首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Elastic nature of the viscoelastic fluids induces lateral migration of particles into a single streamline and can be used by microfluidic based flow cytometry devices. In this study, we investigated focusing efficiency of polyethylene oxide based viscoelastic solutions at varying ionic concentration to demonstrate their use in impedimetric particle characterization systems. Rheological properties of the viscoelastic fluid and particle focusing performance are not affected by ionic concentration. We investigated the viscoelastic focusing dynamics using polystyrene (PS) beads and human red blood cells (RBCs) suspended in the viscoelastic fluid. Elasto‐inertial focusing of PS beads was achieved with the combination of inertial and viscoelastic effects. RBCs were aligned along the channel centerline in parachute shape which yielded consistent impedimetric signals. We compared our impedance‐based microfluidic flow cytometry results for RBCs and PS beads by analyzing particle transit time and peak amplitude at varying viscoelastic focusing conditions obtained at different flow rates. We showed that single orientation, single train focusing of nonspherical RBCs can be achieved with polyethylene oxide based viscoelastic solution that has been shown to be a good candidate as a carrier fluid for impedance cytometry.  相似文献   

2.
Saliva and blood plasma are non-Newtonian viscoelastic fluids that play essential roles in the transport of particulate matters (e.g., food and blood cells). However, whether the viscoelasticity of such biofluids alters the dynamics of suspended particles is still unknown. In this study, we report that under pressure-driven microflows of both human saliva and blood plasma, spherical particles laterally migrate and form a focused stream along the channel centerline by their viscoelastic properties. We observed that the particle focusing varied among samples on the basis of sampling times/donors, thereby demonstrating that the viscoelasticity of the human biofluids can be affected by their compositions. We showed that the particle focusing, observed in bovine submaxillary mucin solutions, intensified with the increase in mucin concentration. We expect that the findings from this study will contribute to the understanding of the physiological roles of viscoelasticity of human biofluids.  相似文献   

3.
The inertial microfluidic technique, as a powerful new tool for accurate cell/particle separation based on the hydrodynamic phenomenon, has drawn considerable interest in recent years. Despite numerous microfluidic techniques of particle separation, there are few articles in the literature on separation techniques addressing external outlet geometry to increase the throughput efficiency and purity. In this work, we report on a spiral inertial microfluidic device with high efficiency (>98%). Herein, we demonstrate how changing the outlet geometry can improve the particle separation throughput. We present a complete separation of 4 and 6 μm from 10 μm particles potentially applicable to separate microalgae (Tetraselmis suecica from Phaeodactylum tricornutum). Two spiral microchannels with the same cross section dimension but different outlet geometry were considered and tested to investigate the particle focusing behavior and separation efficiency. As compared with particle focusing observed in channels with a simple outlet, the particle focusing in a modified outlet geometry appears in a more successful focusing manner with complete separation. This simple approach of particle separation makes it attractive for lab-on-a-chip devices for continuous extraction and filtration of a wide range of cell/particle sizes.  相似文献   

4.
《Electrophoresis》2018,39(2):417-424
Herein, we proposed a strategy for controlling the particle focusing position in Dean‐coupled elasto‐inertial flows via adjusting the polymer concentration of viscoelastic fluids. The physics behind the control strategy was then explored and discussed. At high polymer concentrations, the flowing particles could be single‐line focused exactly at the channel centerline under the dominated elastic force. The center‐line focusing in our spiral channel may employed as a potential pretreatment scheme for microflow cytometry detection. With further decreasing polymer concentrations, the particles would shift into the outer channel region under the comparable competition between inertial lift force, elastic force and Dean drag force. Finally, the observed position‐shifting was successfully employed for particle concentration at a throughput much higher than most existing elasto‐inertial microfluidics.  相似文献   

5.
Microparticle separation and concentration based on size has become indispensable in many biomedical and environmental applications. In this paper we describe a passive microfluidic device with spiral microchannel geometry for complete separation of particles. The design takes advantage of the inertial lift and viscous drag forces acting on particles of various sizes to achieve differential migration, and hence separation, of microparticles. The dominant inertial forces and the Dean rotation force due to the spiral microchannel geometry cause the larger particles to occupy a single equilibrium position near the inner microchannel wall. The smaller particles migrate to the outer half of the channel under the influence of Dean forces resulting in the formation of two distinct particle streams which are collected in two separate outputs. This is the first demonstration that takes advantage of the dual role of Dean forces for focusing larger particles in a single equilibrium position and transposing the smaller particles from the inner half to the outer half of the microchannel cross-section. The 5-loop spiral microchannel 100 microm wide and 50 microm high was used to successfully demonstrate a complete separation of 7.32 microm and 1.9 microm particles at Dean number De = 0.47. Analytical analysis supporting the experiments and models is also presented. The simple planar structure of the separator offers simple fabrication and makes it ideal for integration with on-chip microfluidic systems, such as micro total analysis systems (muTAS) or lab-on-a-chip (LOC) for continuous filtration and separation applications.  相似文献   

