首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
A tunable diode laser (TDL) is used to measure the absorption spectra of the R46 through R54 transitions of the 2001200001 band of CO2 near 2.0 μm (5000 cm−1) at room temperature and pressures to 10 atm (densities to 9.2 amagat). Spectra are recorded using direct absorption spectroscopy and wavelength modulation spectroscopy with second-harmonic detection (WMS-2f) in a mixture containing 11% CO2 in air. The direct absorption spectra are influenced by non-Lorentzian effects including finite-duration collisions which perturb far-wing absorption, and an empirical χ-function correction to the Voigt line shape is shown to greatly reduce error in the spectral model. WMS-2f spectra are shown to be at least a factor of four less-influenced by non-Lorentzian effects in this region, making this approach more resistant to errors in the far-wing line shape model and allowing a comparison between the spectral parameters of HITRAN and a new database which includes pressure-induced shift coefficients. The implications of these measurements on practical, high-pressure CO2 sensor design are discussed.  相似文献   

2.
Tunable diode-laser absorption of CO2 near 2.7 μm incorporating wavelength modulation spectroscopy with second-harmonic detection (WMS-2f) is used to provide a new sensor for sensitive and accurate measurement of the temperature behind reflected shock waves in a shock-tube. The temperature is inferred from the ratio of 2f signals for two selected absorption transitions, at 3633.08 and 3645.56 cm−1, belonging to the ν 1+ν 3 combination vibrational band of CO2 near 2.7 μm. The modulation depths of 0.078 and 0.063 cm−1 are optimized for the target conditions of the shock-heated gases (P∼1–2 atm, T∼800–1600 K). The sensor is designed to achieve a high sensitivity to the temperature and a low sensitivity to cold boundary-layer effects and any changes in gas pressure or composition. The fixed-wavelength WMS-2f sensor is tested for temperature and CO2 concentration measurements in a heated static cell (600–1200 K) and in non-reactive shock-tube experiments (900–1700 K) using CO2–Ar mixtures. The relatively large CO2 absorption strength near 2.7 μm and the use of a WMS-2f strategy minimizes noise and enables measurements with lower concentration, higher accuracy, better sensitivity and improved signal-to-noise ratio (SNR) relative to earlier work, using transitions in the 1.5 and 2.0 μm CO2 combination bands. The standard deviation of the measured temperature histories behind reflected shock waves is less than 0.5%. The temperature sensor is also demonstrated in reactive shock-tube experiments of n-heptane oxidation. Seeding of relatively inert CO2 in the initial fuel-oxidizer mixture is utilized to enable measurements of the pre-ignition temperature profiles. To our knowledge, this work represents the first application of wavelength modulation spectroscopy to this new class of diode lasers near 2.7 μm.  相似文献   

3.
A mid-infrared absorption strategy with calibration-free wavelength-modulation-spectroscopy (WMS) has been developed and demonstrated for real-time, in situ detection of nitric oxide in particulate-laden combustion-exhaust gases up to temperatures of 700 K. An external-cavity quantum-cascade laser (ECQCL) near 5.2 μm accessed the fundamental absorption band of NO, and a wavelength-scanned, 1f-normalized WMS with second-harmonic detection (WMS-2f/1f) strategy was developed. Due to the external-cavity laser architecture, large nonlinear intensity modulation (IM) was observed when the wavelength was modulated by injection-current modulation, and the IM indices were also found to be strongly wavelength-dependent as the center wavelength was scanned with piezoelectric tuning of the cavity. A quantitative model of the 1f-normalized WMS-2f signal was developed and validated under laboratory conditions. A sensor was subsequently designed, built and demonstrated for real-time, in situ measurements of NO across a 3 m path in the particulate-laden exhaust of a pulverized-coal-fired power plant boiler. The 1f-normalized WMS-2f method proved to have better noise immunity for non-absorption transmission, than wavelength-scanned direct absorption. A 0.3 ppm-m detection limit was estimated using the R15.5 transition near 1927 cm−1 with 1 s averaging. Mid-infrared QCL-based NO absorption with 1f-normalized WMS-2f detection shows excellent promise for practical sensing in the combustion exhaust.  相似文献   

