首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Poly(N-isopropylacrylamide) (PIPAAm) brush-grafted porous polystyrene beads with variable grafted polymer densities were prepared using surface-initiated atom transfer radical polymerization (ATRP) for applications in thermo-responsive chromatography. Utilization of these grafted beads as a stationary phase in aqueous chromatographic analysis of insulin provides a graft density-dependent analyte retention behavior. The separations calibration curve on PIPAAm-grafted polystyrene was obtained using pullulan standards and exhibited inflection points attributed to analyte diffusion into bead pores and partitioning into grafted PIPAAm brush surfaces. Presence of these inflection points supports a separation mechanism where insulin penetrates pores in polystyrene beads and hydrophobically interacts with PIPAAm brushes grafted within the pores. Control of PIPAAm brush graft density on polystyrene facilitates effective aqueous phase separation of peptides based on thermally modulated hydrophobic interactions with grafted PIPAAm within stationary phase pores. These results indicated that PIPAAm brush-grafted porous polystyrene beads prepared by surface-initiated ATRP was effective stationary phase of thermo-responsive chromatography for aqueous phase peptide separations.  相似文献   

2.
The difficulty of preparing monodisperse lignin fractions on a large scale is a limiting factor in many applications. The present paper addresses this problem by examining the properties and size-exclusion behavior of lignin isolated by the acetosolv pulping process from post-extraction crushed sugarcane bagasse. The isolated lignin was subjected to a solvent pretreatment, followed by preparative gel permeation chromatography fractionation. The fractions were analyzed by high-performance size-exclusion chromatography (HPSEC) and these samples showed a great decrease in polydispersity, compared to the original acetosolv lignin. Several fractions of very low polydispersity, close to unity, were employed as calibration curve standards in HPSEC analysis. This original analytical approach allowed calibration with these lignin fractions to be compared with the polystyrene standards that are universally employed for lignin molecular mass determination. This led to a noteworthy result, namely that the lignin fractions and polystyrene standards showed very similar behavior over a large range of molecular masses in a typical HPSEC analysis of acetosolv lignin.  相似文献   

3.
In this investigation, capillary electrochromatography (CEC) with a novel stationary phase proved useful for the separation of neutral and acidic glycosphingolipids (GSLs). Four different gangliosides, namely G(M1a), G(D1a), G(D1b) and G(T1b), served as the acidic GSLs model solutes. The following four GSLs: galactosylceramide (GalCer), lactosylceramide (LacCer), globotriaosylceramide (Gb3Cer) and globotetraosylceramide (Gb4Cer) served as the typical neutral GSLs. The stationary phase, octadecyl sulfonated silica (ODSS), consisted of octadecyl functions bonded to a negatively charged layer containing sulfonic acid groups. Porous and non-porous ODSS stationary phases were examined. The retention behavior of the acidic and neutral GSLs was examined over a wide range of elution conditions, including the nature of the electrolyte and organic modifier and the pH of the mobile phase. The porous ODSS stationary phase yielded the separation of the four different gangliosides using a hydro-organic eluent of moderate eluent strength whereas the non-porous ODSS stationary phase permitted the separation of the four neutral GSLs with a mobile phase of relatively high eluent strength.  相似文献   

4.
A review is presented on the current state of the art and future trends in the development of sol-gel stationary phases for capillary electrochromatography (CEC). The design and synthesis of stationary phases with prescribed chromatographic and surface charge properties represent challenging tasks in contemporary CEC research. Further developments in CEC as a high-efficiency liquid-phase separation technique will greatly depend on new breakthroughs in the area of stationary phase development. The requirements imposed on CEC stationary phase performance are significantly more demanding compared with those for HPLC. The design of CEC stationary phase must take into consideration the structural characteristics that will provide not only the selective solute/stationary phase interactions leading to chromatographic separations but also the surface charge properties that determine the magnitude and direction of the electroosmotic flow responsible for the mobile phase movement through the CEC column. Therefore, the stationary phase technology in CEC presents a more complex problem than in conventional chromatographic techniques. Different approaches to stationary phase development have been reported in contemporary CEC literature. The sol-gel approach represents a promising direction in this important research. It is applicable to the preparation of CEC stationary phases in different formats: surface coatings, micro/submicro particles, and monolithic beds. Besides, in the sol-gel approach, appropriate sol-gel precursors and other building blocks can be selected to create a stationary phase with desired structural and surface properties. One remarkable advantage of the sol-gel approach is the mild thermal conditions under which the stationary phase synthesis can be carried out (typically at room temperature). It also provides an effective pathway to integrating the advantageous properties of organic and inorganic material systems, and thereby enhancing and fine-tuning chromatographic selectivity of the created hybrid organic-inorganic stationary phases. This review focuses on recent developments in the design, synthesis, characterization, properties, and applications of sol-gel stationary phases in CEC.  相似文献   