6.
Choi YS  Seo KW  Lee SJ 《Lab on a chip》2011,11(3):460-465
The inertial migration of particles in micro-scale flows has received much attention due to its promising applications, such as the membrane-free passive separation of particles or cells. The particles suspended in rectangular channels are known to be focused near the center of each channel face as the channel Reynolds number (R(C)) increases due to the lift force balance and the hydrodynamic interactions of the particles with the wall. In this study, the three-dimensional positions of neutrally buoyant spherical particles inside a square microchannel are measured using the digital holographic microscopy technique, and a transition from the lateral tubular pinch to the cross-lateral focusing with increasing R(C) is reported. The particles are found to migrate first in the lateral direction and then cross-laterally toward the four equilibrium positions. A general criterion that can be used to secure the fully developed state of particle focusing in Lab-on-a-Chip applications is also derived. This criterion could be helpful for the accurate estimation of the design parameters of inertial microfluidic devices, such as R(C), channel length and width, and particle diameter.  相似文献   

7.
Parichehreh V  Sethu P 《Lab on a chip》2012,12(7):1296-1301
A new microfluidics technique that exploits the selectivity of phase partitioning and high-speed focusing capabilities of the inertial effects in flow was developed for continuous label-free sorting of particles and cells. Separations were accomplished by introducing particles at the interface of polyethylene glycol (PEG) and dextran (DEX) phases in rectangular high aspect-ratio microfluidic channels and allowing them to partition to energetically favorable locations within the PEG phase, DEX phase or interface at the center of the microchannel. Separation of partitioned particles was further enhanced via inertial lift forces that develop in high aspect-ratio microchannels that move particles to equilibrium positions close to the outer wall. Combining phase partitioning with inertial focusing ensures selectivity is possible using phase partitioning with sufficient throughput (at least an order of magnitude greater than phase partitioning alone) for application in the clinical and research setting. Using this system we accomplished separation of 15 μm polystyrene (PS) particles from 1-20 μm polymethylmethacrylate (PMMA) particles. Results confirm the feasibility of separation based on phase partitioning and enhancement of separation via inertial focusing. Approximately 86% of PS particles were isolated within the PEG phase whereas 78% of PMMA particles were isolated within the DEX phase. When a binary mixture of PS and PMMA was introduced within the device, ~83% of PS particles were isolated in the PEG phase and ~74% of PMMA particles were isolated in the DEX phase. These results confirm the feasibility of this technique for rapid and reliable separation of particles and potentially cells.  相似文献   

8.
Microfluidic particle focusing has been a vital prerequisite step in sample preparation for downstream particle separation, counting, detection, or analysis, and has attracted broad applications in biomedical and chemical areas. Besides all the active and passive focusing methods in Newtonian fluids, particle focusing in viscoelastic fluids has been attracting increasing interest because of its advantages induced by intrinsic fluid property. However, to achieve a well-defined focusing position, there is a need to extend channel lengths when focusing micrometer-sized or sub-microsized particles, which would result in the size increase of the microfluidic devices. This work investigated the sheathless viscoelastic focusing of particles and cells in a zigzag microfluidic channel. Benefit from the zigzag structure of the channel, the channel length and the footprint of the device can be reduced without sacrificing the focusing performance. In this work, the viscoelastic focusing, including the focusing of 10 μm polystyrene particles, 5 μm polystyrene particles, 5 μm magnetic particles, white blood cells (WBCs), red blood cells (RBCs), and cancer cells, were all demonstrated. Moreover, magnetophoretic separation of magnetic and nonmagnetic particles after viscoelastic pre-focusing was shown. This focusing technique has the potential to be used in a range of biomedical applications.  相似文献   