4.
A fast-response (100 kHz) tunable diode laser absorption sensor is developed for measurements of temperature and H2O concentration in shock tubes, e.g. for studies of combustion chemistry. Gas temperature is determined from the ratio of fixed-wavelength laser absorption of two H2O transitions near 7185.60 cm-1 and 7154.35 cm-1, which are selected using design rules for the target temperature range of 1000–2000 K and pressure range of 1–2 atm. Wavelength modulation spectroscopy is employed with second-harmonic detection (WMS-2f) to improve the sensor sensitivity and accuracy. Normalization of the second-harmonic signal by the first-harmonic signal is used to remove the need for calibration and minimize interference from emission, scattering, beam steering, and window fouling. The laser modulation depth for each H2O transition is optimized to maximize the WMS-2f signal for the target test conditions. The WMS-2f sensor is first validated in mixtures of H2O and Ar in a heated cell for the temperature range of 500–1200 K (P=1 atm), yielding an accuracy of 1.9% for temperature and 1.4% for H2O concentration measurements. Shock wave tests with non-reactive H2O–Ar mixtures are then conducted to demonstrate the sensor accuracy (1.5% for temperature and 1.4% for H2O concentration) and response time at higher temperatures (1200–1700 K, P=1.3–1.6 atm). PACS 42.62.Fi; 42.55.Px; 42.60.Fc; 07.35.+k  相似文献   

5.
The expressions of the second harmonic(2f) signal are derived on the basis of absorption spectral and lock-in theories.A parametric study indicates that the phase shift between the intensity and wavelength modulation makes a great contribution to the 2f signal.A self-calibration wavelength modulation spectroscopy(WMS) method based on tunable diode laser absorption spectroscopy(TOLAS) is applied,combining the advantages of ambient pressure,temperature suppression,and phase-shift influences elimination.Species concentration is retrieved simultaneously from selected 2f signal pairs of measured and reference WMS-2f spectra.The absorption line of acetylene(C_2H_2) at 1530.36 nm near-infrared is selected to detect C_2H_2 concentrations in the range of 0-400 ppmv.System sensitivity,detection precision and limit are markedly improved,demonstrating that the self-calibration method has better detecting performance than the conventional WMS.  相似文献   

6.
根据对激光器施加的调制信号是否连续,波长调制光谱分为连续和准连续调制激光吸收光谱技术。为了深入的比较研究这两种方案,设计准连续调制谱专用的软件锁相放大器,将准连续调制信号因间断产生的无效信号滤除后,再对吸收信号解调得到二次谐波信号。与连续激光调制谱软件解调的二次谐波信号进行了比较,结果表明,参数相同,准连续调制谱比连续调制谱的信噪比提高5%、检测限降低11.3%。在滤除无效信号后,准连续调制谱也可以解调出标准的二次谐波信号,因此有望用于与气体线型相关的研究中。该工作为选取更加适用的激光调制谱技术,提供了准确依据。  相似文献   

7.
Tunable diode lasers (TDLs) are used to measure high resolution (0.1 cm-1), near-infrared (NIR) water vapor absorption spectra at 700 K and pressures up to 30 atm within a high-pressure and -temperature optical cell in a high-uniformity tube furnace. Both direct absorption and wavelength modulation with second harmonic detection (WMS-2f) spectra are obtained for 6 cm-1 regions near 7204 cm-1 and 7435 cm-1. Direct absorption measurements at 700 K and 10 atm are compared with simulations using spectral parameters from HITRAN and a hybrid database combining HITRAN with measured spectral constants for transitions in the two target spectral regions. The hybrid database reduces RMS error between the simulation and the measurements by 45% for the 7204 cm-1 region and 28% for the 7435 cm-1 region. At pressures above 10 atm, the breakdown of the impact approximation inherent to the Lorentzian line shape model becomes apparent in the direct absorption spectra, and measured results are in agreement with model results and trends at elevated temperatures reported in the literature. The wavelength-modulation spectra are shown to be less affected by the breakdown of the impact approximation and measurements agree well with the hybrid database predictions to higher pressures (30 atm). PACS 33.20.Ea; 42.62.Fi; 52.25.Os  相似文献   

