首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
A 162.5 MHz, 2.1 MeV radio frequency quadruples (RFQ) structure is being designed for the Injector Scheme Ⅱ of the China Accelerator Driven Sub-critical System (C-ADS) linac. The RFQ will operate in continuous wave (CW) mode as required. For the CW normal conducting machine, the heat management will be one of the most important issues, since the temperature fluctuation may cause cavity deformation and lead to the resonant frequency shift. Therefore a detailed multi-physics analysis is necessary to ensure that the cavity can stably work at the required power level. The multi-physics analysis process includes RF electromagnetic analysis, thermal analysis, mechanical analysis, and this process will be iterated for several cycles until a satisfactory solution can be found. As one of the widely accepted measures, the cooling water system is used for frequency fine tunning, so the tunning capability of the cooling water system is also studied under different conditions. The results indicate that with the cooling water system, both the temperature rise and the frequency shift can be controlled at an acceptable level.  相似文献   

2.
SSC-LINAC是为兰州重离子研究装置(HIRFL)设计的直线注入器,它将U34+离子加速到1 MeV/u注入到分离扇回旋加速器(SSC)中,为冷却储存环(CSR)提供10 MeV/u的U34+。该注入器可以将SSC引出的重离子流强提高一个量级以上。SSC-LINAC由一个RFQ(Radio Frequency Quadrupole)加速器和4个DTL(drift tube linac)组成,设计频率为53.667 MHz。RFQ工作在连续波模式,设计功率30 kW,如果不能有效地冷却,高频电流在电极表面产生的热量会使RFQ的腔壁和电极发生形变,从而导致腔体频率的漂移以及加速和聚焦电场的改变。因此,为了保证连续波工作的RFQ加速器稳定运行,对水冷模式和通道设计提出了很高的要求。作者用有限元软件ANSYS对RFQ进行高频电磁场、温度场、结构应力的耦合分析,验证了冷却方案设计的可行性和可靠性。Heavy Ion Research Facility at Lanzhou(HIRFL) consists of SFC, SSC, CSRm and CSRe. A new linac injector, which will increase U34+ to 1 MeV/u, is designed for SSC to increase the beam intensity to ten times higher. The new injector, whose frequency is 53.667 MHz, is composed by a RFQ (Radio Frequency Quadrupole) cavity and four DTL(Drift Tube Linac) cavities. The RFQ cavity, whose RF power is 30 kW, is operated at CW(continuous wave) mode. The heat produced by HF (high frequency) electromagnetic will cause deformation of RFQ structure, lead to the resonant frequency shift, and reduce the focusing efficiency of the cavity. An efficient cooling system is necessary to ensure that the RFQ cavity can stably be operated at the nominal frequency. A detailed multi-physics field coupling analysis of RFQ has been finished with 3D finite elements software ANSYS. The result of the analysis shows that the water cooling system can cool the RFQ cavity fully and keep the frequency drift be in a acceptable level.  相似文献   

3.
A linear accelerator as a new injector for the Separated Sector Cyclotron at the Heavy Ion Research Facility of LAN Zhou is being designed. The Drift-Tube-Linac (DTL) has been designed to accelerate 238U34+ from 0.140 MeV/u to 0.97 MeV/u [1]. The 3D finite element analysis of thermal behavior is presented in this paper. During operation, the cavity will produce Joule heat. The cavity will not work normally due to the high temperature and thermal deformation will lead to frequency drift. So it is necessary to perform thermal analysis to ensure the correct working temperature is used. The result of the analysis shows that after the water cooling system is put into the cavity the temperature rise is about 20 degrees and the frequency drift is about 0.15%.  相似文献   

4.
Frequency shifts of the acetylene saturated absorption lines at 1.5μm with temperature, gas pressure and laser power have been investigated in detail. The second-order Doppler effect, the recoil effect, the Zeeman effect, the pressure shift and the power shift are taken into consideration. The magnitudes of those shifts caused by various effects are evaluated. In order to reproduce the stability of 5.7 × 10^-14 obtained by Edwards, all necessary conditions are given. The results show that when there is a larger external magnetic field, the Zeeman shift could not be neglected, so that the shield should be employed. And the design of a long cavity is advantageous to reduce the influence of the second-order Doppler effect. The results also show that at least 4-2.5℃ temperature control for cavity can effectively prevent several effects and improve the frequency stability.  相似文献   

5.
A re-buncher with spiral arms for a heavy ion linear accelerator named as SSC-LINAC at HIRFL (the heavy ion research facility of Lanzhou) has been constructed. The re-buncher, which is used for beam longitudinal modulation and matching between the RFQ and DTL, is designed to be operated in continuous wave (CW) mode at the Medium-Energy Beam-Transport (MEBT) line to maintain the beam intensity and quality. Because of the longitudinal space limitation, the re-buncher has to be very compact and will be built with four gaps. We determined the key parameters of the re-buncher cavity from the simulations using Microwave Studio software, such as the resonant frequency, the quality factor Q and the shunt impedance. The detailed design of a 53.667 MHz spiral cavity and measurement results of its prototype will be presented.  相似文献   

