 共查询到20条相似文献,搜索用时 0 毫秒
1.
This paper reports two highly efficient liquid chromatography-mass spectrometry (LC-MS) methods for the screening of anabolic steroids, corticosteroids, and acidic drugs for the purpose of doping control in equine sports. Sample extraction was performed using a mixed-mode C8-SCX solid-phase extraction (SPE) cartridge. The first eluted fraction (acidic/neutral fraction) was base-washed and the resulting organic extract was used for the screening of anabolic steroids and corticosteroids by LC-MS using multiple reaction monitoring (MRM) in the positive electrospray ionisation (ESI) mode. The remaining aqueous extract was re-adjusted to pH 6 and acidic drugs were recovered by liquid/liquid extraction. Detection was again achieved using LC-MRM but in the negative ESI mode. A total of 40 anabolic steroids and corticosteroids, and over 50 acidic drugs, including some cyclooxygenase-2 (COX-2) inhibitors, oxicams, anti-diabetics, sedatives, diuretics and Delta(9)-tetrahydro-11-norcannabinol-9-carboxylic acid, could be covered by the two LC-MS methods. Both methods utilized a high efficiency reversed-phase column (3.3 cm L x 2.1 mm I.D. with 3 microm particles) coupled with a fast-scanning triple-quadrupole mass spectrometer to achieve fast turnaround times. The overall turnaround times for both methods were 10 min, inclusive of post-run and equilibration times.  相似文献   

2.
Wang X  Zhao T  Gao X  Dan M  Zhou M  Jia W 《Analytica chimica acta》2007,594(2):265-273
A rapid analytical method for quantifying 17 ginsenosides in rat urine by ultra performance liquid chromatography (UPLC) coupled to electrospray ionization mass spectrometry (ESI-MS) is described. All analytes were extracted by solid-phase extraction optimized to obtain good recovery and quantified using digoxin as an internal standard. ESI-MS was optimized for different cone voltages at positive ionization mode to allow simultaneous analysis of all analytes in a relatively short time. Qualitative methodological considerations, including the linear range, precision, limit of quantification, limit of detection, recovery and sensitivity are also provided.  相似文献   

3.
An improved screening method for beta-blockers in urine is proposed, involving enzymatic hydrolysis, solid-phase extraction and capillary gas chromatography-mass spectrometry. Several extraction methods for beta-blockers, such as conventional liquid-liquid and solid-phase extraction procedures, have been evaluated for at least eight beta-blockers. Additionally, the gas chromatographic properties and mass fragmentation of the trimethylsilyl-trifluoroacetyl, trifluoroacetyl and cyclic n-butylboronate derivatives of beta-blockers have been compared and evaluated with respect to their efficiency for screening urine. The resulting screening method proved to be a specific and sensitive procedure, enabling these analytes to be detected and identified up to 48 h after the administration of a dosage, usually encountered in doping cases.  相似文献   

4.
A novel solid-phase extraction (SPE) method was developed for extraction and cleanup of 11-nor-9-carboxy-delta9-tetrahydrocannabinol (THC-COOH), the major metabolite of the active principle of marijuana, delta9-tetrahydrocannabinol, from urine samples. The protocol utilizes a polymeric mixed-mode cationic sorbent, Strata-X-C, which exhibits strong retention for the metabolite facilitating a more rigorous organic wash to eliminate matrix components/endogenous materials. Acetonitrile containing acetic acid was used as the elution solvent and is compatible with both LC-MS and GC-MS modes of analysis. The hydrophobic retention of Strata-X-C was demonstrated to be higher than a neutral polymeric sorbent, Strata-X, of the same backbone but devoid of the cation-exchange moiety (sulfonic acid), by LC studies employing homologous paraben probes. Simultaneously, the polar (non-ionic) interaction capability of Strata-X-C is also greater than that of Strata-X, as assessed through regioisomeric nitrophenol probes. These two features enable the metabolite to be retained strongly on Strata-X-C. Good linearity and precision was obtained for THC-COOH by GC-MS analysis of its trimethylsilyl derivative in the range 1-50 ng. A simplified room temperature instantaneous derivatization procedure was developed that is suitable for high-throughput screening of THC-COOH.  相似文献   