5.
High-performance size-exclusion chromatography of some standard proteins, peptides and amino acids on a new hydrophilic packing material obtained by chemical transformation of a cross-linked polystyrene-divinylbenzene copolymer was studied. Columns filled with 4 and 7 micron particles were compared. The influence of the concentration of acetonitrile, isopropanol and trifluoroacetic acid in the mobile phase on the chromatographic performance was investigated. A good linear calibration graph covering the molecular weight range from 200 to 700,000, was obtained under the optimal conditions. The packing material can be used for separations, for molecular weight determinations and for the pre-fractionation of proteins. The high rigidity of the packing material allows relatively high pressures to be used and therefore fast separations to be achieved. The packing material was applied to the chromatography of proteins from beer, bones and milk.  相似文献   

6.
Macroporous, monolithic capillary electrochromatography (CEC) columns, featuring a hydrophobic stationary phase, have been applied to the separations of steroids with good column efficiency. Using isocratic and gradient elution runs, mixtures of neutral or conjugated steroids could be resolved. While dansylated ketosteroids were detectable through laser-induced fluorescence at attomole levels, the CEC columns coupled to electrospray-ion-trap mass spectrometry featured femtomole detection limits.  相似文献   

7.
Most commercially available instruments for capillary electrochromatography (CEC) have a fixed configuration and lack the flexibility to use shorter columns. Applying a blended stationary phase (a phase consisting of a given ratio of bare silica and reversed phase material) can simulate columns of different length in CEC. The goal of this work was to examine the effect of the degree of blending of reversed-phase columns (with bare silica) on the speed of the separation of neutral compounds in CEC. Optimum column packing mixture was determined from the variation of the solute retention factors as a function of the ratios of blending of reversed-phase and bare silica. By adjusting the column composition, solute retention factors and the analysis run time were halved when compared to a pure reversed-phase column of the same length. Stationary phase blending can be considered as an additional parameter to mobile phase variation, column temperature and applied electric field for the optimization of selectivity and analysis time. By adjusting the stationary phase composition, mobile phase composition, column temperature and applied electric field, the analysis run time of neutral components was decreased more than 75% when compared to a separation obtained on neat reversed-phase column of the same dimensions. The linear dependence of the retention factors as a function of the blend ratio (reversed phase/bare silica) offers a framework for designing a “blended” packed capillary column for CEC separations.  相似文献   

8.
Enantioseparations in nonaqueous capillary electrochromatography (CEC) are reported in this study for the first time, using wide-pore aminopropyl silica gel coated with helically chiral poly(diphenyl-2-pyridylmethyl methacrylate) (PDPM) as chiral stationary phase (CSP). The anodic electroosmotic flow (EOF) in a methanolic solution of ammonium acetate was used for the migration of neutral analytes through the packed bed in the capillaries. Four different techniques, high-performance liquid chromatography (HPLC) in common-size columns, capillary HPLC, pressure-assisted CEC and CEC were compared from the viewpoint of separation parameters. The latter three were performed with the same experimental setup, varying the relative contribution of the pressure-driven and the electrically driven flow to the overall mobility of the analyte. Capillary HPLC offers clear advantages compared to enantioseparations in common-size columns. However, for a given particle size of the packing material, CEC was not obviously advantageous compared to pressure-driven separations.  相似文献   