8.
A general model for 1f-normalized wavelength modulation absorption spectroscopy with nf detection (i.e., WMS-nf) is presented that considers the performance of injection-current-tuned diode lasers and the reflective interference produced by other optical components on the line-of-sight (LOS) transmission intensity. This model explores the optimization of sensitive detection of optical absorption by species with structured spectra at elevated pressures. Predictions have been validated by comparison with measurements of the 1f-normalized WMS-nf (for n = 2–6) lineshape of the R(11) transition in the 1st overtone band of CO near 2.3 μm at four different pressures ranging from 5 to 20 atm, all at room temperature. The CO mole fractions measured by 1f-normalized WMS-2f, 3f, and 4f techniques agree with calibrated mixtures within 2.0 %. At conditions where absorption features are significantly broadened and large modulation depths are required, uncertainties in the WMS background signals due to reflective interference in the optical path can produce significant error in gas mole fraction measurements by 1f-normalized WMS-2f. However, such potential errors can be greatly reduced by using the higher harmonics, i.e., 1f-normalized WMS-nf with n > 2. In addition, less interference from pressure-broadened neighboring transitions has been observed for WMS with higher harmonics than for WMS-2f.  相似文献   

9.
A trace gases detection system based on integrated cavity output spectroscopy (ICOS) was developed, where a NIR tunable diode laser (TDL) was used as light source, an optical cavity composed by two plan-concave mirrors with reflection near 99.7% was used as the absorption cell. Trace water vapour (H2O), carbon dioxide (CO2), methane (CH4), carbon monoxide (CO) and mixture of CO2 and CO were tested by ICOS based on the characteristics absorption. The wavelength calibration, cavity transmission characteristics, quantitative measurement ability and sensitivity of the TDL-ICOS were also studied, and a evaluated minimum detectable sensitivity of 1.15 × 10?7 cm?1 was obtained when the system was used to CH4 detection. The experiment results show that TDL-ICOS is expected to be a reliable and promising system for the detection of trace gases since it has some advantages such as real-time monitoring, simple device, easy operation, high sensitivity, good stability and quantitative ability.  相似文献   

10.
马欲飞  何应  于欣  于光  张静波  孙锐 《物理学报》2016,65(6):60701-060701
采用石英增强光声光谱(QEPAS)技术对CO痕量气体展开检测研究. 为了实现超高灵敏度探测, 采用输出波长为4.6 μm的新颖中红外高功率分布反馈量子级联激光器为光源, 实现了对CO气体基频吸收带的激发与测量. 在优化了调制深度、气体压强和提高了CO分子的振动-转动弛豫速率后, 获得了1.95 ppbv的优异探测极限. 在分析检测结果的过程中, 讨论了能级寿命对信号强度的影响, 并对QEPAS信号强度的表达式进行了修正.  相似文献   

11.
针对准连续激光调制吸收光谱谐波信号的解调,设计了一种专用的准连续软件锁相放大器,对采集的数据做有效性判断、 无效数据滤除、 数字相敏检测、 数字滤波等处理,实现了准连续激光调制吸收光谱的谐波信号解调。 构建气体检测实验系统,对准连续软件锁相放大器和商品化的高性能锁相放大器进行了对比实验,结果表明,使用准连续软件锁相放大器的Allan方差比后者小1个数量级、 检测限低2倍。 并能够解决小占空比时的信号失锁问题,具有小的信号波形失真。  相似文献   

