standards. SV and SVA were detected in positive and negative ion modes, respectively, via within-run polarity switching. The use of Chem Elut cartridges not only provided a simple and efficient means of plasma sample extraction but also successfully reduced the interconversion between SV and SVA to an undetectable (for lactonization of SVA) or negligible (<0.07%, for hydrolysis of SV) level. The method showed excellent reproducibility, with intra- and inter-assay precisions <4.5% (RSD), and intra- and inter-assay accuracy between 94% and 107% of nominal values, for both analytes. The extraction recoveries were 78% and 87% on average for SV and SVA, respectively. The analyte was found to be stable in plasma through three freeze (-70 degrees C)-thaw (4 degrees C) cycles and for at least 3 h under bench-top storage condition in an ice-bath (4 degrees C), and also in the reconstitution solution at 4 degrees C for at least 24 h. The method has a lower limit of quantitation (LOQ) of 50 pg ml(-1) with a linear calibration range of 0.05-50 ng ml(-1) for both analytes, and has proved to be very reliable for the analysis of clinical samples.  相似文献   

3.
We investigated the application of alkylamines, as additives to the mobile phase, to a quantification method for the metabolites, M-III and M-IV, of TAK-778, which is a new bone anabolic agent, in human serum using liquid chromatography/tandem mass spectrometry (LC/MS/MS). Prior to setting up the analytical method, we found that 1-alkylamines co-existing with M-III and M-IV in the turbo ionsprayed solution formed 1-alkylammonium adduct molecules of these metabolites during the ionization process, and the abundance of the adduct ions was considerably higher than that of protonated molecules ([M + H](+)s) of these metabolites. Based on these findings, we investigated a variety of 1-alkylamines and their spiked concentrations in the mobile phase for LC/MS/MS analysis to obtain higher sensitivities for the quantification of these metabolites. After these examinations, we found that 1-hexylamine at a final concentration of 0.05 mmol l(-1) was the most suitable additive for the mobile phase, and set the selected reaction monitoring (SRM) ions for the 1-hexylammonium adduct molecule and [M + H](+), allowing about a fivefold gain in the SRM chromatographic peak compared with that without 1-hexylamine. The adduct ion was considered to be formed by interaction between the amino group of 1-hexylamine and the phosphoryl group of M-III and M-IV. The internal standard (I.S.) used was deuterated M-III for each metabolite. The analytes and I.S. were extracted with diethyl ether from serum samples at neutral pH and injected into the LC/MS/MS system with a turbo ionspray interface. The limit of quantification for both analytes was 0.5 ng ml(-1) when 0.1 ml of serum was used, and the calibration curves were linear in the range 0.5-100 ng ml(-1). The method was precise; the intra- and inter-day precisions of the method were not more than 5.6%. The accuracy of the method was good, with deviations between added and calculated concentrations of M-III and M-IV being typically within 16.6%. This method provided reliable pharmacokinetic data for M-III and M-IV after the intramuscular administration of TAK-778 sustained-release formulation in humans.  相似文献   

4.
A sensitive and rapid liquid chromatography/electrospray ion trap mass spectrometry (LC/MS/MS) method has been developed for the quantitative determination of medroxyprogesterone acetate (MPA) in human plasma. Plasma samples (1.0 mL) were simply extracted with pentane and the extracts were analyzed by HPLC with the detection of the analyte in the selective reaction monitoring (SRM) mode. The determination of MPA was accurate and reproducible, with a limit of quantitation of 0.05 ng/mL in plasma. The standard calibration curve for MPA was linear (r = 0.998) over the concentration range 0.05-6.0 ng/mL in human plasma. Analysis precision over the concentration range of MPA was lower than 18.8% (relative standard deviation, RSD) and accuracy was between 96.2 and 108.7%.  相似文献   

