1.
A novel electron paramagnetic resonance (EPR) spectrometer is reported, which has been developed to allow pulsed EPR experiments with high sensitivity and time resolution at a microwave (MW) frequency of 180 GHz (G-band) and wavelengths of approximately 1.6 mm. This corresponds to a magnetic field of about 6.4 T forg ≈ 2 signals. The “hybrid” system architecture combines components of quasioptical as well as conventional MW techniques, making it possible to achieve excellent spectrometer performance with respect to sensitivity and time resolution. Quasioptical MW components have been used to design an MW circulator allowing high sensitivity and low bias operation in the reflection mode. A miniaturized, closed-type cylindrical cavity provides a high sample filling factor and an adequate MW field strength (B1) enhancement and thus permits reasonably short MW pulses (60 ns for a π/2 pulse) even with a moderate MW input power (15 mW at the cavity). Commercial quartz capillaries (up to 0.5 mm internal diameter) can be used as sample holders for a broad range of applications.  相似文献   

2.
An electron paramagnetic resonance (EPR) spectrometer is described which allows for continuous-wave and pulsed EPR experiments at 275 GHz (wavelength 1.1 mm). The related magnetic field of 9.9 T for g approximately 2 is supplied by a superconducting solenoid. The microwave bridge employs quasi-optical as well as conventional waveguide components. A cylindrical, single-mode cavity provides a high filling factor and a high sensitivity for EPR detection. Even with the available microwave power of 1 mW incident at the cavity a high microwave magnetic field B1 is obtained of about 0.1 mT which permits pi/2-pulses as short as 100 ns. The performance of the spectrometer is illustrated with the help of spectra taken with several samples.  相似文献   

3.
A spectrometer specifically designed for systematic studies of the spin dynamics underlying Dynamic Nuclear Polarization (DNP) in solids at low temperatures is described. The spectrometer functions as a fully operational NMR spectrometer (144 MHz) and pulse EPR spectrometer (95 GHz) with a microwave (MW) power of up to 300 mW at the sample position, generating a MW B(1) field as high as 800 KHz. The combined NMR/EPR probe comprises of an open-structure horn-reflector configuration that functions as a low Q EPR cavity and an RF coil that can accommodate a 30-50 μl sample tube. The performance of the spectrometer is demonstrated through some basic pulsed EPR experiments, such as echo-detected EPR, saturation recovery and nutation measurements, that enable quantification of the actual intensity of MW irradiation at the position of the sample. In addition, DNP enhanced NMR signals of samples containing TEMPO and trityl are followed as a function of the MW frequency. Buildup curves of the nuclear polarization are recorded as a function of the microwave irradiation time period at different temperatures and for different MW powers.  相似文献   

4.
Two derivatives of the wideband alternating-phase low-power technique for zero-residual splitting (WALTZ)-4 decoupling sequence for broadband decoupling named WALTZ-4a and WALTZ-4b were compared for their proton decoupling performance in 31P nuclear magnetic resonance (NMR) spectroscopy using a Siemens Magnetom SP 1.5 T whole-body imager. Version WALTZ-4a originally implemented by the manufacturer doubles and triples the transmitter amplitude of the 90° pulse to achieve the 180° and 270° flip angle required for one composite pulse R in the WALTZ sequence. WALTZ-4b follows the sequence reported from Shaka et al. and leaves the transmitter amplitude constant but increases the durations of the 180° and 270° pulses. The decoupling performance of WALTZ-4b is superior because it requires less transmitter power and, therefore, it is advantageous in all in vivo studies where a low specific absorption rate is desired. When WALTZ-4 is used in combination with a surface coil for transmission the theoretically required flip angles cannot be achieved in the entire sensitive volume of the coil. The decoupling performance was therefore investigated at lower and higher flip angles. Again, WALTZ-4b is advantageous and provides, in certain ranges that are off-resonant from the decoupling frequency, a good decoupling quality even for flip angles that are only 60% of the theoretically required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号