Experiments were conducted to investigate flow boiling heat transfer to a dielectric fluid in a silicon chip-integrated microchannel heat sink. Twenty-four microchannels, each 389 μm × 389 μm in cross-section, were fabricated into the 12.7 mm × 12.7 mm silicon substrate. High-speed visualizations (at 12,500 frames per second) were performed simultaneously with heat transfer and pressure drop measurements to investigate the physics of flow boiling in parallel microchannel arrays. At low heat fluxes, bubbly flow is dominant, with the bubbles coalescing to form vapor slugs as the heat flux is increased. At high heat fluxes, the flow regimes in the downstream portion of the microchannels are characteristic of alternating wispy-annular flow and churn flow, while flow reversal is observed in the upstream region near the microchannel inlet. Local heat transfer measurements, obtained at three flow rates ranging from 35 to 60 ml/min, show that at lower heat fluxes, the heat transfer coefficient increases with increasing heat flux. The heat transfer coefficient in fully developed boiling is seen to be independent of flow rate in this range. At higher heat fluxes (exceeding 542, 673, 730 kW/m2, respectively, for flow rates of 35, 47 and 60 ml/min), this trend is reversed, and the heat transfer coefficient decreases with further increases in heat flux due to partial dryout in some of the microchannels. Heat fluxes at which fully developed boiling is achieved depend on the flow rate. The pressure drop in fully developed boiling increases with increasing heat flux and is independent of flow rate for the test conditions considered in this work.  相似文献   

2.
A numerical investigation of the mixed convection heat transfer from vertical helically coiled tubes in a cylindrical shell at various Reynolds and Rayleigh numbers, various coil‐to‐tube diameter ratios and non‐dimensional coil pitches was carried out. The particular difference in this study compared with other similar studies is the boundary conditions for the helical coil. Most studies focus on constant wall temperature or constant heat flux, whereas in this study it was a fluid‐to‐fluid heat exchanger. The purpose of this article is to assess the influence of the tube diameter, coil pitch and shell‐side mass flow rate on shell‐side heat transfer coefficient of the heat exchanger. Different characteristic lengths were used in the Nusselt number calculations to determine which length best fits the data and finally it has been shown that the normalized length of the shell‐side of the heat exchanger reasonably demonstrates the desired relation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
The gas–liquid–solid mini fluidized bed (GLSMFB) combines the advantages of fluidized bed and micro-reactor, and meets the requirements for safety and efficiency of green development of process industry. However, there are few studies on its flow performance and no studies on its mass and heat transfer performance. In this paper, the characteristics of gas–liquid mass transfer in a GLSMFB were studied in order to provide basic guidance for the study of GLSMFB reaction performance and application. Using CO2 absorption by NaOH as the model process, the gas–liquid mass transfer performance of GLSMFB was investigated. The results show that the liquid volumetric mass transfer coefficient and the gas–liquid interfacial area both increase with the increase of the superficial gas velocity within the experimental parameter range under the same given superficial liquid velocity. At the same ratio of superficial gas to liquid velocity, the liquid volumetric mass transfer coefficient increases with the increase of the superficial liquid velocity. Fluidized solid particles strengthen the liquid mass transfer process, and the liquid volumetric mass transfer coefficient is about 13% higher than that of gas–liquid mini bubble column.  相似文献   

4.
The objective of this study is to visualize the flow pattern and to measure heat transfer coefficient during explosive boiling of water in parallel triangular micro-channels. Tests were performed in the range of inlet Reynolds number 25–60, mass flux 95–340 kg/m2s, and heat flux 80–330 kW/m2.The flow visualization showed that the behavior of long vapor bubbles, occurring in a micro-channel at low Reynolds numbers, was not similar to annular flow with interposed intermitted slugs of liquid between two long vapor trains. This process may be regarded as explosive boiling with periodic wetting and dryout.In the presence of two-phase liquid–vapor flow in the micro-channel, there are pressure drop oscillations, which increase with increasing vapor quality.This study shows strong dependence of the heat transfer coefficient on the vapor quality. The time when liquid wets the heated surface decreases with increasing heat flux. Dryout occurs immediately after venting of the elongated bubble.  相似文献   

5.
Turbulent flow and convective heat transfer of a nanofluid made of Al2O3 (1–4 vol.%) and water through a square duct is numerically studied. Single-phase model, volumetric concentration, temperature-dependent physical properties, uniform wall heat flux boundary condition and Renormalization Group Theory k-ε turbulent model are used in the computational analysis. A comparison of the results with the previous experimental and numerical data revealed 8.3 and 10.2 % mean deviations, respectively. Numerical results illustrated that Nu number is directly proportional with Re number and volumetric concentration. For a given Re number, increasing the volumetric concentration of nanoparticles does not have significant effect on the dimensionless velocity contours. At a constant dimensionless temperature, increasing the particle volume concentration increases the size of the temperature profile. Maximum value of dimensionless temperature increases with increasing x/Dh value for a given Re number and volumetric concentration.  相似文献   