5.
An improved assay for the determination of rofecoxib in human plasma samples is described. The analyte and an internal standard were extracted from the plasma matrix using solid-phase extraction in the 96-well format with an Empore C8-SD extraction plate. The analytes are chromatographed on a Waters Symmetry C18 analytical column (3.5 microm, 50x4.6 mm) with a mobile phase consisting of acetonitrile-water (35:65, v/v). Analyte detection was via fluorescence following post-column photochemical derivatization. Eight point calibration curves over the concentration range of 0.5-80 ng/ml yielded a linear response when a 1/y weighted linear regression model was employed. Based on the replicate analyses (n=5) of spiked standards, the within-day assay precision was better than 8% RSD at all points on the calibration curve, within-day accuracy was within 6% of nominal at all standard concentrations. The between-run precision and accuracy of the assay, as calculated from the results of the analysis of quality control samples, was better than 7% RSD and within 5% of nominal. Assay throughput was improved by a factor of three as compared to previously described methods. The method was partially automated using a combination of a Packard Multi-Probe liquid handling system and a TomTec Quadra 96 workstation.  相似文献   

6.
Triapine is an inhibitor of ribonucleotide reductase (RNR). Studies have shown that triapine significantly decreases the activity of RNR and enhanced the radiation‐mediated cytotoxicity in cervical and colon cancer. In this work, we have developed and validated a selective and sensitive LC‐MS/MS method for the determination of triapine in human plasma. In this method, 2‐[(3‐fluoro‐2‐pyridinyl)methylene] hydrazinecarbothioamide (NSC 266749) was used as the internal standard (IS); plasma samples were prepared by deproteinization with acetonitrile; tripaine and the IS were separated on a Waters Xbridge Shield RP18 column (3.5 µm; 2.1 × 50 mm) using a mobile phase containing 25.0% methanol and 75.0% ammonium bicarbonate buffer (10.0 mm , pH 8.50; v/v); column eluate was monitored by positive turbo‐ionspray tandem mass spectrometry; and quantitation of triapine was carried out in multiple‐reaction‐monitoring mode. The method developed had a linear calibration range of 0.250–50.0 ng/mL with correlation coefficient of 0.999 for triapine in human plasma. The IS‐normalized recovery and the IS‐normalized matrix factor of triapine were 101–104% and 0.89–1.05, respectively. The accuracy expressed as percentage error and precision expressed as coefficient of variation were ≤±6 and ≤8%, respectively. The validated LC‐MS/MS method was applied to the measurement of triapine in patient samples from a phase I clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
This paper describes the development and partial validation of a fast, sensitive and specific ultra-performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method for the determination of testosterone (T) and its four metabolites, 6beta-OH-T, 16alpha-OH-T, 16beta-OH-T and 2alpha-OH-T, in in vitro samples. The analytical method involves direct dilution of samples with acetonitrile containing an internal standard, followed by separation of testosterone and the four metabolites on an Acquity UPLCtrade mark C(18) column and detected by selected reaction monitoring (SRM) in positive ionization mode using turbo ionspray ionization. The parent compound and its metabolites investigated were well separated (Rs >1.5) with a run time of 4 min under a gradient condition. The method was partially validated. The linear concentration range was 0.01 to 5 microM for all the compounds of interest. Inter-assay mean bias and relative standard deviation (RSD) were in the range of -12% to 8% and 4.1% to 8.5%, respectively. Intra-assay mean bias and RSD were in the range of -8.0% to 5.2% and 3.4% to 9.6%, respectively. The lower limit of quantitation for this assay was 0.01 microM. The differences in LC/MS performance were investigated by conducting a comparison of UPLC with another method previously optimized for HPLC-based separation and quantification of testosterone and its metabolites.  相似文献   

