1.
We have recently proposed a new magnetic resonance spectroscopic imaging (MRSI) technique called wavelet encoding spectroscopic imaging (WE-SI), and described its implementation on a clinical 1.5?T scanner. This technique is proposed as an alternative to chemical shift imaging (CSI), to decrease acquisition time, and voxel contamination. The proposed method is implemented here on a clinical 3?T scanner. Phantom and in vivo studies are chosen to validate the technique at higher field, as well as to fully explore the usefulness of this technique, and find its niche of application in the chain of existing MRSI techniques. In wavelet encoding, a set of dilated and translated wavelets are used to span a localized space by dividing it into a set of sub-spaces with pre-determined sizes and locations. Due to their simple shapes, Haar wavelets are chosen. They are represented in the modified PRESS sequence by the selective excitation and refocusing radio-frequency (RF) pulses. The wavelets dilation and translation are achieved by changing the strength of the localization gradients and frequency shift of the RF pulses, respectively. Data acquisition time is reduced using the minimum recovery time when successive MR signals from adjacent sub-spaces are collected. The results obtained at 3?T confirm those obtained at 1.5?T, and demonstrate that despite the low signal-to-noise ratio, the proposed WE-SI provides accurate results and reduces both voxel contamination and acquisition time as compared to CSI. This applies especially in the small field-of-view regime where only a small number of voxels is required.  相似文献   

2.
Sensitivity-encoded phase undersampling has been combined with simultaneous slice excitation to produce a parallel MRI method with a high volumetric acquisition acceleration factor without the need for auxiliary stepped field coils. Dual-slice excitation was produced by modulating both spin and gradient echo sequences at +/-6 kHz. Frequency aliasing of simultaneously excited slices was prevented by using an additional gradient applied along the slice axis during data acquisition. Data were acquired using a four-channel receiver array and x4 sensitivity encoding on a 1.5 T MR system. The simultaneous parallel inclined readout image technique has been successfully demonstrated in both phantoms and volunteers. A multiplicative image acquisition acceleration factor of up to x8 was achieved. Image SNR and resolution was dependent on the ratio of the readout gradient to the additional slice gradient. A ratio of approximately 2:1 produced acceptable image quality. Use of RF pulses with additional excitation bands should enable the technique to be extended to volumetric acquisition acceleration factors in the range of x16-24 without the SNR limitations of pure partially parallel phase reduction methods.  相似文献   

3.
The radio frequency (RF) slice profile effects on T1 and T2 estimation in magnetic resonance fingerprinting (MRF) are investigated with respect to time-bandwidth product (TBW), flip angle (FA) level and field inhomogeneities. Signal evolutions are generated incorporating the non-ideal slice selective excitation process using Bloch simulation and matched to the original dictionary with and without the non-ideal slice profile taken into account. For validation, phantom and in vivo experiments are performed at 3T. Both simulations and experiments results show that T1 and T2 error from non-ideal slice profile increases with increasing FA level, off-resonance, and low TBW values. Therefore, RF slice profile effects should be compensated for accurate determination of the MR parameters.  相似文献   

4.
5.
雒媛  朱凯然 《波谱学杂志》2020,37(4):515-523
在核四极矩共振(NQR)领域,射频激励脉冲信号的优劣对NQR响应信号有重要影响.针对常规方法中射频激励脉冲参数不可控的问题,本文基于32位闪存微型控制器STM32和直接数字频率合成(DDS)芯片AD9910设计了一种相位可控激励脉冲发生器.采用STM32控制AD9910产生波形参数(脉冲宽度、脉冲间隔、脉冲个数和共振频率等)可控的射频激励脉冲,利用LabVIEW软件平台设计脉冲参数设置界面,并建立计算机与微控制器通信,实现波形参数的精确优化控制.实验结果表明,该方法实现了相位可控的NQR激励脉冲序列,可为后续NQR信号检测提供有效激励源.  相似文献   