5.
Mequitazine has been found to be extractable from human plasma samples using MonoTip C18 tips, inside which C18-bonded monolithic silica gel was fixed. Human plasma (0.1 mL) containing mequitazine and cyproheptadine as an internal standard (IS) was mixed with 0.4 mL of distilled water and 25 μL of 1 M potassium phosphate buffer (pH 8.0). After centrifugation of the mixture, the supernatant fraction was extracted to the C18 phase of the tip by 25 repeated aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C18 phase were then eluted with methanol by five repeated aspirating/dispensing cycles. Without evaporation and reconstitution, the eluate was injected into a gas chromatograph injector and detected by a mass spectrometer with selected ion monitoring in the positive-ion electron impact mode. The separation of mequitazine and the IS from each other and from impurities was generally satisfactory using a DB-1MS capillary column (30 m × 0.32 mm i.d., film thickness 0.25 μm). The recoveries of mequitazine and the IS spiked into plasma were more than 90.0%. The regression equation for mequitazine showed excellent linearity in the range of 0.2-200 ng 0.1 mL−1, and the detection limit was 0.05 ng 0.1 mL−1of plasma. The intra-day and inter-day coefficients of variation for mequitazine in human plasma were not greater than 8.16 and 9.24%, respectively. Accuracy for the drug was in the range of 90.0-97.4%. The data obtained from determination of mequitazine in human plasma after oral administration of the drug are also presented.  相似文献   

6.
林兴桃  王小逸  赵靖强 《色谱》2016,34(5):528-532
建立了固相萃取-气相色谱-质谱测定尿液中邻苯二甲酸单酯和双酯的分析方法。尿液经 β-葡萄糖苷酸酶酶解后进行固相萃取净化,用乙腈、乙酸乙酯和乙醚-正己烷(1: 19, v/v)分别洗脱,合并洗脱液,氮气吹干后,用N,O-双三甲基硅基三氟乙酰胺(BSTFA)对邻苯二甲酸单酯进行硅烷化处理,使用气相色谱-质谱法检测。邻苯二甲酸单酯和双酯的线性范围为5~1000 μ g/L,检出限为0.3~1.1 μ g/L,回收率为77.9%~97.7%,相对标准偏差为3.7%~10.9%。应用该方法对50份尿液进行检测,检出邻苯二甲酸二(2-乙基己基)酯(DEHP)等7种邻苯二甲酸单酯和双酯类物质,平均质量浓度为6.0~142.7 μ g/L。该方法准确、可靠、灵敏度高,适用于尿液中邻苯二甲酸单酯和双酯的同时测定。  相似文献   

7.
A rapid, sensitive and automated in-tube solid-phase microextraction-liquid chromatography-mass spectrometry (in-tube SPME/LC-MS) method was developed for the analysis of ten antidepressants in urine and plasma. A hybrid organic-inorganic silica monolith with cyanoethyl functional groups was prepared and used as a sorbent for in-tube SPME. Integration of the sample extraction, LC separation and MS detection into a single system permitted direct injection of the diluted urine or plasma after filtration. Under the optimized conditions, good extraction efficiencies for the targets were obtained with no matrix interference in the subsequent LC-MS. Automation of the sampling, extraction and separation procedures was realized under the control of a program in this study. The total process time was 30 min and only 30 μL of urine or plasma was required in one analysis cycle. Good linearities were obtained for ten antidepressants with the correlation coefficients (R) above 0.9933. The limits of detection (S/N=3) for ten antidepressants were found to be 0.06-2.84 ng/mL in urine and 0.07-2.95 ng/mL in plasma. The recoveries of antidepressants spiked in urine and plasma were from 75.2% to 113.0%, with relative standard deviations less than 16.5%. The developed method was successfully used to analyze urine sample from ageing patients undergoing therapy with antidepressants.  相似文献   