8.
A rapid, sensitive and robust assay procedure using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the determination of famotidine in human plasma and urine is described. Famotidine and the internal standard were isolated from plasma samples by cation-exchange solid-phase extraction with benzenesulfonic acid (SCX) cartridges. The urine assay used direct injection of a diluted urine sample. The chromatographic separation was accomplished by using a BDS Hypersil silica column with a mobile phase of acetonitrile-water containing trifluoroacetic acid. The MS/MS detection of the analytes was set in the positive ionization mode using electrospray ionization for sample introduction. The analyte and internal standard precursor-product ion combinations were monitored in the multiple-reaction monitoring mode. Assay calibration curves were linear in the concentration range 0.5--500 ng ml(-1) and 0.05--50 microg ml(-1) in plasma and urine, respectively. For the plasma assay, a 100 microl sample aliquot was subjected to extraction. To perform the urine assay, a 50 microl sample aliquot was used. The intra-day relative standard deviations at all concentration levels were <10%. The inter-day consistency was assessed by running quality control samples during each daily run. The limit of quantification was 0.5 ng ml(-1) in plasma and 0.05 microg ml(-1) in urine. The methods were utilized to support clinical pharmacokinetic studies in infants aged 0-12 months.  相似文献   

9.
A sensitive, rapid and specific quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of apomorphine (APO) in canine plasma. The analytes were prepared using one-step liquid-liquid extraction, and analyzed on a Waters Symmetry C(18) column interfaced with triple quadrupole tandem mass spectrometer. A mixture of methanol/0.1% formic acid in water (70: 30, v/v) was employed as the isocratic mobile phase. Positive electrospray ionization was utilized as the ionization source. The analyte and clenbuterol (internal standard) were both detected using multiple reaction monitoring (MRM) mode. The limit of detection (LOD) obtained was 0.03 ng/mL. The assay was linear over the concentration range of 0.1-100 ng/mL, and provided good precision (RSD) and good accuracy (RE). The analyte was stable by using antioxidants throughout the whole study. The experimental results show that LC/MS/MS is a rapid and sensitive method to analyze APO in plasma. Finally, the proposed method was successfully applied to a pharmacokinetic study of APO after intranasal administration of 0.5 mg apomorphine to 10 healthy beagle dogs.  相似文献   

10.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine gliclazide and metformin in human plasma using huperzine A as the internal standard (IS). After acetonitrile-induced protein precipitation of the plasma samples, gliclazide, metformin and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of 2.0 min and linear calibration curves over the concentration ranges of 10-10,000 ng ml(-1) for gliclazide and 7.8-4678.9 ng ml(-1) for metformin. The recoveries of the method were found to be 71-104%. The lower limits of quantification (LOQ) of the method were 10.0 and 7.8 ng ml(-1) for gliclazide and metformin, respectively. The intra- and interday precision was less than 15% for all quality control samples at concentrations of 100, 500, and 2000 ng ml(-1). The validated LC/MS/MS method has been used to study bioequivalence in healthy volunteers. These results indicate that the method was efficient with a very short running time (2.0 min) for metformin and gliclazide compared to the methods reported in the literature. The presented method had acceptable accuracy, precision and sensitivity and was used in clinical bioequivalence study.  相似文献   

11.
Isoniazid and ethambutol are commonly used in various combination treatments for tuberculosis, and for this reason a rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous quantification of these two drugs in human plasma. After a simple protein precipitation using methanol, the analytes and the internal standard metformin were chromatographed on a C18 column and detected by MS/MS. An atmospheric pressure chemical ionization interface was chosen to reduce ion suppression from sample matrix components and provide high sensitivity. The LC retention times for isoniazid and ethambutol were 2.46 and 2.27 min, respectively. The method was linear in the concentration range of 10.0-5000 ng/mL for each analyte using 100 microL plasma. The intra- and inter-day precisions, expressed as the relative standard deviation (RSD), were less than 5.7 and 6.4%, determined from QC samples for isoniazid and ethambutol, and the accuracies were within +/-2.1% and +/-4.5% in terms of relative error, respectively. The method was successfully employed in a pharmacokinetic study after oral administration of a multicomponent formulation containing 150 mg isoniazid, 500 mg ethambutol, 150 mg rifampicin and 250 mg pyrazinamide.  相似文献   