9.
Zhu J  Hu G  Xuan X 《Electrophoresis》2012,33(6):916-922
The fundamental understanding of particle electrokinetics in microchannels is relevant to many applications. To date, however, the majority of previous studies have been limited to particle motion within the area of microchannels. This work presents the first experimental and numerical investigation of electrokinetic particle entry into a microchannel. We find that the particle entry motion can be significantly deviated from the fluid streamline by particle dielectrophoresis at the reservoir-microchannel junction. This negative dielectrophoretic motion is induced by the inherent non-uniform electric field at the junction and is insensitive to the microchannel length. It slows down the entering particles and pushes them toward the center of the microchannel. The consequence is the demonstrated particle deflection, focusing, and trapping phenomena at the reservoir-microchannel junction. Such rich phenomena are studied by tuning the AC component of a DC-biased AC electric field. They are also utilized to implement a selective concentration and continuous separation of particles by size inside the entry reservoir.  相似文献   

10.
An approach to sample and analyze single aerosolized droplets (<10 nL) of solutions containing fluorescein isothiocyanate (FITC) labeled glycine (GLY) and glutamic acid (GLU) is demonstrated. The sampling approach is based on inertial impaction in which the sample particle is accelerated through a nozzle and directly into a small drop of buffered solution (20 mM borate, pH = 10) suspended at the end of a coaxial tube of stainless steel and a fused silica capillary. A spherical light scattering cell and laser (λ = 532 nm) is used to detect the arrival of particles at the buffered droplet. Upon dissolution and/or mixing, a portion of the sample is injected onto the fused silica capillary for subsequent chemical analysis by capillary electrophoresis (CE) and detection by laser-induced fluorescence (LIF). It was found that the inertial impaction approach sampled particles >1 μm diameter with an efficiency of 80% or greater. At 15 kV applied potential, the FITC conjugates of GLY and GLU could be resolved in less than 120 s allowing qualitative analysis of the contents of single dispersed particles. However, the extent to which the sample is diluted into the buffer droplet varied significantly on a per-particle basis that caused >80% R.S.D. in fluorescence peak heights. This aspect of the method would necessitate the use of internal standards for quantitative analysis of materials present within the particles. It is envisaged that further improvements to the device described may ultimately lead to analysis of the contents of single particles dispersed in earth's atmosphere.  相似文献   

11.
Many biomedical analysis applications require trapping and manipulating single cells and cell clusters within microfluidic devices. Dielectrophoresis (DEP) is a label-free technique that can achieve flexible cell trapping, without physical barriers, using electric field gradients created in the device by an electrode microarray. Little is known about how fluid flow forces created by the electrodes, such as thermally driven convection and electroosmosis, affect DEP-based cell capture under high conductance media conditions that simulate physiologically relevant fluids such as blood or plasma. Here, we compare theoretical trajectories of particles under the influence of negative DEP (nDEP) with observed trajectories of real particles in a high conductance buffer. We used 10-µm diameter polystyrene beads as model cells and tracked their trajectories in the DEP microfluidic chip. The theoretical nDEP trajectories were in close agreement with the observed particle behavior. This agreement indicates that the movement of the particles was highly dominated by the DEP force and that contributions from thermal- and electroosmotic-driven flows were negligible under these experimental conditions. The analysis protocol developed here offers a strategy that can be applied to future studies with different applied voltages, frequencies, conductivities, and polarization properties of the targeted particles and surrounding medium. These findings motivate further DEP device development to manipulate particle trajectories for trapping applications.  相似文献   

12.
惯性效应在微流控芯片中的应用   总被引:3,自引:0,他引:3  
项楠  朱晓璐  倪中华 《化学进展》2011,23(9):1945-1958
作为一种操控粒子或流体的新技术,基于流体惯性的操控技术已被应用于微流控芯片中粒子的输运、分选、聚焦及试样的混合和反应等操作,而在微尺度惯性效应基础上的惯性微流控芯片由于具有高通量、无需外场介入、低成本、易集成及微型化等众多优点,可用于解决医疗诊断、生化分析、合成化学及环境监测等领域的检测分析和微量操控问题,因此对该技术的机理及应用研究已成为目前微流控技术领域一个重要的研究热点。本文在介绍惯性微流控芯片机理及其研究进展的同时,从惯性聚焦、惯性分选及基于Dean流的微混合器和微流控光学器件等几个方面对惯性微流控芯片的最新应用研究进展进行了较为详细的介绍和分析比较。在此基础上,分析了惯性微流控芯片的局限和未来需要解决的问题。  相似文献   