6.
PURPOSE: Metallic implants cause enlarged artifacts in magnetic resonance (MR) images at higher magnetic fields, B0, due to their magnetic susceptibility. Interactions of conductive material with radio frequency (RF) pulses also change for higher field strengths, B0, due to the frequency dependence of resonance conditions. Systematic measurements on commercial aneurysm clips and simplified copper models were performed in order to investigate both phenomena at 1.5 and 3 T. MATERIALS AND METHODS: Six different commercial aneurysm clips made of titanium, straight copper wires and bent copper models were examined in Gd-DTPA-doped water. RF-related effects were measured by adapted 2D and 3D spin-echo sequences. For reliable differentiation from susceptibility-related effects, variable transmitter voltages were applied. In addition, RF-induced heating was controlled by an infrared (IR) camera. RESULTS: At 3 T, a significant RF-induced electric response could be demonstrated for the copper samples and more moderate for one of the commercial clips, dependent on the geometrical structure determining possible resonant RF coupling. Related RF effects could be distinguished from susceptibility artifacts: a signal enhancement at reduced transmitter voltages indicated locally amplified B1-field amplitudes. No significant heating effect could be measured by IR measurements. CONCLUSION: MR imaging was used to analyze possible RF-induced effects. At 3 T, resonant RF coupling even of small metallic implants has to be considered carefully. Despite a local enhancement of the RF amplitude, no significant RF-induced heating inside the surrounding fluid was found. A direct thermal endangering of patients seems to be unlikely, but extremely high B1-field amplitudes might occur adjacent to the metallic surface with potential nonthermal affection of tissue.  相似文献   

7.
The authors implemented bipolar velocity compensated pulse techniques for T2-weighted MR imaging of the brain. Signal-to-noise (S/N) and image quality was compared for pulse sequences with standard and optimized RF pulses, low and regular bandwidth versions and cardiac triggering. Images from bipolar velocity compensated sequences allowed better visualization of vessels and basilar cisterns and improved image quality relative to standard sequences without velocity compensation. The implementation of optimized RF pulses with bipolar sequences resulted in further improvement in image quality. Single echo sequences consistently had improved image quality and signal-to-noise relative to the second echo of a double echo sequence. Low bandwidth bipolar sequences with extended sampling period had 30% higher S/N, but at the cost of slight loss in edge definition. The highest image quality was obtained with the bipolar, optimized RF, single echo sequence. Using this technique contiguous high quality image slices could be obtained with velocity compensation. The addition of cardiac triggering to bipolar sequences resulted in slight improvement in image quality, but this difference was marginal and probably rarely necessary for MR imaging of the brain.  相似文献   

8.
A method to generate shaped radiofrequency pulses for uniform excitation of electron spins in time-domain radio frequency (RF) electron paramagnetic resonance (EPR) imaging is presented. A commercial waveform generator was integrated with the transmit arm of the existing time-domain RF-EPR spectrometer to generate tailored excitation pulses with sub-nano second resolution for excitation with a 90 degrees flip-angle. A truncated sinc [sin(x)/x] pulse, tailored to compensate for the Q-profile (RF frequency response) of the resonator, was shown to yield images from phantom objects as well as in vivo images, with minimal distortion. These studies point to the advantages in using shaped sinc pulses to achieve improved uniform excitation over a relatively wide bandwidth region in time-domain RF-EPR imaging (RF-FT-EPRI).  相似文献   

9.
This paper describes a new magnetic resonance spectroscopic imaging (MRSI) technique based upon the discrete wavelet transform to reduce acquisition time and cross voxel contamination. Prototype functions called wavelets are used in wavelet encoding to localize defined regions in localized space by dilations and translations. Wavelet encoding in MRSI is achieved by matching the slice selective RF pulse profiles to a set of dilated and translated wavelets. Single and dual band slice selective excitation and refocusing pulses, with profiles resembling Haar wavelets, are used in a spin-echo sequence to acquire 2D-MRSI wavelet encoding data. The 2D space region is spanned up to the desired resolution by a proportional number of dilations (increases in the localization gradients) and translations (frequency shift) of the Haar wavelets (RF pulses). Acquisition time is reduced by acquiring successive MR signals from regions of space with variable size and different locations with no requirement for a TR waiting time between acquisitions. An inverse wavelet transform is performed on the data to produce the correct spatial MR signal distribution.  相似文献   