12.
Automated chip-based infusion nanoelectrospray ionization coupled to tandem mass spectrometry (nanoESI-MS/MS) was used to validate a bioanalytical assay conforming to United States Food and Drug Administration (FDA) regulatory guidelines and Good Laboratory Practices (GLP). Reboxetine was used as the analyte fortified in dog plasma along with an analog internal standard (IS). The best nanoESI response for reboxetine was observed with 90% acetonitrile (ACN)/water without any mobile phase modifiers. The analyte and IS were extracted from dog plasma samples by liquid-liquid extraction (LLE). The supernatant was concentrated to dryness and redissolved in 90% ACN/water for nanoESI. Selected reaction monitoring (SRM) data were collected for all samples to generate ion current profiles with a base width of approximately 20 s. Selectivity experiments showed no interferences in blank plasma samples. Interferences as a result of in-source collision-induced dissociation of metabolites were not an issue due to the previously documented metabolism of reboxetine. Matrix suppression was evaluated across multiple lots of dog plasma as well as over different animal species (rabbit, rat, mouse) and different anticoagulants (heparin, EDTA). Matrix suppression ranged from approximately 30-60% across the different lots, species etc.; however, in all instances, the analyte and the IS were suppressed by similar amounts, suggesting the similarity in ionization properties between the two. A three-batch validation was performed (each batch consisting of four different concentrations, six replicates of each concentration) and demonstrated inter-assay accuracy (% relative error; RE) of less than +/-8% and an inter-assay precision (% relative standard deviation; RSD) of less than 7%, thus meeting regulatory guidelines. A comparison of analyses by nanoESI-MS/MS and liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) showed that nanoESI-MS/MS had a greater slope for the calibration standard curve compared to LC/MS/MS, indicating greater sensitivity for the former technique. It is also noteworthy that the amount of sample infused during nanoESI-MS/MS was approximately 80-fold less compared to the amount of sample injected during LC/MS/MS. The absence of carryover (attributed to the lack of a common fluid path) in the nanoESI technique enabled the extension of the assay linear dynamic range to 500,000-fold, and the possibility of analyzing samples in a single batch without the need for re-analysis of samples with high concentrations. This technology offers the possibility for increased throughput for studies supporting drug development by providing fast data turnaround for assays conforming to regulatory guidelines and GLPs.  相似文献   

13.
A liquid chromatography (LC) method with UV detection is reported for the determination of the sulfonamide herbicide flumetsulam in soybeans. The ground soybean sample was partitioned between methanol and hexane. The hexane removed the lipids, and the methanol layer containing the analyte was further partitioned between dichloromethane and aqueous phosphate buffer at pH 7.0. The aqueous layer, containing the analyte, was acidified to pH 2.2 and partitioned with fresh dichloromethane. The dichloromethane layer containing the analyte was evaporated, and the residue was dissolved in the LC mobile phase for analysis. A polar embedded C18 column was used with a mobile phase of pH 2.2 aqueous phosphate buffer-acetonitrile (68 + 32), run isocratically with detection at 225 nm. The average recovery was 82% with a relative standard deviation (RSD) of 10%. A coefficient of determination of R2 = 0.9992 was achieved for the analyte calibration curve, from 0.005 to 1 microg/mL. The limit of detection, determined from 3 times the standard deviation of 7 replicate extractions of the lowest fortification level (0.01 microg/g), was 0.005 microg/g with an RSD of 22%. LC/electrospray ionization/mass spectrometry in the positive-ion mode was used for identity confirmation of flumetsulam in the fortified soybean extract. The ions at m/z 326, 348, and 129 were observed.  相似文献   

14.
A simple, sensitive, and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method, using electrospray ionization, was developed and validated to quantify trimetazidine in human plasma using propranolol hydrochloride as an internal standard (IS). Samples were prepared by solid-phase extraction and analyzed without drying and reconstitution. The analyte and IS were chromatographed on a C18 reversed-phase column under isocratic conditions using 2 mM ammonium acetate (pH 3.5)-acetonitrile (40 + 60, v/v) as the mobile phase with a run time of 2.0 min. Quantitation was done on a triple-quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring mode to detect parent --> product ion (m/z 267.2 --> 181.4) transition. The method was validated for sensitivity, accuracy and precision, linearity, recovery, matrix effect, and stability. Linearity in plasma was observed over the concentration range of 1.5-300 ng/mL. Lower limit of quantification achieved was 1.5 ng/mL with precision < 10% using 10 microL injection volume. The mean relative recovery of analyte (97.36%) and IS (99.93%) was consistent and reproducible. Interbatch and intrabatch precision was < 8.0% and the accuracy determined was within +/- 8% in terms of relative error.  相似文献   