12.
Infrared gas phase spectroscopy is becoming very common in many life science applications. Here we present three types of trace gas detection systems based on CO2 laser and continuous wave (cw) optical parametric oscillator (OPO) in combination with photoacoustic spectroscopy and cw quantum cascade laser (QCL) in combination with wavelength modulation spectroscopy. Examples are included to illustrate the suitability of CO2 laser system to monitor in real time ethylene emission from various dynamic processes in plants and microorganisms as well as from car exhausts. The versatility of an OPO-based detector is demonstrated by simultaneous detection of 13C-methane and 12C-methane (at 3240 nm) at similar detection limits of 0.1 parts per billion by volume. Recent progress on a QCL-based spectrometer using a continuous wave QCL (output power 25 mW, tuning range of 1891–1908 cm-1) is presented and a comparison is made to a standard chemiluminescence instrument for analysis of NO in exhaled breath. PACS  42.62 Be; 42.62 Fi  相似文献   

13.
We report what we believe to be a novel demonstration of simultaneous detection of multiple trace gases by near-IR tunable diode laser photoacoustic spectroscopy using a cell containing a cantilever microphone. Simultaneous detection of carbon monoxide (CO), ethyne (C2H2), methane (CH4) and combined carbon monoxide/carbon dioxide (CO+CO2) in nitrogen-based gas mixtures was achieved by modulation frequency division multiplexing the outputs of four near-IR tunable diode lasers. Normalized noise-equivalent absorption coefficients of 3.4×10?9, 3.6×10?9 and 1.4×10?9 cm?1?W?Hz?1/2 were obtained for the simultaneous detection of CO, C2H2 and CH4 at atmospheric pressure. These corresponded to noise-equivalent detection limits of 249.6 ppmv (CO), 1.5 ppmv (C2H2) and 293.7 ppmv (CH4) respectively over a measurement period of 2.6 s at the relevant laser power. The performance of the system was not influenced by the number of lasers deployed, the main source of noise arising from ambient acoustic effects. The results confirm that small-volume photoacoustic cells can be used with low optical power tunable diode lasers for rapid simultaneous detection of trace gases with high sensitivity and specificity.  相似文献   

14.
The 12 best NIR water transition line pairs for temperature measurements with a single DFB laser in flames are determined by systematic analysis of the HITRAN simulation of the water spectra in the 1–2 μm spectral region. A specific line pair near 1.4 μm was targeted for non-intrusive measurements of gas temperature in combustion systems using a scanned-wavelength technique with wavelength modulation and 2f detection. This sensor uses a single diode laser (distributed-feedback), operating near 1.4 μm and is wavelength scanned over a pair of H2O absorption transitions (7154.354 cm-1 & 7153.748 cm-1) at a 2 kHz repetition rate. The wavelength is modulated (f=500 kHz) with modulation amplitude a=0.056 cm-1. Gas temperature is inferred from the ratio of the second harmonic signals of the two selected H2O transitions. The fiber-coupled-single-laser design makes the system compact, rugged, low cost and simple to assemble. As part of the sensor development effort, design rules were applied to optimize the line selection, and fundamental spectroscopic parameters of the selected transitions were determined via laboratory measurements including the temperature-dependent line strength, self-broadening coefficients, and air-broadening coefficients. The new sensor design includes considerations of hardware and software to enable fast data acquisition and analysis; a temperature readout rate of 2 kHz was demonstrated for measurements in a laboratory flame at atmospheric pressure. The combination of scanned-wavelength and wavelength-modulation minimizes interference from emission and beam steering, resulting in a robust temperature sensor that is promising for combustion control applications.PACS 42.62.Fi; 42.55.Px; 42.60.Fc; 39.30+w  相似文献   

15.
可调谐半导体激光吸收光谱作为一种高灵敏度、高选择性、非侵入的痕量气体实时检测技术,已在大气监测、工业控制等方面得到广泛应用。采用一种新型宽带可调谐的SG-DBR半导体激光器(可调谐范围1 520~1 570 nm)作光源,并通过自编程序对该激光器设定了18个通道,输出波长分别对应CO,CO2以及H2O的吸收谱线中心位置,设计和构建了一个基于近红外可调谐半导体激光吸收光谱的多组分气体光谱测量系统,描述了相关的光学系统设置,结合波长调制(wm)的二次谐波技术测量其中14个通道(分别对应CO和CO2的吸收谱线)的吸收光谱,系统获得的CO和CO2峰值吸收探测极限能够达到10-5。实验结果验证了SG-DBR激光器在波长调制吸收光谱多组分气体检测领域的可行性。在实际应用过程中使用单个SG-DBR激光器可以实现多组分气体的同时测量,有效降低设备成本和系统复杂性。  相似文献   