6.
A mathematical model based on the annular flow pattern is developed to simulate the evaporation of refrigerants flowing under varied heat flux in a double tube evaporator. The finite difference form of governing equations of this present model is derived from the conservation of mass, energy and momentum. The experimental set-up is designed and constructed to provide the experimental data for verifying the simulation results. The test section is a 2.5 m long counterflow double tube heat exchanger with a refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tube is made from smooth horizontal copper tubing of 9.53 mm outer diameter and 7.1 mm inner diameter. The agreement of the model with the experimental data is satisfactory. The present model can be used to investigate the axial distributions of the temperature, heat transfer coefficient and pressure drop of various refrigerants. Moreover, the evaporation rate or the other relevant parameters that is difficult to measure in the experiment are predicted and presented here. The results from the present mathematical model show that the saturation pressure and temperature of refrigerant decrease along the tube due to the tube wall friction and the flow acceleration of refrigerant. The liquid heat transfer coefficient increases with the axial length due to reducing the thickness of the liquid refrigerant film. Due to increase of the liquid heat transfer coefficient, increasing wall heat flux is obtained.Finally, the evaporation rate of refrigerant increases with increasing wall heat flux.  相似文献   

7.
In the present study, the heat transfer characteristics in dry surface conditions of a new type of heat exchanger, namely a helically coiled finned tube heat exchanger, is experimentally investigated. The test section, which is a helically coiled fined tube heat exchanger, consists of a shell and a helical coil unit. The helical coil unit consists of four concentric helically coiled tubes of different diameters. Each tube is constructed by bending straight copper tube into a helical coil. Aluminium crimped spiral fins with thickness of 0.5 mm and outer diameter of 28.25 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Ambient air is used as a working fluid in the shell side while hot water is used for the tube-side. The test runs are done at air mass flow rates ranging between 0.04 and 0.13 kg/s. The water mass flow rates are between 0.2 and 0.4 kg/s. The water temperatures are between 40 and 50°C. The effects of the inlet conditions of both working fluids flowing through the heat exchanger on the heat transfer coefficients are discussed. The air-side heat transfer coefficient presented in term of the Colburn J factor is proportional to inlet-water temperature and water mass flow rate. The heat exchanger effectiveness tends to increase with increasing water mass flow rate and also slightly increases with increasing inlet water temperature.  相似文献   

8.
Heat transfer characteristics of hydrodynamically developing laminar flow in a circular duct with different thermal boundary conditions were calculated by solving the equations of continuity, motion and energy in finite difference form. Results are presented for linear, sinusoidal and exponential variations of the prescribed wall heat flux along the duct length. A comparison shows that the influence of the thermal boundary condition on heat transfer increases with increasing development of velocity and temperature profiles. As a side result an improved correlation for heat transfer with constant wall heat flux in hydrodynamically developing flow is presented.  相似文献   

9.
The condensation heat transfer characteristics for CO2 flowing in a horizontal microfin tube were investigated by experiment with respect to condensation temperature and mass flux. The test section consists of a 2,400?mm long horizontal copper tube of 4.6?mm inner diameter. The experiments were conducted at refrigerant mass flux of 400–800?kg/m2s, and saturation temperature of 20–30?°C. The main experimental results showed that annular flow was highly dominated the majority of condensation flow in the horizontal microfin tube. The condensation heat transfer coefficient increases with decreasing saturation temperature and increasing mass flux. The experimental data were compared against previous heat transfer correlations. Most correlations failed to predict the experimental data. However, the correlation by Cavallini et al. showed relatively good agreement with experimental data in the microfin tube. Therefore, a new condensation heat transfer correlation is proposed with mean and average deviations of 3.14 and ?7.6?%, respectively.  相似文献   

10.
This study experimentally investigated the flow boiling heat transfer, pressure drop, and flow pattern in a horizontal square minichannel with a hydraulic diameter of 2.0 mm, and the effects of mass flux, vapor quality, heat flux, and refrigerant properties on the flow boiling characteristics were clarified. The heat transfer coefficient and pressure drop of R32 and R1234yf were measured in a mass flux range of 50–400 kgm−2s−1 at a saturation temperature of 15 °C. The flow pattern of the square minichannel outlet was observed and was classified as plug, wavy, churn, and annular flows. The heat transfer coefficients in the square minichannel were larger than those in the circular minichannel with a similar hydraulic diameter at low mass flux conditions. The heat transfer coefficients of R32 indicated higher values compared with those of R1234yf at same mass flux and qualities. An empirical heat transfer model taking into account the forced convection, nucleate boiling, and thin liquid film evaporation was developed for horizontal square and circular minichannels. The frictional pressure drop of R32 was 1.5–2 times higher than that of R1234yf at same mass flux and vapor quality condition, and the effect of channel shape on the frictional pressure drop was small unlike the boiling heat transfer.  相似文献   