15.
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method has been developed for the determination of caudatin-2,6-dideoxy-3-O-methy-beta-d-cymaropyranoside (CDMC) in rat plasma. This method involves a plasma clean-up step using liquid-liquid extraction, followed by LC separation and positive electrospray ionization mass spectrometry detection (LC/ESI-MS/MS). Chromatographic separation of the analytes was achieved using a C(18) column with a mobile phase of acetonitrile and water (70:30, v/v) at a flow rate of 1.0 mL/min. Low energy collision tandem mass spectrometric analysis (CID-MS/MS) using the multiple reaction monitoring (MRM) mode was used for analyte quantification. For the MRM analysis of CDMC, the following transition at m/z 658.4 --> 529.6 derived from the protonated molecule [M + Na](+). A calibration curve was linear in the 5-500 ng/mL range for CDMC, and the limit of detection was 5 ng/mL. The inter- and intra-day precisions (RSD) were 相似文献   

16.
In this work, a high-throughput and high-performance bioanalytical system is described that is capable of extracting and analyzing 1152 plasma samples within 10 hours. A Zymark track robot system interfaced with a Tecan Genesis liquid handler was used for simultaneous solid-phase extraction of four 96-well plates in a fully automated fashion. The extracted plasma samples were injected onto four parallel monolithic columns for separation via a four-injector autosampler. The use of monolithic columns allowed for fast and well-resolved separations at a considerably higher flow rate without generating significant column backpressure. This resulted in a total chromatographic run cycle time of 2 min on each 4.6 x 100 mm column using gradient elution. The effluent from the four columns was directed to a triple quadrupole mass spectrometer equipped with an indexed four-probe electrospray ionization source (Micromass MUX interface). Hence, sample extraction, separation, and detection were all performed in a four-channel parallel format that resulted in an overall throughput of about 30 s per sample from plasma. The performance of this system was evaluated by extracting and by analyzing twelve 96-well plates (1152) of human plasma samples spiked with oxazepam at different concentrations. The relative standard deviation (RSD) of analyte sensitivity (slope of calibration curve) across the four channels and across the 12 plates was 5.2 and 6.8%, respectively. An average extraction recovery of 77.6% with a RSD of 7.7% and an average matrix effect of 0.95 with a RSD of 5.2% were achieved using these generic extraction and separation conditions. The good separation efficiency provided by this system allowed for rapid method development of an assay quantifying the drug candidate and its close structural analog metabolite. The method was cross-validated with a conventional liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay.  相似文献   

17.
A flow injection/tandem mass spectrometric assay was developed to quantitate SC-68328 in dog plasma using its stable isotopic analog [13C4]SC-68328 as an internal standard (IS). Since SC-68328, a manganese-based superoxide dismutase mimetic, is very unstable, very polar and adheres to silica-based high-performance liquid chromatographic columns, the analyte and IS were derivatized to their bis-isothiocyanate forms followed by a liquid-liquid extraction with methylene chloride and analyzed using positive ion electrospray mass spectrometric detection. SC-68328 was quantitated using the peak-height ratio of SC-68328 to its IS using MS/MS in the multiple reaction monitoring mode. The lower limit of quantitation of the assay was 0.25 microg ml(-1) SC-68328 in dog plasma with an inter-day precision of 11.8% and an accuracy of 113% (n = 12). Acceptable precision and accuracy were also obtained for concentrations in the calibration curve range (0.25-10 microg ml(-1) SC-68328 in dog plasma).  相似文献   

