相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
An imaging spectrograph equipped with a CCD detector was employed to measure two-dimensional emission images from a glow discharge plasma in atomic emission spectrometry. The emission images at Zn I 334.50 nm for a zinc sample and at Cu I 324.75 nm for a copper sample could be obtained. Their emission intensities were not uniform in the radial direction of the plasma region but became weaker at larger distance from the central zone. The two-dimensional distribution would result from a spatial variation in the excitation efficiency of the plasma and thus provide useful information for understanding the excitation processes occurring in the plasma.  相似文献   

2.
Elastic spheres in contact deform around the contact region, due to intermolecular interaction forces. The deformed contacting surfaces change the distance between interacting molecules that in turn alters the force of interaction. Thus, the contact behavior of elastic spheres constitutes a nonlinear mathematical problem that defies the traditional analytical methods for general solution. Efficient computational techniques have enabled a detailed study of adhesive contact behavior of elastically deformable spheres with self-consistent solutions of a nonlinear integral governing equation. The present work extends the previous computational analysis to the quantities of practical interests such as the pull-off force and the radius of contact area. Trends of variations in the pull-off force as physical properties change are examined. Computationally determined radial positions as stress condition indicators suggest that the concept of contact radius is not clearly defined in the literature and can be confusing. It seems that some contact mechanics models would be consistent with the definition of the edge of contact area as the radial position for the local surface stress to change from compression to tension, whereas others would rather assume the contact radius as the radial position for the local tensile stress to reach its peak. The substantial quantitative deviation of self-consistently computed contact radius from the DMT model prediction suggests that models based on the assumption of a well-defined contact area having a constant gap may not be appropriate when describing cases of small values of Tabor's parameter. Copyright 2001 Academic Press.  相似文献   

3.
Total and full-energy peak efficiencies, coincidence correction factors and the source self-absorption of a p-type coaxial HPGe detector for cylindrical sources have been calculated using direct analytical expressions. In the experiments gamma aqueous sources containing several radionuclides covering the energy range from 60 to 1836 keV were used. By comparison, the theoretical and experimental full-energy peak efficiency values are in good agreement.  相似文献   

4.
The concept of representing a cylindrical detector volume as a virtual point detector in order to simplify the evaluation of the detector efficiency was proposed in the past for HPGe detectors in the case of measuring point sources. In the present work, the validity of the point detector model was studied and confirmed for the direct measurement of small volume sources, when using a common 7.5×7.5 cm2 NaI(T1) detector.  相似文献   

5.
A new 'hybrid' ion cyclotron resonance (ICR) trap is proposed and analyzed by computer simulations. The trap is basically a hybrid of a segmented end cap (Infinity) and capacitively coupled cylindrical cell, with additional electrodes placed at the center of each end cap. The new trap produces an on-axis electric field z-profile similar to that of the Infinity cell or capacitively coupled open cylindrical cell during ion excitation. Simion simulations demonstrate that, during detection, appropriate changes of the potentials applied to the two new sets of electrodes produce a radial electric field z-profile that more closely approaches that for an ideal axial three-dimensional quadrupolar potential at high post-excitation ICR orbital radius, for improved signal-to-noise ratio and resolving power, and minimal m/z-discrimination.  相似文献   

6.
During electrolysis of molten KF-2HF, strongly adherent fluorine bubbles are generated at the surface of carbon anode. The current was passing even if the horizontal anode was fully covered with gas film. The formation and growth of gas bubbles were studied by transient electrochemical techniques. It was observed that the fluorine bubbles do not have the spherical cap shape predicted by the classical theory. The curvature radius of the interface profile is not constant, the edge of the bubble being flat with a contact angle close to zero. The results are interpreted in the frame of a model which takes into account the predominant role of the interfacial properties.  相似文献   