8.
A liquid chromatography-mass spectrometry (LC-MS) method was developed for the determination of five macrolides in natural water samples, using kitasamycin as surrogate. The macrolides were extracted from water samples using Oasis HLB cartridges. Pre-concentration factors up to 250 were obtained. Separation was carried out in an end-capped silica-based C18 column and mobile phases consisting of water/acetonitrile mixtures containing ammonium acetate. Detection was performed by mass spectrometry with a single quadrupole and a triple quadrupole using an electrospray interface. The quality parameters obtained with these two approaches were compared. The detection limits of the whole process were about 1 ng l(-1). The recoveries from 250 ml of water samples spiked at 25-125 ng l(-1) level were in the range 85-115%, except for azithromycin levels, which were around 70%. Erythromycin-H2O, clarithromycin and azithromyzin were found, at the sub ng l(-1) level, in the studied rivers.  相似文献   

9.
Liu AC  Lin TY  Su LW  Fuh MR 《Talanta》2008,75(1):198-204
An online solid-phase extraction (SPE) liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) method for the determination of buprenorphine (Bup), norbuprenorphine (nBup), buprenorphie-3-beta-d-glucuronide (Bup-3-G) and norbuprenorphie-3-beta-d-glucuronide (nBup-3-G) in human urine was developed and validated. A mixed mode SPE column with both hydrophilic and lipophilic functions was used for online extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. Buprenorphine-D(4) (Bup-D4) and norbuprenophine-D3 (nBup-D3) were used as internal standards for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve. Identification and quantification were based on the following transitions: m/z 468-->414 for Bup, m/z 414-->364 for nBup, m/z 644-->468 for Bup-3-G and m/z 590-->414 for nBup-3-G, respectively. Good recoveries from 93.6% to 102.2% were measured and satisfactory linear ranges for these analytical compounds were determined. Minimal ion suppression effect (approximately 7% response decrease) was determined. Intra-day and inter-day precision showed coefficients of variance, CV, ranged from 3.3% to 10.1% and 4.4% to 9.8%, respectively. Accuracy ranging from 97.0% to 104.0% was determined. The applicability of this newly developed method was demonstrated by analyzing human urine samples from the patients in Bup treatment program for therapeutic monitoring purpose.  相似文献   

10.
The aim of this work is to established methods for determination of quinolones (ciprofloxacin, danofloxacin, enrofloxacin, difloxacin and flumequine), regulated by European Union, and sarafloxacin in turkey muscle. An experimental design has been applied for the optimization of the factors that influence the extraction of quinolones from turkey muscle in order to determine the experimental conditions for their extraction with high recoveries. Liquid chromatography with ultraviolet detection (LC-UV), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography tandem mass spectrometry (LC-MS/MS) have been used for the simultaneous quantification of quinolones antibiotics in turkey muscle. The proposed methods have been validated according to the Food Drugs Administration guideline and presents the limit of quantification below the maximum residue limits established by the European Union for quinolones in turkey muscle. The methods developed have been applied to quantification of enrofloxacin and its main metabolite ciprofloxacin in samples of turkey muscle obtained from animals treated with enrofloxacin.  相似文献   

11.
A method for the simultaneous determination of two biocidal quaternary ammonium compounds; didecyldimethylammonium chloride (didecyldimethyl quat) and dodecylbenzyldimethylammonium chloride (benzyl quat), in seawater by solid phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) was developed. The optimised procedure utilised off-line extraction of the analytes from seawater using polymeric (Strata-X) SPE cartridges. Recoveries ranged from 80 to 105%, with detection limits at the low parts-per-trillion (ng/l) level for both analytes. To demonstrate sensitivity, environmental concentrations were measured at three different locations along the North East coast of England with measured values in the range 120-270ng/l.  相似文献   

12.
Dextromethorphan was extracted from human plasma samples (100 μL) using MonoTip C18 tips, which are packed with C18-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 μL of distilled water and 50 μL of 1 mol/L glycine–sodium hydroxide buffer (pH 10). The mixture was extracted to the C18 phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C18 phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 μm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug.  相似文献   