16.
A quantum cascade laser(QCL) based system for simultaneous detection of CO and CO_2 is developed.The QCL can scan over two neighboring CO(2055.40 cm~(-1)) and CO_2(2055.16 cm~(-1)) lines with a single current scan.The wavelength modulation spectroscopy( f = 20 k Hz) is utilized to enhance the signal-to-noise ratio.A white cell with an effective optical path length of 74 m is used.The calibration of the sensor is performed and minimum detection limits of 1.3 ppb(1 × 10~(-9))for CO and 0.44 ppm(1 × 10~(-6)) for CO_2 are achieved.  相似文献   

17.
The amount of ammonia in exhaled breath has been linked to a variety of adverse medical conditions, including chronic kidney disease (CKD). The development of accurate, reliable breath sensors has the potential to improve medical care. Wavelength modulation spectroscopy with second harmonic normalized by the first harmonic (WMS 2f/1f) is a sensitive technique used in the development of calibration-free sensors. An ammonia gas sensor is designed and developed that uses a quantum cascade laser operating near 1,103.44 cm?1 and a multi-pass cell with an effective path length of 76.45 m. The sensor has a 7 ppbv detection limit and 5 % total uncertainty for breath measurements. The sensor was successfully used to detect ammonia in exhaled breath and compare healthy patients to patients diagnosed with CKD.  相似文献   

18.
Optical methods based on quantum cascade lasers (QCLs) are becoming popular in many life science applications. We report on two trace gas detection schemes based on continuous wave QCLs for on-line detection of nitric oxide (NO) at the sub-part-per-billion level by volume (ppbv, 1:10?9), using wavelength modulation spectroscopy (WMS) and Faraday rotation spectroscopy (FRS) at 1894 cm?1 and 1875.73 cm?1, respectively. Several technical incremental steps are discussed to further improve the sensitivity of these methods. Examples are included to demonstrate the merits of WMS-based sensor: direct monitoring of NO concentrations in exhaled breath, and from plants under pathogen attack. A simple hand-held breath sampling device that allows single breath collection at various exhalation flows (15, 50, 100 and 300 mL/s, respectively) is developed for off-line measurements and validated in combination with the WMS-based sensor. Additionally, the capability of plants to remove environmental NO is presented.  相似文献   

19.
We synthesized PVP/TiO2 nano-fibers doping with Ag colloid nano-particles by electro-spinning method. These nano-fibers were characterized by UV/visible/NIR spectroscopy, SEM and XRD. The image of SEM showed that the synthesized nano-fibers were monotonous and without knot and had a diameter about 150 nm. We also measured the nonlinear refractive and absorption indexes of the sample in three different intensities using the single beam Z-scan method by a continuous wave (CW) He–Ne laser at 632.8 nm wavelength. The nonlinear refraction indexes of these nano-fibers were measured in order of 10−7 (cm2/W) with negative sign and the nonlinear absorption coefficient was obtained in order of 10−3 (cm/W).  相似文献   

20.
Quartz-enhanced photoacoustic spectroscopy (QEPAS) is demonstrated for acetylene detection at atmospheric pressure and room temperature with a fiber-coupled distributed feedback (DFB) diode laser operating at ~1.53 μm. An efficient approach for gas concentration calibration is demonstrated. The effect of residual amplitude modulation on the performance of wavelength modulated QEPAS is investigated theoretically and experimentally. With optimized spectrophone parameters and modulation depth, a minimum detectable limit (1σ) of ~2 part-per-million volume (ppmv) was achieved with an 8.44-mW diode laser, which corresponds to a normalized noise equivalent coefficient (1σ) of 6.16 × 10?8 cm?1 W/Hz1/2.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号