18.
A simple and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the simultaneous determination of JBP485, Gly–Sar and JBP923 in the cell lysates using methanol as a deproteinization solvent was developed and validated. Detection was performed by turbo ionspray ionization in multiple reaction monitoring mode using the transitions of m/z 147.1 → m/z 90.1 for Gly–Sar, m/z 201.1 → m/z 86.1 for JBP485, m/z 219.1 → m/z 86.1 for JBP923 and m/z 152.0 → m/z 110.0 for paracetamol (internal standard). The analytes were separated on a Hypersil ODS C18 HPLC column using isocratic elution mode with a mobile phase containing 0.1% formic acid in water–methanol (97:3, v/v) at a flow rate of 0.2 mL/min. The calibration curves were demonstrated to be linear over the concentration range of 5.00?5000 nm with coefficient of 0.9968 for Gly–Sar, 0.9975 for JBP485 and 0.9952 for JBP923. The intra‐ and inter‐day precisions were <10.2% for each quality contro; level, and the accuracy was within ±5.6% for each analyte. The matrix effect, the extraction recovery and stabilities of LC‐MS/MS analysis were also investigated. This validated method was successfully applied to the simultaneous determination of JBP485, Gly–Sar and JBP923 in the cell lysates for identification of stably transfected HeLa cells with human PEPT1. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
Co-administration of synthetic progestin containing hormonal contraceptives (HCs) and antiepileptic drugs (AEDs) is a common clinical situation which needs specific considerations due to drug interactions. Several studies have demonstrated that lamotrigine plasma levels are significantly decreased during co-medication with HCs, and that this interaction is associated with increased seizure frequency in most of the cases. Additionally, an increase in contraceptive failure and unintended pregnancy could be observed during co-medication. Hence, monitoring of progestin plasma levels in patients with AED co-medication is of interest. A rapid and reliable online solid-phase extraction-high performance liquid chromatography–tandem mass spectrometry (online SPE-LC-MS/MS) method using gradient elution in the LC domain was established and validated for the simultaneous quantitative determination of gestodene, dienogest, drospirenone, etonogestrel, cyproterone acetate, and levonorgestrel in human plasma. The online SPE-LC-MS/MS method covered a quantification concentration range of 5–100 ng/ml for dienogest, 1–100 ng/ml for etonogestrel and 2–100 ng/ml for all other analytes. Stable isotope-labeled internal standards were used for analyte quantification based on selected reaction monitoring experiments. Inter- and intra-assay precision and accuracy were determined from quality control (QC) samples at the lower limits of quantification and at low, medium, and high concentration levels within the calibration range. Inter-assay reproducibility at the QC levels was better than 10% (relative standard deviation, RSD), accuracy at these levels ranged from −3.7% to 11.3%. Total extraction efficiency, tested at three concentrations, ranged from 92.5% to 106.4%. Matrix interferences were excluded by post-column infusion experiments. To prove the applicability of the assay in clinical cohorts, a sample set (n = 298) stemming from study patients under AED/oral HC co-medication was screened for progestin plasma levels. This method has to be considered a research-use-only assay and must not be used for diagnostic or therapeutic purposes, since it did not undergo formal performance evaluation in the sense of the IVD directive (98/79/EG) of the European Community.  相似文献   

20.
In response to recent discoveries of acrylamide in heated foods, a solid-phase extraction and cleanup protocol was developed for the determination of acrylamide in fried or baked potato samples by liquid chromatography/mass spectrometry (LC/MS). The analyte was extracted from the matrix by using 2M NaCl, and an aliquot of the initial extract was loaded onto a reversed-phase cartridge. After the analyte was eluted from the cartridge, the eluate was cleaned up on a mixed-mode cation-exchange cartridge. The eluate was then evaporated, and the residue was reconstituted in mobile phase before LC/MS analysis. Recoveries, based on the recovery of an added internal standard, ranged from 96 to 101% with relative standard deviations (RSDs) of 5-11%. The response was linear for a concentration range of 100-2000 ng/g with a coefficient of determination (R2) of 0.992 (n = 25). An interday study showed good accuracy and precision of the method over a 3-day period with a recovery of 98% and an RSD of 9.5% (n = 15). The analyses of 6 potato chip samples showed concentrations of incurred acrylamide ranging from 260 to 1500 ng/g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号