10.
In NMR imaging and in vivo spectroscopy, slice selection is usually achieved by applying a frequency-selective RF pulse in the presence of a magnetic field gradient. A serious limitation of this method of slice selection is that, in a system with many different chemical shifts, the selected slice is offset in space for each chemically shifted resonance. In the present study, a composite RF pulse that is insensitive to chemical-shift differences has been developed. The pulse involves applying a RF pulse of desired shape in the presence of an alternating magnetic field gradient, together with hard 180° pulses at each gradient transition. Calculations are presented to show that excitation with the proposed pulse averages the chemical-shift term to zero. An exact calculation for a rectangular RF excitation shape verifies this. Experiments based on observing the RF excitation profiles have been performed to demonstrate the validity of the proposed pulse.  相似文献   

11.
近年来,为提高磁共振成像(MRI)信号信噪比(SNR)、缩短成像时间,同时多层成像技术受到了极大的关注.为了实现同时多层的选择性激发,现有的多层成像序列大多使用组合射频(RF)脉冲,该脉冲可包含多个独立的幅值相同相位不同的简单脉冲,由于其采用简单的线性叠加方法,该类脉冲射频功率随脉冲数量呈现平方增长,因而应用受限.针对这一问题,基于自旋动力学和优化控制原理,本文提出了一种针对同时多层MRI的选择性射频脉冲的数值优化方法,该方法充分运用射频脉冲的调控机制,获得优化脉冲,并配合层选梯度,可实现任意层厚、层间距、层数的同时高效选择性激发.最后,通过数字模体的同时多层模拟成像实验验证了优化脉冲的有效性.  相似文献   

12.
Calculated T1 images of the head and abdomen have been obtained using an alternating partial saturation-inversion recovery pulse sequence. Timing parameters were adjusted to yield optimum T1 contrast-to-noise ratio for this sequence for the range of T1 studied. Adiabatic fast passage (AFP) was implemented for the nonselective inverting pulse, to reduce the sensitivity of the measurement to RF and static field inhomogeneity. A nonlinear frequency sweep was used to improve the efficiency of the AFP pulse. The effect on the T1 calculation of slice selection during the pi/2 pulses was also determined and corrected for in the image reconstruction algorithm. The T1's determined by this method show a standard deviation of less than 10%, and good agreement with the literature.  相似文献   

13.
Hyperpolarized 13C offers high signal-to-noise ratios for imaging metabolic activity in vivo, but care must be taken when designing pulse sequences because the magnetization cannot be recovered once it has decayed. It has a short lifetime, on the order of minutes, and gets used up by each RF excitation. In this paper, we present a new dynamic chemical-shift imaging method that uses specialized RF pulses designed to maintain most of the hyperpolarized substrate while providing adequate SNR for the metabolic products. These are multiband, variable flip angle, spectral-spatial RF pulses that use spectral selectivity to minimally excite the injected prepolarized 13C-pyruvate substrate. The metabolic products of lactate and alanine are excited with a larger flip angle to increase SNR. This excitation was followed by an RF amplitude insensitive double spin-echo and an echo-planar flyback spectral-spatial readout gradient. In vivo results in rats and mice are presented showing improvements over constant flip angle RF pulses. The metabolic products are observable for a longer window because the low pyruvate flip angle preserves magnetization, allowing for improved observation of spatially varying metabolic reactions.  相似文献   