6.
To investigate the feasibility of using a form cutter to machine the Radial Matcher Section (RMS) of the Radio Frequency Quadrupole (RFQ) for the Accelerator Driven System (ADS) project at Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS), the influence of RMS end shape on the RFQ cavity frequency is studied. The results indicate that using a form cutter to machine the RMS of an RFQ will indeed influence the cavity frequency. The RMS end shape will give more influence to a shorter RFQ cavity. For the 4.2 m ADS RFQ, the influence is negligible, which means that a form cutter can be used to machine the RMS.  相似文献   

7.
A new method for laser-frequency stabilization by controlling the pulse setup time is presented. The frequency-stabilization system monitors the pulse setup time continuously, and controls it by adjusting the cavity length. Laser frequency is stabilized to the center of the gain curve when the setup time is the shortest. The system is used to stabilize a radio-frequency-excited waveguide CO 2 laser tuned by grating, and the shift of laser frequency is estimated to be less than ±25 MHz for an extended period. The system has the advantages of compact structure, small volume, and low cost. It can be applied for frequency stabilization of other kinds of pulsed lasers with adjustable cavity.  相似文献   

8.
The relationship between the photothermal cooling efficiency of a micro-cantilever's mechanical mode and the en- vironmental temperature is studied. The micro-cantilever and a polished fiber end form a low finesse Fabry-Perot (FP) cavity. Experimental results in a temperature range from 77 K to 298 K show that temperature has an obvious influence on photothermal cooling efficiency. The photothermal cooling efficiency, ηph, at 100 K is 10 times that at 298 K. This accords well with the theoretical analysis that the high photothermal cooling efficiency can be achieved when photothermal response time, τph, and mechanical resonant frequency, ω0, are close to the optimal photothermal cooling condition ω0τph = 1. Our study provides an important approach for high effective photothermal cooling and high-sensitivity measurement for force microscopy.  相似文献   

9.
The relationship between the photothermal cooling efficiency of a micro-cantilever’s mechanical mode and the environmental temperature is studied. The micro-cantilever and a polished fiber end form a low finesse Fabry–Perot(FP)cavity. Experimental results in a temperature range from 77 K to 298 K show that temperature has an obvious influence on photothermal cooling efficiency. The photothermal cooling efficiency, ηph, at 100 K is 10 times that at 298 K. This accords well with the theoretical analysis that the high photothermal cooling efficiency can be achieved when photothermal response time, τph, and mechanical resonant frequency, ω0, are close to the optimal photothermal cooling condition ω0τph = 1. Our study provides an important approach for high effective photothermal cooling and high-sensitivity measurement for force microscopy.  相似文献   

10.
The conceptual design of a cryogenic system at temperature 2 K for the Peking University Free Electron Laser (PKU-FEL) facility is carried out. In order to minimize the scale of the cryogenic system and the running cost, the superconducting accelerator and the superconducting injector will mainly run at a long-pulsed mode. Optimization of the 2-K cryogenic system is carried out based on the heat load estimation and running parameters. Total cooling power of 52.5 W for the long-pulsed mode is necessary for the PKU cryogenic system. The PKU cryogenic system will be the first 2-K system for accelerators in China and will provide experience for similar facilities.  相似文献   

11.
At least two bunchers are needed in the 3MeV H Medium Energy Beam Transport (MEBT) line located between RFQ and DTL for the CSNS (China Spallation Neutron Source). A nose-cone geometry has been adopted as the type of buncher cavity for its simplicity, higher impedance and lower risk of multipacting. By making use of the results got from the simulations on the buncher with two-dimension code SUPERFISH, the thermal and structural analyses have been carried out, the process and results to determine the resulting frequency shift due to thermal and structural distortion of the cavity are presented, the water-cooling channel position and the optimum cooling water temperature as well as the tuning method by adjusting the cooling water temperature when the cavity is out of resonance are also determined through the analyses.  相似文献   

12.
We propose an efficient scheme for realizing two-mode squeezing for two cavity modes with an atomic ensemble trapped in the cavity and driven by two classical fields. Through a suitable choice of the driving classical fields, the evolution dynamics of the two cavity modes is decoupled with the atomic system and described by a two-mode squeezing operator. We show that a highly squeezed state can be obtained at the output even with a bad cavity. The required experimental techniques are within the scope of what can be obtained in the BEG-cavity setup.  相似文献   

13.
刘利伟  谭磊  黄刚 《中国物理 B》2011,20(1):14205-014205
A theoretical study is carried out for the modification and implication of the effect on the Ξ-type three level atom in a high-finesse optical cavity driven by light field including spontaneous emission and the cavity decay. Analytic expressions for the dipole force, the friction force, the optical potentials and the friction coefficient are obtained. Then the numerical and graphical methods are used to investigate the friction coefficient with the controlling parameters. It is shown that the friction coefficient is strongly dependent on the controlling parameters. The cooling rate can increase by one order of magnitude more than that of a two-level atomic system. The reason can be given using the dressed states and the Sisyphus cooling mechanism, which would stimulate further experimental investigations.  相似文献   