7.
The aim of this work is to develop a physical model to describe the evolution of the apparent contact angle for four different liquids on nanotextured alumina surfaces with different pore radius. The nanoporous alumina templates were fabricated by anodization of Al foil in a 0.3 M oxalic acid solution. Scanning electron microscopy was used to characterize the morphology of the surfaces. The templates are approximately 400 nm in thickness and consist of a well-ordered hexagonal array of uniform radius pores spaced 105 nm apart with pore radii from 12 to 42 nm. The wettability of nanoporous alumina templates was investigated using contact-angle measurements. We measured the contact angles using four liquids: water, ethylene glycol, aniline, and a mixture of ethylene glycol and aniline. We developed a new theoretical model for the contact angle on nanoporous surfaces as a function of the pore radius. This model is based on energy considerations and involves liquid penetration into the nanopores driven by the capillarity (Laplace's law). Because the air is compressed inside the pores, this model also includes the effect of the line tension. This is important because the three-phase line length is greatly enhanced in our nanoporous structures. For example: for a millimeter-sized droplet, the three-phase line around the perimeter of the droplet is a few millimeters long, whereas the total three-phase line within the pores can reach several tens of meters. Using our model, the line-tension value for our nanopore samples is positive and ranges from 4 to 13 × 10(-9) N, which falls within the wide interval from 10(-11) to 10(-5) N quoted in the literature. Nanoporous surfaces may allow the effect of line tension to be visible for micro- to macrodroplets.  相似文献   

8.
A HPLC-detector has been designed which employs light-emitting diodes in the deep-UV-range below 300 nm as wavelength specific radiation sources and special UV-photodiodes for measuring the signal. A monochromator is therefore not needed. The design features a beam splitter and a reference photodiode, precision mechanics for adjustment of the light beams and electronics for stabilization of the LED-current. The processing of the photodiode currents is carried out with a high performance log-ratio amplifier which allows direct absorbance measurements. The optical and electronic performance of the detector was characterised and high precision over several absorbance units was obtained. Testing of analytical separation methods in isocratic as well as gradient modes employing UV-detection at 255 and 280 nm showed a very similar performance to a commercial photodiode-array detector used in the fixed wavelength mode in terms of linearity, precision and detection limits. The chief advantages of the new device are small size, low power consumption, and low cost.  相似文献   

9.
Summary The paper deals with the common mistake of interpolating calculation of the efficiency of gamma-detectors by the inverse square law of the distance of the source from the detector cap and suggests the use of the distance from the virtual point detector instead.  相似文献   

10.
The dependence of the capillary adhesion force F(cap) between a silica microsphere and a flat silica surface versus a time period t of the samples' contact (i.e., dwell-in time) is experimentally investigated using atomic force microscopy (AFM). F(cap) was found to be dependent on t if the humidity was >30-35%. This dependence is exponential, with decay (characteristic) times of ~10 s. It is suggested that the kinetics of the adhesion process are related to the growth of the water annulus between surfaces. Furthermore, we propose that the growth kinetics has two components: (1) water vapor diffusion from the surrounding humid media into the gap between samples and (2) water drainage from the gap. The theory of diffusion through thin pores (i.e., gaps) is developed, and analytical formulas are obtained for the dependence of the meniscus radius r versus time t. However, the experimental dependence of F(cap) versus t and, consequently, r versus t obtained in this article disagrees with the theoretical prediction by several orders of magnitude. Similar results were obtained from the literature data for capillary forces between an AFM cantilever tip and a flat surface. Possible reasons for the deviation from diffusion theory are suggested: surface and Knudsen regimes of vapor diffusion, nonsteady state vapor flow, and tortuosity. Taking into account the viscous drainage of water from the multilayer gap can explain the experimental kinetics of bridge formation, but only if the viscosity of the adjacent multilayer of water is several orders of magnitude larger than the bulk viscosity.  相似文献   

11.
采用高压静电纺丝技术, 在非对称异型电极上制备得到放射状聚酰亚胺(PI)纳米纤维膜. 采用环境扫描电子显微镜(ESEM)观察了PI膜的微观形貌以及纳米纤维的排列状态; 采用接触角测量仪研究了水滴浸润性的变化; 采用高敏感性力学微电力学天平测量了水滴的黏附力, 分析了微观形貌变化与水滴浸润性质和黏附性质的关系. 结果表明, 该PI纳米纤维膜沿着非对称异型电极三角电极至弧型电极方向纤维排列由密到疏, 呈放射状, 具有独特的微结构梯度; 整个纤维膜上的PI纳米纤维直径均一且具有光滑均匀表面, 纤维与纤维之间的距离约为几微米到几十微米. 由于PI纳米纤维膜所具有的独特的微结构梯度, 致使沿着微结构梯度方向水滴的接触角(从超疏水到疏水)和黏附力(从低黏附到高黏附)均表现出梯度变化的特征.  相似文献   