9.
New microporous particles with large pore size (mean pore diameter of 820 nm) are successfully prepared from a mixture of cellulose and konjac glucomannan (RC-KGM3) in 1.5 M NaOH-0.65 M thiourea aqueous solution by coagulating with 5 weight percentage (wt%) CaCl(2), and then 2 wt% HCl aqueous solution. A preparative size-exclusion chromatographic (SEC) column packed with the gel particles is used for the fractionation of a dextran in water. The exclusion limit and fractionation range of the stationary phase are molecular masses of 125 yen 104 g/mol and 5.6 yen 104 to 125 yen 104 g/mol, respectively. The dextran [dextran 50, weight-average molecular mass (M(w)) = 40.1 yen 104 g/mol, polydispersity index (d) = 3.5] is fractionated by the preparative SEC column to obtain six fractions, and four of them are refractionated twice by the same preparative SEC column. The refractionated samples F-3-3 and F-4-3 are characterized by analytical SEC combined with laser light scattering and light scattering to obtain M(w) of 91.8 and 61.9 yen 104 g/mol, as well as d of 1.3 and 1.4, respectively. The results indicate that the fractions having narrow molecular mass distribution are satisfactorily prepared with the SEC column. The described SEC column can be successfully used to fractionate polymers in aqueous solution.  相似文献   

10.
A macroporous, spherical, 7 μm, polystyrene–divinylbenzene (PS–DVB), reversed-phase adsorbent (PRP-1) was evaluated as a stationary phase for the capillary electrochromatographic (CEC) separation of neutral, acidic, and basic analytes of pharmaceutical interest. Electroosmotic flow (EOF) for a PRP-1 packed capillary is nearly constant over the pH 2 to 10 range and is higher than for a silica-based C18 packed capillary on the acidic side. EOF increases with an increase in buffer acetonitrile concentration or as applied potential increases. As analyte hydrophobicity increases, analyte retention and migration time increases. Increasing buffer acetonitrile concentration reduces analyte partitioning with the PS–DVB stationary phase and analyte retention and migration time decreases. When exchange sites are present on the PS–DVB copolymer, EOF (EOF is reversed for the anion-exchanger) increases as the exchange capacity increases. An increased exchange capacity also reduces partitioning of the analyte with the PS–DVB matrix and analyte retention and migration time decrease. Because of excellent stability in an acid environment, the PRP-1 packed capillary can be used in strong acid buffer solution and weak acid and base analytes depending on pKa values can be separated as neutral species and cations, respectively. CEC separations on a PRP-1 capillary of neutral steroids, weak base pharmaceuticals (separation as cations), purines and pyrimidines (as cations), fatty acids (as undissociated species), and sulfa derivatives (as cations) are described. Efficiency for the PRP-1 packed capillary for acetone or thiourea as the analyte is about 6·104 plates m−1.  相似文献   

11.
Our understanding of the nature of solute retention in size-exclusion chromatography (SEC) is predicated upon an equilibrium, entropy-controlled, size-exclusion mechanism. The entropic nature of the separation depends, in turn, upon the solute distribution coefficient (K(SEC) being at (or close to) thermodynamic equilibrium. Classic experiments to confirm this assumption were performed over thirty years ago. Here, we combine information obtained from both flow and static mixing SEC experiments to show that the solute distribution in SEC is in thermodynamic equilibrium over a molar mass range extending one order of magnitude higher than previously measured (from 2 x 10(3) to 1.1 x 10(6) Da) using crosslinked polystyrene packing material of identical pore size (10(4) A). The differences between our observations and previous ones conducted over three decades ago are ascribed, principally, to advances in stationary phase synthesis and column technology for SEC in particular and, secondarily, to improvements in the performance of the various instrumental components of liquid chromatographic systems in general.  相似文献   