14.
PurposeTo investigate velocity encoded and velocity compensated variants of multi-spoke RF pulses that can be used for flip-angle homogenization at ultra-high fields (UHF). Attention is paid to the velocity encoding for each individual spoke pulse and to displacement artifacts that arise in Fourier transform imaging in the presence of flow.Theory and methodsA gradient waveform design for multi-spoke excitation providing an algorithm for minimal TE was proposed that allows two different encodings. Such schemes were compared to an encoding approach that applies an established scheme to multi-spoke excitations. The impact on image quality and quantitative velocity maps was evaluated in phantoms using single- and two-spoke excitations. Additional validation measurements were obtained in-vivo at 7 T.ResultsPhantom experiments showed that keeping the first gradient moment constant for all k-space lines eliminates any displacements in phase-encoding and slice-selection direction for all spoke pulses but leads to artifacts for non-zero velocity components along readout direction. Introducing variable but well-defined first gradient moments in the phase-encoding direction creates displacements along the velocity vector and thus minimizes velocity-induced geometrical distortions. Phase-resolved mean volume flow in the ascending and descending aorta obtained from two-spoke excitation showed excellent agreement with single-spoke excitation over the cardiac cycle (mean difference 0.8 ± 16.2 ml/s).ConclusionsThe use of single- and multi-spoke RF pulses for flow quantification at 7 T with controlled displacement artifacts has been successfully demonstrated. The presented techniques form the basis for correct velocity quantification and compensation not only for conventional but also for multi-spoke RF pulses allowing in-plane B1+ homogenization using parallel transmission at UHF.  相似文献   

15.
At high magnetic field, B(1)(+) non-uniformity causes undesired inhomogeneity in SNR and image contrast. Parallel RF transmission using tailored 3D k-space trajectory design has been shown to correct for this problem and produce highly uniform in-plane magnetization with good slice selection profile within a relatively short excitation duration. However, at large flip angles the excitation k-space based design method fails. Consequently, several large-flip-angle parallel transmission designs have recently been suggested. In this work, we propose and demonstrate a large-flip-angle parallel excitation design for 90 degrees and 180 degrees spin-echo slice-selective excitations that mitigate severe B(1)(+) inhomogeneity. The method was validated on an 8-channel transmit array at 7T using a water phantom with B(1)(+) inhomogeneity similar to that seen in human brain in vivo. Slice-selective excitations with parallel RF systems offer means to implement conventional high-flip excitation sequences without a severe pulse-duration penalty, even at very high B(0) field strengths where large B(1)(+) inhomogeneity is present.  相似文献   

16.
Spectral editing using gradient selected double-quantum (DQ) coherence transfer is often used for the selective observation of metabolites in vivo. In attempting to optimize the detection sensitivity of a conventional DQ spectral editing sequence, the effects of using radiofrequency (RF) pulses that are not at the resonance frequency of the observed peaks were investigated both theoretically and experimentally. The results show that spectral editing using pulses at the frequency of the observed resonance does not necessarily give the optimal detection sensitivity. At 7 T, the detection sensitivity of lactate observed using a DQ editing method can be increased by up to 30% by setting the RF pulses off resonance at the proper frequency. The results also suggest that slice selective RF pulses used in DQ spectral editing combined with PRESS localization may have slice profiles different from those when the same pulses are used for standard PRESS spatial localization.  相似文献   