13.
Xuan X  Li D 《Electrophoresis》2005,26(18):3552-3560
The electrokinetic focusing and the resultant accelerated electrophoretic motion of polystyrene particles and red blood cells were visualized in microfluidic cross-channels. The experimentally measured width of the focused stream and the measured velocity increase of particles and cells at different voltage ratios follow the proposed analytical formula within the experimental error. The attained velocity increase is insensitive to the particle size, particle property (i.e., particle or cell), and particle trajectory. By solving the electrical potential field in the cross-channel at the experimental conditions, we demonstrate that the squeezed electrical field lines in the channel intersection determine the shape of the focused stream, and the nonuniform distribution of axial electrical field strength underlies the variation of particle/cell electrophoretic velocity through the focusing region. However, the dielectrophoretic force resulting from the nonuniform electrical field in the intersection seems to push the acceleration region of particles and cells slightly in the downstream direction. We have also achieved the single particle/cell dispensing by instantly triggering an electrical pulse perpendicular to the focused particulate flow in a double-cross microchannel. The electrokinetic manipulation of particle/cell in microchannels demonstrated in this work can be used for developing integrated lab-on-a-chip devices for studies of cells.  相似文献   

14.
Bhagat AA  Hou HW  Li LD  Lim CT  Han J 《Lab on a chip》2011,11(11):1870-1878
Blood is a highly complex bio-fluid with cellular components making up >40% of the total volume, thus making its analysis challenging and time-consuming. In this work, we introduce a high-throughput size-based separation method for processing diluted blood using inertial microfluidics. The technique takes advantage of the preferential cell focusing in high aspect-ratio microchannels coupled with pinched flow dynamics for isolating low abundance cells from blood. As an application of the developed technique, we demonstrate the isolation of cancer cells (circulating tumor cells (CTCs)) spiked in blood by exploiting the difference in size between CTCs and hematologic cells. The microchannel dimensions and processing parameters were optimized to enable high throughput and high resolution separation, comparable to existing CTC isolation technologies. Results from experiments conducted with MCF-7 cells spiked into whole blood indicate >80% cell recovery with an impressive 3.25 × 10(5) fold enrichment over red blood cells (RBCs) and 1.2 × 10(4) fold enrichment over peripheral blood leukocytes (PBL). In spite of a 20× sample dilution, the fast operating flow rate allows the processing of ~10(8) cells min(-1) through a single microfluidic device. The device design can be easily customized for isolating other rare cells from blood including peripheral blood leukocytes and fetal nucleated red blood cells by simply varying the 'pinching' width. The advantage of simple label-free separation, combined with the ability to retrieve viable cells post enrichment and minimal sample pre-processing presents numerous applications for use in clinical diagnosis and conducting fundamental studies.  相似文献   

15.
This paper presents an innovative micro flow cytometer which is capable of counting and sorting cells or particles. This compact device employs electrokinetic forces rather than the more conventional hydrodynamic forces technique for flow focusing and sample switching, and incorporates buried optical fibers for the on-line detection of cells or particles. This design approach results in a compact microfluidic system and an easier integration process. The proposed cytometer integrates several critical modules, namely electrokinetic-focusing devices, built-in control electrodes, buried optical fibers for on-line detection, and electrokinetic flow switches for bio-particle collection. A linear relationship exists between the focused stream width (d) and the focusing ratio (F/φ), which is estimated to be D≈134.5−53.8F/φ. The relationship between the particle velocity (U) and the applied voltage (V) is also investigated. Numerical and experimental data confirm the effectiveness of the device when applied to the counting and sorting of 10 μm diameter particles and red blood cells.  相似文献   

16.
In this study, the vertical motion of a particle in a quiescent fluid falling toward a horizontal plane wall is analyzed, based on simplified models. Using the distance between the particle and wall as a parameter, the effects of various forces acting on the particle and the particle motion are examined. Without the colloidal and Brownian forces being included, the velocity of small particles is found to be approximately equal to the inverse of the drag force correction function used in this study as the particle approaches the near-wall region. Colloidal force is added to the particle equation of motion as the particle moves a distance comparable to its size. It is found that the particle might become suspended above or deposited onto the wall, depending on the Hamaker constant, the surface potentials of the particle and wall, and the thickness of the electrical double layer (EDL). For strong EDL repulsive force and weaker van der Waals (VDW) attractive force, the particle will become suspended above the wall at a distance at which the particle velocity is zero. This location is referred to as the equilibrium distance. The equilibrium distance is found to increase with increased in EDL thickness when a repulsive force barrier appears in the colloidal force interaction. For the weak EDL repulsive force and strong VDW attractive force case, the particle can become deposited onto the wall without the Brownian motion effect. The Brownian jump length was found to be very small. Many Brownian jumps would be required in a direction toward the wall for a suspended particle to become deposited.  相似文献   