12.
Summary Highly efficient and fast exclusion-chromatographic separations of proteins are possible on chemically-modified, silica stationary phases. By optimizing the pH and the ionic strength of the aqueous eluent secondary interactions of the samples with surface groups can be excluded. Bonded propylamide groups proved to possess optimum properties for exclusion chromatography. With other functional groups adsorption effects cannot be excluded totally. The optimum pore size distribution for protein separation up to relative molecular masses of 500,000 daltnons is between 10nm and 50nm. With these silica-based phases the pore size distribution, the pore volume and the packing characteristics are independent of the eluent, therefore the same column can be used with aqueous as well with organic eluents. It is possible to correlate the elution volume (molecular size) of proteins with those of polystyrene standars. The recovery of the proteins and their biological activity has always been better than 90%. The potentialities of adsorption chromatography of proteins on chemically-bonded stationary plases with different functional groups are demonstrated.  相似文献   

13.
Different models have been described in the literature to evaluate the total porosity of CEC columns: gravimetric, flow as well as conductivity-based methods. In this study, these models have been compared for two kinds of CEC columns: two mixed-mode silica particle stationary phases and different monolithic columns (acrylate or polystyrene divinylbenzene-based). The total porosities measured from the conductivity-based methods were lower than the total column porosities obtained by gravimetric or flow methods for all the investigated columns while the wide distribution of observed values shows that conductivity-based methods discriminate columns more efficiently with very different properties. We propose a conductivity-based method taking into account the actual length proposed by Horvath, to evaluate what we call an "actual electrokinetic" porosity (AEP). This parameter, based on electrokinetic theory only, affords the most consistent evaluation of porosity under experimental CEC conditions for the packed- and acrylate-based monolithic columns. To illustrate the potential of AEP and actual EOF for the estimation of the performances of a CEC system (stationary and mobile phases) we studied the influence of the mobile-phase composition on these parameters for CEC separations with an ammonium embedded packed stationary phase. The AEP and the actual electroosmotic mobility should allow a better understanding of the perfusive EOF and stationary-phase wettability. For neutral compounds (substituted phenols), AEP evaluation allowed us to predict the mobile-phase conditions able to enhance the efficiency while both AEP and actual EOF had to be considered in the case of peptide analysis.  相似文献   

14.
Size-exclusion chromatography has been developed for the separation of large biological molecules including proteins, polymers, peptides, nucleic acids, and polysaccharide according to their molecular size. This study determined the retention factors for dextran (5, 25, 50, 270, 670, and 1100?kDa) and polysaccharides, such as fucoidan, alginic acid, and laminarin, in the size-exclusion chromatography stationary phase. In addition, the molecular weights and retention factor of three polysaccharides were calculated from the dextran standard curve. The largest retention factor was 4.26 using the size-exclusion chromatography columns (5?kDa dextran). The molecular weights of fucoidan, alginic acid, and laminarin were determined to be 250, 200, and 5 to 64?kDa, respectively.  相似文献   

15.
Since some metal-organic cages (MOCs) have been synthesized in past several years, the applications of MOCs such as drug delivery, molecular recognition, separation, catalysis, and gas storage, etc. have been witnessed with a significant increase. However, to the best of our knowledge, so far no one has used MOCs as chiral stationary phase to separate chiral compounds in CEC. In this study, three MOCs were developed as the stationary phase for CEC separation of enantiomers. The MOCs coated capillary column showed good chiral recognition ability for some chiral compounds, including amine, alcohols, ketone, etc. The influence of buffer concentration, applied voltage, pH of buffer solution on the chiral separations was also investigated. The RSDs of run-to-run, day-to-day, and column-to-column for retention time were 2.1-4.67%, 1.2-4.36%, and 3.62-6.43%, respectively. This work reveals that the chiral MOCs material is feasible for the enantioseparation in CEC.  相似文献   