12.
Asymmetrical flow field-flow fractionation (FFF) with multi-angle light scattering (MALS) detection was applied for the fractionation of amylopectins from four different sources. Samples originated from genetically modified potatoes and waxy maize. Amylopectins were dissolved in a 1 mol l(-1) sodium hydroxide solution or water. With an injected mass of 0.2 microg, well below overloading conditions, a decrease of the apparent hydrodynamic radius with increasing inlet flow-rate was observed. Moreover, a decrease of the radius of gyration with increasing elution volume was recorded by the MALS detector. Steric/hyperlayer effects are a feasible explanation for this behaviour. The observed radius of gyration at the steric inversion point was in the order of 0.3 microm, which is smaller than the theoretically calculated inversion point. Apparently, the amylopectin behave as macromolecules with a larger hydrodynamic radius than expected on basis of their radius of gyration and are subjected to significant lift forces. The results were confirmed by four fractionations with varying flow-rates but constant ratio of cross to outlet-flow. In contrast to the normal mode operation, the retention of the amylopectins depended strongly on the applied flow-rates and was close to that of a much smaller 10 kDa dextran. Apparent molar masses in the order of between 10(7) and 10(9) g mol(-1) were obtained. The results are contrasted with enzymatically degraded and oxidised starch samples that were fractionated in the normal mode.  相似文献   

13.
14.
The In-Situ Object Calibration Software (ISOCS) and the Laboratory Sourceless Calibration Software (LabSOCS) developed and patented by Canberra Industries have found widespread use in the gamma-spectrometry community. Using the ISOCS methodology, one can determine the full energy peak efficiencies of a germanium detector in the 45 keV-7 MeV energy range, for practically any source matrix and geometry. The underlying mathematical techniques used in ISOCS (and LabSOCS) have undergone significant improvements and enhancements since their first release in 1996. One of these improvements is  a spatial response characterization technique that is capable of handling the large variations in efficiency that occurs within a small region. The technique has been in use in ISOCS and LabSOCS releases since 1999, and has significantly improved the overall quality of the close-in and off-axis response characterization for HPGe detectors, especially for Canberra’s Broad Energy Germanium (BEGe) detectors. In this method, the detector response is characterized by creating a set of fine spatial efficiency grids at 15 energies in the 45 keV-7 MeV range. The spatial grids are created in (r,⊝) space about the detector, with the radius r varying from 0 to 500 meters, and the angle ⊝ varying from 0 to π. The reference efficiencies for creating the spatial grids are determined from MCNP calculations using a validated detector model. Once the efficiency grids are created, the detector response can be determined at any arbitrary point within a sphere of 500-meter radius, and at any arbitrary energy within the specified range. Results are presented highlighting the improved performance achieved using the gridding methodology.  相似文献   

15.
An electrostatic ion guide (EIG) that consists of concentric cylinder and central wire electrodes can transport ions efficiently from an external ion source to an ion cyclotron resonance (ICR) ion trap for mass analysis, with several advantages over current injection methods. Because the electrostatic force of the EIG captures ions in a stable orbit about the wire electrode, ions with initially divergent trajectories may be redirected toward the ICR ion trap for improved ion transmission efficiency. SIMION trajectory calculations (ion kinetic energy, 1–200 eV; elevation angle, 0.30 °; azimuthal angle, 0.360°) predict that ions of m/z 1000 may be transmitted through a strong (0.01 → 3.0-T) magnetic field gradient. Judicious choice of ion source position and EIG potential minimizes the spread in ion axial kinetic energy at the ICR ion trap. Advantages of the EIG include large acceptance angle, even for ions that have large initial kinetic energy and large radial displacement with respect to the central z-axis, low ion extraction voltage (5–20 V), and efficient trapping because ions need not be accelerated to high velocity to pass through the magnetic field gradient.  相似文献   