13.
Little is known about the contamination level of antibiotics in swine wastewater in China. The highly complex matrix of swine wastewater, which generally has a chemical oxygen demand (COD) concentration as high as 15,000 mg/L, makes it difficult to detect antibiotics at trace levels. In this work, a highly selective and sensitive analytical method was developed for simultaneous determination of three classes of commonly used veterinary antibiotics including five sulfonamides, three tetracyclines and one macrolide in swine wastewater using solid-phase extraction (SPE) and liquid chromatography-mass spectrometry (LC-MS). The method detection limits (MDL) in the swine wastewater were determined to be between 5 and 91 ng/L, depending on specific antibiotics. Except sulfamethizole, all the other eight antibiotics were detected in the swine wastewaters collected from three concentrated swine feeding plants located in the Beijing (China) area, showing a concentration range of 0.62-32.67 microg/L. These results reveal the representative concentration levels of selected antibiotics in the swine wastewaters of Beijing area.  相似文献   

14.
A method was developed for the determination of benzothiazoles from municipal wastewater, which may originate from their use as corrosion inhibitors, vulcanization accelerators or fungicides. Extraction is performed by SPE using a polymeric sorbent, followed by LC-MS analysis with electrospray ionization. Due to the diversity of the analytes, two LC-MS runs are required: 2-aminobenzothiazole, benzothiazole and 2-methylthiobenzothiazole are detected in the positive ion mode, while benzothiazole-2-sulfonic acid (BTSA), 2-mercaptobenzothiazole and 2-hydroxybenzothiazole are determined in the negative ion mode. Limits of quantification range from 20 to 200 ng/L in treated wastewater. Reliable quantification with R.S.D.s below 25% is achieved by standard addition in a limited number of samples of each sample series. A significant reduction of matrix effects in positive electrospray ionization is achieved by reducing the flow directed into the ESI-interface. When applied to untreated municipal wastewater most analytes were found at concentrations in the high ng/L- to low microg/L-range with the most polar BTSA being the dominant compound of this class. Removal of benzothiazoles in biological wastewater treatment appears to be limited.  相似文献   

15.
高吭  刘雅珣  柯威  刘凯  倪浏阳  陶涛 《色谱》2020,38(11):1348-1354
公安机关用胶体金尿检法对海洛因滥用者的检测常常受到阿片类镇咳药的干扰,使用传统液-液提取法进行实验室检验,操作效率低,灵敏度不高,无法满足公安机关打击涉毒案件的需要。为此,该研究建立了尿液中吗啡、O6-单乙酰吗啡、可待因和乙酰可待因4种阿片类物质的固相萃取和衍生化技术结合气相色谱-质谱联用(GC-MS)同时检测方法。尿样用磷酸盐缓冲液调节至pH=6后,经MCX固相萃取柱净化,用N-甲基-N-(三甲基硅烷基)三氟乙酰胺(MSTFA)对吗啡、O6-单乙酰吗啡、可待因进行衍生化,供GC-MS检测。考察了上样和洗脱流速、淋洗液中甲酸体积分数、洗脱液中氨水体积分数、3%(v/v)甲酸甲醇淋洗液体积和固相萃取柱吹干时间对萃取效果的影响。确定上样和洗脱流速1.0 mL/min,淋洗液中甲酸体积分数3%,洗脱液中氨水体积分数5%, 3%(v/v)甲酸甲醇淋洗液体积1 mL,吹干时间1 min为最佳条件。在此条件下,4种阿片类物质在0.02~0.8μg/mL范围内线性关系良好(r2≥0.998),检出限(LOD)为0.001 6~0.00...  相似文献   

16.
17.
A liquid chromatography-mass spectrometry (LC-MS) method for the identification and quantification of chlormequat (CQ) and mepiquat (MQ) in source waters with high sensitivity and specificity was established using WCX cartridges (150 mg/6 mL) for pre-concentration of the samples and using the CAPCELL PAK CR 1:4 (2.0 mm × 150 mm 5 μm, SCX:C18 = 1:4) column containing strong cationic exchange resins and C18 for separation. The method could solve the problem for pre-concentrating ionic compounds from water samples and avoid the MS instrument fouling problem accompanied with the use of ion-pair reagents. After the optimization of analytical conditions, quantification was achieved in the positive electrospray ionization mode using selected ion monitoring. The samples were analyzed with multi-channel mode with quantification performed at 30 V cone voltage to ascertain the sensitivity and qualitative analysis performed at 60 V cone voltage simultaneously. The method detection limits (MDLs) of CQ and MQ in source water were determined to be 14 and 22 ng L−1. Finally, the method was used to quantify CQ and MQ in several source waters, which gave a level ranging from below the quantitation limit to 28 ng L−1.  相似文献   