17.
A method to continuously separate different particle types in a suspension is reported. Acoustic forces in a standing wave field were utilized to discriminate lipid particles from erythrocytes in whole blood. The presented technology proposes a new method of cleaning, i.e. removing lipid emboli from, shed blood recovered during cardiac surgery. Blood contaminated with lipid particles enter a laminar flow micro channel. Erythrocytes and lipid particles suspended in blood plasma are exposed to a half wavelength standing wave field orthogonal to the direction of flow as they pass through the channel. Because of differences in compressibility and density the two particle types move in different directions, the erythrocytes towards the centre of the channel and the lipid particles towards the side walls. The end of the channel is split into three outlet channels conducting the erythrocytes to the centre outlet and the lipid particles to the side outlets due to the laminar flow profile. The separation channel was evaluated in vitro using polyamide spheres suspended in water, showing separation efficiencies approaching 100%. The system was also evaluated on whole blood using tritium labelled lipid particles added to bovine blood. More than 80% of the lipid particles could be removed while approximately 70% of the erythrocytes were collected in one third of the original fluid volume. The study showed that the further reduced micro channel dimensions provided improved performance with respect to; (i) separation efficiency, (ii) actuation voltage, and (iii) volumetric throughput as compared to earlier work.  相似文献   

18.
《Electrophoresis》2018,39(4):597-607
We report herein a novel microfluidic particle concentrator that utilizes constriction microchannels to enhance the flow‐focusing performance of induced‐charge electroosmosis (ICEO), where viscous hemi‐spherical oil droplets are embedded within the mainchannel to form deformable converging‐diverging constriction structures. The constriction region between symmetric oil droplets partially coated on the electrode strips can improve the focusing performance by inducing a granular wake flow area at the diverging channel, which makes almost all of the scattered sample particles trapped within a narrow stream on the floating electrode. Another asymmetric droplet pair arranged near the outlets can further direct the trajectory of focused particle stream to one specified outlet port depending on the symmetry breaking in the shape of opposing phase interfaces. By fully exploiting rectification properties of induced‐charge electrokinetic phenomena at immiscible water/oil interfaces of tunable geometry, the expected function of continuous and switchable flow‐focusing is demonstrated by preconcentrating both inorganic silica particles and biological yeast cells. Physical mechanisms responsible for particle focusing and locus deflection in the droplet‐assisted concentrentor are analyzed in detail, and simulation results are in good accordance with experimental observations. Our work provides new routes to construct flexible electrokinetic framework for preprocessing on‐chip biological samples before performing subsequent analysis.  相似文献   

19.
Magnetism and microfluidics   总被引:4,自引:0,他引:4  
Pamme N 《Lab on a chip》2006,6(1):24-38
Magnetic forces are now being utilised in an amazing variety of microfluidic applications. Magnetohydrodynamic flow has been applied to the pumping of fluids through microchannels. Magnetic materials such as ferrofluids or magnetically doped PDMS have been used as valves. Magnetic microparticles have been employed for mixing of fluid streams. Magnetic particles have also been used as solid supports for bioreactions in microchannels. Trapping and transport of single cells are being investigated and recently, advances have been made towards the detection of magnetic material on-chip. The aim of this review is to introduce and discuss the various developments within the field of magnetism and microfluidics.  相似文献   

20.
Wang L  Flanagan LA  Monuki E  Jeon NL  Lee AP 《Lab on a chip》2007,7(9):1114-1120
A novel dielectrophoresis switching with vertical electrodes in the sidewall of microchannels for multiplexed switching of objects has been designed, fabricated and tested. With appropriate electrode design, lateral DEP force can be generated so that one can dynamically position particulates along the width of the channel. A set of interdigitated electrodes in the sidewall of the microchannels is used for the generation of non-uniform electrical fields to generate negative DEP forces that repel beads/cells from the sidewalls. A countering DEP force is generated from another set of electrodes patterned on the opposing sidewall. These lateral negative DEP forces can be adjusted by the voltage and frequency applied. By manipulating the coupled DEP forces, the particles flowing through the microchannel can be positioned at different equilibrium points along the width direction and continue to flow into different outlet channels. Experimental results for switching biological cells and polystyrene microbeads to multiple outlets (up to 5) have been achieved. This novel particle switching technique can be integrated with other particle detection components to enable microfluidic flow cytometry systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号