16.
The effects of viscous heat dissipation on some important HPLC parameters, such as efficiency (N) and retention factors (k), using 2.1mm columns at pressures up to 1000 bar have been investigated from both a theoretical and experimental point of view. Two distinct experimental set-ups and their respective influences on non-homogenous temperature gradients within the column are described and discussed. In the first instance, a still-air column heater was used. This set-up leads to approximate 'adiabatic' conditions, and a longitudinal temperature gradient is predicted across the length of the column. The magnitude of this gradient is calculated, and its occurrence confirmed with experimental measurements also indicating that no appreciable loss in efficiency occurs. Secondly, when a water bath is used to thermostat the column, a radial temperature gradient is prevalent. The extent of this gradient is estimated, and the loss in efficiency associated with this gradient is predicted and demonstrated experimentally. It is also observed that approximate adiabatic conditions can lead to floating retention factors. The implications of temperature gradients for routine HPLC analysis at ultra-high pressure are discussed.  相似文献   

17.
The radial distribution of the main characteristics (elution time and standard deviation) of the elution profiles of a flat injected band recorded at the exit of a monolithic column were determined. These distributions provide the radial distributions of the average mobile phase velocity, the elution time and the maximum height of the peak of an analyte, the column efficiency and the analyte concentration. The band profiles were measured at the exit of a 10-mm i.d., 100-mm long silica-based monolithic column. An on-column local electrochemical amperometric detector allowed the recording of the elution profiles at different spatial positions throughout the column cross-section. The local spatial distribution of the mobile phase velocity does not follow a piston-flow behavior but exhibits radial heterogeneity. The local efficiency near the wall is lower than that near the column center. The radial distribution of the maximum concentration of the peaks varies throughout the column exit section, partially due to the radial variations of the column efficiency. These results might explain the rather large value of the A term of the Van Deemter or the Knox equations reported previously for monolithic columns.  相似文献   

18.
The effect of radial ion-track distribution on the transient current in semiconductors caused by a high-energy heavy ion strike was studied. Reasonable agreement was observed in experimental and calculated transient currents for ion energies ranging from several to several hundred MeV when the radius of the ion track used in the numerical simulations was shorter or equivalent to that of the penumbra radius.  相似文献   

19.
Cambio is a software application well-suited for analysis of high-resolution nuclear spectral data in which the critical information resides in well-masked peaks or in which the data are sparse and good statistics cannot be obtained. The statistical uncertainty in the results is reported in terms of standard deviations. In the practical use of any analysis application, it is important to have a good understanding of the accuracy of the reported statistical uncertainties in the results. The authors report the results of an experiment that provides a quantitative measure of the accuracy of the reported uncertainties in analyses using Cambio. Ten calibration sources ranging in activity from 25 to 450 kBq were placed 20.5 m from a bare, 100 % relative-efficient high-purity germanium detector. Peaks in these sources occur from 20 to 2,800 keV. Data were accumulated for 128 h to create a parent spectrum from which 1024 8-hour statistically-equivalent daughter spectra were created by random sampling of the parent spectrum data. The parent spectrum was analyzed by fitting parameters which included an underlying continuum, a background of natural peaks adjusted by detector efficiency and material attenuation, and a foreground of the ten sources adjusted by detector efficiency only. Each of the daughter spectra were then analyzed starting with the parameters of the fit to the parent spectrum and then minimizing Chi-square with respect to changes in these parameters. The standard deviations of the estimated activities of the sources from all 1024 spectra were then calculated and compared to the reported statistical uncertainty in the activities and peak areas of the sources.  相似文献   

20.
The effects of particle size and thermal insulation on retention and efficiency in packed-column supercritical fluid chromatography with large pressure drops are described for the separation of a series of model n-alkane solutes. The columns were 2.0 mm i.d. × 150 mm long and were packed with 3, 5, or 10-μm porous octylsilica particles. Separations were performed with pure carbon dioxide at 50 °C at average mobile phase densities of 0.47 g/mL (107 bar) and 0.70 g/mL (151 bar). The three principal causes of band broadening were the normal dispersion processes described by the van Deemter equation, changes in the retention factor due to the axial density gradient, and radial temperature gradients associated with expansion of the mobile phase. At the lower density the use of thermal insulation resulted in significant improvements in efficiency and decreased retention times at large pressure drops. The effects are attributed to the elimination of radial temperature gradients and the concurrent enhancement of the axial temperature gradient. Thermal insulation had no significant effect on chromatographic performance at the higher density. A simple expression to predict the onset of excess efficiency loss due to the radial temperature gradient is proposed.  相似文献   