14.
由于束流的传输效率对射频四极场加速器(RFQ) 中射频场的分布极其敏感,所以在RFQ 的运行过程中不再采用传统的调谐器调谐RFQ。水冷调谐的方法基本上不影响RFQ 射频场的分布,所以适用于RFQ 的调谐。中国科学院高能物理研究所为C-ADS、CSNS 预研RFQ 项目开发建造了一套水冷调谐系统,使用RF 相位差作为控制量进行RFQ 水冷调谐,相位差的控制精度达到了1°运行结果显示该系统满足了RFQ 的调谐需求。介绍了该系统的水冷系统、调谐控制系统和一些运行经验。Since the beam transmission of a Radio Frequency Quadrupole(RFQ) Accelerator is very sensitive to the field profile, the ordinary frequency tuning method by the local movable tuner is no more adopted in an RFQ operation. The tuning method by controlling cooling water temperature is widely adopted to tune the RFQ due to the less affect on the RFQ field profile. A Resonance Control Cooling System (RCCS) is developed and commissioned for the 973 RFQ,which is a R&D project for C-ADS and CSNS RFQ at IHEP. This system adopts the RF phase difference as control variable to tune the RFQ. The control accuracy of the RF phase difference is about 1°. The running of the 973 RFQ shows that the RCCS works very well and fully satisfies the operation requirement of the RFQ. In this paper, the water skid, resonance control system of the RCCS and the operation experiences will be presented.  相似文献   

15.
We propose a ground-state cooling scheme for a nanomechanical oscillator(NMO)that interacts with an optical cavity via radiation pressure at one side and with a superconducting microwave cavity via a capacitor at the other side.By driving these two cavities on their respective red sidebands with extra laser and microwave fields,the NMO’s dual cooling channel is created through electro-optomechanical cooperation.Differing from the conventional optomechanical system with a single optical cavity wherein ground-state cooling is limited in the resolved sideband,the proposed scheme allows the optical cavity to function in an unresolved sideband regime under the cooperation of a microwave cavity with a high quality factor,or vice versa.In a weak coupling regime we demonstrate that the NMO can be cooled to near its ground-state from a finite temperature with a cooling rate that is significantly faster than that of the single-cavity optomechanical system.The heating process can be completely suppressed by the cooperation of the dual cooling channel by appropriately selecting the system’s parameters.With a decreasing thermal phonon number,the numerical results of final mechanical occupancy gradually approach the analytical cooling limit.  相似文献   

16.
We introduce a new method of frequency-shifting for a diode laser in laser cooling experiments, the method is based on the Zeeman egect of^87 Rb atoms. The laser frequency is stabilized by absorption spectrum line of atoms in magnetic field. We show that a magnetic field can be added up to 10^-2T. The corresponding frequency shift is 10^2 MHz and the response time is about 1ms. The large range of the frequency shift is suffcient for laser-cooling experiments.  相似文献   

17.
An ECR O~ ion source and LEBT system have been developed for the upgrade of 1MeV Integral Split Ring RFQ at Peking University.To satisfy the requirement of RFQ,a more than 10mA oxygen beam has been extracted at 22kV through a 5mm diameter aperture.Its normalized root-mean-square emmitance is less than 0.1π·mm·mrad,which is required by RFQ accelerator.The LEBT matching section is redesigned upon the bench test results.The preliminary results will be presented in this paper.  相似文献   

18.
RF system design and measurement of HIRF-CSRe   总被引:1,自引:0,他引:1  
An RF system for the CSRe (cooling storage experimental ring) is designed and manufactured domestically. The present paper mainly describes the RF system design in five main sections: ferrite ring, RF cavity, RF generator, low level system and cavity cooling. The cavity is based on a type of coaxial resonator which is shorted at the end with one gap and loaded with domestic ferrite rings. The RF generator is designed in the push-pull mode and the low level control system is based on a DSP+FGPA+DDS+USB interface and has three feedback loops. Finally we give the results of the measurement on our system.  相似文献   

19.
The progress of the Separated Function RFQ (SFRFQ) accelerator, which can raise the field gradient of acceleration while maintaining the transverse focusing power sufficient for high current beam, is presented. In order to demonstrate the feasibilities of the novel accelerator, a prototype cavity was designed and constructed. Correspondingly, a code SFRFQCODEV1.0 was developed specially for cavity design and beam dynamics simulation. The prototype cavity will be verified as a post-accelerator for ISR RFQ-1000 (Integral Split Ring RFQ) and  相似文献   

20.
The high-current superconducting proton linac is being studied for the accelerator-driven system (ADS) project undertaken by the Chinese Academy of Sciences. The injector Ⅱ will be operated at 162.5 MHz, and the proton out from the RFQ with an energy of 2.5 MeV will be accelerated to 10 MeV by two cryo-modules, which are composed of eight superconducting half wave resonance cavities and nine solenoids. In this paper, the design and beam simulation of the superconducting section of the injector Ⅱ, the acceptance calculation and a stability analysis are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号