11.
The fin efficiency in a heat exchanger element that is a simplification of one row in a tube-and-fin heat exchanger was theoretically examined within wide ranges of the affecting variables: the conventional fin efficiency and the isothermal effectiveness of the heat exchanger. These variables are suggested for use also in the further studies. An analytical solution can be found for the case of a constant heat transfer coefficient. The ambient temperature variation alone decreases the fin efficiency less than 4%. The local heat transfer coefficient obtained from the numerical fluid flow simulations is strongly affected by the fin properties because the thermal boundary conditions for the fluid flow changes. On a poorly conducting fin surface the heat transfer coefficient in front of the fin base is much larger than on an isothermal fin because the heat flux is increasing in the flow direction. At low fin efficiencies this compensates for the decrease in fin efficiency due to ambient temperature variation.  相似文献   

12.
A numerical study has been conducted to examine the heat transfer from a metal foam-wrapped solid cylinder in cross-flow. Effects of the key parameters including the free stream velocity and characteristics of metal foam such as porosity, permeability, and form drag coefficient on heat and fluid flow are examined. Being a determining factor in pressure drop and heat transfer increment, the porous layer thickness is changed systematically to observe that there is an optimum layer thickness beyond which the heat transfer does not improve while the pressure drop continues to increase. This has been verified by the application of Bejan’s Intersection of Asymptotes method. Results have been compared to those of a finned-tube heat exchanger to observe much higher heat transfer rate with reasonable excess pressure drop leading to a higher area goodness factor for metal foam-wrapped cylinder.  相似文献   

13.
Understanding the heat-release effects on the wall heat transfer in turbulent reacting flows, i.e. heat transfer with or without significant density variation, is essential for a wide variety of industrial flows, especially combustion problems. The present study focuses on the wall heat transfer and the near-wall reaction characteristics. The heat-release effects on the wall heat transfer and skin-friction coefficients are investigated using three-dimensional direct numerical simulations of a turbulent reacting wall-jet flow with and without heat release. Reductions in the skin-friction coefficient are observed in the exothermic case, compared to the isothermal one, and the underlying mechanism is explained. The absolute wall heat flux also increases, while the corresponding Nusselt number decreases with increasing heat release. Furthermore, the wall effects on the near-wall average burning rate are assessed. It is found that the isothermal cold wall results in an appreciable decrease of the burning rate in the exothermic cases. We observed indications that the wall increases the chances for the development of the premixed mode and its occurrence is very fast in the wall-normal direction.  相似文献   

14.
Direct contact heat transfer between water and a heat transfer oil was investigated under non-boiling conditions in co-current turbulent flow through a horizontal concentric annulus. The ratio of the inner pipe diameter to the outer pipe diameter (aspect ratio) κ = 0.730−0.816; total liquid velocity (mixture velocity) VT = 0.42−1.1 m/s; inlet oil temperature Toi = 38−94°C; oil volume fraction in the flowing mixture φo = 0.25−0.75 were varied and their effects on the overall volumetric heat transfer coefficient Uv were determined at constant interfacial tension of 48 dynes/cm.

It was found that, in each concentric pipe set, the overall volumetric heat transfer coefficient increased with increasing dispersed phase volume fraction at each constant mixture velocity and reached a maximum at around φo = φw ≈ 0.5. The maximum Uv values increased with increasing total liquid velocity and decreasing aspect ratio of the annulus. The volumetric heat transfer coefficient was also found to increase with increasing inlet oil temperature and increasing total liquid velocity but to decrease with length along the test section keeping all other parameters constant. Empirical expressions for the volumetric heat transfer coefficient were obtained within the ranges of the experimental parameters.  相似文献   


15.
利用格子Boltzmann方法模拟二维水平通道内水的流动沸腾过程,获得不同壁面过热度下流型特点和不同因素对换热过程的影响规律。结果表明,随着壁面过热度升高,流道内流型依次经历从泡状流、弹状流到反环流的转变,平均热流密度和平均换热系数先增大后减小。入口流速降低会使流道内出现受限气泡流,核态沸腾受到抑制。提高入口流速能够有效促进气泡脱离,壁面平均换热系数随入口流速增大而增大,但增长速率有所减小。减小通道宽度有利于汽化现象发生,核态沸腾得到强化,壁面平均换热系数有所提高。  相似文献   