18.
A method for the simultaneous extraction of four tricyclic antidepressants from human plasma samples using pipette tip SPE with MonoTip C(18) tips is presented. Human plasma (0.1 mL) containing four tricyclic antidepressants (amitriptyline, amoxapine, imipramine, and trimipramine) and an internal standard (IS), protriptyline, was mixed with 0.4 mL of distilled water and 100 microL 1 M NaOH solution. After centrifugation of the mixture, the supernatant was extracted to the C(18) phase of the tip by 20 repeated aspirating/dispensing cycles using a manual micropipettor. The analytes retained in the tip were eluted with methanol by five repeated aspirating/dispensing cycles. Without evaporation and reconstitution, the eluate was directly injected into a gas chromatograph injector and detected by a mass spectrometer with SIM in the positive-ion electron impact mode. Recovery of the four antidepressants and IS spiked into human plasma was 80.2-92.1%. The regression equations for the four antidepressants showed excellent linearity in the range of 0.2-40 ng/0.1 mL. LODs and LOQs for the four drugs were 0.05-0.2 ng/0.1 mL and 0.2-0.5 ng/0.1 mL, respectively. Intra- and interday CVs for the four drugs in plasma were no greater than 9.5%.  相似文献   

19.
Prostanoids are potent biologically active lipid molecules demanding for analysis methods combining precision, sensitivity and high-throughput for pharmacological and clinical applications. The present research describes the development and validation of an on-line automated method based on solid-phase extraction liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) for the quantification of prostanoids in human serum. This approach overcomes the main limitation of previous methods involving manual protocols, such as analyte losses, metabolites degradation and time-consuming protocols, are minimized. Human serum (100 μL) was directly injected into an automatic solid-phase extraction workstation for cleanup and preconcentration of the target metabolites. The eluate was on-line transferred to a reversed-phase analytical column for chromatographic separation prior to mass spectrometry detection in selected reaction monitoring mode. The detection limits for the target analytes ranged from 2.3 to 63.3 pg on column. The precision (expressed as relative standard deviation) was within 3.30 and 6.15% for repeatability and from 4.16 to 11.11% for within-laboratory reproducibility. Accuracy was evaluated with spiked and non-spiked serum samples to estimate concentration differences that could be affected by matrix effects or inefficient SPE performance. Accuracy, estimated as recovery factor, was from 87.7 to 100% for the target compounds. The proposed method is reliable and has an excellent potential for high-throughput use in both clinical and research laboratories by minimizing analyst intervention.  相似文献   

20.
An optimisation of derivatisation methods for the simultaneous determination of endocrine disrupting chemicals (EDCs) in water by solid-phase extraction (SPE) gas chromatography-mass spectrometry (GC-MS) was developed in this study. Seven highly potent EDCs including 17β-estradiol (E2), estrone (E1), 16α-hydroxyestrone, 17α-ethynylestradiol (EE2), bisphenol A, 4-nonylphenol and 4-tert-octylphenol were selected as the target compounds. The SPE technique, followed by the derivatisation with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) was used for the extraction recoveries of compounds from water and effluent samples. The stability of the silylation derivatives under different reaction conditions was investigated. The combined use of BSTFA and pyridine as derivatisation reagents, together with the use of hexane as the final solvent, was preferred in order to generate more stable derivatives of EDCs. The relative response factor (RRF) of all derivatives except that of EE2 was stable 120 h after derivatisation. The addition of pyridine as derivatisation reagent with BSTFA can prevent the conversion of EE2 to other products during the reaction. Several parameters that may affect the recovery of EDCs, such as the SPE flow rate, and water properties including aquatic colloid content and surfactant concentration were tested. The results showed that the flow rate (1-25 mL min−1), colloid concentration (0-50 mg L−1) and surfactants concentration (0-10 μg L−1) did not cause significant decrease in the EDCs recovery.  相似文献   