16.
Li Y  Xiang R  Horváth C  Wilkins JA 《Electrophoresis》2004,25(4-5):545-553
A new kind of monolithic capillary column was prepared for capillary electrochromatography (CEC) with a positively charged polymer layer on the inner wall of a fused-silica capillary and a neutral monolithic packing as the bulk stationary phase. The fused-silica capillary was first silanized with 3-glycidoxypropyltrimethoxysilane (GPTMS). Polyethyleneimine (PEI) was then covalently bonded to the GPTMS coating to form an annular positively charged polymer layer for the generation of electroosmotic flow (EOF). A neutral bulk monolithic stationary phase was then prepared by in situ copolymerization of vinylbenzyl chloride (VBC) and ethylene glycol dimethacrylate in the presence of 1-propanol and formamide as porogens. Benzyl chloride functionalities on the monolith were subsequently hydrolyzed to benzyl alcohol groups. Effects of pH on the EOF mobility of the column were measured to monitor the completion of reactions. Using a column with this design, we expected general problems in CEC such as irreversible adsorption and electrostatic interaction between stationary phase and analytes to be reduced. A peptide mixture was successfully separated in counter-directional mode CEC. Comparison of peptide separations in isocratic monolithic CEC, gradient HPLC and capillary zone electrophoresis (CZE) indicated that the separation in CEC is governed by a dual mechanism that involves a complex interplay between selective chromatographic retention and differential electrophoretic migration.  相似文献   

17.
New composite membranes based on commercial perfluorinated Nafion-115 membrane and cross-linked sulfonated polystyrene were synthesized and investigated. The membranes were prepared by radical polymerization of styrene in the presence of a cross-linking agent divinylbenzene in Nafion polymer matrix and subsequent sulfonation of formed polystyrene. The membranes containing approximately 5 and 10 wt % of cross-linked polystyrene with ion-exchange capacity of 1.1 to 1.3 mg-eq/g were obtained. Modification with sulfonated polystyrene leads to an increase in the moisture content and proton conductivity of membranes in the humidity range of 15 to 100 RH.  相似文献   

18.
A novel silica monolithic stationary phase functionalized with 3-(2-aminoethylamino)propyl ligands for pressurized CEC has been presented. The monolithic capillary columns were prepared by a sol-gel process in 75 microm id fused-silica capillaries and followed by a chemical modification. The diamino groups on the surface of the stationary phase are meant to generate the chromatographic surface and a substantial anodic EOF as well as to provide electrostatic interaction sites for charged solutes. The electrochromatographic characterization and column performance were evaluated by a variety of neutral and charged solutes. It was observed that the anodic EOF for the diamine-bonded monolith was greatly affected by the reaction time with 3-(2-aminoethylamino)propyltrimethoxysilane and the PEG amount in the sol-gel reaction mixture in addition to the mobile phase conditions. The monolithic stationary phase exhibited hydrophilic interaction chromatographic behavior toward neutral solutes. Good separations of various solutes including phenols, nucleic acid bases, nucleosides and nucleotides were achieved under different experimental conditions. Fast and efficient separations were obtained with high plate counts reaching more than 130,000 plates/m.  相似文献   

19.
Capillary electrochromatography (CEC) using polymer-based monolithic stationary phase has been developed as a promising method for the determination of lignans of Schisandra chinensis. The columns were prepared by in situ copolymerisation of acrylamide, N,N'-methylenebisacrylamide, vinylsulfonic acid and lauryl acrylate in presence of poly(ethylene glycol) as a porogenic agent. The columns [33 cm (24.5 cm effective length) x 75 microm I.D.] were successfully used to analyse and quantify the major lignans in extract of the seeds of Schisandra chinensis. Good separations were achieved in less than 35 min. The calibration graphs were linear in the range 0.025-1.0 mg/ml of given lignan with correlation coefficients between 0.9951 and 0.9996. The inter-day reproducibility of the peak area were below 3.9% and the inter-day reproducibility of the migration time were below 4.2%. The results of quantitative CEC analyses were compared with those obtained by reversed-phase HPLC, the levels of schizandrin, gomisin A, gomisin N and wuweizisu C determined by CEC were in a good agreement with those determined by HPLC.  相似文献   

20.
A new method for the estimation of the weight-to-number-average molecular-weight ratio, Mw/Mn of polymers with a narrow molecular-weight distribution, approximated by log-normal distribution, is proposed using size-exclusion chromatography (SEC) with concentration and light-scattering detectors. From experimental data, the Mw/Mn ratios are calculated by two procedures: one using the concentration and light-scattering elution curve for the polymer measured, and the other based on the concentration elution curve and calibration line for a wide range of molecular masses. An iteration method has been developed making the two Mw/Mn ratios converge. The method was applied to a series of narrow molecular-weight distribution polystyrene standards.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号