16.
Coiled tubes and nanofludics are two significant techniques to enhance the heat transfer ability of thermal equipments. The forced convective heat transfer and the pressure drop of nanofluid inside straight tube and helical coiled one with a constant wall heat flux were studied experimentally. Distilled water was used as a host fluid and Nanofluids of aqueous TiO2 nanoparticles (50 nm) suspensions were prepared in various volume concentrations of 0.25–2 %. The heat transfer coefficient of nanofluids is obtained for different nanoparticle concentrations as well as various Reynolds numbers. The experiments covered a range of Reynolds number of 500–4,500. The results show the considerable enhancement of heat transfer rate, which is due to the nanoparticles present in the fluid. Heat transfer coefficient increases by increasing the volume concentration of nanoparticles as well as Reynolds number. Moreover, due to the curvature of the tube when fluid flows inside helical coiled tube instead of straight one, both convective heat transfer coefficient and the pressure drop of fluid grow considerably. Also, the thermal performance factors for tested nanofluids are greater than unity and the maximum thermal performance factor of 3.72 is found with the use of 2.0 % volume concentration of nanofluid at Reynolds number of 1,750.  相似文献   

17.
The condensation heat transfer of pure refrigerants, R-22, R-134a and a binary refrigerant R-410A flowing in small diameter tubes was investigated experimentally. The condenser is a countflow heat exchanger which refrigerant flows in the inner tube and cooling water flows in the annulus. The heat exchanger is smooth, horizontal copper tube of 1.77, 3.36 and 5.35 mm inner diameter, respectively. The length of heat exchanger is 1220, 2660 and 3620 mm, respectively. The experiments were conducted at mass flux of 200–400 kg/m2 s and saturation temperature of 40°C. The main results were summarized as follows: in case of single-phase flow, the single-phase Nusselt Number measured by experimental data was higher than that calculated by Gnielinski and Wu and Little correlation. The new single-phase correlation based on the experimental data was proposed in this study. In case of two-phase flow, the condensation heat transfer coefficient of R-410A for three tubes was slightly higher than that of R-22 and R-134a at the given mass flux. The condensation heat transfer coefficient of R-22 showed almost a similar value to that of R-134a. The condensation heat transfer coefficient for R-22, R-134a and R-410A increased with increasing mass flux and decreasing tube diameter. Most of the existing correlations which were proposed in the large diameter tube failed to predict condensation heat transfer. Therefore, the new condensation heat transfer correlation based on the experimental data was proposed in the present study.  相似文献   

18.
在相同的开孔面积和开孔数目前提下,本文数值研究在开孔位置不同时圆缺高度为0.2D(D为折流板直径)的单弓型折流板换热器的壳程换热与流动阻力问题。数值结果表明:在折流板压强高的“高压区”,均匀地开孔对减小换热器壳程压降效果更好,其综合换热性能的性能评价因子E值也更好;在壳程入口速度为0.1m/s时,通过改变开孔位置,壳程压降可优化3%左右。  相似文献   

19.
Injection of sub-millimeter bubbles is considered a promising technique for enhancing natural convection heat transfer for liquids. So far, we have experimentally investigated heat transfer characteristics of laminar natural convection flows with sub-millimeter bubbles. However, the effects of the bubble size on the heat transfer have not yet been understood. The purpose of this study is to clarify the effects of the bubble size on the heat transfer enhancement for the laminar natural convection of water along a vertical heated plate with uniform heat flux. Temperature and velocity measurements, in which thermocouples and a particle tracking velocimetry technique are, respectively used, are conducted to investigate heat transfer and flow characteristics for different bubble sizes. Moreover, two-dimensional numerical simulations are performed to comprehensively understand the effects of bubble injection on the flow near the heated plate. The result shows that the ratio of the heat transfer coefficient with sub-millimeter-bubble injection to that without injection ranges from 1.3 to 2.2. The result also shows that for a constant bubble flow rate, the heat transfer coefficient ratio increases with a decrease in the mean bubble diameter. It is expected from our estimation based on both experimental data and simulation results that this increase results from an increase in the advection effect due to bubbles.  相似文献   

20.
Entropy generation in the flow field subjected to a porous block situated in a vertical channel is examined. The effects of channel inlet port height (vertical height between channel inlet port and the block center), porosity, and block aspect ratio on the entropy generation rate due to fluid friction and heat transfer in the fluid are examined. The governing equations of flow, heat transfer, and entropy are solved numerically using a control volume approach. Air is used as the flowing fluid in the channel. A uniform heat flux is considered in the block and natural convection is accommodated in the analysis. It is found that entropy generation rate due to fluid friction increases with increasing inlet port height, while this increase becomes gradual for entropy generation rate due to heat transfer for the inlet port height exceeding 0.03 m. The porosity lowers entropy generation rate due to fluid friction and heat transfer. The effect of block aspect ratio on entropy generation rate is notable; in which case, entropy generation rate increases for the block aspect ratio of 1:2.  相似文献   