17.
Sodium magnetic resonance (MR) imaging is a promising technique for detecting changes of proteoglycan (PG) content in cartilage associated with knee osteoarthritis. Despite its potential clinical benefit, sodium MR imaging in vivo is challenging because of intrinsically low sodium concentration and low MR signal sensitivity. Some of the challenges in sodium MR imaging may be eliminated by the use of a high-sensitivity radiofrequency (RF) coil, specifically, a dual-tuned (DT) proton/sodium RF coil which facilitates the co-registration of sodium and proton MR images and the evaluation of both physiochemical and structural properties of knee cartilage. Nevertheless, implementation of a DT proton/sodium RF coil is technically difficult because of the coupling effect between the coil elements (particularly at high field) and the required compact design with improved coil sensitivity. In this study, we applied a multitransceiver RF coil design to develop a DT proton/sodium coil for knee cartilage imaging at 3 T. With the new design, the size of the coil was minimized, and a high signal-to-noise ratio (SNR) was achieved. DT coil exhibited high levels of reflection S11 (~-21 dB) and transmission coefficient S12 (~-19 dB) for both the proton and sodium coils. High SNR (range 27-38) and contrast-to-noise ratio (CNR) (range 15-21) were achieved in sodium MR imaging of knee cartilage in vivo at 3-mm(3) isotropic resolution. This DT coil performance was comparable to that measured using a sodium-only birdcage coil (SNR of 28 and CNR of 20). Clinical evaluation of the DT coil on four normal subjects demonstrated a consistent acquisition of high-resolution proton images and measurement of relative sodium concentrations of knee cartilages without repositioning of the subjects during the same MR scanning session.  相似文献   

18.
Ultra-high-field 7 T magnetic resonance (MR) scanners offer the potential for greatly improved MR spectroscopic imaging due to increased sensitivity and spectral resolution. Prior 7 T human single-voxel MR Spectroscopy (MRS) studies have shown significant increases in signal-to-noise ratio (SNR) and spectral resolution as compared to lower magnetic fields but have not demonstrated the increase in spatial resolution and multivoxel coverage possible with 7 T MR spectroscopic imaging. The goal of this study was to develop specialized radiofrequency (RF) pulses and sequences for three-dimensional (3D) MR spectroscopic imaging (MRSI) at 7 T to address the challenges of increased chemical shift misregistration, B1 power limitations, and increased spectral bandwidth. The new 7 T MRSI sequence was tested in volunteer studies and demonstrated the feasibility of obtaining high-SNR phased-array 3D MRSI from the human brain.  相似文献   

19.
In this study 2H T2rho DQF NMR spectra of water in MCM-41 were measured. The T2rho double-quantum filtered (DQF) NMR signal is generated by applying a radio frequency (RF) field for various durations and then observed after a monitor RF pulse. It was found that the transfer between different quantum coherences by the couplings during long-duration RF fields (i.e., soft pulses) and that residual quadrupolar interaction dominates the signal decay. Knowledge of coherence transfer during long-RF pulses has special significance for the development of sophisticated multi-quantum NMR experiments especially multi-quantum MRI applications.  相似文献   

20.
PurposeThis study aimed at introducing short-T1/T2 compartment to MR fingerprinting (MRF) at 3 T. Water that is bound to myelin macromolecules have significantly shorter T1 and T2 than free water and can be distinguished from free water by multi-compartment analysis.MethodsWe developed a new multi-inversion-recovery (mIR) water mapping-MRF based on an unbalanced steady-state coherent sequence (FISP). mIR pulses with an interval of 400 or 500 repetition times (TRs) were inserted into the conventional FISP MRF sequence. Data from our proposed mIR MRF was used to quantify different compartments, including myelin water, gray matter free water, and white matter free water, of brain water by virtue of the iterative non-negative least square (NNLS) with reweighting. Three healthy volunteers were scanned with mIR MRF on a clinical 3 T MRI.ResultsUsing an extended phase graph simulation, we found that our proposed mIR scheme with four IR pulses allowed differentiation between short and long T1/T2 components. For in vivo experiments, we achieved the quantification of myelin water, gray matter water, and white matter water at an image resolution of 1.17 × 1.17 × 5 mm3/pixel. As compared to the conventional MRF technique with single IR, our proposed mIR improved the detection of myelin water content. In addition, mIR MRF using spiral-in/out trajectory provided a higher signal level compared with that with spiral-out trajectory. Myelin water quantification using mIR MRF with 4 IR and 5 IR pulses were qualitatively similar. Meanwhile, 5 IR MRF showed fewer artifacts in myelin water detection.ConclusionWe developed a new mIR MRF sequence for the rapid quantification of brain water compartments.  相似文献   